Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | Admitted-Finance |
| 2 | Admitted-Finance JOY VILA MRA 230 MOOLAVILKOM JUNCTION VANCHIYOOR TRIVANDRUM 695 035 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695035 | Admitted-Finance |
Tender Value
₹13.7 L
EMD Value
₹27,400
Closing Date
18 Aug 2022, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIC SUPPLY INCLUDING PANEL BOARD STRUCTURES AT CERTAIN UNITS AT SHANKHUMUKHAM, MUKKUNNIMALA AND MUTTATHARA UNDER GE AF TRIVANDRUM
2022_MES_539528_1
8375
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Trivandrum
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹27,400
Yes
26 Aug 2022
20 Jul 2022
20 Aug 2022
20 Jul 2022
18 Aug 2022
4 Aug 2022
Amount
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and getting out complete all as specified.
Returning and filling of excavated soil up to a depth of 30 cm after riddling the excavated soil for Cushioning of cable and refilling of trench with normal excavated soil all as specified and directed.
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Supply and filling in repairs Transformer oil of dielectric strength not less than 40 KV, conforming to IS-335 in Servo voltage stabilizer/Transformer all as directed.
Supply & filling in repairs silica gel inside breather assembly of trasformer all as directed.
Supply and fix in repairs cable jointing kit for 11 KV grade cable for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured, Al conductor cables, earthed system of size 120 Sqmm all as specified and as directed
Dehydration/Filtration of Transformer oils of Transformer/Switch gears/ Servo voltage stabilizer using oil filtration plant for removing the moisture contents and carbon deposits from the oil and bringing it to the dielectric strength not less than 40 KV.
Supply & fixing breather assembly suitable for outdoor type trasformer with silica gel including taking down u/s from the transformer all as directed.
Taking down old steel/ PCC pole and Supply and errect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws, as specified type 410 SP-31 (9.0 metres long) all as specified and as directed.
M&L for painting on steel tubular poles of height 7.5 Mtr above gound level by applying two coats of Aluminium paint over one coat of red oxide primer on street light pole bracket /clamps terminal box etc including applying two coats of cement based paint over one coat of suitable primer for coping and writing pole number in black and white Paint complete all as specified and directed.
M&L for painting on PCC poles of height 7.5 Mtr above gound level by applying two coats of exterior weather coat paint over one coat of suiable primer on existing poles including copping and writing pole number in black and white Paint complete all as specified and directed.
Taking down old rusted monkey cage on street light pole made out of wire mesh and welding and strengthening with additional length of angle iron of suitablle size and wire mesh as required and rifixing in position after painting with one coat of aluminium paint over one coat of suitable primer complete all as specified and directed by engr-in- charge
M&L for painting of monkey cage on steel pole with two coats of synthetic enamel paint of approved shade over one coat of zinc chrome primer including removing of rust/foreign materials from surface of monkey cage with wire brush complete all as specified directed.
Comprehensive maintenance of Reciprocating type High Pressure Air compressor capacity 7.5 HP. Make: ELGI including replacement of filter elements and complete servicing of lubricating oil strainer, suction filter and minor components, inter cooling and after cooling system for functional checking all as specified and directed.
Repair & Servicing of Oil filled Servo voltage stabilizer 150 KVA Make : Micron including necessary welding of body with additional sheets required for arresting the oil leak including topping up / filtration of oil complete all as specified and directed. Note: Topping up/ Filtration of oil will be measured and paid seperately
Supply, install, test and commissioning in repairsoutdoor type LT feeder pillar box KIOSK type, platform mounted, factroy made, totally enclosed, dust and vermin proof IP55 made of 3.15 mm CRCA sheet MS flat and angle support/frames, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and confirming to IS 5039 /IS 8623 and other relevent IS /IEC codes and CPRI type tested, duly powder coated both internally and externally suitable for 415 Volts 50 HZ 3 phase 4 wire system and comprising of the following features and accessories /components installed on existing PCC platform with nut bolts all as specified and as directed:-
OUTGOING:- i) MCCB 3 pole 100 Amps capacity 25 A braking capacity, 415 volts, 50 Hz, fixed thermal magnetic type -03 Nos ii) MCCB 3 pole 63 Amps capacity, 16KA braking capacity,415 volts, 50 Hz fixed thermal magnetic type -03 Nos
Servicing/ maintenance of UPS capacity 30 KVA and replacement of following parts including testing after completion of work all as specified and directed. (i) Inverter card M080 - 01 No (ii) DC-DC Card M10D - 01 No (iii) IGBT Driver card M 27D - 01 No (iv) IGBT 100A - 02 Nos (v) AC Capacitor 100Mfd,440V - 01 No
M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation of poles including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete all as specified.
M&L for Plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in coping including finishing to exposed concrete surfaces even and fair and provision of necessary form work for rough finished surfaces complete including demolition of old damaged pole copings all as specified and directed.
Taking out damaged butt hinges and locking arrangement from out door type LT Panel door and M&L for welding new hinges and locking arrnagement on the panel door including denting/adjusting the door for proper closing and Preparing old painted outer exposed surfaces of LT Panel Board of area not less than 5 Sqm, all exposed surfaces of steel items fixed with the Panel, without dismantling and painting with two coats of synthetic enamel paint of approved shade all as specified and directed.
Supply and lay in trenches/under roads/crossings or fixed to wall/pole, GI tubing light grade of following sizes for protection of UG cables including taking out old unserviceable pipes and remove from site. Note : Excavation and earth work shall be measured and paid separately under relevant items of this schedule.
80 mm dia
50 mm dia
Supply and laying in trenches/through pipes or bore in road crossings/ paths/ drains/ ducts/ floors/ along poles/ walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 11000 Volts grade of cross sectional area 120 Sqmm, 3 core including removing of old U/S cable all as specified and directed by the Engr-in-Charge.
Supply and laying in trenches/through pipes or bore in road crossings/ paths/ drains/ ducts/ floors/ along poles/ walls/ ceilings/ equipments etc. Cable Under ground, Heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of following cross sectional area including removing of old U/S cable all as specified and directed by the Engr-in-Charge :-
120 Sqmm 3.5 core
95 Sqmm 3.5 core
50 Sqmm 3.5 core
25 Sqmm 3.5 core
10 Sqmm 4 core
10 Sqmm 2 core
Earthing complete with Copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting copper strip of size 20mm x 3mm from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Earthing complete with Galvanised iron earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI strip of size 32mm x 6mm from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
Earthing complete with Galvanised iron earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below ground level, connecting GI earth lead wire 4mm dia from earth plate to body of the equipment/LT Panel by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 20 mm bore GI light grade pipe for protection of earth lead from earth plate(6 mtrs long), 20 mm GI light grade watering pipe, PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in earhing pit, PCC cover, charcoal or coke & salt filling and necessary excavation and earth work and all other relevant works including testing all as specified and shown in electrical plate No.3 of MES Schedule part-I.
M&L for of replacement of 11KV, 630A, 25KA Airbreak Load Break Switch complete with fuse trip and shunt trip including taking out old unserviceable item and supply and fixing of following items including testing on completion all as specified and directed. (i) Bus support insulator - 06 Nos, (ii) Wall through bushings - 06 Nos, (iii) Hardware,busbar sleeves, FRP sheet, round and flat beadings and miscellaneous items including heater with thermostat. (iv) Retrofitting charges of load break switch and control wiring- 01 Job
Attending, Repairing/restoring of electric power supply in the AF Stn 17 FBSU and its lodger Unit area, after identifying fault in HT 11 KV or LT 1100 volt system, RMU, VCB, LT Panels, two/ four pole structure, transformers, Over head lines in any section or circuit, including checking of insulators, lightning arresters, GODs, LT Panel Boards and all electrical accessories and making it serviceable in all respect including replacement of nut, bolt, washers and minor parts/spares, insulation tapes and cable sockets of any size. The work also include checking, identifying and rectifcation of LT/HT UG Cable faults at AF Area as and when directed.
Notes : (i) Major items required to be replaced/repaired will be measured and paid seperately under relevant items of this schedule (ii) Excavation and earth work if required will be measured and paid seperately under relevant items of this schedule (iii) Complaints will be given in person or through telephone by AGE/JE E/M. The contractor shall attend the complaint immediately and shall report the Engr-in-Charge/JE E/M after completion with in 6 hrs (iv) Penalty of Rs 1000.00 per Job shall be applicable to the contractor if the complaint is not attended within 6 hrs. Note that this penalty is exclusively other than the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer in this regards shall be final and binding.
Notes contd... (v) In case the nature of job is such that the work cannot be completed within a period of 6 hrs then the same shall be brought to the notice of the GE/Engr-in-Charge and the period for the completion of the complaint shall be decided by the GE/EIC. (vi) Contractors representative/Engineer will report to JE E/M in charge or AGE E/M at fore noon to collect routine/urgent works till completion of work. (vii) The transportation/ T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.
M&L for preparation of old painted body surface of LT indoor/out door panel / feeder piller box and spray painting with two coat of synthetic enamel paint as per existing colour to inside and outside of the body of LT panel as directed by the Engr-in -Charge complete all as specified and directed.
Supply and fix in repairs cable jointing kit for 1100 volt (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25-50 sq mm
Supply and fix in repairs cable jointing kit for 1100 volt (Earthed) grade cable for End Termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70-150 sq mm
Supplying and laying in repairs synthetic Rubber insulated mats 2.5mm thick for voltage up to 11KV for electrical purpose as per IS 15652-2006 (Superseding IS 5424) suitable for electrical shock safety of size 2m x1m all as specified and directed.
Supply and fix in repair digital type voltmeter 0-500 volt 96x96 mm square type all as directed and specified
Supply and fix in repair digital type ammeter 0-400 amp 96x96 mm square type all as directed and specified
Supply and fix in repair digital type ammeter 0-200 amp 96x96 mm square type all as directed and specified
Supply and fix in repair digital type ammeter 0-100 amp 96x96 mm square type all as directed and specified
Supply and fix in repair CT 400/5, copper wounded with suitable wiring for digital type ammeter for 3 phase connection all as specified and directed.
Supply and fix in repair CT 200/5, copper wounded with suitable wiring for digital type ammeter for 3 phase connection all as specified and directed.
Supply and fix in repair CT 100/5, copper wounded with suitable wiring for digital type ammeter for 3 phase connection all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 63A, 3 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 100A, 3 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 63A, 4 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 100A, 4 pole, breaking capacity 10KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 200A, 4 pole, breaking capacity 35KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair MCCB fixed thermal and fixed magnetic type of current rating 250A, 4 pole, breaking capacity 35KA, rated service short circuit breaking capacity 100% in existing LT panel all as specified and directed.
S&F in repair on load change over switch 100A, 4 Pole all as specified and directed.
M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
S L ELECTRICAL WORKS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .