| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.4 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹19.7 L+₹2.2 L (12.6%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹22.1 L+₹4.6 L (26.5%)Rejected-Finance 11 753 1 HABIBULLA STREET KADAPA CUDDAPAH ANDHRA PRADESH 516001 | Y S R | ANDHRA PRADESH | 516001 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
| Sl No | Description | Qty | Unit | KRISHNA CONSTRUCTION COMPANY L2 | Deccan Enterprises L3 | The Home Plus L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed. | 189.6 | CUBIC METRE | 185 ₹35,076 Lowest | 250 ₹47,400 | 275 ₹52,140 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed. | 132.83 | CUBIC METRE | 40 ₹5,313.2 Lowest | 50 ₹6,641.5 | 175 ₹23,245.25 |
| 3.00 | Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 51.77 | CUBIC METRE | 50 ₹2,588.5 | 40 ₹2,070.8 Lowest | 50 ₹2,588.5 |
| 4.00 | M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed.
Note- Punned down thickness will be measured for payment purpose. | 22.58 | CUBIC METRE | 270 ₹6,096.6 Lowest | 350 ₹7,903 | 550 ₹12,419 |
| 5.00 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over ground cable for protection complete all as specified and directed. | 1,211 | EACH | 22 ₹26,642 Lowest | 36 ₹43,596 | 38 ₹46,018 |
| 6.00 | Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed.
Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.
(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. | 110 | RUNNING METRE | 540 ₹59,400 | 600 ₹66,000 | 310 ₹34,100 Lowest |
| 7.00 | Supply and laying/ fixing of GI tube, light grade, 50mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light poles or as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. | 12 | RUNNING METRE | 250 ₹3,000 | 300 ₹3,600 | 135 ₹1,620 Lowest |
| 8.00 | M&L for Sub main wiring with 4 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 32mm ISI marked with all accessories fixed on wall/roof and Two run of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed.
Note : Four runs of 10 Sqmm cable, two run of 10 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length. | 90 | RUNNING METRE | 340 ₹30,600 Lowest | 400 ₹36,000 | 800 ₹72,000 |
| 9.00 | M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 25mm ISI marked with all accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed.
Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length. | 120 | RUNNING METRE | 310 ₹37,200 Lowest | 450 ₹54,000 | 550 ₹66,000 |
| 10.00 | M &L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 20mm ISI marked with all accessories fixed on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed.
Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length. | 520 | RUNNING METRE | 120 ₹62,400 Lowest | 250 ₹1,30,000 | 350 ₹1,82,000 |
Tender Value
₹21.2 L
EMD Value
₹42,420
Closing Date
9 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Nitish Pathak, EE
GE (AF) Phalodi PIN-342301
PROVN OF CERTAIN MW AND RW AT AF STN PHALODI
2025_MES_730360_1
8736/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Stn Phalodi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹42,420
Yes
28 Nov 2025
11 Sept 2025
16 Oct 2025
11 Sept 2025
9 Oct 2025
25 Sept 2025
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out for laying underground cable in soft/losse soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for dry tibba sand in trenches for cushioning to under ground cable spreading, levelling, hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over ground cable for protection complete all as specified and directed.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
Supply and laying/ fixing of GI tube, light grade, 50mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light poles or as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed.
M&L for Sub main wiring with 4 runs of 10 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 32mm ISI marked with all accessories fixed on wall/roof and Two run of 10 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor including taking down old unsv submain wiring complete all as specified and directed. Note : Four runs of 10 Sqmm cable, two run of 10 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length.
M&L for Sub main wiring with 2 runs of 6 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 25mm ISI marked with all accessories fixed on wall/roof and one run of 6 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length.
M &L for Sub main wiring with 2 runs of 4 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable drawn through and PVC conduit of size 20mm ISI marked with all accessories fixed on wall/roof and one run of 4 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLSH 1100 volts grade cable as earth conductor complete all as specified and directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth conductor and one run of PVC conduit shall be measured and paid as one unit length.
S&F for Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board triple pole & neutral 415 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S & F ON load change over switch 415 V in sheet metal enclosure 4 pole of capacity 200 AMP complete all as specified and directed.
S&F MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F MCB SPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F MCB SP 06 to 32 Amp current carrying capacity in the DB complete with connection testing and commissioning C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F MCB TP 25 to 63 Amp current carrying capacity in the DB complete with connection testing and commissioning C curves MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F 20 mm bore galvinised steel water tubing 'medium grade' including necessary fitting such as GI bends, tee, union, etc fixed on walls or laid in trenches complete and connecting to water supply pipe line complete all specified and directed.
S&F 15 mm bore galvinised steel water tubing 'medium grade' including necessary fitting such as GI bends, tee, union, etc fixed on walls or laid in trenches complete and connecting to water supply pipe line complete all specified and directed.
S&F 15mm Bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fixed complete all as specified and directed.
Taking down ceiling fans of any size of any make fixed/hanged at different location in Air Force station, dismantling the fan complete, cleaning and re-assembling the same including replacementof MS down fan rod with anti suicide down rods, split pins, flexible copper cable, ,Fan Cups, MS fan Clamp including nut, bolt, washers, rubber real and refixing the ceiling fan on the same location in original position, testing and commissioning of fan for smooth running as per entire satisfaction of Engr-in-charge complete all as specified and directed. Note :- Supply & Fixing of Anti Sucide MS Down rod shall be measured and paid under respective item of BOQ.
S&F 18 inch 'Gold life" Smart MS down rod (Anti Suicide Fan Rod) white colour for ceiling fans of any type and make complete all as specified and directed.
M&L for preparing on newly plastered wall surfaces and finishing wall with Acrylic smooth exterior paint in one or more tint and pattern ( camouflage) as approved of required shade: New work ( Two or more coat applied @ 1.67 Ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for RCC (nominal mix) M-25 using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level), with top edge of the plate vertically to depth of not less than 1.5 m below normal ground level connected to and incl GI strip 25x4 mm and GI pipe 40 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl PCC cover and , watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete( Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner.) complete all as specified and directed.
M&L for Mild steel TMT MS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Cement Concrete (1:2:4) type B1 using 20mm graded stone aggregate for pole base foundation and coping complete all as specified and as directed.
S&F LT feeder pillar box factor made cubical type dust proof, out door type both side opening of size 100 x 80 x 40 cm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of 400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate complete incoming / outgoing cable provision complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches of size 40 mm including fittings Viz Tees, Socket bends elbows, unio, nipple etc screwed and socketed joint complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches of size 25 mm including fittings Viz Tees, Socket bends elbows, unio, nipple etc screwed and socketed joint complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches of size 20 mm including fittings Viz Tees, Socket bends elbows, unio, nipple etc screwed and socketed joint complete all as specified and directed.
Supply and fixing PVC ball valve of size 40 mm complete all as specified and directed.
Supply and fixing PVC ball valve of inlet size 25 mm complete all as specified and directed.
Supply and fixing PVC ball valve of inlet size 20 mm complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage tanks tripple layer of 500 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed.
M&L for Rotational moulded polyethylene water storage HDPE triple layer white colour tanks of 5000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed.
M & L for Boring of holes under road /pavement/hard standing or any other situation by mannual means for 80mm bore for crossing the pipe line complete all as specified and directed.
Supply, installation and testing of centrifugal monoblock pump 5.0 HP three phase 440 volt head range 38 mtr,discharge 8.9 LPS model no. KDS 538 Make kirloskar complete all as specified and directed.
Supply and fixing PVC insulated copper conductor unshethed multistranded 3 core 6 sqmm copper cable complete allas specified and directed.
S & F DOL starter in steel sheet enclosure AC 3 phase, 240 Volts, 50 Hz type with single phase preventer, dry run preventer, overload protection, reverese phase protection suitable for 5 HP monoblock pump set complete all as specified.
Material and Labour for Construction of valve pit chamber of size 120 cm x 120 cm x 120 cm ( internal dimension ) of brick masonry built in cement mortar (1:4). from the top of surface including cover of MS sheet 3.15 mm thick and MS frame made of angle iron of size 50 mm x 50 mm x 6 mm with hinges, handle and locking arrangement including painting with two coats of synthetic enamel paint over a coat of red oxide primer and grouting in PCC (1:2:4) type B-1, using 20 mm graded crushed stone aggregates , Rendering 15 mm thick in cement mortar (1:3), including three coats of white wash on internal surfaces and external exposed surfaces , foundation concrete (1:3:6) type C-2 using 40 mm graded crushed stone aggregates including necessary earthwork , returning filling , removal including demolition the existing valve pit complete all as specified and directed. Note : Drawing of Valve pit cover shall be approved by Engineer-in-charge before execution of the work.
Supply, laying, testing and commissioning cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, elecric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4.0 core complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc. (ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately.
S&F sheet metal enclosure MCB distribution board single pole & neutral 240 volts 4 way with 200 AMp rated bus bar IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
S&F for MCCB 3 Pole .415 V. fixed type,25 to 100 Amps with breaking capacity 16 KAcomplete all as specified and directed.
Supply, installation and testing of dewatering pump( Sewage cutter) of capacity 5.5 HP, 3 Phase 415 volt complete all as specified and directed.
Supplying and Fixing copper cable PVC insulated multistranded FRLSH 6.0 Sqmm 4 Core, 1100 volt industrial cable as per IS :694 including cable passing through PVC conduit of suitable size fixed on wall complete all as specified and directed.
Supplying and Fixing copper cable PVC insulated multistranded FRLSH 10.0 Sqmm 4 Core, 1100 volt industrial cable as per IS :694 including cable passing through PVC conduit of suitable size fixed on wall complete all as specified and directed.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm galvanised iron strip complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated completion complete all as specified and as directed.
S&F 50 mm bore galvinised steel water tubing 'medium grade' including necessary fitting such as GI bends, tee, union, etc fixed on walls and ceilings or laid in floors complete and connecting to water supply pipe line complete all specified and directed.
S&F DOL Starter submersible sludge pump controller of capacity 7.5HP in steel sheet enclosure AC 3Phase, contactor range 20 Amp over load relay range 13 to 20 Amp 415 volts 50 Hz type with three phase preventer, dry run preventer, overload protection, rverse phase protection complete all as specified and directed.
KRISHNA CONSTRUCTION COMPANY (BID ID -3441017)
Deccan Enterprises (BID ID -3445905)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .