Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 CrAccepted-AOC K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹16.6 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹17.6 CrRejected-Finance BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹17.6 Cr | L2 | Rejected-Finance being not lowest |
| 3 | L3₹25.0 CrRejected-Finance | ₹25.0 Cr | L3 | Rejected-Finance being not lowest |
| Sl No | Description | Qty | Unit | Hariom Projects Pvt Ltd L3 | Brahma Infra L2 | SOOD ASSOCIATES PVT LTD L1 |
|---|---|---|---|---|---|---|
| 1.00NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 2.00 to 15.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | ||||||
| 2.00 | Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I 'B'. | 1 | Lumpsum | 51,00,000 ₹51 L | 45,00,000 ₹45 L | 99,28,098 ₹99.3 L |
| 3.00 | Lump sum price worked out for Excavation/ Earth Work & Site Clearance as listed in Sch `A’ Part II | 1 | Lumpsum | 75,00,000 ₹75 L | 55,00,000 ₹55 L | 59,38,913.12 ₹59.4 L |
| 4.00 | Lump sum price worked out for Internal Water Supply as listed inSch `A’ Part III | 1 | Lumpsum | 35,000 ₹35,000 | 45,000 ₹45,000 | 61,835.84 ₹61,835.84 |
| 5.00 | Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV. | 1 | Lumpsum | 11,00,000 ₹11 L | 10,00,000 ₹10 L | 9,38,592.95 ₹9.4 L |
| 6.00 | Lump sum price worked out for Road, as listed in Sch `A’ Part V. | 1 | Lumpsum | 51,00,000 ₹51 L | 50,00,000 ₹50 L | 49,39,695.41 ₹49.4 L |
| 7.00 | Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI. | 1 | Lumpsum | 3,50,000 ₹3.5 L | 4,00,000 ₹4 L | 4,70,963.55 ₹4.7 L |
| 8.00 | Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VII. | 1 | Lumpsum | 20,00,000 ₹20 L | 20,00,000 ₹20 L | 22,44,568.53 ₹22.4 L |
| 9.00 | Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VIII | 1 | Lumpsum | 18,00,000 ₹18 L | 20,00,000 ₹20 L | 19,09,089.96 ₹19.1 L |
| 10.00 | Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part IX | 1 | Lumpsum | 51,00,000 ₹51 L | 50,00,000 ₹50 L | 52,67,870.69 ₹52.7 L |
Updated dates
Tender Value
₹15.6 Cr
EMD Value
₹11.1 L
Closing Date
3 Apr 2026, 6:00 pmClosed
CE (AF) Gandhinagar
CE (AF) Gandhinagar Lekawada Patia, Chiloda P.O. CRPF Campus Gandhinagar-382 042
PROVISION OF INCOMPLETE WORK OF HANGAR FOR AIRCRAFT AND GROUND EQUIPMENT AT HARNI AIR FIELD AT AFS VADODARA
2026_MES_752348_1
89342/ROC
Open Tender
Civil Works
550 days
GE (AF) BARODA
AS PER NIT AND TENDER DOCUMENT
6 documents required · 6 mandatory
₹3,000
GE (AF) BARODA
₹11.1 L
Yes
22 Apr 2026
11 Feb 2026
6 Apr 2026
11 Feb 2026
3 Apr 2026
20 Mar 2026
16 Feb 2026 - 20 Feb 2026
NOTE: Schedule ‘A’ Part I to XIV are under Ser No. 2.00 to 15.00. are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I 'B'.
Lump sum price worked out for Excavation/ Earth Work & Site Clearance as listed in Sch `A’ Part II
Lump sum price worked out for Internal Water Supply as listed inSch `A’ Part III
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part IV.
Lump sum price worked out for Road, as listed in Sch `A’ Part V.
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VI.
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VII.
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part VIII
Lump sum price worked out for External Electric Supply as listed in Sch `A’ Part IX
Lump sum price worked out for Lightening Protection as listed in Sch `A’ Part X
Lump sum price worked out for DG Set as listed in Sch `A’ Part XI
Lump sum price worked out for Summer Appliance & Air Conditioning as listed in Sch `A’ Part XII
Lump sum price worked out for Fire Fighting as listed in Sch `A’ Part XIII
Lump sum price worked out for Hot Water Supply as listed in Sch `A’ Part XIV
SCHEDULE `A' PART - IA (TO BE QUOTED BY THE CONTRACTOR)
PEB HANGER
Provn of INCOMPLETE HANGER size 70mx(l)x45m(w)x11m(h) complete (roofing, cladding & foundation) (a) PEB steel supper structure (b) RCC foundation (c) Rigid pavement flooring as per drg attached including one meter beyond all round hanger (d) Galvalume sheet 0.60 mm thick of approved profile with camouflage pattern colours (e) Eletrically operated motorized door with provision for manual operation with trolly mounted portable electrically operation winch (two numbers) (including desugning and comissioning of complete door and its mechanical and electrical system with all necessary safety provision & wiring upto LT panels .LTpanels shall be measured and paid seperately) (f) Bird proofing with PVC netting (g) EPU overlay of 5 mm thick high density EPU flooring system above complete rigid pavement flooring (h) Turbo type ventilators - 04 Nos on each sides Note:- As per Item No 1 of Sch 'A' Part I (A) on Srl Page No 25
SCHEDULE `A' PART - XV (MISC ITEMS) Fittings & fixtures is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
INTERNAL ELECTRIFICATION
Supply & fix ceiling fan 1200mm sweep and connecting up to and including provision of 23/0.0076 (or equivalent size in mm) flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc complete all as specified and as directed.
Supply and fix Exhaust fan 300mm sweep 240 V AC metal body fixed as per maufacturers instruction, connecting with and including 1.5 Sqmm copper coduct PVC insulated and PVC sheathed three core cable complete all as specified and as directed.
Supply & fix decorative box type fitting suitable for tetro LED tube rod of 20 watt having decorative END caps for ensuring asthetic looks and should be prewired for LED tube. The LED tube itself should have minimum 2100 lumens output power factor>0.9 and THD=<15% rated CCT 6000 K Cat REF-LRT8-20-C complete all as specified and as directed.
Supply & fix LED GLO bulb of 3 watt having asthetic looks and should be prewired for LED bulb including all fitting and fixtures, holders etc complete all as specified and as directed.Model name and No-LED GLO 3W, HPLDECBB001B22
Supply & fix LED security light luminaire 1x22W having IP-65 protection, with minimum system efficiency as> 85%,made of pressure die cast housing toughned glass in the front and peanut lens for batwing light distribution with excellent thermal manegement. The fitting should have rate CCT 5000K complete with all accessories and complete all as specified and as directed.Make:-Oreint cat ref LSFS-022-C or equivalent
Supply & fix highbay luminaire 180 W CCT 6000K with high efficiency, designed with exellent thermally managed alluminium die housing, having heat dissipating fins for larger surface area, satin finish powder coated in grey and fitted with poly carbonate clear diffuser in the front for the desired ingress protection, with totally enclosured IP-65 complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size etc complete all as specified and as directed.Make:- Orient pinnacle Cat No LHPN-180-C(1.00) or equivalent in Philips, GE
Supply & fix MCB triple pole & neutral 415 Volt C curve 10 KA, 63 Amps capavity IP-20 etc complete all as specified and as directed.
Supply & fix MCB single pole & neutral 415 Volt C curve 10 KA, 32 to 40 Amps capavity IP-20 etc complete all as specified and as directed.
Supply & fix MCB single pole 240 Volt B curve 10 KA, 5 to 30 Amps capavity IP-20 etc complete all as specified and as directed.
Supply & fix MCB (DB) TPN, 415 Volts 04 way vertical double door type powder coated sheet steel enclosure with following. (a) Isolator TPN 100 Amp -01 No (b) MCB SPN 40 Amps-03 Nos etc complete all as specified and as directed.
Supply & fix MCB (DB) SPN, 240 Volts 08 way horizontal double door type powder coated sheet steel enclosure with following. (a) MCB SPN 32 Amp-01 No (b) MCB SP 16 Amp-02 Nos (c) MCB SP 6 Amp-04 Nos etc complete all as specified and as directed.
Supply & fix MCB (DB) SPN, 240 Volts 04 way horizontal double door type powder coated sheet steel enclosure with following. (a) MCB SPN 32 Amp-01 No (b) MCB SP 6 Amp-02 Nos etc complete all as specified and as directed.
ROAD, PATH/HARD STANDING & CULVERT
Material & labour for 2 mm thick centr line stop line dahes arrows brackets and similar work on road surface as per IRC pattern with thermoplastic approved quality pf plant make with 8% glass beads laid at temp 160 with a special applicator machine complete all as per instructions and complete all as specified and as directed.
Material & labour for WMM(wet mixed macadum) 150 mm thick in two layers of each 75 mm thick ( Compacted thickness ) with coarse aggregate of granite trap or basalt(90 to 40 mm size) stone of grading II as per spread with mechanical paver,(with sensor minimum 9m wide) rolled and consolidated to gradient and camber required all as specified in SSR Pt-I 2009 clause 20 B 5 page No. 553 . ( Note:- WMM shall be carried out in two layer of 100 mm thick each layer compacted and seperately spread and rolled .) complete all as specified and as directed.
Material & labour for Dry Lean Concrete ( DLC) of Thickness 150 mm having minimum 7 days crushing strength of 10 N/mm2 over a prepared subgrade with coarse and fine aggregate conforming to IS: 383, Size of aggregate not exc 40mm (grading and other parameters as per table 600-1 of MORTH, IRC SP : 49 specification), of design mix, minimum cement content should be 240 kg/cum as per IS 456.mixed in batching plant, trasported to site laid with sensor paver including spreading and compated by using 8 to 10 tonnes vibratory roller including necessary formwork finishing etc complete all as specified and as directed.(Note:- Trial bay shall be carried out at site. The rate is inclusive of this provision)
Material & labour for 400 micron polythene film transparent (non recycled) laid over screened sand filling with side and end overlapping not less than 300mm complete all as per IS 2508. complete all as specified and directed.
Material & labour for 200 mm thick RMC in Pavement Quality Concrete (PQC) of minimum field flexural strength 45 Kg/Sq cm(lower control limit-LCL) after 28 days in pavement slab using 400 kg of cement per cum and using non circular fibre synthetic reinforcement @ 0.15% by weight of cement with crushed stone aggregate of grading as specified laid in panels,including necessary formwork, spread and compacted using mechanical paver, mechanically vibrated & bull nosing/rounding off edges, curing, broom finishing on top, belting, etc complete all as specified and as directed (Thickness of concrete shall be 200 mm)
(iv) Deduction shall be made in computing concrete quantity for expansion joints. (v) No price adjustment shall be applicable if excess quantity of cement content is used/approved in the execution of work under this item. However minus price adjustment shall be made for less quantity of cement used in the work based on inserted rate against.
Supply only super plasticizer, etc complete all as specified and as directed
Supply only polyester triangular synthetic fibres 6/12mm long with circum circle diameter 30-35 micron desgined for melting point 240 -260 celsius having specific gravity 1.34 to 1.4 Recron 3S manufactured by M/s Reliance Industries Ltd Mumbai or M/s Finolex Industires Ltd or equivalent as secondary reinfocement in all type of concrete @0.25% by wt of cement complete all as specified and directed
Material and labour for forming 25mm thick expansion joints for 200mm thick PQC filled with preformed filler board conforming to IS:1838:2011 Part- 3, provision of closed cell polyethylene backup rod 30mm dia, sealed with pitch free polyurethane grey sealant (Minimum depth of sealant above back up rod shall be 15mm ) confirming to BS -5212 type FB priming the sides as recommended in manufacturer's instructions and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied
The sealant should have MAF (+/-) 30% and manufacturer's warranty for 10 years as used in international Airport in India complete all as specified and as directed by Engr-in-Charge and as shown on drawings.(for flexural concrete) etc including rounding of the edges of expansion joint. complete all as specified and as directed.
Material and labour for forming construction joints 28 mm deep x 10 mm wide (using diamond cutter) within 6 days of completion of curing provision of closed cell polyethylene back up rod 12 mm dia, provision of de-bonding strip of minimum 5 mm thick and sealed with pitch free polyurethane grey sealant conforming to BS-5212 (Type-FB) priming the sides as per manufacturer’s instructions and applying masking tape on edges of joint to prevent accidental spillage of sealant on top surfaces and to give a neat finish to the sealant and removing the masking tape after sealant applied complete.
(Note :- Before laying the adjacent slab, white washing/bituminous paint to the already casted concrete is to be carried out. The unit rate is inclusive of this provision),joint sealant with MAF (+/-) 30% and 10 yrs performance warranty as used in International Air Port in India all as specified and as directed and shown on drawings. complete all as specified and as directed.
Material and labour for forming contraction (Dummy) joints 70mm deep x 6 to 8mm wide for 200mm thick PQC (using diamond cutter) as soon as the concrete is strong enough to with stand edge spalling i.e. first cut as early as possible but not later than 24 hrs and filled with expanded polyurethene foam (armour board), applying bond breaker tape on top of armour board for complete width of joint including provision of closed cell polyurethene backup rod 10mm dia and sealed with pitch free polyurethane grey sealant (Min depth of sealant above back up rod shall be 16mm) confirming to BS -5212 type FB priming the sides as recommended in manufacturer's instructions and applying masking tape on edges of joint to
prevent accidental spillage of sealant and removing the masking tape after sealant is applied. confirming to BS -5212 type FB priming the sides as recommended in manufacturer's instructions and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied. The sealant should have MAF (+/-) 30% and manufacturers warranty for 10 years as used in international air port in India all as specified and as directed by Engineer-in-Charge and as shown on drawings.(Polyurethane joint sealant shall be used).
Note for Item No.33 to 38: - Joints in existing rigid pavement shall be mapped before commencement of work and joints in top layer being overlaid shall be matched as far as possible.
Preparing new concrete/bituminous surfaces and painting lines, dashes (continuous/un-interrupted), arrows, letters, etc exceeding 10 cm width with two coats of waterbased road marking paint in white,golden,yellow or red colour over a coat of primer complete all using road painting machine all as directed. Paint and primer shall be of Asian/Shalimar/Berger/J&N/Nerolac make. complete all as specified and as directed.
Providing Broom finished surface of concrete pavement while concrete is green with mechanical broom all complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Material and labour for construction of for Valve Pit /Chamber in PCC solid block masonry (1:5:8) built in CM 1:6 ,over 150 mm thick PCC foundation 1:3:6 type C2, 10mm thick internal CM 1:6 & 12mm thick external plaster in CM 1:4 provided with 3 mm thick MS sheet cover and MS angle iron chamber frame fixed in coping in PCC 1:2:4 type B-1 with locking arrangement etc suitable for 80 mm dia sluice valve and handle, painting of MS work with one coat of red oxide primer and two coat of synthetic enamel black paint complete including excavation & earth work in any type of strata complete all as shown on drawing No.CEAA/TD/57sheet No 1.1,dated 28.05.92,amended upto 31.12.92, but of internal size 900mm(L) x 600mm(B) x 1000mm (D) etc complete all as specified and directed. Note : Excavation Retuning filling is including in the item
Material and labour for construction of for Valve Pit /Chamber in PCC solid block masonry (1:5:8) built in CM 1:6 ,over 150 mm thick PCC foundation 1:3:6 type C2, 10mm thick internal CM 1:6 & 12mm thick external plaster in CM 1:4 provided with 3 mm thick MS sheet cover and MS angle iron chamber frame fixed in coping in PCC 1:2:4 type B-1 with locking arrangement etc suitable for gate valve or 50 mm dia sluice valve and handle, painting of MS work with one coat of red oxide primer and two coat of synthetic enamel black paint complete including excavation & earth work in any type of strata complete all as shown on drawing No.CEAA/TD/57sheet No 1.1,dated 28.05.92,amended upto 31.12.92, but of internal size 450mm(L) x 450mm(B) x 600mm (D) etc complete all as specified and directed. Note : Excavation Retuning filling is including in the item
Material and labour for direct cylinder mounted type vaccum chlorinator for gavity feed including all gauges pump motor confirming to IS 10553 part 2 having capacity 1.0 to 1000 gm/hr etc complete all as specified and directed.
Supply, install, test and commissioning of manufacture's factory assembled and tested electric driven centrifugal pump set of capable of delivering 5 LPS at 27 Meter head comprising of horizontal spit casing pump multi stage CI body with impellers operating at 1440/1450 RPM coupled through a flexible coupling to a SPDP motor 1440/1450 RPM not less than 5 HP complete with starter and mounted on common MS base frame and foundations of the pump set including PCC foundation, MS bolts with nuts and vibration pads. The work also includes the following. (a) Pump set capable of delivering 5 liters per second at 27 Meters head coupled with electric driven motor of suitable size Model 1331+ of Kirloskar Brother make or equivalent of mother & Plant/KSB/
(b) Provn of suitable fully automatic starter complete with under voltage and overload protection , single phase preventer and mounting in main electric panel (Electric panel to be paid for separately) and also including necessary wiring with PVC insulated and unsheathed copper conductor cable multistranded of suitable size , concealed in light grade GI or flexible pipe complete all as specified and directed. (c) Vacuum gauge -01 No (d) Pressure gauge diaphragm type up to 50 Kg/Cm2-1 No
Supply & fix cost for MS reducer, bail plug, well cap, etc strip for centring, MS iron clamps, electric logging and simple strata box complete all as specified and directed.
Supply & fix trial bore of 200 mm dia up to 200 mtr depth below ground level in any kind of soil strata including hard stone/ boulder including electric logging, MS cap, MS flat iron clamps, reducing socket etc complete all as specified and directed.
Supply & fix trial bore of 200mm dia exceeding 200 mtr depth below ground llevel and up to 400 RM in any kind of soil strata including hard stone/boulder etc complete all as specified and directed.
Development of trial bore by reaming in following step:- (a) From 200mm to 350 mm (b) Reaming up to 525mm for from ground level including casing pipe of 200mm dia and thickness 8 mm and pea gravel tc complete all as specified and directed.
Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water etc complete all as specified and directed.
Supply & fix Yield test for bore well by continuosly pumping for 16 hours to Each job determine safe pumping yield etc complete all as specified and directed.
Supply and fixing Submersible pump electrical driven 415 V TP suitable for 200mm dia bore well complete upto 500 LPM at 45 Meter head including of 40 meter long submersible copper cable and starter etc complete all as specified and directed.
EXTERNALELECTRIFICATION
Supply installed testing and commissioning of LT outdoor cubical type panel board fabricated on 50x50x6mm thick angle iron frame with 16 gauge MS sheet cover with following accessories :- (i) Alluminium bus bar 400 Amps capacity -04 Nos (ii) MCCB 4 pole 440 volts 35 KA 3 phase, capacity 200 Amps-01 No (iii) MCCB 3 pole 440 volts 35 KA 3 phase, capacity 160 Amps -01 No (for PF Pactor) (iv) MCCB 4 pole 440 volts 16 KA, 3 phase, 4 wire capacity 200 Amps -01 No (for hanger) (v) Digital Multi-function meter pressure voltage, current frequency power factor (digital type) 0-300 Amps - 01 No
Supply installed testing and commissioning of LT indoor cubical type panel board fabricated on 50x50x6mm thick angle iron frame with 2 mm sheet cover with following accessories :- (i) Alluminium bus bar 250 Amps capacity -04 Nos (ii) MCCB 4 pole 440 volts 25 KA 3 phase, 4 wire capacity 200 Amps -01 No (iii) MCCB 3 Pole 63 Amps - 03 Nos (iv) MCB TP 40 Amps -05 Nos (v) MCB SPN 20 Amps -01 No (vi) Digital Multi- Function meter pressure voltage, Current frequency power factor (digital type) -01 No
Supply & fix FRP pole mounting box wether proof type of size 270mmx170mmx90mm with three terminal and one 6 Amps MCB mounted inside complete all as specified and directed. Make: Sintex/National/Standard.
Supply & fix aesthetically designed LED security light luminiareis of 22 Watts system wattage for energy saving IP-66 degree of protection , with min system efficiency as>85%, made of pressure die casting aluminium housing power coated in graphite grey and heat resistant toughened glass with excellent thermal management LED shold have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 120-270 VAC, THD<10%, P.F.>.95. The fitting should have built surge protector of 5 KV and CRI>70 with CCT 5700K complete all as specified and directed.
Supply and fix street light box of PVC make sintex consisting of 01 No MCB 10 Amps, 10 KA capacity (3 phase and neutral) including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp as approved and complete all as specified and directed.
Supplying of Asthetically designed LED flood luminaries of 100 watts system wattage for energy saving IP- 65 degree of protection with minimum system lumens as 18000 made of pressure die cast aluminium housing powder coated and heat resistant thoughned glass with firns for thermal dissipation LED should be fitted on MCPCB and provision of cradele/ Clamp sholud be there in fixture for mounting purpose fitting should have THD less than 10% P.F. more than 70 with CCT 5700 k Isfo-200 cdl/60 complete all as specified and directed.
Supply and fix cable XLPE Insulated screened PVC bedded, armoured, copper cable 16 Sqmm 4 core electric power cables (heavy duty)1100 Volts grade with multi stranded Copper conductor from rectified to DB complete all as specified and directed.
Supply and laying unreinforced precast cable cover, Class HV type 2 flat size 300mmx180mmx40mm complete all as specified and directed.
FIRE FIGHTING
Supply & fix cast iron valves with single air outlet conforming to IS-14845 of size 150 mm dia bore and fixing up in MS pipe of size 150 mm dia etc complete all as specified and directed.
Supply & fix cast fire hydrant stand post with provn of single outlet conforming to IS 908 etc complete all as specified and directed.
Supply & fix cast fire hose 2.5mm"x30m male & female with brass coupling complete ISO certified in existing fire hose cabin etc complete all as specified and directed.
Material and labour for construction of for Valve Pit /Chamber in PCC solid block masonry (1:5:8) built in CM 1:6 ,over 150 mm thick PCC foundation 1:3:6 type C2, 10mm thick internal CM 1:6 & 12mm thick external plaster in CM 1:4 provided with 3 mm thick MS sheet cover and MS angle iron chamber frame fixed in coping in PCC 1:2:4 type B-1 with locking arrangement etc suitable for 150 mm dia sluice valve and handle, painting of MS work with one coat of red oxide primer and two coat of synthetic enamel black paint complete including excavation & earth work in any type of strata complete all as shown on drawing No.CEAA/TD/57sheet No 1.1,dated 28.05.92,amended upto 31.12.92, but of internal size 900mm(L) x 600mm(B) x 1000mm (D) etc complete all as specified and directed. Note : Excavation Retuning filling is including in the item
Supply and install, testing and commissioning LT panel indoor type floor mounted factory made totally enclosed dust and vermin proof double shutters (front and rear opening with locking arrangement ) made of MS angle iron frame 40x40x6mm and 2mm thick MS sheet cover paint with two coats of synthetic enamel paint over a coat of red oxide primer sutaible for three phase 4 wire 440 volts consisting of following items for centrifugal pump sets. (a) Copper bus bar chamber 3 phase and netural 200 Amps cap - 04 Nos (b) MCCB 4P 415 Volt 63 Amps, 25 KA -01 No (c) MCCB TPN 415 Volts 40 AMPS -02 Nos (d) Multi function digital type energy meter, including voltage, current, frequency-01 No (e) Provision for fully automatic star delta starter suitable for 20 HP electric Motor including wiring with suitable gauge copper conductor in the panel and testing complete-03 Nos (f) All necessary connection made with suitable size copper cable and lugs (g) Neon indicating lamp set of 3 - 01 Nos etc complete all as specified and directed.
Supply only mechanical foam based fire extinguishers type store pressure capacity 9 ltrs fire rating 3A 34B working pressure 55/80 bar min, 100 bar actual etc complete all as specified and directed.
Supply only dry chemical powder stored pressure type fire extinguisher Ggade IS 15683 capacity 6 kg etc complete all as specified and directed.
Supply mechinical foam 50 ltrs gas catridge trolley fire extinguisher type trolly mounted media mechanical foam capacity 50 ltrs, effective discharge 90% min jet length 10 min discharge time 40 sec to 180 sec etc complete all as specified and directed.
Supply wheeled/trolly mounted CO2 extinguisher IS 1601822.5 Kg etc complete all as specified and directed.
Supply & fixing rigid non metallic PVC conduots inclusive of boxes (junction/terminals) and inclusive of all tees, bends elbows, reducers bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles pipe hooks etc of external dia 25 mm etc complete all as specified and directed.
Supply and drawing of PVC insulated FRLS single core as per PS conductor copper wire into the existing, conduit of the following sizes. ISI marked cable. Make-National/Polycab/Finolex/Havells
(a) 2x1.5 Sqmm
(b) 2x6.0 Sqmm
COOLING APPLIANCES
Supply and install wall mounted of voltage stabilizer for automatic operation single phase natirally air cooled indoor type & designed for input variation between 180 V to 250 V +/- 2.5% with output voltage stablized at 230 V of capacity 5 KVA complete on wall and making necessary electric connection with AC unit complete all as specified and directed.
Supply and install wall mounted of voltage stabilizer for automatic operation single phase natirally air cooled indoor type & designed for input variation between 180 V to 250 V +/- 2.5% with output voltage stablized at 230 V of capacity 4 KVA complete on wall and making necessary electric connection with AC unit complete all as specified and directed.
Supply only reverse osmosis water treatment plant is designed to produce product water at the flow rate of 100 LPH based on reverse osmosis technology complete all as specified and directed.
Supply and installed refrigerators electric driven single phase of capacity 310 Ltrs frost free double door complete all as specified and directed.
Supply and fix desert cooler electric driven nominal air flow capacity of 4000 CFM complete all as specified and directed.
Supply and install wall mounted of voltage stabilizer for automatic operation single phase natirally air cooled indoor type & designed for input variation between 180 V to 250 V +/- 2.5% with output voltage stablized at 230 V of capacity 2 KVA complete on wall and making necessary electric connection with AC unit complete all as specified and directed.
Supply and install wall mounted of voltage stabilizer for automatic operation single phase natirally air cooled indoor type & designed for input variation between 180 V to 250 V +/- 2.5% with output voltage stablized at 230 V of capacity 1 KVA complete on wall and making necessary electric connection with AC unit complete all as specified and directed.
DG SET
Supply erecting . Testing and commissioning complete of manufacture of OEM manufactureed static (silent sound enclosure). Diesel engine driven Generating set capable of delivery 125 KVA (With AMF Panel suitiable raitng of contactor) water cooled 415 Volt (AC three phase 4 wire system of supply ) 50 HZ at power factor 0.8 minimum The DG set shall consists of diesel engine coupled to a matching alternator through flexible coupling and mounted on common base frame and complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet outlet return inlet oil arrangment exhaust pipe complete and suitable for condition prevalent at Baroda (capacity of engine alternator shall be worked out taking all derating factor into consideration ) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height ) anti vibration pads including all features to coply with latest CPCB guidelines and comprising of following.
(i) Engine prime Mover) : - Diesel Engine 1500 RPM direct six cylinder four stroke confirming to ISO 3046/BS water cooled naturally turbo charged capable of giving adequate BHP to drive Alternator capable of delivering 125 KVA at outdoor atmosperic condition at jalipa (taking all derating factor in to consideration ) 12/24 Volt (as per manufacturer recommendation ) electric battery start complete with fly wheel all standard fitting/fixure as per manufacturer and including suitable panel with tachometer lub oil temprature (ii) ATERNATOR: brushless AC alternator 3 phase 415 Volt 4 wire rated for output of 125 KVA Minimum power factor 0.8, 1500 RPM IP-23 Protection class enclosure insulation class H salient pole revolving field single bearing automatic revolving field single bearing automatic voltage regulator coupled throgh flexible coupling with and to match the above engine.
(h) ACOUSTIC ENCLOSURE : Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 m at 75% load under field condition and ox 70 DB at 3 m from Gen set is working at full load alonwith when DG set is working at full load alongwith testing confirmance lebeling certification etc as laid down in GSR (vi) FOUNDATION/PLINTH/BASE:- Shall be provided as per manufacture's however minimum 0.5 m space shoukd be available all round the set and height of plinth shall be not less than 0.5 m (vii) Diesel storage tank of capacity adequate for storage of diesel for 12 hour operation of Gen set (viii) Secondary maintenance free for battery of suitable capacity for above DG set duly initially charged. (ix) MISC:- Tool kit operation and maintenance catalgue spare part list overlaning manuals guarantee card etc shall be provided as per manufacturer standard practice
MOTORISATI ON OF HANGER DOOR
Material & labour for feeder (kiosk) of size not less than L=60 CMX45 CM(H) made out 20 m thick out door type CPRI approved with operation front door including locking arrangement with copper busbar 200 Amps rating and fixed on angle iron frame and PCC plinght complete all as specified and as directed.
Material & labour for Earthing of machinery equipment installed at power house/ sub station complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm as earthing lead burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead wire 4 mm dia by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation/earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber,
precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, upto 7.5m lenght test point etc. complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. Any addition in length shall be adjusted through deviation order.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.17 MB
89342ROC.rar
Tender Documents • 7.23 MB
Drg.rar
Additional Documents • 10.51 MB
BOQ_842662.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid