Construction of 14 Court Building complex at Bhimavaram, West Godavari District (A.P) : Package IA -RCC structures , Civil finishing works with internal electrical works
NBCC/RBG/South/Bhimavaram/WestGodavari/2026/19
NBCC/RBG/South/Bhimavaram/WestGodavari/2026/19
Open Tender-Domestic
Civil Works General
West Godavari, Andhra Pradesh
₹1.2 L
₹57.1 L
1 Jun 2026
18 May 2026
1 Jun 2026
1 Jun 2026
Providing and laying in position cement concrete of
20 4.1 specified grade excluding the cost of centering and - - -
shuttering - All work up to plinth level :
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived
21 4.1.6 from natural sources : 6 graded stone Cum 40.30 7,178.75 2,89,303.63 - -
aggregate 40 mm nominal size derived from natural
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived
22 4.1.8 from natural sources : 8 graded stone aggregate 40 Cum 230.00 6,812.00 15,66,760.00 - -
mm nominal size derived from natural sources)
1:5:10 (1 Cement : 4 coarse sand (zone-III) derived
23 4.1.10 from natural sources : 8 graded stone aggregate 40 Cum 10.00 6,518.60 65,153.41 - -
mm nominal size derived from natural sources)
Providing and fixing up to floor five level precast
cement concrete string or lacing courses,
copings, bed plates, anchor blocks, plain
24 4.5 window sills, shelves, louvers, steps, stair - - -
cases, etc., including hoisting and setting in
position with cement mortar 1:3 (1 Cement : 3
coarse sand), cost of required
Centering complete.
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)
derived from natural sources : 3 graded stone
aggregate 20mm nominal size derived from
Making plinth protection 50mm thick of cement
concrete 1:3:6 (1 cement : 3 coarse sand (zone-III)
derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from natural
sources) over 75mm thick bed of dry brick ballast
40 mm nominal size, well rammed and consolidated
and grouted with fine sand, including necessary
excavation, levelling & dressing & finishing the top
Total Carried over to summary 21,89,938.90 - -
Providing and laying in position ready mixed or site
batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and
fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland
Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard
setting of concrete, to improve durability and
workability without impairing strength; including
27 pumping of concrete to site of laying, curing, - - -
carriage for all leads; but excluding the cost of
centering, shuttering, finishing and reinforcement
as per direction of the engineer-in-charge; for the
following grades of concrete.
Note: Extra cement up to 10% of the minimum
specified cement content in design mix shall be
payable separately. In case the cement content in
design mix is more than 110% of the specified
minimum cement content, the contractor shall have
28 5.33.1 All works upto plinth level - - -
Concrete of M30 grade with minimum cement
content of 350 kg /cum
30 5.33.2 All works above plinth level upto floor V level - - -
Concrete of M30 grade with minimum cement
content of 350 kg /cum
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V
32 5.38 level for each four floors Cum 829.03 355.65 2,94,844.88 - -
or part thereof.
Centering and shuttering including strutting,
33 5.9 propping etc. and removal of - - -
Foundations, footings, bases of columns, etc. for
Walls (any thickness) including attached pilasters,
35 5.9.2 butteresses, plinth and Sqm 196.08 842.50 1,65,197.40 - -
string courses etc.
Lintels, beams, plinth beams, girders, bressumers
and cantilevers
37 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 8,325.42 961.30 80,03,226.25 - -
38 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 114.29 764.95 87,422.86 - -
Small lintels not exceeding 1.5 m clear span,
39 5.9.15 moulding as in cornices, Sqm 204.00 392.15 79,998.60 - -
window sills, string
40 5.9.19 Weather shed, chajjas, corbels etc., including edges Sqm 116.00 951.10 1,10,327.60 - -
Suspended floors, roofs, landings, balconies and
access platform.
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Extra for additional height in centering,
shuttering where ever required with
42 5.11 adequate bracing, propping etc., including cost - - -
of de-shuttering and decentering at all levels,
over a height of 3.5 m, for every additional
height of 1 metre or part thereof (Plan area to
Suspended floors, roofs, landings, beams and
43 5.11.1 balconies (Plan area to be Sqm 3,713.40 384.30 14,27,059.62 - -
Reinforcement for R.C.C. work including
44 5.22 straightening, cutting, bending, - - -
placing in position and binding all complete upto
45 5.22.6 Thermo-Mechanically Treated bars. Kg 8,25,995.56 107.85 8,90,83,620.85 - -
Steel reinforcement for R.C.C. work including
46 5.22A straightening, cutting, bending, placing in position - - -
and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-
Providing and fixing of expansion joint system
related with floor location as per drawings and
direction of Engineer-In-Charge. The joints system
will be of extruded aluminum base members, self
aligning / self centering arrangement and support
plates etc. as per ASTM B221-02. The system shall
be such that it provides floor to floor /floor to wall
expansion control system for various vertical
localtion in load application areas that
accommodates multi directional seismic movement
without stress to it’s components.
System shall consist of metal profiles with an
universal aluminum base member designed to
48 5.44 accommodate various project conditions and finish - - -
floor treatments. The cover plate shall be designed
of width and thickness required to satisfy projects
movement and loading requirements and secured
to base members by utilizing manufacturer’s pre-
engineered self- centering arrangement that freely
rotates / moves in all directions. The Self - centering
arrangement shall exhibit circular sphere ends that
lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and
flexure in all directions including vertical
Provision of Moisture Barrier Membrane in the
Joint System to have watertight joint is mandatory
49 requirement
5.44.3 floor Joint of all
the manufactures design and Rmt 170.00 9,903.65 16,83,620.50 - -
Providing and fixing of expansion joint system
related with wall joint (internal/external) location
as per drawings and direction of Engineer-In-
Charge. The joints shall be of extruded aluminum
base members, self aligning / centering
arrangement and support plates as per ASTM B221-
02. The material shall be such that it provides an
50 5.45 Expansion Joints System suitable for vertical wall to - - -
wall/ wall to corner application, both new and
existing construction in office Buildings &
complexes with no slipping down tendency
amongst the components of the Joint System. The
Joint System shall utilize light weight aluminum
profiles exhibiting minimal exposed aluminum
surfaces mechanically snap locking the multicellular
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing of expansion joint system of
approved make and manufactures for various roof
locations as per approved drawings and direction of
Engineer-in-charge. the joints shall be of extruded
aluminum base members with, self aligning and self
centering arragement support plates as per AStm
B221-02. the system shall be such that it provides
watertight roof to roof/roof to corner joint cover
expansion control system that is capable of
accommodating multidirectional seismic movement
without stress to its components. System shall
52 5.46 consist of metal profile that incorporates an - - -
universal aluminum base member designed to
accommodate various project conditions and roof
treatments. the cover plate shall be designed of
width and thickness required to satisfy movement
and loading requirements and secured to base
members by utilizing manufacturer’s pre-
engineered self-centering arrangement that freely
rotates / moves in all directions. the Self centering
arrangement shall exhibit circular sphere ends that
lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and
the Joint System shall resists damage or
deterioration from the impact of falling ice,
exposure of moisture Barrier membrane in the
53 Joint System to have water tight joint is - - -
mandatoryto UV, airborne contaminants and
occasional foot traffic from maintenance personnel.
54 5.46.2 Provision
roof Joint requirement.
of 150 mm gap (material shall conform to Rmt 145.00 6,699.85 9,71,478.25 - -
Total Carried over to summary 25,19,46,970.64 -
Brick work with common burnt clay F.P.S. (non
55 6.1 modular) bricks of class - - -
designation 7.5 in foundation and plinth in:
56 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 66.38 7,132.25 4,73,403.09 - -
Providing and laying Autoclaved Aerated
concrete(AAC) blocks masonry with 150mm to 300
mm thick with Grade-1 AAC blocks of density 551 to
650 kg/cum conforming to IS:2185 (Part 3) in super
57 6.47 structure above plinth level up to floor V level with - - -
RCC band at sill level and lintel level with approved
block laying polymer modified adhesive mortar all
complete as per direction of Engineer-in-Charge.
(The payment of RCC band and reinforcement shall
Extra for brick work / AAC block masonry / Tile brick
59 6.5 masonry in superstructure above floor V level, for Cum 686.00 169.45 1,16,242.70 - -
each four floors or part thereof by
mechanical means.
Extra for half brick masonry in superstructure,
60 6.14 above floor V level for every Sqm 794.00 104.80 83,211.20 - -
four floors or part thereof by mechanical means.
Extra for providing and placing in position 2 Nos
third course of half brick masonry.
Total Carried over to summary 3,38,68,888.55 - -
Providing and fixing 18 mm thick gang saw cut,
mirror polished, premoulded and prepolished,
machine cut for kitchen platforms, vanitycounters,
window sills, facias and similar locations of required
size,approved shade, colour and texture laid over
20 mm thick base cementmortar 1:4 (1 cement : 4
coarse sand), joints treated with white
cement,mixed with matching pigment, epoxy touch
ups, including rubbing, curing,moulding and
polishing to edges to give high gloss finish etc.
63 8.2.2 Granite stone slab colour black, Cherry/Ruby red - - -
Providing edge moulding to 18 mm thick marble
stone counters, Vanities etc., including machine
66 8.3 polishing to edge to give high gloss finish etc. - - -
complete as per design approved by Engineerin-
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing dry cladding upto 10 metre
heights with 30mm thick gang saw cut stone with
(machine cut edges) of uniform colour and size
upto 1mx1m, fixed to structural steel frame work
and/ or with the size upto 1mx1m, fixed to
structural steel frame work and/ or with the help of
cramps, pins etc. and sealing the joints with
approved weather sealant as per Architectural
drawing and direction of Engineer-in-charge.(The
steel frame work, stainless steel cramps and pins
69 8.20.1 Red sand stone - 30mm thick gang saw cut stone Sqm 630.00 2,902.65 18,28,669.50 - -
Extra for stone work for wall lining on exterior walls
70 8.19 of height more than 10 m from ground level for Sqm 472.50 165.85 78,364.13 - -
every additional height of 3 m or part there of
Providing and fixing structural steel frame (for dry
cladding with 30 mm
thick gang saw cut with machine cut edges sand
stone) on walls at all heights using M.S. square/
rectangular tube in the required pattern as per
architectural drawing, including cost of cutting,
bending, welding etc. The frame work shall be fixed
to the wall with the help of M.S brackets/ lugs of
angle iron/ flats etc. which shall be welded to the
frame and embedded in brick wall with cement
concrete block 1:2:4 (1cement :2 coarse sand :4
graded stone aggregate 20 mm nominal size) of size
71 8.21 300x230x300 mm, including cost of necessary Kg 5,040.00 269.95 13,60,548.00 - -
centring and shuttering and with approved
expansion hold fasteners on CC/RCC surface,
including drilling necessary holes. Approved
cramps/ pins etc.shall be welded to the frame work
to support stone cladding, the steel work will be
given a priming coat of Zinc primer as approved by
Engineer in-charge and painted with two or more
coats of epoxy drawings shall be submitted by the
contractor to the Engineer-in-chargepaint (Shop for
approval before execution). The frame work shall
be fixed in true horizontal & vertical lines/planes.
(Only structural steel frame work shall be measured
Providing and fixing adjustable stainless steel
cramps of approved quality,required shape and
size, adjustable with stainless steel nuts, bolts and
washer (total weight not less than 260 gms), for dry
stone cladding fixed on frame work at suitable
location, including making necessary recesses in
stone slab, drilling required holes etc complete as
per direction of the
Engineer-in-charge.
Total Carried over to summary 60,38,486.43 - -
WOOD & PVC WORK
Providing wood work in frames of doors, windows,
clerestory windows and other frames, wrought
73 9.1 framed and fixed in position with hold fast lugs or - - -
with dash fasteners of required dia & length ( hold
fast lugs or dash fastener
shall be paid for separately).
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
75 9.2 decorative type, core of block board - - -
construction with frame of 1st class hard wood
and well matched teak 3 ply veneering with
vertical grains or cross bands and face veneers
35 mm thick including ISI marked Stainless
Steel butt hinges with necessary
77 9.7.7 Float glass panes - - -
5.0 mm thick glass panes (weight not less than
Providing and fixing wooden moulded beading to
79 9.40.1 door and window frames with iron screws, plugs - - -
and priming coat on unexposed surface etc.
Providing & fixing Anchor Fastners of 200 mm long
81 M.R to frame with 10 mm diameter bolts, nuts and Each 12.00 232.00 - - 2,784.00
plugs and embedding in cement concrete.
Providing and fixing aluminium sliding door bolts,
ISI marked anodised (anodic coating not less than
82 9.96 grade AC 10 as per IS : 1868), transparent or dyed Each - - -
to required colour or shade, with nuts and screws
etc. complete :
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing aluminium tower bolts, ISI
marked, anodised (anodic coating not less than
84 9.97 grade AC 10 as per IS : 1868 ) transparent or dyed - - -
to required colour or shade, with necessary screws
etc. complete :
Providing and fixing aluminium handles, ISI marked,
anodised (anodic coating not less than grade AC 10
86 9.1 as per IS : 1868) transparent or dyed to required - - -
colour or shade, with necessary screws etc.
Providing and fixing aluminium hanging floor door
stopper, ISI marked, anodised (anodic coating not
88 9.101 less than grade AC 10 as per IS : 1868) transparent - - -
or dyed to required colour and shade, with
necessary screws
89 9.101.1 Single rubber stopper Each 4.00 39.60 158.40 - -
Providing and fixing factory made uPVC glazed/wire
mesh windows/doors comprising of lead free uPVC
multi-chambered frame, sash and mullion/coupler
(where ever required) extruded profiles having
minimum wall thickness of 1.70 mm for Series R1
and R2 profiles and 2.10 mm for Series R3 and R4
profiles conforming to EN: 12608 in any shape,
colour and design duly reinforced with galvanized
mild steel section made of required shape & size as
per CPWD Specification, uPVC extruded glazing
beads, interlocks and Inline sash adaptor (where
ever required) of appropriate dimension, EPDM
gasket, hardware, SS 304 grade fasteners of
minimum 8 mm dia with countersunk head,
comprising of matching polyamide PA6 grade sleeve
for fixing frame to finished wall as per IS 1367 : Part
1 to 14, plastic packers, plastic caps and necessary
stainless steel screws etc. Profile of frame, sash &
90 9.147A mullion (if required) shall be mitred cut and fusion - - -
welded/mechanically jointed duly sealed at all
corners, including drilling of holes for fixing
hardware and drainage of water etc. After fixing
frame the gap between frame and adjacent finished
wall shall be filled with weather proof silicon
sealant over backer rod of approved size and
quality, all complete as per approved drawing
conforming to CPWD specification & direction of
Engineer-in-Charge. Section of steel reinforcement
and cross sections of uPVC profiles to be as per
design approved by Engineer-in- Charge. Wire mesh
/ Glazing of plain/ toughened/ laminated/ double
glass unit with / without high performance coatings
as per design requirements and conforming to IS:
3548 & IS: 16231 shall be paid separately.
Note:- Structural design proof checked from a
Government Engineering Institute, to be provided
by the manufacturer for : (i) Sites with basic wind
Three track three panels sliding window with two
91 9.147.A4 glazed & one wire mesh panels with Aluminium - - -
channel for roller track, wool pile, nylon rollers with
Using R3 series with frame (98mm & above) x
9.147.A4. (40mm & above) & both
2 glazed and fly screen every glazed panel along with
multi-point locking system. (Height upto 1.8m).
Using R3 series with frame (55mm & above) x
(40mm & above) & sash (30mm & above) x (55mm
9.147.A1. & above) with zinc alloy (zamak) powder coated
2 handle on every panel along with multi-point
locking system (Height upto
94 9.147.C1 Fixed window / ventilator without mullion / - - -
9.147.C1. Using R1 series with frame (33mm & above ) x
upto 0.90 metre)
Providing and fixing M.S. grills of required pattern in
frames of windows etc.
96 9.48 with M.S. flats, square or round bars etc. including - - -
priming coat with approved steel primer all
97 9.48.1 Fixed to steel windows by welding Kg 45,024.00 219.10 98,64,758.40 - -
Total Carried over to summary 3,11,28,802.41 - 2,784.00
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
98 10.16 including cutting, hoisting, fixing in position and - - -
applying a priming coat of approved steel
primer, including welding and bolted with
special shaped washers etc. complete.
99 10.16.1 Hot finished welded type tubes Kg 300.00 - - -
eel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in
100 10.25 position and applying a priming coat of - - -
approved steel primer using
structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings,
brackets, gates and similar w
Providing and fixing stainless steel ( Grade 304)
railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and
making curvature (wherever required) and fitting
the same with necessary stainless steel nuts and
bolts complete, i/c fixing the railing with necessary
accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on the top
of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-incharge,
(for payment purpose only weight of stainless steel
members shall be considered excluding fixing
Total Carried over to summary 17,61,072.00 - -
Providing and laying Vitrified tiles in floor in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved
brand & manufacturer, in all colours and shade, laid
on 20 mm thick cement mortar 1:4 (1 cement: 4
103 11.41A coarse sand) jointing with grey cement slurry @3.3 - - -
kg/sqm including grouting the joints with white
cement and matching pigments etc. The tiles must
be cut with the zero chipping diamond cutter only .
Laying of tiles will be done with the notch trowel,
plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently
104 11.41A.1 Double Charged Vitrified tile Polished Finish of Size - - -
Providing and laying Vitrified tiles in different sizes
(thickness to be specified by manufacturer), with
water absorption less than 0.08 % and conforming
I.S. 15622, of approved make, in all colours &
shade, in skirting, riser of steps, over 12 mm thick
bed of cement mortar 1:3 (1 cement: 3 coarse
sand), jointing with grey cement slurry @ 3.3 kg/
11.46.2 Size including grouting
Tile 600x600 mmthe joint with white cement Sqm 972.00 1,623.05 15,77,604.60 - -
Chequered terrazo tiles 22 mm thick with graded
marble chips of size up to 6 mm in floors, jointed
108 11.19 with neat cement slurry mixed with pigment to - - -
match the shade of the tiles, including rubbing and
polishing complete, on 20 mm thick bed of cement
mortar 1:4 (1 cement :4 coarse sand) :.
109 11.19.1 Light shade pigment using white cement Sqm 1,533.80 - - -
Providing and laying rectified Glazed Ceramic floor
tiles of size 300x300 mm or more (thickness to be
specified by the manufacturer), of 1st quality
conforming to IS : 15622, of approved make, in
colours White, Ivory, Grey, Fume Red Brown, laid
on 20 mm thick cement mortar 1:4 (1 Cement: 4
Coarse sand), jointing with grey cement slurry @
3.3 kg/ sqm including grouting the joints with white
andmatching pigments
laying flamed etc.,
finish complete
flooring in required design and patterns, in linear as
well as curvilinear portions of the building all
complete as per the architectural drawings with 18
mm thick stone slab over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with cement slurry and
pointing with white cement slurry admixed with
pigment of matching shade including rubbing,
curing and polishing etc. all complete as specified
Flamed finish granite stone slab Jet Black, Cherry
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and laying Polished Granite stone flooring
in required design and patterns, in linear as well as
curvilinear portions of the building all complete as
per the architectural drawings with 18 mm thick
stone slab over 20 mm (average) thick base of
113 11.56 cement mortar 1:4 (1 cement : 4 coarse sand) laid - - -
and jointed with cement slurry and pointing with
white cement slurry admixed with pigment of
matching shade including rubbing, curing and
polishing etc. all complete as specified and as
directed by the Engineer-in-
Polished Granite stone slab of colour Black,
Cherry/Ruby Red or equivalent
Providing and fixing Ist quality ceramic glazed
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
115 8.31 Engineer-in-Charge, in skirting, risers of steps Sqm 2,408.00 1,267.95 30,53,223.60 - -
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.
Total Carried over to summary 2,74,42,211.65 - -
Providing and fixing mineral fibre false ceiling tiles
at all heights of size 595X595mm of approved
texture, design and pattern. The tiles should have
Humidity Resistance (RH) of 99%Light Reflectance ≥
85%, Thermal Conductivity k = 0.052 - 0.057 w/m K,
Fire Performance as per (BS 476 pt - 6 &7)in true
horizont al level suspended on interlocking T-Grid
of hot dipped all round galvanized iron section of
0.33 mm thick (galvanized @120 gsm) comprising
of main T runners of 15x32 mm of length 3000 mm,
cross T of size 15x32mm of length 1200 mm and
secondary intermediate cross T of size 15x32 mm of
length 600 mm to form grid module of size 600x600
mm suspended from ceiling using galvanized mild
steel item (galvanised@80gsm) 50 mm long 8mm
outer diameter M-6 dash fasteners, 6 mm diameter
fully threaded hanger rod up to 1000 mm length
and L- shape level adjuster of size 85x25x2 mm,
spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls
/partitions with the help of GI perimeter wall angle
of size24x24X3000 mm made of
0.40 mm thick sheet, to be fixed to the wall with
help of plastic rawl plug at 450 mm centre to centre
& 40 mm long dry wall S.S.screws. The exposed
bottom portion of all T-sections used in false ceiling
support system shall be pre-painted with polyester
baked paint, for all heights. The work shall be
mmasthick beveled tegular mineral fibre
117 26.27.1 false ceiling tile (NRC 0.55 to - - -
Providing corrugated G.S. sheet roofing including
vertical / curved surface fixed with polymer coated J
or L hooks, bolts and nuts 8 mm diameter with
bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of
approved steel primer and two coats of approved
paint on overlapping of sheets complete (up to any
pitch in horizontal/ vertical or curved surfaces),
excluding the cost of purlins, rafters and trusses
and including cutting to size and shape wherever
0.80 mm thick with zinc coating not less than 275
Providing and fixing 15 cm wide, 45 cm overall semi-
circular plain G.S. sheet gutter with iron brackets
120 12.7 40x3mm size, bolts, nuts and washers etc., - - -
including making necessary connections with rain
water pipes complete.
0.80 mm thick with zinc coating not less than 275
Total Carried over to summary 2,42,81,285.45 - -
122 13.16 6 mm cement plaster of mix : - -
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
15 mm cement plaster on rough side of single or
half brick wall of mix:
128 13.6 20 mm cement plaster of mix : - - -
Polishing in high gloss/matt finish melamine clear
required color/wooden shade texture
Providing and applying plaster of paris putty of
131 13.26 2mm thickness over plastered surface to prepare Sqm 30,000.00 262.70 78,81,000.00 - -
the surface even and smooth complete.
Wall painting with premium acrylic emulsion paint
of interior grade, having VOC (Volatile Organic
132 13.83 Compound ) content less than 50 grams/ litre of - - -
approved brand and manufacture, including
applying additional coats wherever required to
achieve even shade and colour.
With water thinnable cement primer on wall
134 13.85.3 surface having VOC content Sqm 8,034.00 73.95 5,94,114.30 - -
less than 50 grams/litre
Finishing walls with Premium Acrylic Smooth
135 13.47 exterior paint with Silicone additives of required - - -
New work (Two or more coats applied @ 1.43 ltr/10
136 13.47.1 sqm over and including priming coat of Sqm 6,527.00 171.10 11,16,769.70 - -
exterior primer applied @ 0.90 litre/10 sqm)
Painting on G.S. sheet with synthetic enamel paint
137 13.53 of approved brand and - - -
manufacture ofrequired colour to give an even
New work (two or more coats) including a coat of
138 13.53.1 approved steel primer but Sqm 1,592.00 180.85 2,87,913.20 - -
excluding a coat of mordant solution
Total Carried over to summary 3,39,02,988.92 - -
WATERPROOFING WORK
Providing impervious coat to RCC roof slab required
slopes with CM (173) prop. 20tnm thick (average)
mixed with 1 kg Of water proofing compound per
bag Cementt laid Over roof slab when it is green,
finished smooth with a floating coat of neat cement
and thread lining at regular intervals of 45cmx45cm
139 NDSR imluding cost conveyance of all materials like sand. Sqm 2,700.00 925.12 - - 24,97,824.00
water proofing compound, water etc., to site,
seigniorage charges. sales & other taxes on all
materials operational, incidental, and lat»ur charges
for mixing mortar, laying, lift charges. rendering
smooth and thread lining. curing including rounding
Off the wall and slab junction etc., complete for
finished item of work. for:-lmpervious coat CM(1
Providing and laying water proofing treatment in
sunken portion of WCs, bathroom etc., by applying
cement slurry mixed with water proofing cement
compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm
mixed with water proofing cement compound @
0.253 kg/ sqm. This layer will be allowed to air cure
(b) Second layer of slurry of cement @ 0.242
kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be
allowed to air cure for 4 hours followed with
water curing for 48 hours. The rate includes
preparation of surface, treatment and sealing of all
joints, corners, junctions of pipes and masonry
Total Carried over to summary 1,54,262.50 - 24,97,824.00
ALUMINIUM & GLASS WORK
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with extruded
built up standard tubular sections/ appropriate Z
sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including
necessary Filling up the gaps at junctions, i.e. at top,
141 21.1 bottom and sides with required EPDM rubber/ - - -
neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat
angle, Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing, paneling
142 21.1.1 For fixed portion - - -
Powder coated aluminium (minimum thickness of
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots and
144 21.1.2 making provision for fixing of fittings wherever - - -
required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall
be paid for separately)
Powder coated aluminium (minimum thickness of
Providing and fixing glazing in aluminium door,
window, ventilator shutters and partitions etc. with
146 21.3 EPDM rubber / neoprene gasket etc. complete as - - -
per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap
beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight
Total Carried over to summary 7,04,930.04 - -
STRUCTURAL GLAZING
Providing and supplying aluminium extruded
tubular and other aluminium sections as per the
architectural drawings and approved shop drawings
, the aluminium quality as per grade 6063 T5 or T6
as per BS 1474,including super durable powder
coating of 60-80 microns conforming to AAMA
2604 of required colour and shade as approved by
the Engineer-in-Charge. ( The item includes cost of
material such as cleats, sleeves, screws etc.
necessary for fabrication of extruded aluminium
frame work. Nothing extra shall be paid on this
account). The weight of aluminium extruded
Designing, fabricating, testing, protection, installing
and fixing in position semi (grid) unitized system of
structural glazing (with open joints) for linear as
well as curvilinear portions of the
building for all heights and all levels, including:
(a) Structural analysis & design and preparation of
shop drawings for the specified design loads
conforming to IS 875 part III (the system must
passed the proof test at 1.5 times design wind
pressure without any failure), including functional
design of the aluminum sections for fixing glazing
panels of various thicknesses, aluminium cleats,
sleeves and splice plates etc. gaskets, screws,
149 toggles, nuts, bolts, clamps etc., structural and - - -
weather silicone sealants, flashings, fire stop
(barrier)-cum-smoke seals, microwave cured EPDM
gaskets for water tightness, pressure equalisation &
drainage and protection against fire hazard
(b) Fabricating and supplying serrated M.S. hot dip
galvanised / Aluminium alloy of 6005 T5 brackets of
required sizes, sections and profiles etc. to
accommodate 3 Dimentional movement for
achieving perfect verticality and fixing structural
glazing system rigidly to the RCC/ masonry/
structural steel framework of building structure
using stainless steel anchor fasteners/ bolts, nylon
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
(c) Providing and filling, two part pump filled,
structural silicone sealant and
one part weather silicone sealant compatible with
the structural silicone sealant of required bite size
in a clean and controlled factory / work shop
environment, including double sided spacer tape,
setting blocks and backer rod, all of approved
grade, brand and manufacture, as per the approved
sealant design, within and all around the perimeter
for holding glass.
(d) Providing and fixing in position flashings of solid
aluminium sheet 1 mm thick and of sizes, shapes
and profiles, as required as per the site conditions,
to seal the gap between the building structure and
all its interfaces with curtain glazing to make it
(e) Making provision for drainage of moisture/
water that enters the curtain glazing system to
150 25.2 make it watertight, by incorporating principles of - - -
pressure equalization, providing suitable gutter
profiles at bottom (if required), making necessary
holes of required sizes and of required numbers etc.
complete. This item includes cost of all inputs of
designing, labour for fabricating and installation of
aluminium grid, installation of glazed units, T&P,
scaffolding and other incidental charges including
wastages etc., enabling temporary structures and
services, cranes or cradles etc. as described above
and as specified. The item includes the cost of
getting all the structural and functional design
including shop drawings checked by a structural
designer, dully approved by Engineer-in-charge. The
item also includes the cost of all mock ups at site,
cost of all samples of the individual components for
testing in an approved laboratory,
field tests on the assembled working structural
glazing as specified, cleaning and protection till the
Note:-2. The following performance test are to be
conducted on structural glazing system if area of
structural glazing exceeds 2500 Sqm from the
certified laboratories accreditated by NABL(National
Accreditation Board for Testing and Calibration
Laboratories), Department of Science &
Technologies, India. Cost of testing is payable
separately. The NIT approving authority will decide
the necessity of testing on the basis of cost of the
work, cost of the test and importance of the work.
Performance Testing of Structural glazing system
Tests to be conducted in the NABL accredited lab or
any other accreditation body which operates in
accordance with ISO/IEC 17011 and accredits labs
as per ISO/IEC 17025
151 1. Performance Laboratory Test for Air Leakage Test Sqm 162.00 3,510.50 5,68,701.00 - -
(-50pa to - 300pa) & (+50pa to +300pa) as per
ASTM E-283-04 testing method for a range of
testing limit 1 to 200 mVhr
2. Static Water Penetration Test. (50pa to 1500pa)
as per ASTME- 331-09 testing method for a range
3. Dynamic Water Penetration (50pa to 1500pa) as
per AAMA 501.01- 05 testing method for a range
4. Structural Performance Deflection and
deformation by static air pressure test (1.5 times
design wind pressure without any failure) as per
ASTME-330- 10 testing method for a range upto 50
5. Seismic Movement Test (upto 30 mm) as per
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing, assembling and supplying vision glass
panels (IGUs) comprising of hermetically-sealed 6-
12- 6 mm insulated glass (double glazed) vision
panel units of size and shape as required and
specified, comprising of an outer heat strengthened
float glass 6mm thick, of approved colour and
shade with reflective soft coating on surface # 2 of
approved colour and shade, an inner Heat
strengthned clear float glass 6mm thick, spacer
tube 12mm wide,dessicants, including primary seal
and secondary seal (structural silicone sealant) etc.
all complete for the required performances, as per
the Architectural drawings, as per the approved
shop drawings, as specified and as directed by the
Engineer-in-Charge. The IGUs shall be assembled in
the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain
glazing is included in cost of item No.25.2) For
payment, only the actual area of glass on face # 1 of
the glass panels (excluding the areas of the grooves
(i) Coloured tinted float glass 6mm thick substrate
with reflective soft coating on face # 2, + 12mm
Airgap + 6mm Heat Strengthened clear Glass of
approved make having properties as visible Light
153 transmittance (VLT) of 25 to 35 %, Light reflection Sqm 162.00 3,718.70 6,02,429.40 - -
internal 10 to 15%, lightreflection external 10 to
20 %, shading coefficient (0.25- 0.28) and U value of
3.0 to 3.3 W/m2 degree K etc. The properties of
performance glass shall be decided by technical
Providing and Fixing of GRC Jali (Glass Fibre
Reinforced Jali) 50 mm thick of required size,
pattern, design, and colour with 50% area covered
154 M.R to be fixed on/between RCC / Block work Column or Sqm 143.64 5,369.00 - - 7,71,203.16
structural steel work with Dry Fixing method.
Pattern and design as approved by
Architect/Engineer-In-
Design, supply, fabrication and fixing of Signage
board using words made of acrylic cut out letters
with LED and reflective vinyl sheet as per approved
design with following specification.Board shall be
fabricated with 3 mm thick ACP sheets of approved
make. Powder coated Aluminium sheet shall be
fixed from the rear side of the entire board to make
box section. Logo letters (Telegu and English) shall
be made of Acrylic cutout letters of approved make
and shall be uniformly illuminated by using Digital
LED light of approved make. Powder coated
155 M.R Aluminum clips and brackets shall be used of LS 1.00 10,00,000.00 - - 10,00,000.00
minimum 3 mm thickness as per direction of
Engineer In charge.
Words of other matter of the signage board shall be
fixed using reflective vinyl cutout letters of
approved make. Lumpsum rate to be quoted for
following signages
1) "District Court Complex Bhimavaram" (In English)
Size: 2ft X 18ft
2) "District Court Complex Bhimavaram" (In Telegu)
Size: 2ft X 18ft
3) Logo of Ashoka Chakra as shown in the elevation
Total Carried over to summary 18,42,296.40 - 17,71,203.16
BOQ - Plumbing & Sanitary
Providing and fixing white vitreous china extended
wall mounting water closet of size mm of approved
including providing & fixing white vitreous china
156 17.78 cistem with dual flush fifing, of flushing capacity 3 Each 124.00 14,999.15 18,59,894.60 - -
litre/ 6 litre (adjustable to 4 litre/ 8 litres), including
seat cover, and cistern fitings, nuts,
bolts and gasket
Providing etc wash
and fixing complete.
basin with C.I. brackets,
15 mm dia CP Brass single hole basin mixer of
157 17.7A approved quality and make. including painting of - - -
fittings and brackets, cutting and making good the
walls wherever required:-
White Vitreous China Wash basin size 550x400 mm
single hole basin mixer
Providing and fixing white vitreous china pedestal
159 17.8 for wash basin completely recessed at the back for Each 157.00 1,683.35 2,64,285.95 - -
the reception of pipes and fittings.
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing white vitreous china battery
based infrared sensor operated urinal of approx.
size 610 x 390 x 370 mm having pre & post flushing
160 17.80 with water (250 ml & 500 ml consumption), having Each 84.00 7,979.20 6,70,252.80 - -
water inlet from back side, including fixing to wall
with suitable brackets all as per manufacturers
Providing andand direction
fixing of Engineer-in-charge.
Urinal Division Plate with table
rubbed, edges rounded and polished, of size 900 x
450 mm, fixed in urinal partitions by cutting a chase
161 MR-1 of appropriate width with chase cutter and Each 84.00 6,546.16 - - 5,49,877.44
embedding the stone in the chase with epoxy grout
or with cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 6 mm nominal size)
as per direction
Providing of Engineer-in-charge
and fixing Stainless Steel A ISIand
kitchen Sink as per IS:13983 with C.I. brackets and
162 17.10 stainless steel plug 40 mm, including painting Of - - -
fittings and brackets, cutting and making good the
163 17.10.1 Kitchen sink with drain board - - -
Suplying and fixing of Waste Coupling – Full Thread
Range:Allied,Material:Brass,Description:Waste
Coupling – Full Thread 32MM
Providing and fixing CP Brass 32 mm size Bottle
166 17.22A Trap of approved quality & make and as per the Each 157.00 1,034.80 1,62,463.60 - -
direction of Engineer-in-charge.
Providing and fixing P.V.C. waste pipe for sink or
167 17.28 wash basin including P.V.C. - - -
waste fittings com lete.
Providing and fixing mirror of superior glass (of
approved quality) and of
169 17.32 required shape and size with plastic moulded frame - - -
of approved make and shade with 6 mm thick hard
171 17.34 Providing and fixing toilet paper holder : - - -
Providing and fixing C.P. brass angle valve for basin
mixer of approved quality conforming to IS:8931
Providing and fixing PTMT soap Dish Holder having
175 18.65 length of 138 mm, breadth 102 mm, height of 75 Each 157.00 111.45 17,497.65 - -
mm with concealed fitting arrangements,
weighing not less than 106 gms.
Providing and fixing SS grade 316 trapezoidal shape
215 mm long, 200 mm wide with minimum
176 MR-3 distances of 37 mm from wall face with concealed Each 157.00 231.95 - - 36,416.15
fittings arrangement of approved quality and
colour, weighing not less than
Providing of C.P Towel rack with all accessories as
177 MR-4 per approved specifications with 600 mm length, SS Each 32.00 2,877.41 - - 92,077.12
304, and making good the walls wherever required
Providing and fixing of 15 mm dia C.P. brass Pillar
178 cock with CP wall flange of approved quality with - - -
flow rate of 5 LPM complying to Green Building
180 For Sink - - -
Providing of C.P WALL MOUNTED SWIVEL SPOUT
KITCHEN SINK MIXER with
181 MR-6 all accessories as per approved specifications, Each 4.00 2,841.84 - - 11,367.36
Material: Brass,Mounted : Wall mounted,Series
Supplying of Health Faucet,
Material:Brass,Description:Health Faucet With Tube
182 MR-7 1 Meter & Hook,Finish:Chrome,Dimension Each 124.00 3,337.47 - - 4,13,846.28
Providing of C.P 2 WAY ANGLE COCK with Wall
183 MR-8 Flange and all accessories as per approved Each 124.00 2,105.16 - - 2,61,039.84
specifications, Material: Brass,Mounted : Wall
Supplying and fixing of Twin Coat Hook:Material:18-
steel,Application:WC Cubicle Area,Warranty:1 year.
Providing and fixing of FLOOR DRAIN WITH
185 MR-10 COCKROACH TRAP, Dimensions : 5X5 INCH, Shape: Each 285.00 1,852.67 - - 5,28,010.95
Square Flat Cut,Material: Stainless steel 304, Finish:
Gloss/Matt, Warranty : 1 Year
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing of FLOOR DRAIN WITH HOLE AND
186 MR-11 COCKROACH TRAP, Dimensions - 6X6 INCH, Each 74.00 1,923.98 - - 1,42,374.52
Material: Stainless steel 304,
Finish: Steel, Warranty : 1 Year
Supplying of HI SPEED HAND DRYER Construction :
Steel #304,Mounting : Wall Mounted, Operation :
187 MR-12 Automatic, Hand Dry Time : 9S ,Auto Cutoff : 60 Each 38.00 26,067.39 - - 9,90,560.82
seconds, Noise Leve : 60-70db, Motor : brush
motor, Speed : 30000r/min, Voltage : 220-240V,
Rated Power : 1000W, Current : 6A
Supplying of S.STEEL SOAP DISPENSER Container :
188 MR-13 18-8 S, Type-304, Stainless Steel Material : Non Each 38.00 3,744.33 - - 1,42,284.54
Corrosive Steel, Capacity : 190 ML
Providing and fixing of vitreous China Sanitary
fixtures and CP fitting and other accessories for
Handicapped toilet . Each Matrix Set shall
189 MR-14 comprised (Wash Basin 650 x 350 with one pair Each 12.00 16,467.76 - - 1,97,613.12
mounting brackets, EWC & Cistern complete with
fittings & seat cover, one no hinged rail 76 cm and
five no's ofand
Providing grab rails of
fixing 601cm).
No. complete all respect.
Swing Handicap Grab
190 MR-15 Bar - Stainless Steel at Each 12.00 12,787.65 - - 1,53,451.80
fixed height for handicap toilet complete as
Providing and fixing of 1 No. Stainless Steel Grab
191 MR-16 Barl (600 Mm),32mm Dia. at fixed height for Each 12.00 5,226.33 - - 62,715.96
handicap toilet complete as required.
Providing and fixing of 1 No. Stainless Steel Grab
192 MR-17 Bar (350 Mm),32mm Dia. at fixed height for Each 12.00 4,689.46 - - 56,273.52
handicap toilet complete as required.
INTERNAL AND EXTERNAL SERVICES
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass
threaded fittings and fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the
cost of cutting chases and making gocx:l the same
including testing of joints complete as per direction
of Engineerwork,
Concealed in Charge.
including cutting chases and
making the walls etc.
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass
198 18.9 threaded fittings This includes jointing of pipes & - - -
fittings with one step CPVC solvent cement,
trenching, refilling & testing of joints complete as
20 mmdirection of Engineer
nominal dia Pipes in Charge as per IS code Metre 352.00 274.30 96,553.60 - -
Providing and fixing gun metal non- return valve of
203 18.19 approved quality - - -
(screwed end) :
Providing, installation, testing and commissioning
-E&M- of stainless steel Y- strainer fabricated out of 1.6
2022/18 mm thick stainless steel, Grade 304, sheet with
3 mm dia holes with stainless steel flan e.
Providing and fixing gun metal gate valve with C.I.
wheel of approved quality screwed end
212 18.17.2 32 mm nominal bore. Each - 689.60
214 18.17.6 80 mm nominal bore Each - 2,604.55
Supplying, fixing, testing and commissioning of
DSR-E&M- butterfly valve of PN 1.6 rating with
215 2022// bronze/gunmetal seat duly ISI marked complete - - -
18.1 with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
Fixing Water meter and stop cock in G.I. pipe line
217 18.14 including cutting and threading the pipe and Each 4.00 812.30 3,249.20 - -
making long screws etc. complete (cost of water
meter and stop cock to be paid separately).
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing Cl- sluice valves (with cap)
218 18.31 complete with bolts, nuts, rubber insertions etc. - - -
(the tail pieces if required will be paid separately) :
Constructing masonry Chamber 60x60x75 cm
inside, in brick work in cement mortar (1 cement : 4
coarse sand) for sluice valve, with C.I- surface 100
mm top diameter, 160 mm bottom diameter and
180 mm deep ( inside) with chained lid and RCC top
slab 1 : 1.5:3 mix (1 cement : 1.5 coarse sand : 3
graded stone aggregate 20 mm nominal size),
including necessary excavation, foundation
concrete 1 (1 cement : 5 fine : 10 graded stone
aggregate 40 mm nominal size) and inside
plastering with cement mortar 1-- 3 (1 cement 3
coarse sand) 12 mm thick, finished with a floating
With common burnt clay EPS-(non modular) bricks
of class designation 7.5
Providing and fixing C.I. dirt box strainer for bulk
223 18.61 type water meter with nutsi bolts, rubber insertions - - -
etc. complete conforming to IS : 2373 :
DSR-E&M- Providing and fixing in position the industrial type
225 2022 pressure gauges with gun metal/ brass valves Each 40.00 1,196.00 47,840.00 - -
/16.8 complete as required
Piston Operated Screwed End Nitrile Rubber Bronze
226 / Gun Metal Body - - -
Pressure Reducing Valve Size
Providing and fixing,testing and commissioning of
228 expansion Bellow,Material Rubber and GI - - -
Flange,Thread Size As per customers requirement
Providing water level indicator or Automatic water
230 MR-20 Level Indicator with Each 14.00 7,533.23 - - 1,05,465.22
Musical Alarm on Tank Full and Buzzer on Tank
Providing and placing on terrace (at all floor levels)
polyethylene water storage
tank, IS : 12701 marked, with cover and suitable Per
231 18.48 locking arrangement and making 26,000.00 11.00 2,86,000.00 - -
necessary holes for inlet, outlet and overflow pipes
but without fittings and the
Providing andfor tank
fixing GI fabricated hot dipped
galvanized coating puddle flange comprising of 600
mm dia long M.S class 'C' pipe (screwed end up to
50 mm & flange for more than 50 mm dia) with 6
mm thick M.S plates of required size including
232 cutting holes in Centre of plate, inserting pipe & - - -
making welded (Arc) joint complete. Same shall be
installed with TEC welded joint in position with
reinforcement bars of RCC tank wall/slab including
making cutout in shuttering during concrete casting
of tank of following diameter.(For
SEWERAGE & DRAINAGE NETWORK
Providing, laying, jointing & testing of following
P.V.C. pipes with solvent cement joint for 8 kg/ sq.
237 cm. pressures including testing of joints, cost of - - -
jointing materials etc. complete in all respect.(class
238 Concealed work - - -
TOTAL AMOUNT - - 30,34,295.86
TOTAL AMOUNT - - 30,34,295.86
BOQ - Internal Electrical
A A DISTRIBUTION BOARDS
Supplying and fixing following way, single pole and
neutral, sheet steel, MCB distribution board, 240 V,
on surface/ recess, complete with tinned copper
243 2.3 bus bar, neutral bus bar, earth bar, din bar, - - -
interconnections, powder painted including
earthing etc. as required. (But without
244 2.3.2 MCB/RCCB/Isolator)
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Supplying and fixing following way, horizontal type
three pole and neutral, sheet steel, MCB
distribution board, 415 V, on surface/ recess,
245 2.4 complete with tinned copper bus bar, neutral bus - - -
bar, earth bar, din bar, interconnections, powder
painted including earthing etc. as required. (But
246 2.4.1 without
4 way (4MCB/RCCB/Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240
volts, 'C' series, miniature circuit breaker suitable
248 2.1 for inductive load of following poles in the existing - - -
MCB DB complete with connections, testing and
commissioning etc.
250 2.10.2 Single pole and neutral Each 29.00 599.00 17,371.00 - -
Supplying and fixing single pole blanking plate in
251 2.11 the existing MCB DB Each 30.00 13.00 390.00 - -
complete etc. as required.
Supplying and fixing following rating, double pole,
(single phase and neutral), 240 V, residual current
252 2.14 circuit breaker (RCCB), having a sensitivity current - - -
30 mA in the existing MCB DB complete with
connections, testing
and commissioning etc. as required.
Supplying, fixing, connecting, testing and
commissioning of following rating, ISI marked (IS
255 MR 8828) 240 / 415 volts, 10 KA, Miniature Circuit - - -
Breaker (MCB) of single / double / three / four poles
in the existing MCB DB or in existing MS enclosure
complete in all respects.
TOTAL CARRIED TO SUMMARY 7,28,155.00 - 90,317.00
Supply of XLPE insulated and PVC sheathed AL
259 armoured cable of 1.1 KV grade confirming to IS : - - -
7098:1988 with upto date amendments of
Laying and fixing of following sizes of one number
263 7.6 PVC insulated and PVC sheathed/XLPE Power cable - - -
of 1.1kv grade on cable tray as required.
264 7.6.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Mtr 850.00 45.00 38,250.00 - -
Supplying and making end termination with brass
compression gland and aluminium lugs for
265 9.1 following size of PVC insulated and PVC sheathed / - - -
XLPE aluminium conductor cable of 1.1 KV grade as
TOTAL CARRIED TO SUMMARY 55,990.00 - 3,26,430.00
C. HOT DEEP GI CABLE TRAYS & GI RACEWAYS
Supplying and installing following size of perforated
Hot Dipped Galvanised Iron cable tray
(galvanisation thickness not less than 50 microns)
268 4.6 with perforation not more than 17.5%, in - - -
convenient sections, joined with connectors,
suspended from the ceiling with G.I. suspenders
269 4.6.2 including
150 mm widthG.I. X 50 mm depth X 1.6 mm thickness Metre 360.00 716.00 2,57,760.00 - -
270 4.6.4 300 mm width X 50 mm depth X 1.6 mm thickness Metre 225.00 963.00 2,16,675.00 - -
271 4.6.6 450 mm width X 50 mm depth X 2.0 mm thickness Metre 135.00 1,325.00 1,78,875.00 - -
272 4.6.11 600 mm width X 50 mm depth X 2.0 mm thickness Metre 90.00 1,909.00 1,71,810.00 - -
TOTAL CARRIED TO SUMMARY 8,25,120.00 - -
Earthing with G.I. earth plate 600 mm X 600 mm X 6
mm thick including accessories, and providing
273 5.4 masonry enclosure with cover plate having locking Each 24.00 7,472.00 1,79,328.00 - -
arrangement and watering pipe of 2.7 metre long
etc. with charcoal/
coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm
X 3 mm thick including accessories, and providing
274 5.6 masonry enclosure with cover plate having locking Nos 20.00 13,838.00 2,76,760.00 - -
arrangement and watering pipe of 2.7 metre long
etc. with charcoal/
coke and salt as required.
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing 25 mm X 5 mm copper strip on
275 5.14 surface or in recess for Meter 205.00 1,162.00 2,38,210.00 - -
connections etc. as required.
Providing & fixing of 25mm x 5mm GI strip on
276 5.15 surface or recess for earth Meter 425.00 244.00 1,03,700.00 - -
connection as required.
Providing and fixing 6 SWG dia G.I. wire on surface
277 5.16 or in recess for loop Meter 150.00 70.00 10,500.00 - -
earthing as required.
TOTAL CARRIED TO SUMMARY 8,08,498.00 - -
E. INTERNAL WIRING:
Wiring for light point/ fan point/ exhaust fan point/
call bell point with 1.5 sq.mm FR PVC insulated
copper conductor single core cable in surface /
278 1.1 recessed medium class PVC conduit, with modular
switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm. FR PVC insulated copper
279 1.10.3 conductor
Group C single core cable etc as required. Point 1,200.00 1,467.00 17,60,400.00 - -
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point (without
independent switch etc.) with 1.5 sq. mm FRLS PVC
280 1.55 insulated copper conductor single core cable in - - -
surface/ recessed steel conduit, and earthing the
point with 1.5 sq. mm FRLS PVC insulated copper
281 1.55.3 conductor
Group C single core cable etc. as required. Point 929.00 1,094.00 10,16,326.00 - -
Wiring for light/ power plug with 2X4 sq. mm FRLS
PVC insulated copper conductor single core cable in
282 1.5 surface/ recessed steel conduit alongwith 1 No. 4 meter 400.00 433.00 1,73,200.00 - -
sq. mm FRLS PVC insulated copper conductor single
core cable for loop
earthing as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS
PVC insulated copper conductor single core cable in
283 1.12 surface/ recessed medium class PVC conduit meter 2,500.00 334.00 8,35,000.00 - -
alongwith 1 No. 4 sq. mm FRLS PVC insulated
copper conductor single core
cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth
284 1.7 wire with the following sizes of FRLS PVC insulated - - -
copper conductor, single core cable in surface/
recessed steel conduit as required.
Wiring for circuit/ submain wiring alongwith earth
288 1.14 wire with the following sizes of FRLS PVC insulated - - -
copper conductor, single core cable in surface/
recessed PVC conduit as required.
Supplying and fixing suitable size GI box with
modular plate and cover in front on surface or in
291 1.31 recess, including providing and fixing 3 pin 5/6 A Each 354.00 477.00 1,68,858.00 - -
modular socket outlet and 5/6 A modular switch,
connections etc. as
Supplying and fixing suitable size GI box with
modular plate and cover in front on surface or in
292 1.56 recess, including providng and fixing 2 Nos. 3 pin Each 155.00 676.00 1,04,780.00 - -
5/6 A modular socket outlet and 2 Nos. 5/ 6 A
modular switch, connections etc. as required. (For
light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with
modular plate and cover in front on surface or in
293 1.32 recess, including providing and fixing 6 pin 5/6 A & Each 410.00 586.00 2,40,260.00 - -
15/16 A modular socket outlet and 15/16 A
modular switch, connections etc.
Supplying and fixing two module stepped type
294 1.25 electronic fan regulator on the existing modular Each 316.00 369.00 1,16,604.00 - -
plate switch box including connections but
Supplying and fixing modular blanking plate on the
295 1.26 existing modular plate & Each 50.00 40.00 2,000.00 - -
switch box excluding modular plate as required.
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Providing and fixing circular/hexagonal Fan box cast
iron /metal sheet Box for ceiling fan clamp of
internal dia 140mm , 73 mm height,Top id of
1.5mm thick MS sheet with its Top surface hacked
of proper bonding top lid shall be screwed into cast
iron /metal sheet Box by mean of 3.3mm dia round
headed screw one lock at the corners.clamp shall
be made of 12mm dia ms Bar band toshape as per
Supplyingdrawing.
and fixing 20 A, 240 V, SPN Industrial
type socket outlet, with 2 pole and earth, metal
enclosed plug top alongwith 20 A "C" curve, SP,
297 2.18 MCB, in sheet steel enclosure, on surface or in Each 44.00 1,621.00 71,324.00 - -
recess, with chained metal cover for the socket
outlet and complete with connections, testing and
TOTAL CARRIEDetc.
TO as required.
F. LIGHTING FIXTURE AND FANS
DSR E&M - LED Down lighter (SMD Type) (System lumen
2025 Vol efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning
of LED Recessed / surface Down lighter (Round
/square/Rectangular) SMD type of following body
material with PMMA and prismatic diffuser and
construction as per IS
: 10322 with driver as per the requirement with
Driver efficiency >85%, Operating voltage AC 140-
270 Volt, freq 50/60 hz, Operating temp range - 15
deg to 40 deg centigrade, internal surge
protection of 2.5 KV with Short & Open circuit
protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,
UGR (Unified Glare Rating) < 19, Flicker free, (flicker
should be below 5 %), life time (LED,Driver &
electrical circuitry), life time of minimum 50000
Burning Hours with , 70% of initial Lumen
maintained till life ends as per LM80
299 extrapolation IES TM-21-11 report, CCT 3000°K / - - -
Bin) , SDCM(Standard Deviation Color Matching)
<3, Maximum power consumption should not
more than the specified rating and Fixture shall be
of relevant BIS standard and trade mark certificate (
T.C.). Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. OEM
must have its own in house NABL lab setup for
all testing facilities for LED fixtures. complete in
all respect i/c connections with 1.5 sq mm
FRLS, PVC insulated copper conductor single core
cable and earthing etc. as required with Minimum 5
year OEM warranty. System lumen efficacy >135
output . LM79 & LM80 Test report from NABL lab
for all testing required for LED fixtures as per BIS
shall be submitted. Shape size and CCT shall be as
Powder coated die cast / Extruded aluminum
Body including trim.
DSR 12 -15 watt
Supply of 9W LED (mirror light) 2ft Batten with a
nominal system lumen output of 1150 lumens and
a minimum system efficacy of 115 lm/W. The
luminaire shall have a rated system lifetime of
25,000 burning hours at L70. The luminaire should
have a color temperature of 6500K and CRI>80. The
luminaire shall meet IP20 rating with THD < 20%
and PF > 0.9. The luminaire housing should made of
CRCA with a PC glossy diffuser. The total power
consumption should not exceed 10W (including
LED Batten light (System lumen efficacy >135
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Supplying, installation, Testing & Commissioning of
LED surface mounted Batten light of following body
material and construction as per IS : 10322 with
driver (Replaceable) as per the requirement with
Driver efficiency
>85% ,Operating voltage AC 140-270 Volt, freq
50/60 hz, Operating temp range 15 deg to 40 deg
centigrade, internal surge protection of 2.5 KV with
Short & Open circuit protection ,THD < 10% , P.
F.≥0.95, IP20, CRI >80 , Flicker free (flicker should
be below 5 %), life time (LED,Driver & electrical
circuitry), of minimum 50000 Burning Hours
with , 70% of initial Lumen maintained till life
/6000°K/ 6500°K (As per ANSI Bin), SDCM
305 (Standard Deviation Color Matching) <3, Maximum - - -
power consumption should not more than the
specified rating and Fixture shall be of relevant BIS
standard and trade mark certificate ( T.C.).
Manufactures Word Mark/ Name Engraved/
Embossing/ Screen printing on housing. OEM must
have its own in house NABL lab setup for all
testing facilities for LED fixtures. complete in all
respect i/c connections with 1.5 sq mm FRLS,
PVC insulated copper conductor single core cable
and earthing etc. as required with Minimum 5 year
OEM warranty. System lumen efficacy >135
lm/Watt output . LM79 & LM80 Test report from
NABL lab for all testing required for LED
fixtures as per BIS shall be submitted. Shape size
and CCT shall be as approved by Engineerin-Charge
306 CRCA Sheet Body (Thickness ≥ 0.50 mm) - - -
DSR 24 -26 watt
Supply, Installation, Testing and Commissioning of
1200 mm sweep, BEE 5 star rated, ceiling fan with
Brush Less Direct Current (BLDC) Motor, class of
insulation: B, 3 nos. blades, 30 cm long down rod, 2
nos. canopies, shackle kit, safety rope, copper
winding, Power Factor not less than 0.9, Service
308 DSR 19.1 Value (CM/M/W) minimum 6.00, Air delivery No. 316.00 2,730.00 8,62,680.00 - -
minimum 210 Curn/Min , 350 RPM (tolerance as
per IS : 374-2019), THD less than 10%, remote or
electronic regulator unit for speed control and all
remaining accessories including safety pin, nut
bolts, washers, temperature rise=75 degree C
(max.), insulation resistance more than 2 mega
ohm, suitable for 230 V, 50 Hz, single phase AC
Supplying and Fixing of Exhaust Fan Heavy duty
TOTAL CARRIED TO SUMMARY 8,62,680.00 16,14,471.00 3,73,802.00
H LIGHTNING ARRESTER
Providing and fixing of lightning conductor finial,
310 DSR 6.2 made of 25 mm dia 300mm long, G.I. tube, having Each 10.00 518.00 5,180.00 - -
single prong at top, with 85mm dia 6mm thick G.I.
base plate i ncluding holes etc. complete as
Providing and fixing G.I. tape 20 mm X 3 mm thick
311 DSR 6.7 on parapet or surface of wall for lightning metre 90.00 126.00 11,340.00 - -
conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick
312 DSR 6.8 on parapet or surface of wall for lightning metre 60.00 197.00 11,820.00 - -
conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X
313 DSR 6.12 3 mm thick G.I. strip, 125 mm long, with 4 nos. of Each 8.00 121.00 968.00 - -
G.I. bolts, nuts, chuck nuts and spring washers etc.
complete as required.
Earthing with G.I earth Pipe 4.5 metre long, 40mm
dia including accessories and providing masonry
314 DSR 5.2 enclosure with cover Plate having locking nos 8.00 6,855.00 54,840.00 - -
arrangement and watering pipe etc with charcoal
/coke and salt as required.
Jointing copper /G.I. tape (with another copper/ GI
315 DSR 6.4 tape, base of the finial or any other metallie object) Each 8.00 113.00 904.00 - -
by riveting /nut bolting/sweating and soldering
etc as required.
Providing and laying G.I. tape 32 mm X 6 mm from
316 DSR 6.14 earth electrode directly meter 140.00 195.00 27,300.00 - -
in ground as required.
TOTAL CARRIED TO SUMMARY 1,12,352.00 - -
Signature of Contractor Signature
Digitally signedofby
Items Ref. DESCRIPTION Rate (INR) Amount (INR)
Sl No. (DSR- Unit Quantity DSR-
DSR-2025 MR DSR-2023/2022 DSR-2025 NDSR Amount
Total - Internal Electrical 91,09,903.00 16,14,471.00 7,90,549.00
Signature of Contractor Signature
Digitally signedofby
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
NIT Bhimavaram.pdf
Tender Document
SCC.pdf
Tender Document
GCC Contracting for Construction works 2026.pdf
Tender Document
Integrity Pact.pdf
Tender Document
BOQ.pdf
Tender Document
List of approved Make.pdf
Tender Document
Tender Drawings.pdf
Tender Document
Tender Drawings Elevation dwg.pdf
Tender Document
Tender Drawings Electrical SLD dwg.pdf
Tender Document
Physical Milestone Annexure IA.pdf
Tender Document
Technical Specification.pdf
Tender Document
Technical_Circulars.pdf
Tender Document
corrigendum-5266-Corrigendum 07.pdf
pdf • 0.06 MB
corrigendum-5238-Corrigendum 06.pdf
pdf • 0.06 MB
corrigendum-5208-Corrigendum 05.pdf
pdf • 0.06 MB
corrigendum-5186-Corrigendum 04.pdf
pdf • 0.06 MB
corrigendum-5158-Corrigendum 03.pdf
pdf • 0.06 MB
corrigendum-5127-Corrigendum 02.pdf
pdf • 0.06 MB
corrigendum-5099-Corrigendum 01.pdf
pdf • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .