Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAdmitted-Finance | ₹24.7 L | L1 | Admitted-Finance |
| 2 | L2₹25.8 L+₹1.1 L (4.40%)Admitted-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹25.8 L+₹1.1 L (4.40%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | - | - | Rejected-Technical not having c(ii) category |
| Sl No | Description | Qty | Unit | AISWARYA ENTERPRISES L1 | ELAN ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive maint and servicing of electrically operated passenger lift with a speed of 1.5Mtr/sec with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+9) of capacity 544 Kg 08 passengers ,with a speed of 1.5 M/sec to travel ground to nine upper floors with 10 stops and 10 landings
Gopal Bldg 01 No but 02 lifts (01 bldgs x 02 lifts= 02 Lifts for 10 months,ie,02 x10= 20 months) Make:Kone Elevators. | 20 | Per Month | 9,000 ₹1,80,000 Lowest | 9,500 ₹1,90,000 |
| 2.00 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+6) of capacity 544Kg 8 passengers ,with a speed of 1.5M tr/sec to travel ground to six upper floors with 7 stops and 7 landings
Bhishma building - 01 No at INS Dronacharya (01 bldgs x 01 lifts=1 Lifts for 10 months,ie,1x10=10 months). Make:Kone Elevators. | 10 | Per Month | 8,700 ₹87,000 Lowest | 9,000 ₹90,000 |
| 3.00 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+6) capacity 544 Kg 08 passengers,with a speed of 1.5Mtr/sec to travel ground to six upper floors with 7 stops and 7 landings
Mahanadi and Gandhari buildings - 02 Nos at INS Dronacharya (02 bldgs x 01 lifts=02 Lifts for 10 months,ie,2 x10=20 months) Make:Thyssenkrupp. | 20 | Per Month | 8,000 ₹1,60,000 Lowest | 8,200 ₹1,64,000 |
| 4.00 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+6) of capacity 884 KG 13 passengers with a speed of 1.5Mtr/sec to travel ground to six upper floors with 7 stops and 7 landings
Mahanadhi building at INS dronacharya (01 bldgs x 01 lifts=01 Lifts for 10 months,ie,01x10=10months) Make:Thyssenkrupp. | 10 | Per Month | 7,000 ₹70,000 Lowest | 7,200 ₹72,000 |
| 5.00 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
Goods lift for (G+6) of capacity 2000Kg Lift with a speed of 0.5M/sec to travel ground to six upper floors with 7 stops and 7 landings
Gandhari building at INS Dronacharya (01 bldgs x 01 lifts=1 Lifts for 10 months,ie,1x10=10 months) Make:Thyssenkrupp. | 10 | Per Month | 8,000 ₹80,000 Lowest | 8,200 ₹82,000 |
| 6.00 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusiveCleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+5) capacity 884 Kg 13 passengers, with a speed of 1.5M/sec to travel ground to five upper floors with 6 stops and 6 landings
Lathika building at INS Dronacharya (1 Lifts for 10 months,ie,1x10=10 months)
Make:Thyssenkrupp. | 10 | Per Month | 7,500 ₹75,000 Lowest | 7,700 ₹77,000 |
| 7.00 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive. Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+4) of capacity 544 Kg 08 passengers ,with a speed of 1.0M/sec to travel ground to Four upper floors with 5 stops and 5 landings
Ganga building (1 Lifts for 10 months,ie,1X10=10 months)
Make:Thyssenkrupp. | 10 | Per Month | 6,000 ₹60,000 Lowest | 6,300 ₹63,000 |
| 7.10Notes for Items Nos. 01 to 07: i) Major Spares required will be measured and paid seperately. ii) All other parts necessary for smooth operation of lift shall be deemed to be inclusive of quoted rates in comrehensive maintenance. iii) The contractor shall obtain complaints of lifts from Office and submit them duly signed within a week time duly rectified at no extra cost. iv) All parts installed shall be compatible in operation, fit and finish with the exisitng elevators. v) The spares shall be replaced only when found unservecieable at site and not for compatibility with brought incompatible spares and the contractor shall visit site and make sure the status of lifts installed at site. vi) All above maintenance/servicing/repair works have to be carried ourt through OEM Service agency only. vii) Periodical checking/servicing report shall have to submitted duly signed by the OEM. | |||||
| 8.00 | Supply only VVVF drive 415V 50 Hz 3 phase 11-18 kW suitable for passenger /goods lifts (suitable for Thyssenkrupp lifts) incl making necessary connections from controlers and ensure smooth operation including taking out old unserviceable VVVF drive complete all as specified and as directed. | 1 | Each | 1,10,000 ₹1,10,000 Lowest | 1,12,000 ₹1,12,000 |
| 9.00 | Supply only automatic rescue device single phase 1 kVA to 2.2 kVA complete assembly incl installation and commisioning as directed suitable for passenger /goods lifts incl taking out old unserviceable device complete all as specified and as directed. | 1 | Each | 90,000 ₹90,000 Lowest | 94,000 ₹94,000 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
2 Sept 2026, 6:00 pmClosed
CWE NB KOCHI
CWE (NB) KOCHI, Kataribagh, Naval Base PO, Kochi-04
COMPREHENSIVE MAINT/REPAIR OF GOODS/PASSENGER LIFTS AND PROVIDING TECHNICIANS AT INS DRONACHARYA UNDER GE FORT KOCHI
2026_MES_781860_1
81281
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
KOCHI
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹50,000
Yes
18 Sept 2026
31 Jul 2026
5 Sept 2026
31 Jul 2026
2 Sept 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive maint and servicing of electrically operated passenger lift with a speed of 1.5Mtr/sec with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+9) of capacity 544 Kg 08 passengers ,with a speed of 1.5 M/sec to travel ground to nine upper floors with 10 stops and 10 landings
Gopal Bldg 01 No but 02 lifts (01 bldgs x 02 lifts= 02 Lifts for 10 months,ie,02 x10= 20 months) Make:Kone Elevators. | 20 | Per Month | - | - |
| 2 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+6) of capacity 544Kg 8 passengers ,with a speed of 1.5M tr/sec to travel ground to six upper floors with 7 stops and 7 landings
Bhishma building - 01 No at INS Dronacharya (01 bldgs x 01 lifts=1 Lifts for 10 months,ie,1x10=10 months). Make:Kone Elevators. | 10 | Per Month | - | - |
| 3 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+6) capacity 544 Kg 08 passengers,with a speed of 1.5Mtr/sec to travel ground to six upper floors with 7 stops and 7 landings
Mahanadi and Gandhari buildings - 02 Nos at INS Dronacharya (02 bldgs x 01 lifts=02 Lifts for 10 months,ie,2 x10=20 months) Make:Thyssenkrupp. | 20 | Per Month | - | - |
| 4 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+6) of capacity 884 KG 13 passengers with a speed of 1.5Mtr/sec to travel ground to six upper floors with 7 stops and 7 landings
Mahanadhi building at INS dronacharya (01 bldgs x 01 lifts=01 Lifts for 10 months,ie,01x10=10months) Make:Thyssenkrupp. | 10 | Per Month | - | - |
| 5 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive.Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
Goods lift for (G+6) of capacity 2000Kg Lift with a speed of 0.5M/sec to travel ground to six upper floors with 7 stops and 7 landings
Gandhari building at INS Dronacharya (01 bldgs x 01 lifts=1 Lifts for 10 months,ie,1x10=10 months) Make:Thyssenkrupp. | 10 | Per Month | - | - |
| 6 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusiveCleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+5) capacity 884 Kg 13 passengers, with a speed of 1.5M/sec to travel ground to five upper floors with 6 stops and 6 landings
Lathika building at INS Dronacharya (1 Lifts for 10 months,ie,1x10=10 months)
Make:Thyssenkrupp. | 10 | Per Month | - | - |
| 7 | Comprehensive maint and servicing of electrically operated Elevator with AC VVVF drive and simplex collective ,selective control with AC variable voltage with thyrister drive. The lift's ARD system, emergency light, car lights and alarm, fireman switch, digital floor position indicator in car and in all landing, including replacement of minor defective and unserviceable parts such as push buttons/ light fittings/bulbs/ connectors, wires, lubricants, during contract period are inclusive. Cleaning of machine room ,pit, car top/cabin regularly & attending to breakdown as and when intimated in three hours notice including necessary periodical safety checking and testing of lift as mentioned in relevant code practices/ IE for the safe and efficient performance of lifts of description/capacity-
(G+4) of capacity 544 Kg 08 passengers ,with a speed of 1.0M/sec to travel ground to Four upper floors with 5 stops and 5 landings
Ganga building (1 Lifts for 10 months,ie,1X10=10 months)
Make:Thyssenkrupp. | 10 | Per Month | - | - |
| 8 | Supply only VVVF drive 415V 50 Hz 3 phase 11-18 kW suitable for passenger /goods lifts (suitable for Thyssenkrupp lifts) incl making necessary connections from controlers and ensure smooth operation including taking out old unserviceable VVVF drive complete all as specified and as directed. | 1 | Each | - | - |
| 9 | Supply only automatic rescue device single phase 1 kVA to 2.2 kVA complete assembly incl installation and commisioning as directed suitable for passenger /goods lifts incl taking out old unserviceable device complete all as specified and as directed. | 1 | Each | - | - |
| 10 | Supply only UPS unit not less than 1600 VA 230 V single phase suitable for upto 65 Ah SMF batteries incl making connection to ARD and cabin light and fan incl taking out old unserviceable UPS unit complete all as specified and as directed. | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
TENDER81281.pdf
Tender Documents • 0.80 MB
BOQ_875876.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .