Renovation and Upgradation of Sound System and Stage Lighting System overhauling of HVAC system and replacement of the lights at the Utsav auditorium at Cooch behar Town in the District of Cooch behar.
2026_NBDD_1042290_1
NBDD/BS/EE /NIT/NIQ -30 (EL) of 2026-2027
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Cooch Behar
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.8 L
Yes
16 Sept 2026
16 Sept 2026
7 Oct 2026
16 Sept 2026
5 Oct 2026
16 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C | 20 | Point | - | - |
| 2 | LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) 18 watt Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim(Make Panasonic/Havells/Orient Electric/Halonix/Jaguar/Philips as per the choice of EIC). Submission of test report and warranty certificate for atleast two years is mandatory from OEM. | 50 | Set | - | - |
| 3 | Supplying and fixing following way, single pole andneutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)12 way , Double door | 1 | Set | - | - |
| 4 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable forinductive load of following poles in the existing MCBDB complete with connections, testing andcommissioning etc. as required.
32 Amp. DP MCB. | 2 | Each | - | - |
| 5 | (6-32)Amp. SP MCB. | 12 | Each | - | - |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover ( Make: Legrand Nextgen /Schneider/Siemens as per the choice of EIC)in front on surface or in recess,
including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. | 6 | Each | - | - |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover( Make: Legrand Nextgen /Schneider/Siemens as per the choice of EIC)in front on surface or in recess,
including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 6 | Each | - | - |
| 8 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire | 20 | Mtr. | - | - |
| 9 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 80 | mtr. | - | - |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle) | 150 | Mtrs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
Tendernotice_2.pdf
PDF • 0.72 MB
BOQ_2558349.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .