Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 19 1 69 3 PLOT NO 17 NEW ADARSH COLONY BIDAR 585 401 | BIDAR | KARNATAKA | 585401 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹25.7 L
EMD Value
₹51,400
Closing Date
16 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BIDAR
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
PROVISION OF CERTAIN B/R MAJOR REVENUE / MINOR WORKS AT AFS STN BIDAR.
2021_MES_476226_1
8108/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF BIDAR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF BIDAR
₹51,400
Yes
1 Nov 2021
18 Sept 2021
18 Oct 2021
18 Sept 2021
16 Oct 2021
2 Oct 2021
60 days
Amount
Excavation over area not exceeding 1.5m deep and getting out in soft / disintegrated rock complete all as specified and as directed.
All as per item No. 1 hereinbefore but depth exceeding 1.5m but not exceeding 3m.
All as per item No. 1 hereinbefore but depth exceeding 3m but not exceeding 4.5m.
Excavaton in trenches, not exc. 1.5m wide and not exc 1.5m in depth, in hard / dense soil, for foundations, laying pipes, drains or manholes 10 sqm on plan and getting out including trimming sides and forming bottom surfaces to required levels / slopes etc, complete all as specified and as directed .
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, removing excavated soil to a distance n.exc 50m and making good surface in Hard/dense soil complete all as specified and as directed.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed .
Returning, filling in soft disintegrated rock including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removal of surplus excavated material ( rocks) to a distance exc 50m but n.exc 250m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified as directed.
Removal of surplus excavated material ( soils) to a distance exc 50m but n.exc 250m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified as directed.
Surface dressing n exc 15cm deep and getting out in hard / dense soil complete all as specified and as directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and as directed.
Brick work with sub class 'B' bricks (Old size brick) straight or curved on plan exc 6m mean radius built in cement mortar 1:4 and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and as directed.
Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in cover slabs, set in CM 1:4 etc including necessary formwork complete all as specified and directed. Note: Reinforcrment steel will be measured and paid seperately.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Loose filling with broken bricks aggregates of size 40 to 80mm complete all as specified and directed.
Moorum/red bajri filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
Shingle filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and blended with earth and rammed including watering complete all as specified and as directed.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed.
Brick work with sub class 'B' bricks one brick thick honeycomb walling, built in cement mortar 1:6, complete all as specified and directed.
Use and waste of formwork to sides of concrete foundation footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundations, plinth beams and similar works vertical or for batter for rough finished surfaces complete all as specified and directed.
RCC 1:2:4 nominal mix concrete type B1 (using 20mm graded stone aggregate) as in footings, foudation beams, plinth beams bases of columns complete all as specified and as directed
Reinforcement for concrete with steel TMT bars, 10mm dia & over, cut to length, bent to required shape including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips completed all as specified and as directed.
All as per item No 16 here in before but 6mm to 10mm dia in stirrups.
Mild steel framed work such as grills and gratings, etc with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, laddars, framed balusters, walkways, railings, frame wk of water tanks and similar wks confirming to FE 290 Gde E-165 completed all as specified and as directed.
Mild Steel work confirming to Fe - 290, Grade E-165 as in Hand Rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for Balusters Running Bars, for Doors, Balusters, Nosing to Steps including embeding in concrete and screwing etc, Wind Ties for roof including securing bolts, Posts and Struts in Fencing including cutting tops to shape as directed, bending to shape, notching for wire, drilling holes or as in flat iron fillets [for securing wire mesh and barbed wire etc] including all necessary drilling, bolting or riveting, etc and similar work complete all as specified and directed.
Rolled Mild Steel work confirming to Fe 410-W, Grade-E- 250, Quality-A as in Plates [plain & chequered], Channels, Angles, square cut or notched [ordinary or counter sunk] forming holes without any attachment complete all as specified and as directed.
PCC 100mm thick 1:3:6 type C-2 using 40mm graded stone aggregate as in floors etc complete all as specified and as directed.
Hard core of crushed stones/boulders of guage not exc 63mm and depositing, spreading and levelling in layers not exc 15cm th, watering and well ramming complete all as specified and directed.
Boring hole 200mm dia complete by mechnical in any type of soil/rocks complete all as specified and directed.
Supply, lowering and fixing 200mm dia HDPE perforated pipe in easing with PVC fitting cloth complete all as specified and as directed.
S&F PVC Cowl of size 200mm dia complete all as specified and directed.
PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in benching surface channel of drain including necessary form work complete all as specified and as directed.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), exc. 10cm in width and setting in mortar 1:4 complete all as specified and as directed.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), exc. 10cm in width and setting in mortar 1:6 complete all as specified and as directed.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), not exc. 10cm in width and setting in mortar 1:4 complete all as specified and as directed.
Rendering 10mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed.
Plain Cement concrete 1:2:4, type B-0 (using 12.5mm graded crushed stone aggregate) as in coping including necessary form work etc all as directed.
Steel work in tubular post, trusses, including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St -240.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour, having 550 Mpa tensile strength as in roof covering / cladding and fixed with self tapping screws, complete all as specified and as directed.
Preparation of new Steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Preparation of new Steel surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
PCC 100mm thick 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base complete all as specified and as directed.
PCC 40mm thick 1:2:4 type B1 using 20 mm graded stone aggregate as in flooring, finished even and smooth without using extra cement complete all as specified and directed.
PCC 40mm thick 1:2:4 type B1 using 20 mm graded stone aggregate as in sub base complete all as specified and directed.
Plastic dividing strips 1.5mm thick, 22 mm width inserted in position complete all as specified and directed.
Machine pressed pre cast concrete interlocking designer paver blocks in any and shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 grade in path, hardstanding, etc laid over complete all as specified and as directed. Note :- Sand cushioning shall be measured and paid separately.
Sand for cushioning as under floors of paver blocks , compacted by using plate compactor or other suitable mechanical method etc., complete all as specified and as directed.
PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in kerbs / benching, coping including necessary form work complete all as specified and as directed.
Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from the frame), complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 sqm each with shutters (without taking off shutters from the frame), complete all as specified and as directed.
Taking down cement plaster on brick or concrete or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and as directed.
Demolition of brick work, stone/boulder masonry, precast concrete block masonry etc., built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thick (unreinforced) (below or above ground level) all as specified and as directed.
Non-Skid coloured ceramic tiles 7 to 8 mm thick (square/ reactangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, in floor finishes set and joineted in neat cement slurry and pointed in white or colured cement to match over and including 15mm thick screed bed in CM 1:6, etc complete all as specified and as directed.
Non-Skid coloured ceramic tiles 7 to 8 mm thick (square/ reactangular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm, as in vertical surfaces such as skirting, dado etc., set and joineted in neat cement slurry and pointed in white or colured cement to match over and including 10mm thick backing coat in CM 1:4 complete all as specified and as directed.
Preparing new surface of wall and applying two coats of distemper oil bound over chalk whiting priming coat complete all as specified and as directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified.
Point wiring complete with 2 runs of 1.5 sqmm single core, PVC insulated, unsheathed cable 1100 volts grade, multi stranded copper conductor drawn into and including suitable size of PVC conduit and accessories concealed in wall, roof etc., and including provision of one run of PVC insulated 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealed in wall and laminated sheet cover of 3mm thick on top for housing the switches, fan regulator, socket, outlets etc complete for one light point controlled by one switch complete all as specified and as directed.
All as per item No 30 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No 30 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
Switch piano flush, single pole, one way, 5/6 Amp complete all as specified and as directed.
Switch socket combination 2 in 1, 3 pin 5 amps and 15 amps 230 volts flush type universal complete all as specified as directed
Switch socket combination 3 pin 5 amps, 230 volts flush type universal complete all as specified as directed
Sub main wiring complete with 2 runs of 6 sqmm single core PVC insulated unsheathed FRLS cable, 1100 volts grade, multi stranded copper conductor drawn through and including suitable size of PVC conduit pipe and accessories concealed to surface / wall roof etc with one run PVC insulated 6sqmm FRLS cable , copper condutor for earth continuity conductor all as specified and as directed. Note : Three runs of of 6.0 sqmm PVC insulated stranded copper conductor and one run of PVC conduit shall be measured and paid as one unit.
Supply, install, connect, test and commissioning of split type Air conditioner Hi wall comprising of units Indoor & outdoor complete with cordless remote control unit, with inbuilt in air ioniser, Plasma filter for better indoor air quality, leakage detector etc with minimum 5 star rating and EER 3.2 of capacity 2.0 TR including suitable factory made voltage stabilizer with anchor bracket inclusive of suction and discharge lines of suitable size and length of copper tube, necessary brazing and providing nitrile tubing over gas circulating copper tubes and neatly tying the ends with PVC insulating tape and mounting on suitable bracket, suitable drain pipe for disposal of waste water upto ground level and testing, neatly finishing the disturbed surfaces of walls to match with the surroundings complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25m below normal ground level with the top edge of the earth plate not less than 1.5m (B.G.L.) and connected to galvanized iron earth strip 32 x 6mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made out of 8 mm dia round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed. Note:The GI earth strip and 40 mm dia bore light grade GI pipe upto 7.5 m deemed to be included in the rate quoted by the contractor.
Pressed sheet metal enclosure, TPN vertical ( 8 I/C + 12 O/G) metallic double door IP 42 protection, 415V, AC 50Hz with for TPN MCB as incomer and double pole / single pole MCB as out going with tinned copper bus bar of 200 Amp neutral link, earth link and concealed in wall and connection complete all as specified and directed.
MCB TPN 125 Amp , 240V, 50 Hz, 10KA, 'C' series including making electrical connection with Lugs/thimbles complete all as specified and directed.
MCB SPN 63 Amp , 240V, 50 Hz, 10KA, 'C' series including making electrical connection with Lugs/thimbles complete all as specified and directed.
MCB SP 6 -32 Amp , 240V, 50 Hz, 10KA, 'C' series including making electrical connection with Lugs/thimbles complete all as specified and directed.
Recess mounted square 2 feet x 2 feet LED panel die cast body with premium diffuser to ensure glare free and even distribution of light white powder coated CRCA with full window acrylic diffuser 42 W with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparallel light distribution voltage 150 - 270V temp range 0-50degree C,Temp -6500 K complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug socket complete with one single pole MCB20 Amps 240 volts complete all as specified and directed.
Umesh V Patil Contractor
Siddique constructions
m/s raghavendra kulkarni
famous construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .