| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest. | |
| 2 | Shri Radhakrishna Associates L2₹34.5 L+₹2.9 L (9.19%)Rejected-AOC | L2 | Rejected-AOC Rejected not being lowest. | |
| 3 | L3₹61.4 L+₹29.8 L (94.4%)Rejected-AOC A 306 SAISHA RESIDENCY PLOT NO 99 SECTOR 35 KAMOTHE RAIGAD MAHARASHTRA 410209 UDYAM MH 27 0136235 | RAIGAD | MAHARASHTRA | 410209 | L3 | Rejected-AOC Rejected not being lowest. | |
| 4 | Rejected-Technical | - | Rejected-Technical Variation in Name of bidder and documents uploaded | |
| 5 | Rejected-Technical VILL BHANGERI PO ROORKEE PIN 247667 | HARIDWAR | UTTARAKHAND | 247667 | - | Rejected-Technical Not enlisted in appropriat catogary |
Tender Value
Refer Docs
EMD Value
₹82,100
Closing Date
27 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
PROVN OF ARBORICULTURE FOR OTM ACCN AT ROORKEE UNDER GE ROORKEE
2023_MES_589366_1
95212/RKE/E8
Open Tender
Civil Works - Others
Item Rate
180 days
Roorkee
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Roorkee
₹82,100
28 Jun 2023
13 Apr 2023
3 Jun 2023
13 Apr 2023
27 May 2023
13 May 2023
Amount
Surface dressing n. exc 15cm deep and getting out soft/loose soil, complete all as specified and directed by Engineer in charge
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed by Engineer in charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer in charge
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in charge
M & L filling of earth soil complete all as specified and directed by Engineer in charge
M & L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed by Engineer in charge
M & L Providing precast cement concrete Type B1 (1:2:4) (20 mm graded aggregate ) in win-dow or door cills, lintels, bressumers, steps, quoin blocks (for use with ma- sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stonewalling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham- fers, weatherings, throat- ing etc. and setting in mortar complete with but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed by Engineer in charge
M&L for Cement concrete(1:4:8) Type D2 (40 mm graded in foundations, filling and mass concrete.(1;4;8) As Lean Conc. Below Footing. Complete all as specified and directed by Engineer in charge
Form work to sides of concrete foundations, footings, bases of columns, sides & soffits of foundation and plinth beams and similar work for rough finished flat surfaces of concrete complete all as specified and directed by Engineer in charge
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed by Engineer in charge
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed by Engineer in charge
M&L For RCC (M-30) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer in charge
M&L For RCC (M-30) in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed by Engineer in charge
M&L For RCC (M-30) in RCC Columns, pillars, piers, posts and struts compete all as specified and directed by Engineer in charge
M&L for Rendering 10mm thick on fair faces of brick work or concrete sur- faces in CM (1:4) complete all as specified and directed by Engineer in charge
M&L 10 mm thick rendering on Internal wall in CM (1:4) on RCC Wall with WPC compound @ 2 % of cement, complete all as specified and directed. Note: WPC shall be paid seperately complete all as specified and directed by Engineer in charge
Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia .complete all as specified and directed by Engineer in charge
-ditto- all as per item No above but 5 mm dia and over upto and incl 10 mm dia in stirrups, spacers and binders.complete all as specified and directed by Engineer in charge
Returning, filling in soft and disintegrated in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each .complete all as specified and directed by Engineer in charge
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point .complete all as specified and directed by Engineer in charge
M&L for 300x300x10mm thick heavy duty exterior vitrified tiles with digital print ("Durastone of somany tiles/"Endura" of Jhonson/"Duratech" of Kajaria) (colour and shade as approved by GE) in floors, set & jointed in neat cement slurry & pointed out in white or coloured cement with and including over 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer in charge
M&L for 300x300x10mm thick heavy duty exterior vitrified tiles with digital print ("Durastone of somany tiles/"Endura" of Jhonson/"Duratech" of Kajaria) (colour and shade as approved by GE) in Walls , set & jointed in neat cement slurry & pointed out in white or coloured cement with and including over 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer in charge
M& L WPC @ 2% by weight of Cement complete all as specified and directed by Engineer in charge
S&F 20 mm wide Rubber water stop Bentonite water stop strip for concrete structure , complete all as specified and directed by Engineer in charge
M& L for 100 mm thick Providing Gravel / Stone Pables in Park complete all as specified and directed by Engineer in charge
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall)12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed by Engineer in charge
M & L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed by Engineer in charge
Landscaping bed developing, dressing, cleaning, levelling, fertilizer & labour charges complete all as specified and directed by Engineer in charge
Supplying and Filling sweet earth free from lumps , grass and vegetation brought from out side of defence land including unloading at nearest point, filling in layer not exceeding 20 cm , consolidating each layer by ramming and watering including all lead and lift, complete all as specified and directed by Engineer in charge
M&L for grassing with bermuda grass with grass turf including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for moving with and including good earth, if needed in dibling complete all as specified and directed by Engineer in charge
M&L for digging holes 90cm dia and 90cm deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 Parts of earth : 1 Parts of manure or sludge) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts for following size complete all as specified and directed: Note : Cost of approved earth , sludge and dump manure deemed included in quoted rate.
Supply and Planting of following ornamental trees/plants in digged holes complete all as specified and directed by Engineer in charge. Palm Trees 9'-10' Length, Girth n.exc 300 mm complete all as specified and directed by Engineer in charge
All as per srl item No 33 above but Bottle palm 6'-7' Length , Girth exc 300 mm complete all as specified and directed by Engineer in charge
M&L for digging holes 60cm dia and 60cm deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 Parts of earth : 1 Parts of manure or sludge) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts for following size complete all as specified and directed by Engineer in charge. Note : Cost of approved earth , sludge and dump manure deemed included in quoted rate.
Supply and Planting of following ornamental trees/plants in digged holes complete. All as specified and directed by Engineer-in- Charge. Dracaena Mahatma, height exc 300mm complete all as specified and directed by Engineer in charge
All as per srl item No 36 above but Dracaena victoria, height exc 300mm complete all as specified and directed by Engineer in charge
All as per srl item No 36 above but Ribbon Grass, height exc 300 mm complete all as specified and directed by Engineer in charge
All as per srl item No 36 above but Fountain Red Grass, height exc 300 mm complete all as specified and directed by Engineer in charge
Developing and planting hedges by height of 30 cm above 30, 30cm apart saplings, including excavation in trenches to a width 45 cm and depth of 45 cm and filling the trenches with mixture of organic fertilizer and sweet soil in proportion of 2:3 with necessary pesticides treatment including watering , manuring , necessary pesticides etc complete all as specified and directed by Engineer in charge.Hedge Thunbergia erecta 1' complete all as specified and directed by Engineer in charge
All as per srl item No 40 above but Hedge Hemelia patens Dwarf 1' complete all as specified and directed by Engineer in charge
Supply and Filling Organic fertilizer (dry state) brought from outside including unloading at nearest point, filling in layer not exceeding 20 cm , consolidating each layer by ramming and watering including all lead and lift, complete all as specified and directed by Engineer in charge
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer in charge
M&L of Bricks common burnt clay building bricks sub class 'B' complete all as specified and directed by Engineer in charge
Supplying and fixing precat RCC garden benches at location to be decided by Engineer-in charge. as per drawing No CWE No2/TP/03 Sheet 1/1 dt 01 Apr 2023.. The RCC bench will consist of precast 5 Nos of RCC planks to be used for seating and back rest. Fixed with nut and bolt arranrement to two pre cast RCC bases of seating height 450mm back rest height from the ground is 1000mm and base width is 620mm. the lenght of the bench is 1500mm the bench shall be cast using M30 grade concrete mix as per IS 10269:2009 by using vibro compaction techique with reinforement as shen in the drawing. the complete assembly shall be spray painted with with three coats of synthetic emamel paint of colours to be decided by the engineer mecharge.
E/M Portion (A) FOUNTAIN & ELECTRICAL WORK S&F openwell horizontal submersible pump 3 phase 415 volt of capacity 3 HP/ 2.2 KW complete, including connecting all incoming and out going electrical connections complete all as specified and directed .
Supply fix testing and commissionning of DOL starter 415 Volt 3 phase of capacity 3HP/2.2 KW with Single phase preventer & 63 Amp 25 KA ,4 pole MCCB as incommer complete in sheet metal enclosure all as specified and directed.
Supply and fix water proof fountain LED light fitting under water capacity 3 to 6 watt in RGB 300oK-6000K, IP-68 240 volt DC 50 Hz energgy saver environmental friendly , luminaire white beam super magnifying lens surface/ clamp mounting with RGB LED controller (DMX 512) to control colouringg ratio of light making electrical connection with leakage proof three core copper cable all as per site requirement complete all as sspecified and directed.
Supply and fix constant voltage/current LED driver input AC 220-250 voltage output DC controller for electric circuit complete all as specified and directed.
Supply and fix PVC insulated PVC sheathed round copper conductor cable 10 core 1.50 sqmm 1100 volt grade complete all as specified and dierected.
Supply and fix umbrella nozzle of fountain made of brass water tubing heavy duty single pointed/ multi pointed nozzle round in shape including threading making holes welding cutting jointing fixing etc stay on high pressure etc complete all ass pecified and directed.
Supply and fixing Galvanised steel water tubing, medium grade 80 mm bore with all fittings such as bends tees union, socket, elbow, nipples etc laid in trenches in ground/ surfacecomplete all as specified and directed.
Supply, fix, test and connecting cast iron Sluice valve PN 1.6 of size 80 mm with iron wheel head, and SS spindle falnged both ends for GI pipe complete all as specified and directed.
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 16 sqmm 4 core complete all as specifed and directed. Note:- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
Supplying, laying, commisioning and testing of 1.1 KV grade XLPE insulated PVC sheathed, steel armoured aluminum stranded conductor LT UG cable ( Conforming to IS 7098) ISI marked in trenches / ducts / through GI pipes under roads of size 10 sqmm 4 core complete all as specifed and directed. Note:- The earth work, GI pipe shall be measured and paid sepretely under appropriate item of Sch A
S&F in replacement LED bollard light 9/10 Watt CDL/WW made out of pressure die cast powder coated housing with PC diffuser with LED as a source light including making electrical connection complete all as specified and directed.
(B) IRRIGATION Supply and fix UPVC pipes socketed 50 mm X 06 Kg/cm2 confirming to IS:4985 SCH-40 complete laid in trench for making water connection complete all as specified.
Supply and fix UPVC pipes socketed 40 mm X 06 Kg/cm2 confirming to IS:4985 SCH-40 complete laid in trench for making water connection complete all as specified.
Supply and fix UPVC pipes socketed 25 mm X 06 Kg/cm2 confirming to IS:4985 SCH-40 complete laid in trench for making water connection complete all as specified.
Supply and fixing of 50 mm UPVC ball valve plain ends having flow indicator when lever is removed, security pivot to maintain lever in space, double water tight joint, direct injection stem non mechanical with a base which permmits maximum penetration into the valve with Teflon Seal complete all as specified.
Supply and fixing of self closing spring loaded Plastic quick coupling valve of size 3/4" female along with thermoplastic Vinyl Chloride cover complete all as specified and directed.
Supply and fixing of plastic quick coupling Key Male 3/4" complete all as specified and directed.
Supply and fixing GI Pipe nipple 3/4" xx 2" to mount quick coupling valve complete all as specified and directed.
Supply and fixing of a double acting air release valve of working pressure 10 Bar made of engineering plastic 2" size. The air releasevalve is capable of both releasing and admitting air from and into the line complete all as specified.
Supply and fixing of fiber glass reinforced heavy duty plastic valve 10" (round) complete all as specified and directed.
Supply and fixing of PGP Pop up rotor Sprinkler discharge 0.23 lps R 11.9 mtr and adjustable R 40-360 degree with having female inlet of 3/4" operating pressure 2-4.5 kg/cm2 complete all as specified.
Supply and fixing 3/4" x 30 cm standard swing joint with 4 swivel Elbow complete all as specified.
Supply and fixing of HDPE pipe 16 mm for drip irregation system for vertical garden ma complete all as specified and directed.
('C)EARTH WORK Excavation in trenches in hard/dense soil n.exc 1.5 m wide and n.exc 1.5 m in depth for poles,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
Returning , filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, in any tupe of soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thickness of sand will be measured and paid.
M&L for well brunt bricks sub class 'B' in old size as cable protection laid flat width wise complete all as specified and directed.
S&F GI tubing light grade of dia 32 mm for cable protection complete all as specified and directed.
Shifting/ Rerouting of GI tubing of size from 50 to 100 mm , by opening the connections, unscrewing or cutting including cleaning for refixing and laid in other location as per direction complete all as specified and directed.
Shifting/ Rerouting of LT UG cable of size upto 70 Sqmm 3.5 core , by excavation and relocate the LT cable as per direction complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. (earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 25x4 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 40 mm dia light grade Gi pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighting not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items.
Shri Radhakrishna Associates
R C TRADING COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .