Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | ₹1.5 Cr | 1 | Accepted-AOC l1 |
| 2 | 2₹1.5 Cr+₹98,034.80 (0.65%)Rejected-Finance | ₹1.5 Cr+₹98,034.80 (0.65%) | 2 | Rejected-Finance Other then lowest |
| 3 | 3₹1.6 Cr+₹6.3 L (4.13%)Rejected-Finance S O SH RAMESH KUMAR VILLAGE PASSAR PO BALH KAWAR TEHSIL LAD BHAROL DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | ₹1.6 Cr+₹6.3 L (4.13%) | 3 | Rejected-Finance Other then lowest |
| 4 | Not Admitted-Fee/PreQual/Technical NOT AVAILABLE | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹2.0 Cr
EMD Value
₹2.3 L
Closing Date
8 Jan 2024, 5:00 pmClosed
EE Chauntra
JS DIVISION CHAUNTRA
Imp. Rem. Of LIS Bharoo, Banaroo, Banog FIS Chhatr Tanoo Kuhl Ghodan Kuhl in Sub-Division Joginder Nagar SH Supply Erection of Pumping Machinery Providing and laying 250 mm dia GMS ERW Grade L 210 or A IS ISO 3183 2007 with butt welding flang
2023_HPIPH_83328_1
Chauntra-15287-336 dated 28-12-2023
Open Tender
Pumps/Motors
Item Rate
270 days
Joginder Nagar
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,500
EE CHAUNTRA
₹2.3 L
Yes
20 Mar 2024
29 Dec 2023
9 Jan 2024
29 Dec 2023
8 Jan 2024
29 Dec 2023
Amount
Supply of submersible clear water pump set of reputed make such as KSB/ Calama / SU or JSV approved conforming to latest relevant BIS code. The pump should be fitted with free flow impellers of suitable alloys as per BIS 8034-1978 latest suitable for lifting raw water having 6000 PPM turbidity, grease packed bearings and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specification. The pump shall be directly coupled to submersible squirrel cage electrical induction motor of same make conforming to BIS 9283-1979 (latest with up to date amendments) totally dust and water proof for submersible duly isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical load with minimum bear and tear. It should also be fitted with a device to take up expention of water with heating of motor. The pump should include water level guard,errection clamps,cable clips and depth gauge etc. and suitable for opration in data given SITE CONDITIONS:- Total Head 12.77 mtrs Discharge required 20.23 LPS each set. No. of Pump required. 2Nos . Location of the site of installation of machinery:- The site is located at a distance of 20 Km from Jogider Nagar The Altitude of :- The Altitude of place is 950 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Type of water and its Raw water Charactristics of water a) Ambient b) Turbidity NTU 600 NTU
c) Hardness 260 Mg/Ltrs -- d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 15 mtrs Dia of Rising main 250 mm dia. No of working hours. 20 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Supply of Direct on line type Star Delta Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filing suitable for 7.50 HP motor.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /crompton make for required motor of 12.50 HP capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
MCB/MCCB of 63 Amp suitable for motor of 12.50 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming to IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN 1.00 ) double flanged sluice valve of 250 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
Supply of Kirloskar/Leader or JSV approved make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 250 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or of Suitable sizes.
Supply of Kirloskar/Leader or JSV approved make 250 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 250 mm dia. of rising i.e.250 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe 300 mm dia. and common header 200 mm dia GMS pipe Medium class as per IS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Supply of floor/wall mounted power factor shunt capacitor of 3 KVAr conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of suitable cable for water level guard
Supply of supporting clamps.
Supply of cable clips of required size.
Errection of all equipment Sr No I to IX including cost of tees,bends,tapers and any other fittungs erquired as per site conditions as per direction of Engineer in charge.
2ND STAGE Centrifugal Pump:- Supply & errection of horizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistage centrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar or JSV approved make conforming to BIS 1520-1980) pump (Latest with up to date amendments, read with BIS: 9137-1978 (latest edition) suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring and shaft motor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a common MS/Cast steel plate (base plate from the principal manufacturer of pumping set) to coupling 3 phase squirrel cage electric induction motor of standard make such as Kirloskar/ NGEF/crompton or JSV approved make conforming to IS 12615-2018 and should be energy efficient minimum IE2 compliant and totally enclosed fan cooled (TEFC) type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts, painting etc. and shall be and suitable for operation on the date given below: SITE CONDITIONS:- Total Head 290.26 Mtr. Discharge required 20.23 LPS each set. No. of Pump required. 2.00 No set Length of R/main 2760.00 mtrs. Dia of R/main 250 mm dia Location of the site of installation of machinery-The site is located at a distance of 22 Km by road & 0.300 KM on head load (for the installation of both machinery). The Altitude of :- The Altitude of place is 1000 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:- 415+ Type of water and its Clear water
Charactristics of water a) Ambient Temperature b) Turbidity NTU 500 NTU c) Hardness 260 Mg/Ltrs -- d) PH Value 7.5 -- e)Total Solid Mg/Lts)PH Value -- No of working hours. 12 Hours. Limit of Pump (-) 15% (+) 10% R. M.P. of Pumping RPM(or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing ICTP Main Switch 320 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
O.C.B. 300 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
Power factor meter of AE/L&T Rishab make as per IS: 1248 (Part - V ) 1983 (Latest edition) with up to date amendments of suitable rating.
Frequency meter of AE/ L&T Rishab make as per IS: 1248 (Part - IV ) 1983 ( Latest edition) with up to date amendments of suitable rating.
Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 100 Amp.
ICTP switches with HRC fuses of L&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 100 Amp.
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
Capacitor of L&T make as per IS:2834 -1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of 31 KVAr rating according to HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064 (Part - II) 1978 with upto date amendments
Providing suitable Auto Transformer starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
Providing double flanged Cast steel sluice valve of Kirloskar/Leader or JSV approved make for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class ASA-300 size equal to dia of suction pipe)
Providing double flanged Cast steel sluice valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1414/API-600 (Class ASA-300, having size one step higher to delivery of pump).
Providing double flanged 250mm Cast steel reflux valve of Kirloskar/Leader or JSV approved make and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300, having by pass arrangement and size one step higher to delivery of pump). .
Providing double flanged Cast steel 250 mm non return valve of Kirloskar/Leader or JSV approved make having bye pass arrangement for rising main and capable of with standing normal sseat pressure of 52 kg/cm2 as per BS:1868/API-600 (Class ASA-300)
Providing 200 mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
Providing 200 mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
Providing and fixing double flanged250 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 300 mm dia Min. length = 10 mtr.
(ii) Delivery pipe 200 mm dia -do- = 6 mtr.
(iii) Common Header 250 mm dia -do- = 6 mtr.and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
(i) Motor side: 95 mm2 Min length = 20 mtrs.
(ii) Supply side: 120 mm2 Min. length =10 mtrs.
Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
Excavation in foundation and trenches etc.(in pipes and pits) in all kinds of soils such as pick work, jumper work, blasting in soft / hard rock, chiselling/wedging out of rock/ where blasting prohibited) saturated soil stacking the excavated earth within all leads and lifts clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by the Engineer –in-charge.
Providing, laying, jointing and testing in trenches of galvanized MSERW flanged pipes excluding cost of flanged bends of all degrees conforming to IS/ISO 3183-2007 Grade L210 or A as per dimensions weight and test pressure mentioned below in a random length of 4m - 6m, The M.S. flanges are to be provided 5% of total joints as per table below conforming to IS: 6392-1971 (latest upto date amendments) and welding of flanges with pipes as per IS: 816-1965 with a electrode as per IS: 814-1967 including required Nos. and size of M.S. nut and bolts as per IS: 1369-1967 and compressed asbestos fiber jointing gaskets sheet not less than 3mm thick sas per IS: 2712-1965 & 90% butt welded joints by considering minimum three layers. The welding of flanges to be done on both faces in two layers on outer face + one layer on inner face to make the joints leak proof and to the entire satisfaction of the Engineer-in-charge. The laying of pipes should be conformed to IS: 5822-1994 (earth work in trenches, MS flanges and butt welded joint to be measured and paid for seprately) . The pipe shall have zinc coating as per IS:4736 in factory latest with upto date ammendements.Booster Stage:- Source to WTP 250 mm dia MSERW Pipe IS/ISO 3183-2007 Grade L210 ( Part-I grade medium having wall thickness ( R.D. 0 TO 15 )
Booster Stage:- 1st stage :-250 mm dia GMS/ERW Grade -L-210 or A IS/ISO 3183 : 2007 wall thikness 4.80
0/0 to 1200 PH to 1st stage 250 mm dia GMS/ERW Grade -L-290 orx42 IS/ISO 3183 : 2007 wall thikness 4.80
1200 to 2760 PH to 1st stage 250 mm dia GMS/ERW Grade -L-290 orx42 IS/ISO 3183 : 2007 wall thikness 4.80
Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS: 6392-1971 (Latest with upto date amendments) with plain end GMS/MSERW pipe in requsite number of layers on both faces to make the joint leak proof (The cost of providing and laying of MSERW pipes to be measured and paid for seprately). The welding of flanges should conform to IS:816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364. including cost of gasket sheet nuts & bolts. The thickness of gasket sheet not less then 3.00 mm conforming to IS 2712-1998. The work shall be done to the entire satifaction of engineer in charge with in all leads and lifts.tion of Engineer-in-Charge. Booster Stage:- Sorce to WTP 250 mm dia MSERW Pipe IS/ISO: 3183-2007 ( Part-I grage mediu having wall thickness ( R.D. 0 to 15 )
Booster stage Ist Stage 250 mm dia GMS/ERW Grade -L-210 or A IS/ISO 3183 : 2007, wall thicness- 4.80 Flang table-1
0 to 600 250 mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L-290 OR x 42 wall thicness- 4.80, Flang table-28
600 to 1500 250 mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L-290 OR x 42 wall thicness- 4.80, Flang table-23
1500 to 2100 250 mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L210 OR A wall thicness- 4.80 Flang table-17
2100 to 2400 250 mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L290 OR A wall thicness- 4.80 Flang table-11
2400 to 2760 250 mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L290 OR A wall thicness- 4.80 Flang table-5
Providing circumferencial Butt welded joints by electrical arc welding to GMS/MSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes conforming to IS:814-1991, at site of work complete in all respects, including manual / mechanical handling of pipes and including DPT in all leads and lifts to the entire satisfaction of Engineer-in-Charge. Booster Stage:- Sorce to WTP 250 mm dia MSERW Pipe IS/ISO: 3183-2007 ( Part-I grage medium having wall thickness ( R.D. 0 to 15 )
Booster stage:- Ist Stage 250 mm dia GMS/ERW Grade -L-210 or A IS/ISO 3183 : 2007 wall thikness 4.80
0/0 to 1200 250mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L290 OR x 42 wall thikness 4.80
1200 to 2760 250 mm dia MSERW Pipe IS 3183 IS/ISO 3183 : 2007 L290 OR x 42 wall thikness 4.80
puneet angra
Lalit Pal
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .