Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | Admitted-Finance |
Tender Value
₹20.0 L
EMD Value
₹39,960
Closing Date
9 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BIDAR
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
MAINTENANCE AND REPAIRS TO LIGHT FITTING INSIDE THE HANGARS / SUNSHELTERS IN TECHNICAL AREA AT AFS BIDAR
2021_MES_481407_1
8116/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF BIDAR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF BIDAR
₹39,960
Yes
30 Nov 2021
12 Oct 2021
10 Nov 2021
12 Oct 2021
9 Nov 2021
26 Oct 2021
60 days
Amount
Disconnection and removing the unserviceable high/Med/ Low bay /security light fitting/Integral CFL light Fittings/Infra red light fittings from any height of the Hangers/ Sunshelters of capacities 70W/85 W/ 100W/125W/150W /250W/400 W along with its connecting iron brackets complete for repairs for finding out faults and to replace the defective parts like ballast, lamp, ignitor, condenser, Reflector, Refractor, housing and control gear case etc as mentioned here-in after, and refix the same in its original position with clamps, nuts & bolts complete all as specified and as directed.
Supply only capacitor 10 MFD AC 250 volts complete all as specified and as directed.
Supply only capacitor 15 MFD AC 250 volts complete all as specified and as directed.
Supply only capacitor 20 MFD AC 250 volts complete all as specified and as directed.
Supply only 400 Watt, 230 volts metal halide lamp complete all as specified and as directed.
Supply only Copper Ballast for High Bay light fitting 400 watt MH enclosed type complete all as specified and as directed.
Supply only Neck Reflector made of die cast Aluminium open type suitable for High Bay light fitting 400 watt MH complete all as specified and as directed.
Supply only Glass including Gasket and toggles suitable for 400 watt MH enclosed type complete all as specified and as directed.
Supply only 250 Watt, 230 volts metal halide lamp complete all as specified and as directed.
Supply only Copper Ballast for High Bay light fitting 250 Watt MH , 250 volts suitable for Integral type complete all as specified and as directed.
Supply only Neck Reflector with made of die cast Aluminium open type suitable for High Bay light fitting 250 watt MH suitable for Integral type complete all as specified and as directed.
Supply only Glass including Gasket and toggles suitable for 250 watt MH enclosed type complete all as specified and as directed.
Supply only CFL lamp 85W DF 4U 6500K (B22 / E 27) direct fit ( high wattage) complete all as specified and as directed.
Supply only housing for Low Bay light fitting CFL 85 Watt enclosed type complete all as specified and as directed.
Supply only porcelain lamp holder screw type suitable for 70 Watt to 150 Watt 230 volts lamp fittings complete all as specified and as directed.
Supply only porcelain lamp holder screw type suitable for 250 to 400 watt 230 volts lamp fittings complete all as specified and as directed.
Supply only ignitor suitable for HPSV/HPMV/MH fitting for 70 W to150 W, 230 volts complete all as specified and as directed.
Supply only ignitor suitable for HPSV/HPMV/MH fitting for 250 W to 400 W, 230 volts complete all as specified and as directed.
Supply only Copper Ballast for HPMV Fitting 125 watt, 230 volts complete all as specified and as directed.
Supply only Copper Ballast for HPMV Fitting 250 watt, 230 volts complete all as specified and as directed.
Supply only open construction heavy duty copper ballast 250 watts, 230 V single phase suitable for SV fittings street lights/flood light fittings complete all as specified and as directed.
Supply only open construction heavy duty copper ballast 150 watts 230 V single phase suitable for SV fittings street lights/flood light fittings complete all as specified and as directed.
Supply only open construction heavy duty copper ballast 70 watts, 230 V single phase, suitable for SV fittings street lights/flood light fittings complete all as specified and as directed.
Supply only 150 Watt, 230 volts metal halide lamp type DE complete all as specified and as directed.
Supply only 150 Watt, 230 volts infra red lamp complete all as specified and as directed. Note for item No. 2 to 24 : - Labour element involved is deemed to be included in unit rate quoted for Item No. 1 above.
Disconnection and taking down the unserviceable High Bay light fitting 400 watt MH S&F for New High Bay light fitting 400 watt MH Integral type comprising of aluminium anodized reflector, copper ballast, glass with gasket and goggles and including MH lamp 400 W complete all as specified and as directed.
Disconnection and taking down the unserviceable 250W High Bay light fitting and S&F High Bay light fitting 250 Watt MH Integral type complete with aluminium reflector, copper ballast with housing, glass with gasket and goggles and incluing MH 250 W lamp complete all as specified and as directed.
Disconnection and taking down the unserviceable 150W light fitting and S & F Pressure die-cast aluminium integral Flood light luminaire suitable for MH DE lamp fitting including 150 watt MH DE lamp complete all as specified and as directed.
Disconnection and taking down the unserviceable light fitting 125W and S & F vertical integral well glass light fitting 125 Watt MH type including 125W lamp complete all as specified and as directed.
Disconnection and taking down the unserviceable fitting and S&F aviation obstruction light fitting including two Nos of GLS 100 W bulbs complete all as specified and as directed.
Disconnection and taking down the CFL decortive fitting from the roof of the building and S&F suspended type decorative CFL LAMP fitting with polycarbonate refractor 19"with refractor bottom cover 19 "in and including one no CFL RF 85 W capacity with necessary hanging arrangements from roof / MS angles at hangers complete all as specified and as directed.
M&L for sub main wiring/power wiring with 2 runs of 1.5 sqmm PVC insulated multi stranded copper conductor FRLS 1100 V cable and one run of 1.5 sqmm copper FRLS 1100V cable as earth lead drawn in existing ERW steel conduit including taking down old unserviceable wiring complete all as specified and as directed. Note : Two runs of of 1.5 sqmm PVC insulated stranded copper conductor and one run of earth wire 1.5 sqmm shall be measured and paid as one unit.
M&L for sub main wiring/power wiring with 2 runs of 2.5 sqmm PVC insulated multi stranded copper conductor FRLS 1100 V cable and one run of 2.5 sqmm copper FRLS 1100V cable as earth lead drawn in existing ERW steel conduit including taking down old unserviceable wiring complete all as specified and as directed. Note : Two runs of 2.5 sqmm PVC insulated stranded copper conductor and one run of earth wire 2.5 sqmm shall be measured and paid as one unit.
M&L for sub main wiring/power wiring with 2 runs of 4.0 sqmm PVC insulated multi stranded copper conductor FRLS 1100 V cable and one run of 4.0 sqmm copper FRLS 1100V cable as earth lead drawn in existing ERW steel conduit including taking down old unserviceable wiring complete all as specified and as directed. Note : Two runs of of 4 .0 sqmm PVC insulated stranded copper conductor and one run of earth wire 4.0 sqmm shall be measured and paid as one unit.
M&L for sub main wiring/power wiring with 4 runs of 6.0 sqmm PVC insulated multi stranded copper conductor FRLS 1100 V cable and two run of 6 sqmm copper FRLS 1100V cable as earth lead drawn in existing ERW steel conduit including taking down old unserviceable wiring complete all as specified. Note : Four runs of 6.0 sqmm PVC insulated stranded copper conductor and two runs of earth wire 6.0 sqmm shall be measured and paid as one unit.
Disconnection and taking down the unserviceable interior unit of change over switch along with cable connections and S&F new interior unit of on load change over switch four pole 415 volts 125 Amps in the existing enclosure unit and connectiong up of all the cable connections complete all as specified and as directed.
Disconnection and taking down the unserviceable MCB DB TPN 4 way with one MCCB and S&F MCB DB TPN IP 54, 4 way including one MCCB 125A 4 pole, 25 KA as incoming complete in sheet metal enclosures vertical type double door complete all as specified and as directed.
Disconnection and taking down the unserviceable MCCB 4 pole 25 KA 63 Amps and S&F MCCB 4 pole 25 KA of capacity 63Amps complete all as specified and as directed.
Disconnection and taking down the unserviceable MCCB 4 pole 25 KA 100 Amps and S&F MCCB 4 pole 25 KA of capacity 100 Amps complete all as specified and as directed.
Disconnection and taking down the unserviceable MCCB 4 pole 25 KA 160 Amps and S&F MCCB 4 pole 25 KA of capacity 160 Amps complete all as specified and as directed.
Disconnection and taking down the unserviceable MCCB 4 pole 35 KA 250 Amps and S&F MCCB 4 pole 36 KA of capacity 250Amps complete all as specified and as directed.
Disconnection and taking down the unserviceable metal plug and socket and S&F Metal plug and socket with MCB SP 3 Pin 32 Amps complete all as specified and as directed.
Disconnection and taking down the unserviceable metal plug and socket and S&F Metal plug and socket with MCB three Phase 5 Pin 63 Amps complete all as specified and as directed.
Supply only 250 Watt, 230 Volts HPSV lamp complete all as specified and as directed.
Supply only 150 Watt, 230 Volts HPSV lamp complete all as specified and as directed.
Supply only 70 Watt, 230 Volts HPSV lamp complete all as specified and as directed.
Disconnection and taking down the unserviceable High Bay light fitting 250 watt MH and S&F for Flame proof - WP flood light fitting 250 watt MH in LM6 construction integral type including 100 W LED lamp with inbuilt control gear box, driver and connecting wires etc complete all as specified and as directed.
Disconnection and taking down the unserviceable low integral well glass luminarie 125 W and S&F for New industrial low bay light fitting 80 watt LED energy saving environment friendly and robust IP-65 with high efficacy complete all as specified and as directed
Supply only 125 Watt, 230 Volts HPMV lamp complete all as specified and as directed.
Supply only 250 Watt, 230 Volts HPMV lamp complete all as specified and as directed.
Disconnection and taking down the unserviceable light fittings and S&F Sonara Bollard decorative Luminaire with 18 Watt CFL lamp complete all as specified and as directed
S&F LED highbay light fitting 120 Watts with housing IP -65 and IK 07, circular high pressure die cast aluminium housing and manufacture logo embossed on the housing and high transmittance tempered glass cover, optics lens with lens plate having NB and WB optics, system efficacy>120 lumens/watt, xitanium driver- IP 66 complying to IEC61347-2-13 certification like CE ENEC, ROHS, with rated life of 50000 hrs for driver at TC-80 degree celcius along with all safety features, thermal protections, protection against input over voltage<320 volt AC for 48 hrs, driver failure rate,0.2% per 1KHr @ TC 70-80 Degree Celcius, wattage 120 Watt, internal wiring teflon SDCM<5, CCT-5700, CRI>80, THD<20 at max load, third harmonics<20%, PF>0.95 colour temperature 6500k including taking down old unserviceable light fitting complete all as specified and as directed.
Flame proof - WP Fluorescent fixture for power saving lamps with wire guard flame proof integral well glass luminaire with HID lamp 125W HPMV including taking down existing fittings complete all as specified and as directed.
Flame proof - WP Fluorescent fixture for power saving lamps with wire guard flame proof integral well glass luminaire with HID lamp 250W HPMV including taking down existing fittings complete all as specified and as directed.
Flame proof - WP switch 16 Amps Double pole ON/Off including taking down existing all as directed.
Flame proof -WP rotary switch socket combination in LM6, 10 Amps complete including taking down existing complete all as specified and as directed.
Mr Madhusudhan Kotarki
om sai enterprises
ASHWAMEDH ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .