Executive Engineer
Jal Shakti Division Paonta Sahib
Supply and Errection of Centrifugal Pumping Machinery with allied accessories for LWSS Danda Anj and Moni and LWSS Danda Kalatha
2021_HPIPH_47788_1
PNT-SMR-02-720 No. 2235-2304 Dated 21/05/2021
Open Tender
Civil Works
Item Rate
180 days
Paonta Sahib
Please refer to tender documents
8 documents required · 8 mandatory
₹400
EE JS Division Paonta Sahib
₹34,100
Yes
23 Jun 2021
26 May 2021
31 May 2021
26 May 2021
31 May 2021
26 May 2021
26 May 2021 - 31 May 2021
Amount
Pumping Machinery (DANDA ANJ & MONI )
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing, radial split Single /Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water , having characteristics as mentioned below in item No.1(A) with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below including the cost of all accessories in all leads and lifts & carriage of material at the site as per direction of Engineer-in-charge. 50X2=100 HP Note:-Tenders to be called for Per HP not for Per set rate.
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 502.00 mtrs
Capacity in LPS 3.41 LPS
Dia of R/Main (in mm) 65 mm dia
Dia of Column pipe (in mm) 65 mm dia
Length of Rising main 1210 mtr.
Providing & fixing of Auto Control Panel with Push Button 2 Nos Star delta Starter for Centrifugal Pumps of L&T and reputed make fabircated with M.S. Sheet and angle stand duly painted and complete within internal wiring , comparising of main switch of suitable Amp T.P. Volt meter, Copper busbar , Ammeter, Hours run meter, Phase Indicating lamps with GMS based, Remote start /stop operation call/ SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day , Inbuilt protection against overload/ undervoltage , Dry run, single phase preventor, Inbuilt GPS tracker, phase reversal configurable volt/ current limits with a facility to access the system through minimum 10 Nos, autheniticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts, installation and testing at site with entire satisfaction of Engineer-in-charge. ( All meters to be installed shall be DIGITAL)
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. The Class of Valve shall be ASA -600
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/BHEL/Leader/KSB make of suitable size cast steel double flanged swing check type reflex valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. No. 1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. The Class of Valve shall be ASA -600
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No.1(c) for withstanding nominal seat pressure as per item 1(a) + surge pressure. The size of reflex valve shall be equal to size for Rising main of the same shall be provided withstanding bye pass arrangements . The Class of Valve shall be ASA-600 & shall be of 65mm diameter
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast iron double sluice valve ( In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr. / sec and confirming to BIS standards with upto date ammendments. The class of valve shall be P.N. 1.6
P/L at site suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from switch to starter & starter to moter ( one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes, thimbles ,nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection at site of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.
Providing and fixing GMS double flanged suction delivery pipe & common header confirming to " Heavy Grade" of BIS 1239- (Part-1)- 1990 or latest with upto date ammendments considering site requirements. NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 4 (a) or total dynamic pressure + surge pressure whichever is higher. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump. Thickness of G.I. Pipe shall be 4.50 mm jointed with Flanged joint of FT-34. The suction pipe shall be of GMS(MG) Pipe jointed with FT-5 NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Pumping Machinery ( Danda Kalatha)
Supply, erection, testing & commissioning of horizontal spindle,horizontal split casing, radial split Single /Multistages centrifugal pumps of standarad make such as KSB/ Mather & Platt/ Jyoti /Kirloskar/ Beaconweir /BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handle clear water , having characteristics as mentioned below in item No.1(A) with impelleres,casing ring, priming funnels & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel /Mild steel to BHEL /Kirlokar/ NGEF/ Crompton / Siemen/Jyoti /GEC make slip ring /squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below including the cost of all accessories in all leads and lifts & carriage of material at the site as per direction of Engineer-in-charge. 10X2=20 HP
Total Head in mtrs (i/c depth of Column Pipe in case of t/well) : 339.50 mtr
Capacity (in LPS) : 1.17 LPS
Dia of R/Main (in mm) : 50 mm
Dia of Column pipe (in mm) : 50 mm
Length of Rising main : 850 mtr.
Providing & fixing of Auto Control Panel with Push Button 2 Nos Star delta Starter for Centrifugal Pumps of L&T and reputed make fabircated with M.S. Sheet and angle stand duly painted and complete within internal wiring , comparising of main switch of suitable Amp T.P. Volt meter, Copper busbar , Ammeter, Hours run meter, Phase Indicating lamps with GMS based, Remote start /stop operation call/ SMS for feedback regarding running of pumps & breakdown message, timer scheduling for fixed hours in a day , Inbuilt protection against overload/ undervoltage , Dry run, single phase preventor, Inbuilt GPS tracker, phase reversal configurable volt/ current limits with a facility to access the system through minimum 10 Nos, autheniticated mobile Nos. complete in all respect, including entire carriage of materials upto all leads and lifts, installation and testing at site with entire satisfaction of Engineer-in-charge. ( All meters to be installed shall be DIGITAL)
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of cast steel double flanged sluice valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. The Class of Valve shall be ASA -300
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/BHEL/Leader/KSB make of suitable size cast steel double flanged swing check type reflex valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. No. 1(a) + surge pressure & conforming to API-standards with up to date ammendments for delivery line of pump. The Class of Valve shall be ASA -600
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of suitable size Cast Steel double flanged swing check type reflux valve confirming to API standard with up to date ammendments for R/main as mentioned in item No.1(c) for withstanding nominal seat pressure as per item 1(a) + surge pressure. The size of reflex valve shall be equal to size for Rising main of the same shall be provided withstanding bye pass arrangements . The Class of Valve shall be ASA-300 & shall be of 50mm diameter
Supply & fixing at site of work of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/KSB make of Cast iron double sluice valve ( In case Suction is +ve) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 3.00 mtr. / sec and confirming to BIS standards with upto date ammendments. The class of valve shall be P.N. 1.6
P/L at site suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from meter of HPSEB to circuite breaker & from circuite breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ICC/EICO/National /IEC make from switch to starter & starter to moter ( one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe, solder, nuts & bolts, cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
P/L at site double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes, thimbles ,nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments.
Supply & errection at site of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer).
Supply and fixing at site of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc.conforming to BIS 3624-1987 or latest with up to date ammendments.
Providing and fixing GMS double flanged suction delivery pipe & common header confirming to " Heavy Grade" of BIS 1239- (Part-1)- 1990 or latest with upto date ammendments considering site requirements. NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 4 (a) or total dynamic pressure + surge pressure whichever is higher. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump. Thickness of G.I. Pipe shall be 4.50 mm jointed with Flanged joint of FT-28. The suction pipe shall be of GMS(MG) Pipe jointed with FT-5 NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
RISING MAIN
Excavation in drains and channels for pipes upto all depth and in all classification of earth work such as pick,Jumper work , saturated soil chiselling soft/hard rock where blasting prohabitated in all lifts including blasting or pumping out water and ramming and dressing of sides, levelling of bends to correct grade i/c shuttering/ strutting planking, timnering & dewatering whereven required stacking the useable & unserviceable material/ soil separately & after laying jointing & testing of pipes returning the useable soil in trenches in 15cm layers i/c consolidating of each deposited layer by ramming , watering & then disposing of all surplus excavated soil/ unuseable materials as directed with in all leads lifts i/c restoration of unmettalled surface to its original condition and i/c cost of diversion for traffic light singnal, fixing caution boards crossing over trenches for access to houses fancing etc. complete in all respect within all leads lifts and as per direction of Engineer-in-charge.
Providing , Laying , jointing & commissioning at site in trenches bevelled ended MSERW Pipe Grade "A" API Specification of 5L Grade B or confirming to IS- 3183-209 having wall thickness & per Rmt. weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding , including the cost of jointing with butt welding confirming to IS: 816-1969 or latest with upto date ammendments ( leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site ,tail pieces, tees and other specials manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions and cutting of pipes wherever required as per site requirement i/c carriage in all leads lifts and as directed by Engineer-in-charge. The Pipe shall have's zinc coating inside & outside confirming IS-4736-1986 or latest with upto date ammendments & shall be engraved with Grade , B -grades L-245 130 3183-2012& its equivalent. The laying shall be confirm to BIS 5822-1970 or latest with upto date ammendments to the entire satisfaction of Engineer-in-Charge.(Earth work shall be measured & paid for seperately)
KALATHA Sr. No. RD from To Nominal Dia MSERW Thickness Wt.Kg./m) Length (in mtr.) 1 0 to 360 50mm (G.I. Heavy) 4.40MM 6.07 360.00 mtr
Laying , jointing & commissioning at site in trenches following plain ended GMS Pipes of following dia of heavy grade as under confirming to BIS 1239 (Part-1)- 1990 or latest with upto date ammendments, capable of withstanding required test pressure as prescribed in BIS code in randum lengths of 5.5 to 6.5 mtr. The pipes ends shall be bevelled suitable for butt weld, including cost of jointing with butt welding confirming to IS: 816-1969 or latest as applicable ( leak proof) in three layers at site of work with welding rods of standard make & all allied accdessories whatever required for welding at site tails pieces, tees , bends manufactured from parent pipes etc. and cutting of pipes wherever required as per site requirement including carriage of material in all leads lifts and as directed by Engineer-in-charge.(Earth work shall be measured & paid for seperately)
DANDA ANJ AND MONI Sr. No. RD from To Nominal Dia GMS Thickness Length (in mtr.) 1 400 to 1210 65mm (G.I. Heavy) 810.00 mtr
DANDA ANJ AND MONI Sr. No. RD from To Nominal Dia GMS Thickness Length (in mtr.) 1 360 to 850 50mm (G.I. Heavy) 490.00 mtr
Providing , welding and fixing M.S. Plate flanges of various dia (nominal bore) of following table to conforming to IS 6392-1971 or latest with upto date ammendments to MSERW/ GMS Pipes after every 90 metres or as per site requirement including cutting of pipes wherever required, welding in three layers (leak proof ) confirming to specifications as prescribed relevant I.S. Code 816-1969 or latest as applicable with upto date ammendments with nuts, bolts & washers & specials etc. confirming to IS 1963 or latest with upto date ammenments including packing sheet i,e, asbestos fibre sheet minimum 3mm thick and painting with anticorosive paints complete in all respect in all leads, lifts and carriage of material at site and as direted by the Engineer incharge.
DANDA ANJ AND MONI Sr. No. RD from To Nominal Dia GMS Length (in mtr.) F.T. 1 410 to 900 65mm 490.00 mtr FT-28
2 900 to 1080 65mm 180.00 mtr FT-17
3 1080 to 1210 65mm 130.00 mtr FT-5
KALATHA Sr. No. RD from To Nominal Dia GMS Length (in mtr.) F.T. 1 0 To 540 50mm 540 mtr FT-28
2 540 To 720 50mm 180 mtr FT-17
3 720 To 850 50mm 130 mtr FT-5
Vats Associates
M/S Sharma Enterpirses
HYDRAULIC ENGINEERING COMPANY
Himalaya Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .