| 1 | L1₹5.6 LAccepted-AOC NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | ₹5.6 L | L1 | Accepted-AOC L1 |
| Sl No | Description | Qty | Unit | Eastern Commerce L1 |
|---|---|---|---|---|
| 1.00 | Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 2 | Nos | 51,000 ₹1,02,000 Lowest |
| 2.00 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units 2 TR AC beyond the standard length as per direction of the Engineer-in-Charge. | 12 | Mtr | 800 ₹9,600 Lowest |
| 3.00 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. | 10 | Mtr | 90 ₹900 Lowest |
| 4.00 | Providing & Fitting fixing of 1" UPVC drain pipe as per direction of the Engineer-in-Charge. | 40 | Mtr | 95 ₹3,800 Lowest |
| 5.00 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle(or manufacturer Standard Design) of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 2 | Nos | 900 ₹1,800 Lowest |
| 6.00 | Standard installation of 2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge. | 2 | Nos | 1,880 ₹3,760 Lowest |
| 7.00 | Providing of Vertical split AC unit of cooling capacity not less than 13000 watt and 3 Star of latest standard with hermitically sealed compressor operating on R22/R-410 A /non CFC equivalent refrigerants suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) cooling, B) Dehumidify, C) Air circulation, d) Filtering. etc. complete as per direction of Engineer -in- charge. | 2 | Job | 1,57,900 ₹3,15,800 Lowest |
| 8.00 | installation and commissioning of 4 TR vertical split AC unit with vaccumising, Nitrogen pressure testing, first charge of refrigerant including providing Refrigerant & cable connection from MCB to Outdoor/indoor along with electrical Top etc. (upto 3mtr) complete as per direction of the Engineer in Charge . | 2 | Job | 4,900 ₹9,800 Lowest |
| 9.00 | Providing & installation of Hard Drawn copper piping with insulation for vertical split AC 3/4" (or manufacturer standard size)OD/applicable or OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge. | 24 | Mtr | 1,700 ₹40,800 Lowest |
| 10.00 | Providing & installation of Hard Drawn copper piping with insulation for vertical split AC. 1/2" OD(or manufacturer standard size) / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge. | 24 | Mtr | 1,600 ₹38,400 Lowest |
Tender Value
₹5.8 L
EMD Value
₹11,540
Closing Date
5 Jun 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division
Providing Installation Commissioning2TR HighWall Split Air Conditioning Unit the Green Room Backside Stage Hall I 4 TR Vertical Split Air Conditioning Unit for the Stage Hall II at Rabindra Satabarshiki Bhavan Agartala
2026_CEPWD_73192_1
28 _EE__DNIeT_MECH.DIVN _2627
Open Tender
Electrical Works
Works
180 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹11,540
24 Aug 2026
22 May 2026
5 Jun 2026
22 May 2026
5 Jun 2026
22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of Split type Hi wall 2.00 TR(rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC supply including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unitin/c batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 2 | Nos | - | - |
| 2 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units 2 TR AC beyond the standard length as per direction of the Engineer-in-Charge. | 12 | Mtr | - | - |
| 3 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. | 10 | Mtr | - | - |
| 4 | Providing & Fitting fixing of 1" UPVC drain pipe as per direction of the Engineer-in-Charge. | 40 | Mtr | - | - |
| 5 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle(or manufacturer Standard Design) of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 2 | Nos | - | - |
| 6 | Standard installation of 2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge. | 2 | Nos | - | - |
| 7 | Providing of Vertical split AC unit of cooling capacity not less than 13000 watt and 3 Star of latest standard with hermitically sealed compressor operating on R22/R-410 A /non CFC equivalent refrigerants suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) cooling, B) Dehumidify, C) Air circulation, d) Filtering. etc. complete as per direction of Engineer -in- charge. | 2 | Job | - | - |
| 8 | installation and commissioning of 4 TR vertical split AC unit with vaccumising, Nitrogen pressure testing, first charge of refrigerant including providing Refrigerant & cable connection from MCB to Outdoor/indoor along with electrical Top etc. (upto 3mtr) complete as per direction of the Engineer in Charge . | 2 | Job | - | - |
| 9 | Providing & installation of Hard Drawn copper piping with insulation for vertical split AC 3/4" (or manufacturer standard size)OD/applicable or OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge. | 24 | Mtr | - | - |
| 10 | Providing & installation of Hard Drawn copper piping with insulation for vertical split AC. 1/2" OD(or manufacturer standard size) / applicable OD based on manufacturer guideline etc. complete as per direction of Engineer -in- charge. | 24 | Mtr | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_74491.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
DNIT.pdf
Tender Documents • 2.96 MB
BOQ_74491.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .