Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC OFFICE 408 SHLOK INFINITY OPP VISHWAKARMA MANDIR CHANDLODIA AHMEDABAD GUJARAT 382481 | AHMADABAD | GUJARAT | 382481 | ₹4.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹5.9 L+₹1.9 L (48.1%)Rejected-AOC | ₹5.9 L+₹1.9 L (48.1%) | L2 | Rejected-AOC L2 |
| 3 | L3₹6.2 L+₹2.2 L (55.4%)Rejected-AOC | ₹6.2 L+₹2.2 L (55.4%) | L3 | Rejected-AOC L3 |
| 4 | L4₹6.4 L+₹2.4 L (60.8%)Rejected-AOC | ₹6.4 L+₹2.4 L (60.8%) | L4 | Rejected-AOC L4 |
| 5 | Rejected-Technical S R K INDUSTRIAL ESTATE B H MONI HOTEL ISANPUR NAROL HIGHWAY AHMEDABAD 382443 | AHMADABAD | GUJARAT | 382443 | - | - | Rejected-Technical Not Qualified |
| Sl No | Description | Qty | Unit | PRATHAM CONSTRUCTION CO L3 | Shivdip Builders PVT.LTD. L4 | RUDRAVEER ELECTROMECH PROJECTS PRIVATE LIMITED L1 | Laxmi Engineering Works L2 |
|---|---|---|---|---|---|---|---|
| 100.00Providing, fabricating and erecting MS ladder with service platforms in the New Campus, IIM Ahmedabad: a) Providing, fabricating and fixing the mild steel ladder with two numbers of service platforms in plumbing shaft for maintenance purpose as same as existing done in Dorm-19 & Dorm-21. b) Ladder verticals to be prepared by using MS pipe of diameter 42.40 mm (outer diameter) 3.2mm thick and steps of diameter 33.70mm and 3.2mm thick. Steps width to be kept 250mm and spacing should be 300mm c/c. c) Total floors of building is ground + three floors (height is approximate-12 mts) d) First platform size- 820 x 500 mm will be near washroom ventilator made up of box section 40 x 40 x 3.2mm with flats section in between of size 50mm x 5mm and supported on MS angle section 50 x 50 x 5mm. e) Second platform size- 230 x 800 mm will be connected to first platform fixed in nature. f) Second platform is made up of box section 40 x 40 x 3.2mm with flats section in between of size 50mm x 5mm and supported on MS angle section 50 x 50 x 5mm. g) Sizes mentioned above are tentative based on existing sample done. They may change during actual work with prior approval. h) Fastner upto 12mm diameter and 150mm length to be used. i) Corners of box sections and MS pipe to be closed by blanks. j) Welding for joints to be done for entire length. k) All the MS sections after sanding to be applied with one coat of yellow zinc oxide primer and then two coats of antirust enamel paint. l) No extra will be paid for wastages. m) It includes repairing of CPVC/PVC water supply lines if damaged during ladder erection work. No extra cost will be paid for such repairing work. Notes-Sample of the material to be get approved form IIM representative before going for mass purchase & fabrication. Refer photo in NIT (last page). | |||||||
| 101.00 | Total Weight of Mild steel sections | 2,840 | Kgs | 180 ₹5,11,200 | 157 ₹4,45,880 | 125 ₹3,55,000 Lowest | 164.75 ₹4,67,890 |
| 102.00 | Total number of fastners | 452 | Nos | 108 ₹48,816 | 350 ₹1,58,200 | 50 ₹22,600 Lowest | 174.5 ₹78,874 |
| 200.00 | Providing and fixing scaffolding system (cup lock type)
a) Providing and fixing scaffolding system (cup lock type) in the plumbing shaft up to four story height made with 40mm dia. M.S. tube 1.5 m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after.
b) The scaffolding system shall be stiffened with bracings, runners etc. wherever required for inspection of work at required locations with essential safety features (Fall arrester, safety belt, helmet, safety shoes, safety jacket) for the workmen etc. complete as per directions and approval of Engineer In-charge.
c) The elevation area of the scaffolding shall be measured for payment purpose. The payment will be made once per plumbing shaft irrespective of duration of scaffolding at any location.
d) Safety board designating "Work is in Progress" around scaffolding system to be installed. Safety barricades & tapes to be placed aroud the area of work. | 162 | Sqmt | 360 ₹58,320 | 220 ₹35,640 | 125 ₹20,250 Lowest | 262.18 ₹42,473.16 |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
10 Mar 2026, 3:00 pmClosed
CAO
IIM Ahmedabad, Sargam Marg, Vastrapur, Ahmedabad
Tender for MS ladder with service platform in plumbing shaft of Student Dormitory in the New Campus, IIM Ahmedabad
2026_IIMA_898877_1
IMA/Contracts/TW-61/2025-26
Open Tender
Miscellaneous Works
Item Rate
IIM Ahmedabad
As per NIT
7 documents required · 7 mandatory
₹0
₹8,000
Yes
IIM Ahmedabad
9 Jun 2026
17 Feb 2026
11 Mar 2026
17 Feb 2026
10 Mar 2026
24 Feb 2026
17 Feb 2026 - 20 Feb 2026
20 Feb 2026
Providing, fabricating and erecting MS ladder with service platforms in the New Campus, IIM Ahmedabad: a) Providing, fabricating and fixing the mild steel ladder with two numbers of service platforms in plumbing shaft for maintenance purpose as same as existing done in Dorm-19 & Dorm-21. b) Ladder verticals to be prepared by using MS pipe of diameter 42.40 mm (outer diameter) 3.2mm thick and steps of diameter 33.70mm and 3.2mm thick. Steps width to be kept 250mm and spacing should be 300mm c/c. c) Total floors of building is ground + three floors (height is approximate-12 mts) d) First platform size- 820 x 500 mm will be near washroom ventilator made up of box section 40 x 40 x 3.2mm with flats section in between of size 50mm x 5mm and supported on MS angle section 50 x 50 x 5mm. e) Second platform size- 230 x 800 mm will be connected to first platform fixed in nature. f) Second platform is made up of box section 40 x 40 x 3.2mm with flats section in between of size 50mm x 5mm and supported on MS angle section 50 x 50 x 5mm. g) Sizes mentioned above are tentative based on existing sample done. They may change during actual work with prior approval. h) Fastner upto 12mm diameter and 150mm length to be used. i) Corners of box sections and MS pipe to be closed by blanks. j) Welding for joints to be done for entire length. k) All the MS sections after sanding to be applied with one coat of yellow zinc oxide primer and then two coats of antirust enamel paint. l) No extra will be paid for wastages. m) It includes repairing of CPVC/PVC water supply lines if damaged during ladder erection work. No extra cost will be paid for such repairing work. Notes-Sample of the material to be get approved form IIM representative before going for mass purchase & fabrication. Refer photo in NIT (last page).
Total Weight of Mild steel sections
Total number of fastners
Providing and fixing scaffolding system (cup lock type) a) Providing and fixing scaffolding system (cup lock type) in the plumbing shaft up to four story height made with 40mm dia. M.S. tube 1.5 m centre to centre horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. b) The scaffolding system shall be stiffened with bracings, runners etc. wherever required for inspection of work at required locations with essential safety features (Fall arrester, safety belt, helmet, safety shoes, safety jacket) for the workmen etc. complete as per directions and approval of Engineer In-charge. c) The elevation area of the scaffolding shall be measured for payment purpose. The payment will be made once per plumbing shaft irrespective of duration of scaffolding at any location. d) Safety board designating "Work is in Progress" around scaffolding system to be installed. Safety barricades & tapes to be placed aroud the area of work.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
AnnexureAtoJ.pdf
Tender Documents • 1.50 MB
BOQ_944823.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .