Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.8 Cr+₹8.5 L (4.89%)Admitted-Finance PUNDIT MANSION SHOP NO 7 1ST FLOOR BIDHAN MARKET ROAD SILIGURI 734001 DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹1.8 Cr+₹8.5 L (4.89%) | L2 | Admitted-Finance |
| 3 | L3₹1.9 Cr+₹14.3 L (8.25%)Admitted-Finance SENPARA DIST JALPAIGURI PIN 735101 | SENPARA | JALPAIGURI | WEST BENGAL | 735101 | ₹1.9 Cr+₹14.3 L (8.25%) | L3 | Admitted-Finance |
| 4 | L4₹2.0 Cr+₹23.4 L (13.5%)Admitted-Finance | ₹2.0 Cr+₹23.4 L (13.5%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Z STAR COMMOTRADE PVT LTD L4 | MALAY BANERJEE L1 | M/S KAMAK ENGINEERS AND CO L2 | BILTU DAS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of cubicle type both side openable Indoor type dust and vermin proof powder painted Panel board having fixed with front side double door with railway type locking arrangement suitable 415V 3 phase, 4 wire 50 Hz AC supply made out of 2 mm thick CRCA sheet so as to accommodate the following mountings complete with copper bus bar, cable allay & channel base at the bottom connection & interconnection by copper wire & strip along with Danger Board and necessary nuts & bolts complete as reqd. (L&T/Siemens/Schneider/Legrand)
415V, 36 Ka 400A 4P MCCB - 1 nos.
415V, 400A 4P Changeover - 1 nos.
415V 400A Bus Bar
415V, 36 Ka 250A 4P MCCB- 1 nos.
415V, 36 Ka 160A 4P MCCB- 1 nos.
415V, 36 Ka 63A 4P MCCB- 4 nos.
Indicating Lamp-3 nos.
Digital Voltmeter- 1 no.
Digital Ammeter- 1 no.
Danger Board- 1 no.
and all other accessories. | 1 | SET | 4,41,107.97 ₹4,41,107.97 | 3,89,383.98 ₹3,89,383.98 Lowest | 4,08,433.31 ₹4,08,433.31 | 4,21,503.18 ₹4,21,503.18 |
| 2.00 | Supplying and fixing double door 4 Way Vertical TPN MCB
Distribution board for MCCB incomer with IP-42/43
protection, on angle iron frame on wall & mending good
the damages to original finish incl. Inter connection with
suitable size of copper wire and neutral link & provision
for earthing attachment | 1 | set | 12,811.09 ₹12,811.09 | 11,308.88 ₹11,308.88 Lowest | 11,862.13 ₹11,862.13 | 12,241.71 ₹12,241.71 |
| 3.00 | Supplying and fixing double door sheet steel
(16SWG), powder coated cable end box for TPN
DB horizontal / vertical enclosure with IP-42/43
protection, on angle iron frame on wall & mending
good the damages to original finish with nuts bolts
etc incl. provision for earthing attachment | 1 | set | 1,591.92 ₹1,591.92 | 1,405.25 ₹1,405.25 Lowest | 1,474 ₹1,474 | 1,521.17 ₹1,521.17 |
| 4.00 | Supplying and fixing double door Horizontal 6 way TPN MCB
Distribution board with IP-42/43 protection, concealed
in wall after cutting the wall & mending good the
damages to original finish incl. Inter connection with
suitable size of copper wire and neutral link & provision
for earthing attachment | 1 | each. | 5,203.44 ₹5,203.44 | 4,593.29 ₹4,593.29 Lowest | 4,818 ₹4,818 | 4,972.18 ₹4,972.18 |
| 5.00 | Supplying and fixing double door 8 Way SPN MCB
Distribution board with IP-42/43 protection concealed in wall after cutting the wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment | 3 | set | 1,761.21 ₹5,283.63 | 1,554.69 ₹4,664.07 Lowest | 1,630.75 ₹4,892.25 | 1,682.93 ₹5,048.79 |
| 6.00 | Supplying and fixing 4 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as per instruction of EIC. | 4 | nos. | 469.26 ₹1,877.04 | 414.23 ₹1,656.92 Lowest | 434.5 ₹1,738 | 448.4 ₹1,793.6 |
| 7.00 | Supplying and fixing 415 V Four Pole MCCB of
Breaking capacity 25kA/35kA with fixed thermal
and fixed magnetic / adjustable thermal and fixed
magnetic setting in existing DBs / enclosure and
necessary connection
160 A FP MCCB | 1 | each. | 14,492.11 ₹14,492.11 | 12,792.78 ₹12,792.78 Lowest | 13,418.63 ₹13,418.63 | 13,848.02 ₹13,848.02 |
| 8.00 | Supplying and fixing 240/415 V MCB of Breaking
capacity 10kA & C characteristics on din rail of
existing DBs and necessary connection
63TP MCB | 2 | each. | 2,126.52 ₹4,253.04 | 1,877.17 ₹3,754.34 Lowest | 1,969 ₹3,938 | 2,032.01 ₹4,064.02 |
| 9.00 | 63 FP MCB | 1 | each. | 2,717.55 ₹2,717.55 | 2,398.89 ₹2,398.89 Lowest | 2,516.25 ₹2,516.25 | 2,596.77 ₹2,596.77 |
| 10.00 | (6-32) A DP MCB | 7 | each. | 810.81 ₹5,675.67 | 715.74 ₹5,010.18 Lowest | 750.75 ₹5,255.25 | 774.77 ₹5,423.39 |
Tender Value
Refer Docs
EMD Value
₹2.5 L
Closing Date
16 May 2025, 3:00 pmClosed
NIRANJAN KUMAR DAS/SE-Elect/NBDD
NBDD uttarkanya
Electrification work including Compound lighting with Ornamental Pole, installation of CCTV,DG Set, Off Grid Solar and Glow Sign Board of Swimming Pool at Dinhata in the District of Coochbehar.
2025_NBDD_836562_9
NBDD/BS/SE /NIQ-03- (EL) of 2025-2026
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Coochbehar
Please refer Tender documents.
6 documents required · 6 mandatory
₹2.5 L
Yes
23 May 2025
17 Apr 2025
19 May 2025
17 Apr 2025
16 May 2025
17 Apr 2025
Amount
Supply, installation, testing & commissioning of cubicle type both side openable Indoor type dust and vermin proof powder painted Panel board having fixed with front side double door with railway type locking arrangement suitable 415V 3 phase, 4 wire 50 Hz AC supply made out of 2 mm thick CRCA sheet so as to accommodate the following mountings complete with copper bus bar, cable allay & channel base at the bottom connection & interconnection by copper wire & strip along with Danger Board and necessary nuts & bolts complete as reqd. (L&T/Siemens/Schneider/Legrand) 415V, 36 Ka 400A 4P MCCB - 1 nos. 415V, 400A 4P Changeover - 1 nos. 415V 400A Bus Bar 415V, 36 Ka 250A 4P MCCB- 1 nos. 415V, 36 Ka 160A 4P MCCB- 1 nos. 415V, 36 Ka 63A 4P MCCB- 4 nos. Indicating Lamp-3 nos. Digital Voltmeter- 1 no. Digital Ammeter- 1 no. Danger Board- 1 no. and all other accessories.
Supplying and fixing double door 4 Way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
Supplying and fixing double door Horizontal 6 way TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing double door 8 Way SPN MCB Distribution board with IP-42/43 protection concealed in wall after cutting the wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
Supplying and fixing 4 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as per instruction of EIC.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 160 A FP MCCB
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 63TP MCB
63 FP MCB
(6-32) A DP MCB
(6-32) A SP MCB
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Average run 9 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC On Board
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board JVith top cover plate incl. making necy. Connections etc ..
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire.
Supply & Fixing louver shutter on wall with necy. Bolts & nuts (6 mm dia x 62 mm long) For GI 23 cm Exhaust fan (9")
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23MM (9")
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3x1.5sqmm
2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
2x80/0.4 (10 sqmm) + 1x84/0.3 (6 sqmm) as ECC
4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
Supply of recess/ Surface mounted 18 W LED down light which range is brake through technology and reliable heat management to deliver a long lasting efficient solution.
Supply ,Transportation, Loading & unloading of Industrial box type luminaire suitable for single T8 LED tube of 20w (4ft) for SINGLE batten and LED tube of 20w with extruded aluminium body.
supply of 250 V 48"(1200mm) sweep BLDC ceiling fan with 50% energy consumption complete with blades, condencer, canopy, down rod etc. complete and suitable for 23,Ov ac operation.
AC Exhaust fan Of 10"(300mm) sweep, turbo, Grey with fan motor,condencer, Ftame, Blade etc, complete and suitable for 230v ac operation.
Supply of high speed wall mounting bracket fan 240 V 400 mm sweep fixed with close mesh guard , pull chain arrangement for speed control and sturd and heavy duty blades for higher displacement of air .
supply and fixing of angular batten with 9 Watt LED Bulb
Supply of LED Bulkhead that fits in vartiety of applications and serves as simple energy efficient alternative to CFL/incandescent bulkhead luminaires
Fixing only bulk head /ceiling fitting on wall /ceiling by screws etc.
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 50 mm dia
80 mm dia
Compound Lighting: Supply and delivery of 3 Meter Decorative Pole, Single Arm With Single Light ornamental poles with LED post top lantern (including lamp) made out of cast aluminium embellishments. The pole s are primer coated and painted with polyurethane paint. Poles are suitable for Single side Luminaires. The poles have a service window at the bottom comprising four way 25Amp connector terminal and a MCB. Poles can be mounted with four numbers Anchor bolts as per foundation details provided by Manufacturer's company. (Make-HPL/K-LITE/Orient) as approved by EIC.
Supply and providing of suitable size & height of 461mm X 461mm CC foundation including erection the pole and depth below the G.L 1000mm approx. including fixing of existing 4 nos foundation nuts & bolts with washer and cement plaster & neat cement polish,painting or as per direction of E-I-C and G.S.
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works 25 mm dia
Supply ,Transportation, Loading & unloading of following types of 1.1KV grade XLPE 1.1kv grade AI armoured XLPE cable 2 CORE 10 sq. mm
i) 3.5 core X 70 sq.mm.
i) 3.5 core X 300 sq.mm.
2X2.5 SQMM UN ARMOURED CU CABLE for under water lights
4X4 SQMM UN ARMOURED CU CABLE for connecting pump to control panel. For location in Plant Room for Re-circulating Pump.
2X1.5 SQMM UN ARMOURED CU CABLE for connecting pump to control panel. For location in Plant Room for DOSING PUMP.
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With out angle iron support 200x50x1.25mm (18SWG)
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire upto 50 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 CORE 10 sq. mm
i) 3.5 core X 70 sq.mm.
i) 3.5 core X 300 sq.mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 CORE 10 sq. mm
i) 3.5 core X 70 sq.mm.
i) 3.5 core X 300 sq.mm.
Supply & Fixing EI danger board on wall 15 cm x 10 cm (6"x4")
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below. By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 8636 cm x 46 crn deep (below Ground level) complete with cemented brick work(I:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size ,36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate electrode
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 rnm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to bolts, nuts, washers cable lugs etc. as required and mending good damages Solid GI wireNo. 8 SWG
Sign Board Supply & lnstallation of 6" depth box type M,S. structure duly fabricated &.welded by 40 mm x 40 mm M.S. square pipe 3 mm thick lSI mark frame with back side & four sides covered by 24SWG MS sheet including Aluminium channel and fixing arrangement without ACP sheet includiug painting,. slze :20' x 6.5' to be made such a manner that it can be opened towards up direction for taking maintenance.
S&F 4mm thick white ACP sheet on MS structure. Size 20 ftX 6.5 ft
Supply & fixing of special type imported acrylic letter suitable height as per site requirment fixed on ACP sheet.The letter front( English/Bengali bold) letter colour- Blue
Supply & fixing of LED inside the acrylic letters. the specification of lED is given below; a) LED white samsung (Korea) module. ( 3 nos. LED in a module) b) type:double line fixed. c) Life:70,000 burning hours. d) Intensity- same & smooth through out no brighter or light or dark patches. e) Visibility: 50 mtr. at least for normal eye. f) Power supply: required amp (mean well LRS·< >-12) g) Ambient air 0-50 c 100% relative humidity. h) Power consumpdon: 1.08 watt per module.
S & F water proof 350 watt power supply system [P65. 50/60 Hz frequency 108 to 305 VAC power supply, >.095 power factor for LED lamp, (Make: Meanwell /Groen)
S&F 50mm X 50mm X 6mm MS angle on wall including painting for fixing of sign board.
Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
(a) Under water Lights. Delivery, supply, erection, testing and commissioning of Under water lights of Type - Under water light with cable with niche. The flood lamps shall complay with P68 degree of protection and should be resistant to dust, soild bodies and humidity, M, Lamp watts - 20 Watt Led, Bulb voltage -12V, Candescant, Size - 280 mm X 150 mm including all accessories, fitting, fixing, all Taxes & T&eP required for the work complete as per direction of EIC
(b) Junction Box/ Deck Box. Delivery, supply, erection, lesting and commissioning of Junction Box / Deck Box having Material of Construction ABS No of Inlet - 3, Size of Inlet-3/4 Threaded Capacity including all accessories, fitting, fixing, all Taxes & T&P required for the work complete sper direction of EIC
(c) Flexible Conduit. Delivery, supply, erection, testing and commissioning of Flexible Conduit, Length of conduit -1 M, End Connection -3/4* Threaded End, Purpose - For connecting light to junction box including all accessories, fiting, Fixing, all Taxes & T&P required for the work complete as per direction of EIC
OUT DOON PANEEL FOR UNDER WATER LIGHTS (a) Contriler: Delivery, supply, erection, testing and commissioning of motor control centres fabricated from 16 gauges MS sheet with necessary double door, gasket , MCB switch ,channel for fixing controller/Transformer, Input Power supply -220/240 V, Output power supply -12 -16 V, Current -400 VA, Protection -ENG0742 inchuding all accessories, fiting, fixing, all Taxes and T&P required for the work complete as per direction of EIC
PRESSURE TYPE IRON ELIMINATION PLANT:- Supplying, Fabrication, Erection on suitable RCC foundation and Commissioning with 3 (three) months Trial Run (including cost of routine testing of water sample for performance evaluation) of pressure type Iron removal plant as per design norms of the P.H.E. Dte. with necessary accessories viz. MS fabricated shell with minimum 10 mm thick MS plate with 2 (two) coats of anticorrosive paint & minimum 12 mm thick MS media supporting plate fitted with required no. of pot strainer, MS fabricated oxidation chamber with minimum 10 mm thick plate with necessary pipe connection, valves, Gauges & other instruments as required as per departmental approved design & drawing including cost of filter media, Air Compressor & Air blower with motor, starter, main switch etc. of required capacity & approved specification including power connection from main line etc. all complete. 25 cum/hr
Supply & Installation of 60 KVA DG Set:(make-JAKSON/ KIRLOSKAR/ ASHOK LEALAND) Supply, Testing & Comissioning of 60KVA Silent Diesel Generator Set, water cooled, developing of CPCB-IV+ ENGINE with 12/24 volt self starter arrangement including rated DC 12/24V battery, mechanical governor with Gen Set controller, natural aspiration having dry tye air filter couled with Alternator capable of developing 62.5 KVA at 415V 50Hz at 1500 rpm, 3-phase 4-wire conforming to BS EN 60034-1/IS:4722 and will be suitable for tropical condition brushless type, screen protected, revolving field self excited self regulator through AVR, IP protection: 23, permissible overload of 10% for one hour in 12 hrs of operation. Class-H insulation, voltage regulation+1% DG mounted on base with AVM pad complete all as direted adn housed in accoustic enclosure required for Emergency Power Supply.
Installation Earth excavation of foundation trenches or drains, in all sorts of soil ( including mixed soil but excluding laterite or sandstone ) including removing, spreading or stacking the spoils with in a lead of 75 m as directed . The item includes necessary trimming the sides of trenches , levelling dressing and ramming the bottom, bailling out water as required complete. (a) Depth of excavation not exceeding 1500 mm.
Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
Ordinary cement concreat (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement , if any ,in ground floor as per relevent IS codes. (a) River bazree.
Brick work with 1st class bricks in cement mortar (1:6)ln foundation and plinth
Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Controlled Cement concrete with well graded stone chips (20 mm graded nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineerin charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture] (a) M 20 Grade (Pakur Variety)
Plaster ( to wall, floor ,ceiling etc ) with sand and cement morter including rounding off or chamfering corners as directed and raking out joints including throating , noising drip course, scaffolding / staging where neccy. (ground floor ). [ Excluding cost of chipping over concreat surface) . (a)with 1:4 cement morter 15mm thick plaster.
Neat cement punning about 1.5 mm thick in wall ,dado,window,sills,floor,drain etc.
M.S. Structural works in columns, beams etc. With simple rolled structural members (e.g. Joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)-1964 connected to one another with bracket, gussets, cleats as epr design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816-1956 & IS: 1995 using electrodes of approved make and brand fonforming to IS: 814-1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc. For Structural Works in Roof Trusses etc using joists, channels and angles of specified section weighing less than 22.5 kg/m.
Galvanised corrugated iron sheet work (excluding the supporting frame work) fitted and fixed with 10 mm dia J or L hook-bolts, limpet and bitumen washers and putty complete with 150 mm end lap and one corrugation minimum side lap (Payment to be made on area of finished work) (GCI sheet to be supplied by contractor). (i) In Roof: (a) With 0.63 mm thick sheet.
Supply and fixing 100mm dia M.S pipe to extend the exhaust pipe line including welding,bend,reducers and all accessories as required at site or as per E-I-C.
Supply of 1.1 KV following grade PVC/Armoured AL cable with 2XlO SWG GI wire as earthing attachment and mending good all damages to building works.(Polycab/Crystal/ KEI) a) 3.5 core X50 sq.mm
Laying of one no cable above 35 sqmm and upto 185 sqmm in under ground trench 460mm wide x760mm average depth , with brick protection on the top of the cable with 8(eight) nos. Bricks per meter including filling the space between the bricks and cable and also the trench with shifted soil , leveling up and restoring surface duly rammed.
Supply and fixing compression type cable gland complete with brass gland, brass ring and rubber ring for dust and moisture- proof entry of XLPE/PVC armoured cable. (a) For 3.5 core x 50 sqmm size.
Finishing of the above cable ends by soldering with cable sockets and insulated tapes etc, including supplying sockets, soldering materials , tapes etc . and making connection to switch. (a) For 3.5 core x 50 sqmm size.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the Ground (for Morrum soil)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe.
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991) 200A Capacity 415 Volt 4 bar AL busbar of bars size 50mmX5mmX1mtr-1 No.
Supplying and fixing 415V, 200A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(L&T)
Supplying and fixing 415V, 100ATPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(L&T)
Supplying and fixing 415V,100A FP Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc.(HAVELLS)
Supplying & Fixing of 40 mm GI pipe (ISI-M)
Supply and filling of diesel oil for trial run of the set.
Installation of CCTV surveillance: Supply, installation, testing & commissioning of IP IR Indoor/Outdoor Bullet Camera, pole / wall / ceiling mount 1/3" 3 megapixel progressive scan CMOS, 2304 (H) × 1296 (V), H.264, Auto/Manual, 1/3(4)–1/100000 s, 0.1 lux, F1.4 (Colour); 0 lux (IR LEDs on), Up to 30 m (100 ft) IR range, 2.7–12 mm F1.4 motorized focus/zoom lens, Built-in PoE, IP66 Rated, ONVIF Profile S, Profile G, Supports up to 128 GB microSDHC, including power supply units and all ancillary equipment & all accessories complete. [Make: as directed by E-I-C].
Supply, installation, testing and commissioning of 16CH NVR, 2 SATA HDD Slot (Max 8TB), 12VDC,Realtime Recording Resolution (32 Channels @ 720P,24 Channels @1080P),Realtime Local Playback( 8 Channels @ 720P,4 Channels @1080P),Multiplex Operation,H.264 High profile,BNC/VGA/HDMI output, main profile, baseline,HDD Redundancy,Free DDNS,Network backup, USB HDD, USB writer, SATA writer,1 RS485, support 18 kinds of PTZ protocols,ONVIF 2.0,1 channel Audio Input and Output. [Make: as directed by E-I-C].
Supply & installation of Surveillance HDD 4 TB each [Make: as directed by E-I-C].
Supply & installation of 42U rack complete with all accessories . [Make: as directed by E-I-C].
Supply, of 22" LED color monitor with HDMI Port [Make: as directed by E-I-C].
Supply, installation, testing and commissioning of 8 port- gigabit-10/100/1000, poe switch.[Make: as directed by E-I-C].
Supply & Installation of Desktop having specification: i3, 6 generation, 4GB RAM, 1TB HDD, 18.5" LED Monitor, Speaker 2.0, Wifi Keyboard & Mouse with genuine Windows 10. [Make: as directed by E-I-C].
Supply & laying of 6 core fiber optic cable./ CAT6 Cable. [Make: as directed by E-I-C].
Supply, Installation, Testing & Commissioning of 20kwp Solar Photovoltaic Panels. Poly Crystalline 310Wp to 325Wp (Each) (Make: VIKRAM / WAREE / JINKO / SOVA/ ADANI) The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon Solar Cell Modules IEC 61215/IS14286 .The rated output power of any supplied module shall have tolerance of +/- 3%.The peak-power point voltage and the peak-power point current of any supplied module and/or any module string (series connected modules) shall not vary by more than 2 (two) per cent from the respective arithmetic means for all modules and/or for all module strings, as the case may be.The module shall be provided with a junction box with either provision of external screw terminal connection or sealed type and with arrangement for provision of by-pass diode. The box shall have hinged, weather proof lid with captive screws and cable gland entry points or may be of sealed type and IP-65 rated.
Supply & Fixing Module Mounting Structure: Hot dip galvanized MS mounting structures may be used for mounting the 10kwp modules/ panels/arrays. Each structure should have angle of inclination as per the site conditions to take maximum insolation.The mounting structure steel shall be as per latest IS 2062: 1992 and galvanization of the mounting structure shall be in compliance of latest IS 4Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts.Thiknes of Galvanization shall be more than 75µ. Aluminium structures also can be used which can withstand the wind speed of respective wind zone. Necessary protection towards rusting need to be provided either by coating or anodization.The minimum clearance of the structure from the roof level should be 300 mm [Design to be approved by EIC before fabrication].
Supply, Installation, Testing & Commissioning of 1 Nos. PV Array Junction Box (AJB) for 10kwp: a) The junction boxes are to be provided in the PV array for termination of connecting cables. The Boxes (JBs) shall be made of Powder Coated Aluminium /cast aluminium/M.S alloy with full dust, water & vermin proof arrangement. All wires/cables must be terminated through cable lugs. The JBs shall be such that input & output termination can be made through suitable cable glands.b) Each Junction Box shall have High quality Suitable capacity Metal Oxide Varistors (MOVs) / SPDs, suitable Reverse Blocking Diodes. The Junction Boxes shall have suitable arrangement monitoring and disconnection for each of the groups. Voltage: Max. 1000V DC [Make: Hensel/Spielberg/Citel/ABB/L & T/schneider/Elmax].
Supply, Installation, Testing & Commissioning of ACDB : Designed for 10kWp solar power plant with all protections as per MNRE guidelines. DC DPBs shall have sheet from enclosure of dust & vermin proof conform to IP 65 protection. The bus bars are made of copper of suitable size. Suitable capacity fuse & MCBs/MCCB shall be provided for controlling the DC power output to the PCU along with necessary surge arrestors . AC Distribution Panel Board (DPB) shall control the AC power from PCU/ inverter, and should have necessary surge arrestors. Interconnection from ACDB to mains at LT Bus bar while in grid tied mode.All switches and the circuit breakers, connectors should conform to IEC 60947, part I, II and III/ IS60947 part I, II and III. All the Panel’s shall be metal clad, totally enclosed, rigid, floor mounted, air - insulated, cubical type suitable for operation on three phase / single phase, 415 or 230 volts, 50 Hz.All indoor panels will have protection of IP54 or better. All outdoor panels will have protection of IP65 or better. [Make: Hensel/Spielberg/Citel/ABB/L & T/schneider/Elmax]
Supply, Installation, Testing & Commissioning of hybrid Solar Inverter Rating: 10kw, 3Ph Inverter, Make: HBL / INVT/ Power-One/Equivalent . Control : Microprocessor /DSP Capacity .Nominal AC output voltage and frequency : 220/415V, 1 Phase / 3 Phase, 50 Hz . Output frequency : 50 Hz . Max. DC input Power 8kW. MPPT Voltage Range 4000 VDC. Max. input current per MPPT 11-26A. Output Voltage Range - 220V/415V AC. Grid Frequency Synchronization range : +/- 5 Hz. Ambient temperature considered : -20o C to 60o C. Humidity : 95 % Non-condensing. Protection of Enclosure :: IP-65(Minimum) for outdoor. Grid Frequency Tolerance range : +/- 5 Hz. Grid Voltage tolerance : 280 V to 480 V. No-load losses : Less than 1% of rated power. Inverter efficiency(minimum) : >93%. Inverter efficiency (minimum ) : > 90%. THD : < 3%. Efficiency Measurement IEC 61683/ Equivalent BIS Std.Environmental testing IEC 60068-2 (1,2,14,30) / Equivalent BIS Std.Interfacing with utility grid IEC 61727. Islanding Prevention Measurement IEC 62116. EMI/EMC : IEC 61000-6-3>16 Amps IEC 61000-6-4<16 Amps. Safety: IEC - 62109-1 (2010/4) C - 62109-2 (2011/6).Battery VDC: 120VDC/192/VDC. Charger Capacity: 50A. (Protections) Over Load For 100% Load Buzzer Indication, 101% above Load Trips and Retry for 4times then Inverter shutdown, Output Short Circuit:Circuit Breaker On Mains, Shutdown on Inverter,Battery Reverse Protection: Circuit Breaker, Low Battery:Load Disconnection, Thermal Shutdown:Below 0°C and Above 93:C,lightening/Surge:Protected upto 4KV Surge, Solar Reverse:Blocking Diode is provided to Prevent reverse flow of current, Current Limiting for battery Charging:Available, Battery Charging Current:Battery current limit during low load on solar panel. (Charging)Charging switch OFF:It will charges form solar .Charging switch ON:It will charges from grid when solar charging current is Low.(Environmental)Operating Temperature:-10:C to 50:C,Relative Humidity:0-95%. Priority:Grid or Solar, LED Display:Mains,Charger,Output,Fault, LCD Display:Batter Voltage; I/P Voltage;I/P Frequency;O/P Voltage; Grid Charging Current; Solar Voltage; Solar Charging Current; Solar Units Saved KWH(up to 999.9Units); Load %; Over Load; Battery Low; UPS/INV Mode IGBT All above IEC’s should be from NABL/ IEC Accredited Testing Laboratories or MNRE Approved Test Centers/ International laboratories.
12-200Ah Solar Tubular Batteries-10 Nos with rack for 2hr backup Make: Exide/Quanta/HBL/Equivalent
Supply, Installation, Testing & Commissioning of System Earthings : Each array structure of the PV yard should be grounded/ earthed properly as per IS:3043-1987. The array field, PCU, ACDB and DCDB should also be earthed properly. Earth resistance shall not be more than 5 ohms. It shall be ensured that all the earthing points are bonded together to make them at the same potential. At least 4 nos ground pipe / plate electrod as per PWD schedule for system earthing with soil treatment & earth inspection pit and GI flat of suitable size & quantity should be considered [Make: OBO/Beterman/Gmax].
Supply of Remote Monitoring System (GPRS Type): The RMS system is integrated or External unit. The following parameters are accessible via the operating interface display in real time separately for solar power plant: AC Voltage., AC Output current, Output Power, DC Input Voltage, DC Input Current, Power produce, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault. vi. The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form. viii. Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided
Supply, Installation, Testing & Commissioning of Auto Claening System PV Module Clean
Supply, Installation, Testing & Commissioning of all items of this BOQ should comply to the detailed Technical Specification given.
Operation & Maintanance for 5Yrs
35 Sqmm 4 Core armoured PVC/XLPE Power cable
Providing and fixing carbon – di – oxide fire extinguisher consisting of welded MS cylindrical body, squeeze, lever discharge valve, fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, finished externa. Capacity 4.5 kg. ISI marked
Providing and fixing mechanical foam type ( ISI marked ) fire extinguisher consisting of welded MS cylindrical body, squeeze, lever discharge valve, high pressure discharge hose, discharge nozzle, suspension bracket ISI marked finished externally with red enamel paint and fixed to wall with brackets with internal charger .Capacity 9 liters
Providing & fixing water Co2 ( ISI marked ) extinguisher including all accessories with wall bracket with rawl plug. Capacity 9 liters.
Providing & fixing dry powder extinguisher consisting of welded MS cylindrical body, with discharge valve, nozzle and CO2 cartige and hanging arrangement complete Capacity 5 kg. ISI marked
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
d) Electronic Hooter cum speaker for fire alarm / evacuation signal, 6 watt capacity including base and module
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
j) Addressable control relay module. complete as required as per specifications
k) Addressable Control module for hooter. complete as required as per specifications.
M/S KAMAK ENGINEERS AND CO (BID ID -6379721)
BILTU DAS (BID ID -6380913)
Z STAR COMMOTRADE PVT LTD (BID ID -6369567)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .