Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance G 102 PLOT NO 123 SECTOR 06 VAISHALI GHAZIABAD U P 2010 | 2010 | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹4.5 L (2.77%)Admitted-Finance REVENUE WARD 8 8 2 220 GANDLA STREET SULLURU SULLURPET NELLORE ANDHRA PRADESH 524121 | SPSR NELLORE | ANDHRA PRADESH | 524121 | ₹1.7 Cr+₹4.5 L (2.77%) | L2 | Admitted-Finance |
| 3 | L3₹2.1 Cr+₹44.8 L (27.3%)Admitted-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹2.1 Cr+₹44.8 L (27.3%) | L3 | Admitted-Finance |
| 4 | L4₹2.1 Cr+₹44.9 L (27.4%)Admitted-Finance 2 NEW ROAD RATLAM RATLAM MADHYA PRADESH 457001 | RATLAM | MADHYA PRADESH | 457001 | ₹2.1 Cr+₹44.9 L (27.4%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not meeting NIT criterion |
| Sl No | Description | Qty | Unit | Aditya Techno Products Private Limited L1 | CHANDRA REDDY ELECTRICALS L2 | G. D. Anklesaria & Co. L4 | Mona Generator Services Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Design, manufacturing, supply, installation, testing and commissioning of 250 kVA, 3 phase, 4wire, 415 V, 50 Hz DG set in acoustic enclosure with Auto ON/OFF provision during power failure along with control wiring and all accessories as per attached tech. specification Doc No. TS-1 | 1 | SET | 25,25,555.5 ₹25,25,555.5 Lowest | 26,71,650 ₹26,71,650 | 32,28,000 ₹32,28,000 | 27,49,011 ₹27,49,011 |
| 2.00 | Design, manufacturing, supply, installation, testing and commissioning of 125 kVA, 3 phase, 4 wire, 415 V, 50 Hz DG set in acoustic enclosure with Auto ON/OFF provision during power failure along with control wiring and all accessories as per aattached tech. specification DocNo. TS-2 | 2 | SET | 14,34,533.3 ₹28,69,066.6 | 13,98,000 ₹27,96,000 Lowest | 19,45,800 ₹38,91,600 | 16,47,931 ₹32,95,862 |
| 3.00 | Supply, Installation, Testing and Commissioning of LT AMF panel for Auto/Mains failure function for 250 kVA DG set, including Control wiring and all accessories as per attached specification TS Doc. No. TS-3 | 1 | Nos | 8,39,839.98 ₹8,39,839.98 | 8,17,266 ₹8,17,266 Lowest | 9,92,000 ₹9,92,000 | 13,09,670 ₹13,09,670 |
| 4.00 | Supply, Installation, Testing and Commissioning of AMF panel for Auto/Mains failure function for 125 KVA DG Set including Control wiring and all accessories at Anuvihar and CGH as per attached tech. specification Doc. No. TS -4 | 2 | Nos | 8,39,839.98 ₹16,79,679.96 | 8,17,266 ₹16,34,532 Lowest | 9,92,000 ₹19,84,000 | 13,09,670 ₹26,19,340 |
| 5.00 | Supply, Installation, Testing and Commissioning of New LT Panel with 2 incomers and 1 Bus Coupler as per attached tech. specification Doc. No. TS-5 | 1 | Nos | 32,41,749.88 ₹32,41,749.88 Lowest | 38,60,553 ₹38,60,553 | 42,31,520 ₹42,31,520 | 46,96,574 ₹46,96,574 |
| 6.00 | Adopter box (enclosure) for outdoor installation IP-65 with 250A, 4P, 50 KA (MCCB), with copper bus bar. The required setup is an MCCB Enclosure designed for termination of 3.5C X 400 Sqmm Al condcutor, LT Cable as per attached tech. specification Doc. No. TS-6 | 3 | Nos | 1,08,560 ₹3,25,680 | 78,632 ₹2,35,896 Lowest | 2,52,000 ₹7,56,000 | 2,55,811 ₹7,67,433 |
| 7.00 | SITC of 990 litres M.S. fuel day tank with necessary fittings like explosion proof level indicator for local as well remote monitoring with GCU communication protocol along with Fuel Piping connection from day tank to Generator tank for 250kVA DG Set as per attached tech. specification Doc. No. TS-7 | 1 | Nos | 75,152.08 ₹75,152.08 | 75,000 ₹75,000 | 78,000 ₹78,000 | 68,139 ₹68,139 Lowest |
| 8.00 | SITC of 3.5 C X 185 sq.mm armoured, XLPE, 1100V, Aluminium conductor cable as per attached tech. specification Doc. No. TS-8 | 500 | M | 1,471.74 ₹7,35,870 | 1,366 ₹6,83,000 Lowest | 2,065.61 ₹10,32,805 | 1,695 ₹8,47,500 |
| 9.00 | SITC of 10C X 2.5 sq.mm, armoured XLPE, CU conductor cable for control wiring as per attached tech. specification Doc. No.-9 | 100 | M | 586.84 ₹58,684 Lowest | 664 ₹66,400 | 933.12 ₹93,312 | 839 ₹83,900 |
| 10.00 | SITC of 4C X 2.5 sq.mm armoured XLPE LT CU conductor cable for controll wiring as per attached tech. specification Doc. No. TS--10 | 100 | M | 271.2 ₹27,120 Lowest | 327 ₹32,700 | 405.36 ₹40,536 | 373 ₹37,300 |
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
27 May 2026, 6:00 pmClosed
Chief Engineer, ESS(V), BARC(V)
Administrative Building, BARC Main Site, Yellamanchilli Highway, Near Nagavaram Junction, Maduturu (Sub-P.O.) Visakhapatnam - 531011
Supply, installation, testing and commissioning of DG sets, LT panels and associated power cabling works at Simhadri Bhavan, Anu Vihar Colony near Atchutapuram and Visakha Sadan Guest House at Akkayyapalem, Visakhapatnam, Andhra Pradesh.
2026_BARC_906870_1
BARC-V/ESS-V/2026/06
Open Tender
Electrical Works
Item Rate
180 days
Simhadri Bhavan, Anu Vihar Colony near Atchutapura
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹3.6 L
9 Jul 2026
29 Apr 2026
5 Jun 2026
29 Apr 2026
27 May 2026
15 May 2026
29 Apr 2026 - 13 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, manufacturing, supply, installation, testing and commissioning of 250 kVA, 3 phase, 4wire, 415 V, 50 Hz DG set in acoustic enclosure with Auto ON/OFF provision during power failure along with control wiring and all accessories as per attached tech. specification Doc No. TS-1 | 1 | SET | 100 | ₹100 |
| 2 | Design, manufacturing, supply, installation, testing and commissioning of 125 kVA, 3 phase, 4 wire, 415 V, 50 Hz DG set in acoustic enclosure with Auto ON/OFF provision during power failure along with control wiring and all accessories as per aattached tech. specification DocNo. TS-2 | 2 | SET | 10 | ₹20 |
| 3 | Supply, Installation, Testing and Commissioning of LT AMF panel for Auto/Mains failure function for 250 kVA DG set, including Control wiring and all accessories as per attached specification TS Doc. No. TS-3 | 1 | Nos | 10 | ₹10 |
| 4 | Supply, Installation, Testing and Commissioning of AMF panel for Auto/Mains failure function for 125 KVA DG Set including Control wiring and all accessories at Anuvihar and CGH as per attached tech. specification Doc. No. TS -4 | 2 | Nos | 10 | ₹20 |
| 5 | Supply, Installation, Testing and Commissioning of New LT Panel with 2 incomers and 1 Bus Coupler as per attached tech. specification Doc. No. TS-5 | 1 | Nos | 10 | ₹10 |
| 6 | Adopter box (enclosure) for outdoor installation IP-65 with 250A, 4P, 50 KA (MCCB), with copper bus bar. The required setup is an MCCB Enclosure designed for termination of 3.5C X 400 Sqmm Al condcutor, LT Cable as per attached tech. specification Doc. No. TS-6 | 3 | Nos | 10 | ₹30 |
| 7 | SITC of 990 litres M.S. fuel day tank with necessary fittings like explosion proof level indicator for local as well remote monitoring with GCU communication protocol along with Fuel Piping connection from day tank to Generator tank for 250kVA DG Set as per attached tech. specification Doc. No. TS-7 | 1 | Nos | 100 | ₹100 |
| 8 | SITC of 3.5 C X 185 sq.mm armoured, XLPE, 1100V, Aluminium conductor cable as per attached tech. specification Doc. No. TS-8 | 500 | M | 100 | ₹50,000 |
| 9 | SITC of 10C X 2.5 sq.mm, armoured XLPE, CU conductor cable for control wiring as per attached tech. specification Doc. No.-9 | 100 | M | 100 | ₹10,000 |
| 10 | SITC of 4C X 2.5 sq.mm armoured XLPE LT CU conductor cable for controll wiring as per attached tech. specification Doc. No. TS--10 | 100 | M | 100 | ₹10,000 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 14.74 MB
FORMSATOH062026.xls
Tender Documents • 0.06 MB
LETTERTRANSMITTAL062026.pdf
Tender Documents • 0.24 MB
TechSpec062026.pdf
Tender Documents • 1.05 MB
FORMOFAGREEMENT062026.pdf
Tender Documents • 0.41 MB
TenderVolume1062026.pdf
Tender Documents • 2.01 MB
BOQ_953199.xls
BOQ • 0.33 MB
ResponseToPrebidQueries.pdf
PDF • 4.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .