Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC AMBEDKAR PARK AND RAWAT PG HOUSE WARD NO 10 KHASRA NO 2435 DEHRADUN UTTARAKHAND 248 140 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248140 | ₹8.2 L Quoted ₹8.7 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹9.1 L+₹42,088.50 (4.85%)Rejected-AOC M S 4BC PITAMPURA DELHI 110034 | DELHI | NORTH WEST DELHI | DELHI | 110034 | ₹9.1 L+₹42,088.50 (4.85%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹9.3 L+₹65,976.10 (7.60%)Rejected-AOC | ₹9.3 L+₹65,976.10 (7.60%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹10.8 L+₹2.1 L (24.5%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹10.8 L+₹2.1 L (24.5%) | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹12.5 L
EMD Value
₹25,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR / MAINT OF LT PANELS, FEEDER PILLAR BOX AND LT UG CABLES AND OH LINES AND CERTAIN ALLIED WORKS AT DEAL AREA UNDER GE (I) RND DEHRADUN
2024_MES_667199_1
GE(I)RND/9378/E8/24-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dehradun
Class E Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹25,000
Yes
8 Oct 2024
22 Jul 2024
16 Sept 2024
22 Jul 2024
13 Sept 2024
5 Aug 2024
22 Jul 2024 - 5 Aug 2024
Amount
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. complete all as specified and directed including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed.
M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
Fixing / laying only old PCC cable cover of any description as obtained from dismantling of the cable complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ corroded GI tubing of any description and in any position complete all as specified and directed.
Supplying, laying & jointing GI water tubing, 100 mm bore, medium grade as in sleeving etc laid in trenches / ducts etc. complete all as specified and directed.)
Supplying, laying & jointing GI water tubing, 80 mm bore, medium grade as in sleeving etc laid in trenches / ducts etc. complete all as specified and directed.
Dismantling & taking out unserviceable steel & iron items from poles and Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed. (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
16 Sqmm 4 core
35 Sqmm 3½ core
50 Sqmm 3½ core
120 Sqmm 3½ core
150 Sqmm 3½ core
Dismantling & taking out of old existing unserviceable insulators of any description and in any position from LT poles complete all as specified and directed.
Supply & fixing pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 100mm height and 65mm dia suitable for working pressure upto and including 1100 volts grade complete all as specified and directed for LT lines fixed on poles.
Supply and fixing shackle type porcelain vitreous, white, brown or green insulator for working pressure 1100V of 115mm dia and 100mm high including galvanized mild steel strip 31 x 3mm, insulator bolts 14mm dia washer and nut complete all as specified and directed for LT lines fixed on poles.
Dismantling & taking down of existing worn out / unserviceable aluminium conductor, steel reinforced (ACSR) of any description /size & in any position from existing LT Poles/Lines complete all as specified and directed.
Material & labour of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines including stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified and directed.
Supplying and fixing MCCB, 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu100% = 35/36 KA with adjustable thermal & magnetic setting, of complete all as specified and directed. Make : Legrand/Seimens/Schnieder/Havells/ C&S/Indoasian
Supplying and fixing MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Ics = 100% of Icu 35/36 kA with adjustable thermal & magnetic setting complete all as specified and directed.
Supplying and fixing MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with adjustable thermal & magnetic setting, complete all as specified and directed.
Supplying and fixing MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with adjustable thermal & magnetic setting,complete all as specified and directed.
Supplying and fixing MCCB, 160 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting,complete all as specified and directed.
Supplying and fixing MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting, complete all as specified and directed.
Supplying and fixing MCCB, 63 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity Icu = 25 kA with fixed thermal & magnetic setting, complete all as specified and directed.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of front operated OFF Load type changeover switch 4 pole, 415 volts, 400 Amps consisting of 1N switch , 1N operating Handle and 2 N top screw with sheet enclosure complete all as specified and directed.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of Euroload Load type changeover switch 4 pole, 415 volts, 320 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHCNFEO320 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of Euroload type changeover switch 4 pole, 415 volts, 200 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHCNFE0200 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated OFF Load type changeover switch 4 pole, 415 volts, 200 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0200 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting & taking down old existing unserviceable changeover switch of any description and in any position complete and Supplying, fixing, testing and commissioning of side operated ONLoad type changeover switch 4 pole, 415 volts, 100 Amps with and including sheet enclosure complete all as specified and directed. Cat part No: IHBFFE0100 of make Havells or equivalent model of specified make as approved by GE.
Disconnecting and Taking out old unserviceable LT Panel any type and shape, size, and Supply, installation, testing and commissioning out door type factory made kisok cubicle type, dust and vermin proof of suitable size IP class protection made of 3mm thick CRCA sheet and angle iron 50X50X6mm frame, TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, painting with two coat of smoke grey synthetic enamelled paint over a coat of red oxide primer on PCC platform 100 mm thick made out of PCC 1:3:6, 1 mtrs all round the panel board suitable for 3 phase 4 wire 415 V, 50 Hz factory fabricated in an approved factory having modern fabrication and comprising of following :- (Location - Sub stn No 3) (i) Incoming :- (a)ACB , 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity , 50 KA drawout typed with microprocessor release IPR E , Qty – 01 Make:Legrand/Schnieder/Siemens/Havells) (b) Digital Ammeter 3 Phase AC 0 – 1000 Amps, with 3 current transformer of suitable ratio and capacity Qty -01 No. (c) Indicating lamps LED type for three phases -R Y B of 3 Nos, (d) Digital Voltmeter 3 Phase AC 0 – 500 Volts.Qty -01 No. (e) Aluminium bus-bar of 800 Amps rating TPN -01 Set (ii) Out Going :- (a) MCCB, 400 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 35 KA with adjustable thermal & fixed magnetic setting, Qty – 01 No.(Make: Legrand/Schneider/Siemens/Havells/C&S)
a) MCCB, 250 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 35 KA with adjustable thermal & fixed magnetic setting, Qty – 01 No.(Make: Legrand/Schneider/Siemens/Havells/C&S) (b) MCCB, 200 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 35 KA with adjustable thermal & fixed magnetic setting, Qty – 4 No.(Make: Legrand/Schneider/Siemens/Havells/C&S) (c) MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 35 KA with adjustable thermal & fixed magnetic setting, Qty – 3 No.(Make: Legrand/Schneider/Siemens/Havells/C&S)
Disconnecting and Taking out old unserviceable LT Panel any type and shape, size, and Supply, installation, testing and commissioning out door type factory made kisok cubicle type, dust and vermin proof of suitable size IP class protection made of 3mm thick CRCA sheet and angle iron 50X50X6mm frame, TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, painting with two coat of smoke grey synthetic enamelled paint over a coat of red oxide primer on PCC platform 100 mm thick made out of PCC 1:3:6, 1 mtrs all round the panel board suitable for 3 phase 4 wire 415 V, 50 Hz factory fabricated in an approved factory having modern fabrication and comprising of following :- (Location -Satcom) (i) Incoming :- (a) MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, with suitable enclosure Qty – 01 Make:Legrand/Schnieder/Siemens/Havells) (b) Digital Ammeter 3 Phase AC 0 – 500 Amps, with 3 current transformer of suitable ratio and capacity Qty -01 No. (c) Indicating lamps LED type for three phases -R Y B of 3 Nos, (d) Digital Voltmeter 3 Phase AC 0 – 500 Volts.Qty -01 No. (e) Aluminium bus-bar of 600 Amps rating TPN - 01 set
(ii) Out Going :- (a) MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 25 KA with adjustable thermal & fixed magnetic setting, Qty –8 No. (Make: Legrand/Schneider/Siemens/Havells/L&T) (b) MCCB, 160 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity , 25 KA with adjustable thermal & fixed magnetic setting, Qty – 02. (Make: Legrand/Schneider/Siemens/Havells/L&T (c) On load Change over switch of cap 400 Amps, 4 pole, 415 Volts, AC supply, with sheet metal enclosure with adjustable thermal & fixed magnetic setting, Qty – 01 No. (Make: Legrand/Schneider/Siemens/Havells/L&T Note : (i) The contractor shall submit proposed drawing of the panel interlia mentioning make of switchgears to be incorporated alongwith name of panel manufacturer for approval of GE before manufacturing. (ii) The quoted rate is inclusive of the cost of danger notice plate of suitable size and marking of letters with PVC sheet/ Stickers such as incoming and outgoing and capacity of breakers etc. (iv) The cost of fixing of the panel on suitable PCC (1:3:6) type C-1(using 20 mm graded black trap/basalt/granite stone aggregates) foundation as directed by Engineer-in-Charge is deemed to be included in the quoted rates by the contractor for the above item. (v) The bottom of panel shall have minimum 45cm height from existing ground / floor level.
Dismantling, taking down and removing the old existing un serviceable non-functional/broken GI sheet/hinges of any description and in any position of existing feeder pillar boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 50 mm long medium weight mild steel butt hinges in position and necessary GI sheet for door of panel/main switch etc with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed. (Note :- Each hinge point and joint of GI sheet shall be measured as one unit. )
-ditto- but supplying and fixing new cold rolled 100 mm long medium weight mild steel butt hinges in position –ditto-
M & L for servicing of feeder pillar box, after dismantling the incoming and outgoing connections from MCCB/ Bus bar and replacing the old burnt/ overheated unserviceable lugs, terminals, nuts, bolts, washers supporting insulators etc and checking the serviceability of MCB / MCCB, earth continuity conductor and strip etc complete all as specified. Note: (i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) Labour for fixing charges of the spare parts deemed to be included in the rate quoted for the items.
Supply only aluminium lugs of any type / shape of capacity 150 Sqmm
Supply only aluminium lugs of any type / shape of capacity 120 Sqmm
Supply only aluminium lugs of any type / shape of capacity 95 Sqmm
Supply only aluminium lugs of any type / shape of capacity 70 Sqmm
Supply only aluminium lugs of any type / shape of capacity 50 Sqmm
Supply only aluminium lugs of any type / shape of capacity 35 Sqmm
Supply only aluminium lugs of any type / shape of capacity 25 Sqmm
Supply only aluminium lugs of any type / shape of capacity 16 Sqmm
Supply only GI Nuts, bolts, screws, washers of required sizes
Supply only bus bar Insulators Epoxy type as required at site min size 45mm x 50 mm dia
S&F Extension link four set suitable for MCCB in existing panel of capacity DPX 125/160 Amp.
S&F Extension link four set suitable for MCCB in existing panel of capacity DPX 250 Amp.
S&F Extension link four set suitable for MCCB in existing panel of capacity DPX 400/600 Amp.
Taking down unserviceable indication lamp and supplying, fixing, testing and commissioning indication lamp (LED type) with showing red, yellow and green in colour of 22.5 mm dia monitor on LT panel board suitable for 240 V AC supply all as specified and directed. Make : L&T /Binay.or equivalent approved.
Disconnecting, dismantling, taking out & removing unserviceable volt meter and Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96mmX96mm with adopter complete with button all as specified and directed. Make : ENERCON/AE Note :- The rate quoted shall be deemed to including the following:- (i) Control wiring for auxiliary supply 230 Volts AC if required. (ii) Cutting the sheet of the panel to suit with existing panel if required. (iii) Calibration and testing the meter.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15 cm thickness (above or below ground floors) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in cills, steps, copings, holdfast and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work complete all as specified and directed.
Supplying, Fixing, jointing and testing for provision of straight through joints,complete with jointing materials and accessories , suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables complete all as specified and directed.
95 Sqmm to 120 sqmm 3½ core
150 Sqmmto 185 sqmm 3½ core
Supplying, Fixing, jointing and testing for provision of Heat Shrinkable outdoor termination cable jointing kit , suitable for XLPE, LT Cable, 1100 Volts grade, for the following sizes of cables complete all as specified and directed.
70 Sqmm to 150 sqmm 3½ core
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified and directed. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
Material and labour in replacement of UNSV GI strip of size 32mm x 6mm for laying along the wall/roof on batten or burried in ground or drawn in conduit pipe or fixed to poles or any other situation as directed or as required GI strip of size 32mm x 6mm earth continuity conductor complete with all accessories such as porcelain insulators, saddles and fixing screw etc for conductor all as specified and directed.
All as per item No.65 here in above but using 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Disconnecting, dismantling, taking out & removing unserviceable MCCB box and Supplying and fixing of MCCB box of range 200 amp to 400 amp capacity complete all as specified and directed.
Friends fire Engineers (BID ID -3093862)
KISHORE ENTERPRISES (BID ID -3095136)
JS CONSTRUCTION COMPANY (BID ID -3090051)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .