Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC AOC amt is derived after deduction amt of sch of credit and revised offer | |
| 2 | L2₹13.4 L+₹3.0 L (28.5%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹13.7 L+₹3.3 L (31.6%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹16.8 L+₹6.4 L (61.3%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹19.1 L+₹8.6 L (82.4%)Rejected-Finance BIAMATHANG BAROO KARGIL J K | KARGIL | KARGIL | J K | L5 | Rejected-Finance Other than L1 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
14 May 2020, 6:00 pmClosed
GE Kargil
GE Kargil
SPL REPAIR TO EXTERNAL LT DISTRIBUTION SYSTEM IN 114 MED REGT AND REPLACEMENT OF OLD UNSV CFL STREET LIGHT/ SECURITY LIGHT FITTINGS WITH SMART LED FITTING AT VARIOUS UNIT AT GE KARGIL
2020_MES_340783_1
GE/K-07/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kargil
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Kargil
₹46,000
Yes
26 May 2020
25 Apr 2020
16 May 2020
25 Apr 2020
14 May 2020
8 May 2020
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soil.
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc.1.50 mtr above the starting point.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I,complete all as specified and directed by the Engr-in-Charge.
S&F un-reinforced precast cement concrete cable cover of PCC 1:1.5:3 type A-1, conforming to class LV, flat of size 250mmx150mmx40mm factory made, laid dry over electric cable for protection
S&F Synthetic insulating mat of size 2000x1000 mm and 19mm thick, complete all as specified and directed by Engr-in-Charge.
S&F, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3.5 core, complete all as specified and directed by Engr-in-Charge.
All as per above item but cable cross sectional area 95 Sqmm 3.5 core
Supply , installation, connect test and commission factory made, cubical type outdoor vermin, dust proof LT distribution panel made out of 3.5 mm thick CRCA steel sheet and angle 40x40x5mm front and rear opening cubical shutter with locking arrangements duly tested and powder coated of suitable size with & including following accessories and components:-
Supply , installation, connect test and commission factory made, cubical type outdoor vermin, dust proof LT distribution panel made out of 3.5 mm thick CRCA steel sheet and angle 40x40x5mm front and rear opening cubical shutter with locking arrangements duly tested and powder coated of suitable size with & including following accessories and components:-
Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connecting to the galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of GI and steel earth wire protected by provision of GI medium grade pipe 15mm bore including provision of concrete pit made from PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in pit, angle iron 25x25x6mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade, salt, charcoal, etc. including excavation and earth work in any type of soil, removal of surplus spoil to a distance not exc. 50m complete all as shown in electrical plate No.3 of MES Schedule 2009 (Pt-I) and connected to earth test point all as specified including testing on completion.
S&F, 36 watt (IP-65) LED street light fittings pressure die cast aluminium housing comprising of epoxy powder coated enclosed with glass cover with all accessories complete Make/Model : Philips BRP052 LED036CW HP SLAFG S1 PSUGR or equivalent in approved make, complete all as specified. and directed by Engr-in-Charge.
S&F, 72 watt (IP-65) LED street light fittings pressure die cast aluminium housing comprising of epoxy powder coated enclosed with glass cover with all accessories complete Make/Model : Philips BRP410 LED CW072 NR FG S1 PSUGR or equivalent in approved make, complete all as specified. and directed by Engr-in-Charge.
S&F Street light bracket made out of GI pipe 35mm dia light grade 1.2 mtr duly bended in position as per site requirement and including 2 Nos and 2 set MS flat iron clamps of suitable size complete with 03 set nut , bolts and washers for mounting street lights, complete all as specified. and directed by Engr-in-Charge.
Cable junction box of size not more than 250x150x75 mm with 6 Amp MCB SPN and bus bar fixed along the wall/pole without removing and preparation of surfaces for painting externally. Painting the cable junction box complete externally by applying one coat of synthetic enamel paint of approved colour, complete all as specified. and directed by Engr-in-Charge.
Supply and laying or fixing non metalic PVC conduit pipe of 20 mm dia with all accessories such as tee, bend, elbow, reducer, bell mouth etc complete all as specified. and directed by Engr-in-Charge.
S&F or passing through pipe 1100 volts grade heavy duty cable PVC insulated aluminium stranded coductor, served with inner sheathed PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 4 sqmm cross sectional area twin core as in service connection
S&F or passing through pipe 1100 volts grade heavy duty cable PVC insulated aluminium stranded coductor, served with inner sheathed PVC tape armoured with galvanised steel wire or tape and over all PVC sheathed 10 sqmm cross sectional area twin core as in service connection
Deduction Rs 15935.00 for Schedule of credit as given in Sch A Part-II
M/S TRADE LINK
osho traders
national engineering
M/S MOHD KHAN
M/S MOHD ALI
Hitech Erectors Pvt. Ltd.
M/S HAJI HASSAN ENGINEERING WORKS
M/S SUN RISE BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .