Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.2 L+₹970.05 (0.03%)Rejected-AOC C O LT MAAHANTA NARZARY W NO 5 TENGAPARA P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Failed |
Tender Value
₹33.2 L
EMD Value
₹66,311
Closing Date
1 Nov 2023, 2:30 pmClosed
Sri Padmadanda Choudhury
O/o the Addl. Chief Engineer-cum-Director, PWD, BTC, Kokrajhar.
Repair and Renovation of rooms in the existing building to be used as Guest House at Directorate of Women and Child Development, Dimalgaon, BTC with electrification and water supply system under SOPD Fund for the year 2023-24. TN No.28_02
2023_BTC_32918_1
No.27/KOJ/NIT/Pt-II/2023-24/29
Open Tender
Civil Works - Building
Item Rate
180 days
Kokrajhar
Refer to tender documents
4 documents required · 4 mandatory
₹1,000
₹66,311
Yes
20 Nov 2023
11 Oct 2023
2 Nov 2023
11 Oct 2023
1 Nov 2023
11 Oct 2023
11 Oct 2023 - 1 Nov 2023
Amount
14.1 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.1.2 With cement mortar 1:4 (1cement: 4 coarse sand)
14.5 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
14.41 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete.
14.82 Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below
15.7 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar
15.23 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. 15.23.1 For thickness of tiles 10 mm to 25 mm
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
13.5 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand)
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.2 Kiln seasoned and chemically treated hollock wood 9.5.2.2 30 mm thick shutters
9.74 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 9.74.3 150x10 mm
11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1 Size of Tile 600 x 600 mm
11.47 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 11.47.2 Size of Tile 600x600 mm
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.
10.3 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
13.88 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.37 White washing with lime to give an even shade : 13.37.1 New work (three or more coats)
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
SANITARY & PLUMBING WORKS 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board 17.10.1.1 510x1040 mm bowl depth 250 mm
17.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.3 Oval shape 450x350 mm (outer dimensions)
17.35 Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal dia Pipes
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.1 15 mm nominal dia Pipes
18.9.2 20 mm nominal dia Pipes
18.9.6 50 mm nominal dia Pipes
18.9.9 100 mm nominal dia Pipes
18.15 Providing and fixing brass bib cock of approved quality : 18.15.1 15 mm nominal bore
18.16 Providing and fixing brass stop cock of approved quality : 18.16.1 15 mm nominal bore
18.20 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.20.1 15 mm nominal bore
18.20.2 20 mm nominal bore
18.90A Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° 18.90A.1 For 15 mm outer dia pipe
18.90A.2 For 22 mm outer dia pipe
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
DEEP TUBE WELL 23.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.2 Rocky strata including Boulders 23.1.2.1 300 mm dia
23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 23.3.1 100 mm nominal size dia
23.8 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 23.15.2 150 mm dia
18.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 18.46.5 40 mm nominal bore
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.5 40 mm nominal dia Pipes
18.19 Providing and fixing gun metal non- return valve of approved quality (screwed end) : 18.19.3 40 mm nominal bore 18.19.3.2 Vertical
Supplying, fitting and fixing of 2 H.P. Submerssible pump set (Water filled motor) as required and directed by the department. (Crompton/ Kirloskar/ Usha or equivalent)
ELECTRIFICATION A. Ground Floor 1.10. Wiring for light point/ fan point/ exhaust fan point/ call bell point 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable. 1.10.1 Group A
1.10.2 Group B
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the flowing sizes of FRLS PVC insulated copper conductor, single core in surface/ recessed medium class PVC conduit as required. conduit as required. 1.14.2 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
1.14.3 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
1.14.4 2 x 6 sq.mm + 1 x 6 sq.mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 2.24.1 5/6A switch
2.24.3 15/16A switch
1.24.4 3pin 5/6A socket outlet
1.24.5 6pin 15/16 A socket outlet
1.24.8 Bell push
1.25 Supplying and fixing two module stepped type electronic tan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33 Supplying and fixing 3pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
2.3 Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. required. (But without MCB/ RCCB/ Isolator) 2.3.3 12way, Double door
9.2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet, MCB distribution board, 415V on surface/ recess, complete with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. is required. (But without MCB/RCCB/lsolator) 2.4.1 4 way (4+12) Double door
2.10 Supplying and fixing 5 A to 32 A rating. 240/415 V. 10 kA. "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.2 Double pole
2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.2.63 A
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc, as required.
MR-1 Supplying with including fitting fixing of Ceiling fan etc. as directed by the Deptt.
MR-2 Supplying including fitting fixing of 18 W Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens fluorescent lamps vsith elegantly designed end caps etc. as required and directed by the
MR-3 Supplying with including fitting fixing of ADORE LED PLUS 9 W / 10 W. etc. as required & directed by the Deptt.
MR-4 Supplying with including fitting fixing of Exhaust Fan etc. as directed by the Deptt.
MR-5 Supplying with fitting fixing of 15 W LED Surface-mounting low-height round LED down lighter required and directed by the deptt.(Orient /Bajaj/ Hevells Make).
B. First Floor 1.10. Wiring for light point/ fan point/ exhaust fan point/ call bell point 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable. 1.10.1 Group A
1.10.2 Group B
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the flowing sizes of FRLS PVC insulated copper conductor, single core in surface/ recessed medium class PVC conduit as required. conduit as required. 1.14.2 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
1.14.3 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
1.14.4 2 x 6 sq.mm + 1 x 6 sq.mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 2.24.1 5/6A switch
2.24.3 15/16A switch
1.24.4 3pin 5/6A socket outlet
1.24.5 6pin 15/16 A socket outlet
1.24.8 Bell push
1.25 Supplying and fixing two module stepped type electronic tan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33 Supplying and fixing 3pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
2.3 Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. required. (But without MCB/ RCCB/ Isolator) 2.3.3 12way, Double door
9.2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet, MCB distribution board, 415V on surface/ recess, complete with tinned copper bus bar neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. is required. (But without MCB/RCCB/lsolator) 2.4.1 4 way (4+12) Double door
2.10 Supplying and fixing 5 A to 32 A rating. 240/415 V. 10 kA. "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
2.10.2 Double pole
2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.2.63 A
MR-1 Supplying with including fitting fixing of Ceiling fan etc. as directed by the Deptt.
MR-2 Supplying including fitting fixing of 18 W Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens fluorescent lamps vsith elegantly designed end caps etc. as required and directed by the Deptt.
MR-3 Supplying with including fitting fixing of ADORE LED PLUS 9 W / 10 W. etc. as required & directed by the Deptt.
MR-4 Supplying with including fitting fixing of Exhaust Fan etc. as directed by the Deptt.
MR-5 Supplying with fitting fixing of 15 W LED Surface-mounting low-height round LED down lighter required and directed by the deptt.(Orient /Bajaj/ Hevells Make).
MR-6 Supplying with installation of, testing and commissioning of Hi wall 3 star inverter split type air conditioner of following capacity with cordless remote complete with copper pipe and electrical connection etc. as required and as directed by the Deptt. 1.5 Ton capacity Voltas (Classic) SAC 183V CZJ
MR-7 Supplying with fitting & fixing of 3 KVA voltage stabilizer of following specification complete with necessary electrical connection etc. as required and as directed by the Department (Microtec or equivalent) 150-280 Volt, 3.00 KVA
MR-8 Supplying with fitting & fixing of A.C./ Motor Starter Switch 240V-50Hz complete with necessary electrical connection etc. as required and as directed by the deptt. (Anchor/ Havell/ Bajaj Make.)
MR-9 Design, fabrication & supply of Floor mounted compartmentalized dust and vermin proof power distribution panel board (L.T.-3 ph, 415V, AC 100 Amp) made of M.S. Sheet of not less than 16 swg duly welded & Powder Coated with Grey colour to both in interior & exterior, All wiring for control & metering shall be done by multistranded PVC insulated Finolex make single core copper flexible cable of not less than 1.5 sq.mm. Size and will be properly harnessed and drawn neatly clamped for incoming & out going cables, 4 (Four) separately electrolytic grade aluminium busbar (3 phase & Neutral) of 100 amps will be layed in separate chamber. All the alley connecter shall be connected by flat/ round/ flexible Copper cable etc.
MR-10 Supplying, installation with fitting & fixing of LUMINOUS UPS system including UPS Battery Trolley (LUNINOUS Inverter Sine Wave, Model No. ECO VOLT+1650 and Tall Tubulat Baattery-150 Ah, Model No. PC18042) as required and directed by the deptt.
MR-11 Supplying with fitting fixing of electric storage water Heater (Geyser) of CROMPTOP make including necessary connection etc. as required complete and as directed by the Deptt. (Water heater Geyser 15 Ltr. Capacity)
C. Waiting Shed/ Security Room 1.10. Wiring for light point/ fan point/ exhaust fan point/ call bell point 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable. 1.10.1 Group A
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the flowing sizes of FRLS PVC insulated copper conductor, single core in surface/ recessed medium class PVC conduit as required. conduit as required. 1.14.2 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
1.14.4 2 x 6 sq.mm + 1 x 6 sq.mm earth wire
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. 2.24.1 5/6A switch
1.24.4 3pin 5/6A socket outlet
1.25 Supplying and fixing two module stepped type electronic tan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33 Supplying and fixing 3pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.2.63 A
8.5.2 Earting with G.I. earth pipe 4.5 metre long, 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and salt as required.
9.5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection termination with GI thimble etc. as required.
MR-1 Supplying with including fitting fixing of Ceiling fan etc. as directed by the Deptt.
MR-2 Supplying including fitting fixing of 18 W Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens fluorescent lamps vsith elegantly designed end caps etc. as required and directed by the Deptt.
MR-3 Supplying with including fitting fixing of ADORE LED PLUS 9 W / 10 W. etc. as required & directed by the Deptt.
D. 63 KVA Transformer 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreading in existing cubicles panel board including drilling holes in cubicle panel, making connections etc. as required. 2.2.1 100A, 16KA, TPMCCB
2.22 Providing and fixing H.T. danger notice plate of 250mm x 200mm, made of mild steel, at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with G.I. thimble etc. as required.
5.9 Supplying and laying 25mm x 5mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt& spring washer spaced at 50mm)
7.1 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required 7.1.1 Upto 35 sq.mm
13.1 Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/20mm dia X 1.8 metres long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle (20mm x 600mm), 4.00mm dia G.I. stay wire and 11KV strain insulator etc. in cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required.
13.4 Supplying of channel iron 75mm x 40mm x 6mm (7.14 kg per metre) cross arm fro two 11 KV over head line conductors complete with 50mm x 50mm x 6mm (angle iron bracket welded to the channel iron and complete with 50mm x 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
13.5 Supplying of channel iron 75mm x 40mm x 6mm (7.14kg per metre) V shape cross for two 11 KV over head line conductor complete with 50mm x 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as
13.10 Supplying and erection of 11KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
13.11 Supplying and erection of 11KV disc insulator for 11 KV over head line with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
13.13 Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltages 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
MR-12 supplying, installation, testing and commissioning of the 63KVA 33/0, 433KV aluminium wound outdoor type od filled (BIS Level-I) Transformer complete including all accessories like Earthing terminal, Liftung Lugs, Drain Valve, Oil, filling Hole with Plug, Silicagel Breather, first filling of Oil as per IS 1180 (Part-I):2014 Arcing Horn, Radiator, Air Release Plug, Conservator Tank etc, along with charging approval of the Sub Station from the competent authority as directed and specified by the department. Transformer should be as per CEA guideline as amended up to date. (All require materials for the sub-station will be measured & paid separately) (Power Maker Unit-II)
MR-13 Supplying including erection of 11.00 Mtr. Galvanized Steel Tubular Swaged Pole (410-sp-57) (Stnd. Weight 256Kg) along with fitting fixing, excavation work, foundation of bolts and nuts in R.C.C. work in 1:3:6 proportion of 1.80 Mtr. Depth, Cement plastering and etc. complete with all necessary materials as required and specified by the Department.
MR-14 Supplying with fitting and fixing of 11 KV D.O. Fuse se 150 Amp. As required and specified by the Department.
MR-15 Supplying with fitting and fixing of 11 KV GOAB Switch 150 Amp. As required and specified by the Department.
MR-16 Supplying with fitting and fixing 3-Phase 4W ICS DEMS complaint LT Trivector energy meter (Category-A), 3 x 240V Phase to neutral-5A Class 0.5s for DTR metering
MR-17 Supplying with erection of ACSR “RACCON” Conductor as required and as directed by the Deptt.
MR-18 Design, fabrication & supply of Floor mounted type compartmentalized dust and vermin proof power receiving Panel Board (L.T.-3 ph, 415V, AC, 100 Amp) made of M.S. Sheet of not less than 16 swg duly welded & Powder Coated with Grey colour to both in interior & exterior. The Panel board ill be comprises with the materials like MCCB 100 Amp with Rotary Handle, Busbar etc.
MR-19 supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV Gd. Solid Aluminium conductor up to 10 Sqmm, Balance stranded conductor, XLPE Insulated cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq.mm, balance Aluminium strip. (Galvanised wire for cables up to 2 x10 sq.mm., 3 x 10 sq.mm & balance all galvanised steel strip), extruded PVC type ST2 sheathed, 650/1100V grade as per IS7908 (Part-I) 1988 armoured U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this deptt. 50.00 sq.mm 3½ Core U.G. Cable
MR-20 Supplying with errection of 11 KV 1C x 99 sq.mm AAAC Cover conductor as required and as directed by the deptt.
MR-21 Supplying with errection of Termination Kit for 11 KV 1C X 99 Sq.mm AAAC Covered Conductor as required and as directed by the Deptt.
MR-22 Supplying with fitting and fixing of H.T. bushing as required and specified by the Department.
MR-23 Supplying with fitting and fixing of L.T. bushing as required and specified by the Department.
MR-24 Supplying of Transformer Oil as required and specified by the Department.
MR-25 DTR Fencing as per REC standard specification complete with materials & Labour. (As per APDCL Rate for SOR-2020-21)
Payment to be made to APDCL authority against Load Security
DHARAMSING NARZARY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .