Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 CrAccepted-AOC | ₹8.4 Cr | L1 | Accepted-AOC Being lowest bidder |
| 2 | L2₹8.9 Cr+₹48.1 L (5.69%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹8.9 Cr+₹48.1 L (5.69%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | Rejected-Technical PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | - | - | Rejected-Technical Due to two class lower |
Tender Value
₹7.7 Cr
EMD Value
₹7.1 L
Closing Date
2 Jun 2020, 6:00 pmClosed
CE Jodhpur Zone
HQ CE Jodhpur Zone Jodhpur
PROVN OF AUDITORIUM CUM CINEMA HALL AT AHMEDABAD
2019_MES_299616_2
800485/AMD/2019/E8
Open Tender
Civil Works
Lump-sum
821 days
Ahmedabad
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹3,000
GE Army Ahmedabad
₹7.1 L
Yes
21 Jul 2020
14 Mar 2020
4 Jun 2020
14 Mar 2020
2 Jun 2020
18 May 2020
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 31
Lump sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK" as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 33
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 34
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 37
Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT etc." as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 39
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 41
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 43
Lump sum price worked out by the contractor for "COMPOUND WALL & GATE" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.45
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 46
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.52
Lump sum price worked out by the contractor for "LIGHTNING PROTECTION " as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 53
Lump sum price worked out by the contractor for "SUMMER APPLIANCES" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 54
Lump sum price worked out by the contractor for "FIRE FIGHTING AND FIRE DETECTION " as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.58
Lump sum price worked out by the contractor for " AIR CONDITIONING " as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.61
Lump sum price worked out by the contractor for " DEMOLITION AND DISMANTLING " as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.63
Sch 'A' Sec-XVII (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-II (Excavation and earthwork schedule).
INTERNAL ELECTRIFICATION:
S & F 63 A panel mounted (3P + N + E) angled socket, conforming to IEC 60309- 1 & 60309- 2, having IP 67 ingress protection & IK 08 impact protection suitable for 415 V, 50 Hz electric supply complete as per Le-grand catpart No. 81283 or techno comeercial equvivalent as specified and directed, with wiring all as specified and directed engr-in-charge
S & F 32 A panel mounted (3P + N + E) angled socket, conforming to IEC 60309- 1 & 60309- 2, having IP 67 ingress protection & IK 08 impact protection suitable for 415 V, 50 Hz electric supply complete as per Le-grand catpart No. PKF32F735 or techno comeercial equvivalent as specified and directed, with wiring all as specified and directed engr-in-charge
Supply and fix telephone modular socket multipurpose for telephone as per Le-grand catpart No. 573425 or techno comeercial equvivalent all as specified and directed .all as specified and directed engr-in-charge
Supply & Fixing 15 Amps Pop-up Sockets Flush Mounitng boxes with push & slide Locking system near to stage completes as per Le-grand cat part No. 054010 or techno comeercial equvivalent all as specified and directed engr-in-charge.
Supply & fixing of Recessed mounted adjustable 30 Watt LED downlight for accent lighting, White powder coated recessed mounted fixture.Pressure die cast aluminum housing with highly effecient reflector & with Dali dimmable ballast including testing & commissioning on completion with complete in all respect. all as specified and directed. engr-in-charge as per make Bajaj Cat No. 112085BZRSQL 30 GZWH or techno comeercial equvivalent all as specified.
Supply & fixing Batten holder 9W LED , low height lighting fixture with driver including testing & commissioning on completion with complete in all respect as per make Achor Cat part No. 39946 or techno comeercial equvivalent all as specified.
Supply & fixing of Recess mounted 34 W LED 2'x2' White powder coated CRCA housing with LEDs. Seamless front frame with white coloured flat acrylic cover with ballast including testing & commissioning on completion with complete in all respect. all as specified and directed. engr-in-charge as per Make Bajaj Cat No. 112682 BZRSQL GX 34W CW or techno comeercial equvivalent all as specified.
Supply & fixing of Recess mounted 18W LED 1'x1' White powder coated CRCA housing with LEDs. Seamless front frame with white coloured flat acrylic cover with ballast including testing & commissioning on completion with complete in all respect as per Make Bajaj Cat No. 11656 BCTBLR 18 ZTWH or techno comeercial equvivalent all as specified.
Supply & fixing Batten light 9W LED , low height lighting fixture with driver including testing & commissioning on completion with complete in all respect as per Make Havells Cat No. LHEBLP7INW009 or techno comeercial equvivalent all as specified.
Supply & fixing of Recessed mounted adjustable 9W LED downlight for accent lighting, White powder coated recessed mounted fixture.Pressure die cast aluminum housing with highly effecient reflector & with Dali dimmable ballast including testing & commissioning on completion with complete in all respect as per Make Havells Cat No. LHEEGEPBIE1W009 or techno comeercial equvivalent all as specified.
Supply & fixing of 15W/ Mtr LED Strip for cove lighting complete with driver & in all respect including testing & commissioning on completion as per make Bajaj Cat No. 112492 75 W PROFESSIONAL LED strip IP-65 WH White or techno comeercial equvivalent in Philips/Wipro.
Supply & fixing of 4W LED foot/ step lighting fixture complete with driver & in all respect including testing & commissioning on completion as per make Bajaj Cat No. 111711 BLSGV 4 W LED WH or techno comeercial equvivalent in Philips /Wipro.
Supply & fixing of Digital dimmer unit 1 channel, single phase, dip switch for digital address, digital lamps pre-heat control including short circuit protection, standard input/ output, DMX with 3 pole XLR female input/ output & over load protection complete in all respected as specified & instructed.
Supply of LED tube light wall / ceiling mounting, minimum capacity of 1 x 20 W LED box type tube light with system lumens with system efficacy > 115 Lm /W at System level (including the driver loss) . The Luminaire should have Cool day light color temp of 6500 K CRI> 80. Life 40,000 burning hours with 70% lumen maintenance . PF > 0.95 Surge protection of > 2 KV. All the photometrical and electrical parameters must be supported by LM 79-80 test report from NABL, Accredited Lab OR UL Switching cycle of 50,000 times, lamp starting time is not more than one sec. The LED tube light confirms to applicable IS 10322/EN 60598. Housing of Batten should be made from single piece powder coated CRCA sheet steel. Notes:1. Warranty for replacement of each LED shall not be less than 2 years from the date of purchase.2. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty + benifits as per make Bajaj Cat No. 112114 BRTX 20 W LED 4F NW or techno comeercial equvivalent as approved by GE.
Supply and fix street light fitting LED lamp type 45 W single phase 240 V with all fittings/fixtures prewired, gear cum reflector made of CRCA sheet steel, canopy made of Die cast aluminum painted with stove enameled white paint inside and grey outside, highly transparent clear ribbed acrylic cover held in aluminum frame and screwed to canopy with rubber gasket with hing arrangement including 25 mm dia galvanised iron pipe light grade bracket bent to shape over all length 1.6 mtr fixed to wall with 2 Nosclamps made of flat iron of size 25 x 6mm and suitable bolts and nuts with washers, including connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqm three core from ceiling rose to fitting all as specified and directed, Street light fitting as per make Bajaj Cat No. 169799 BRTFG 45 W LEDI or techno comeercial equvivalent as approved by GE..
Supply and fixing ceiling fans 1200mm sweep 3 blades, double ball bearing BLDC Fan ,energy efficient incl down rods 1 m length and connecting up with 3 runs of 1.5 sq mm, single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan complete all as as per Havells cat No. Stealth Air or technocommercial equvivalent as specified and directed.
S&F heavy duty, corrosion resistant ,exhaust fans of 450 mm sweep 1400 RPM suitable for SP 230/250 v 50 Hz AC supply complete with bird screen protection including fixing/grouting of frame in RCC pipe 450 mm dia, wall and cutting opening embedded complete and connecting with and including 3 Nos 1.5 Sqmm single core, PVC insulated but unsheathed FRLS cable with multistranded copper conductors from ceiling rose to fan and RCC pipe 450 mm dia for placing of fan all as per havells cat part No. Turbo force SP or techno commercial equvivalent as approved by GE.
S & F MCB, TPN, 63 Amps, 415 volts, 10 kA, "C" Series curve complete all as specified and directed.as per Legrand cat Part No. 4086 61 or technocommercial equvivalent all as specified.
S & F MCB, TPN, 32 Amps, 415 volts, 10 kA, "C" Series curve complete all as specified and directed.as per Legrand cat Part No. 4086 58 or techno commercial equvivalent all as specified.
Supplying and laying one pair of 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in existing surface/recessed PVC conduit as required of make RR cable or techno commercial equvivalent of Legrand/L & T.
Supplying and laying two pair of 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in existing surface/recessed PVC conduit as required of make RR cable or techno commercial equvivalent of Legrand/L & T.
Supplying and laying of UTP 4 pair CAT 6 LAN , 1 run Cable in and including recessed PVC conduit as required of make RR cable or techno commercial equvivalent of Legrand/L & T.
S & F MCB, SP, upto 32 Amps,240 volts, 10 kA, "C" Series curve complete all as specified and directed as per Legrand cat Part No. 4085 090 to 095 or technocommercial equvivalent all as specified.
S & F MCB, SP, 63 Amps,240 volts, 10 kA, "C" Series curve complete all as specified and directed.as per Legrand cat Part No. 4085 098 or techno commercial equvivalent all as specified.
S & F ISI marked RCBO 32 A, 30 mA, 415 V, RCBO for AC applications, conforming to IS: 12640 (Part 2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.
S & F ISI marked RCBO 63 A, 30 mA, 415 V, RCBO for AC applications, conforming to IS: 12640 (Part 2)- 2016, having front face indication for earth leakage fault, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.
S & F vertical triple pole & neutral, DB, 8 way double door, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 160 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed as per Legrand cat Part No. 6077 41 or technocommercial equvivalent all as specified. NOTE: MCCB/MCBs shall be measured and paid separately.
S & F vertical triple pole & neutral, 100 A, 415 V, Ics = Icu = 16 kA, 50 Hz MCCB with fixed magnetic settings and adjustable thermal setting (0.7 - 1 X In) TMD trip unit-double door, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 160 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. as per Legrand cat Part No. 4200 15 or technocommercial equvivalent all as specified. NOTE: MCCB/MCBs shall be measured and paid separately.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, 4 runs of 4 sqmm main cable and two runs of 4.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB PVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Four runs of main cable + two runs of earth conductor and one run of PVC conduit shall be measured as one RM.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, four runs of 6 sqmm main cable and two runs of 6.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB PVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Four runs of main cable + two runs of earth conductor and one run of PVC conduit shall be measured as one RM.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, four runs of 10 sqmm main cable and two runs of 10 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB PVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Four runs of main cable + two runs of earth conductor and one run of PVC conduit shall be measured as one RM.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, 2 runs of 2.50 sqmm main cable and one runs of 2.50 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB PVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Two runs of main cable + one runs of earth conductor and one run of PVC conduit shall be measured as one RM.
M & L for submain wiring using ISI marked 1.1 kV grade single core HR- FR flexible cable, 2 runs of 4.00 sqmm main cable and one runs of 4.00 sqmm earthwire conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in and including not less than 25 mm NB UPVC medium grade recessed conduits, conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor, all complete as specified and directed. Note: - Two runs of main cable + one runs of earth conductor and one run of UPVC condduit shall be measured as one RM.
M&L for marking of centre line, stop line, dahses, arrows, letters, brackets & similar work on road surfaces as per IRC pattern with 2mm thick thermo plastic compound of approved quality using 8% mica of white/yellow colour as approved of temperature 160 degree C with special applicator machine including cleaning of road to remove all loose dirt etc, traffic diversion arrangement complete all as specified & directed. MAKE: ASIAN / SHALIMAR / SN industries-Delhi / Maruti Reflo Mark or equivalent as approved by GE.
EXTERNAL WATER SUPPLY
M & L for cutting of CI/DI water mains raising pipe line upto 150 mm in exisiting position for branch connection including M & L for insertion of DI Tee of size 150mm x 150 mm x 100 mm, lead joints,collars,rubber coupling,nuts,bolts of size suitable including accessories complete all as specified.
Supply, fix, testing and commissioning monoblock pump set with all fixing arrangement with foundation of capacity 2 HP (1.5 KW), three phase AC power supply 300-440V, 50 Hz, discharge cap 4.5 LPS at 16 Mtr head, with foundation bolt fixing on RCC under ground sump complete al as directed. Make : Kirloskar or equvivalent. The capacity of pump set shall be as approved by Engineer-in-charge.
M & L for brick masonry valve pit (type) B of size 750 x 750 x 600 mm (internal dimension) complete with plastering internally on walls , MS angle iron 40 x 40 x 6mm frame work & 3 mm MS sheet top cover openable through hinges including necessary locking arrangement, all as per TD drawing including necessary excavation and earth work in any type of strata and two coats of anti-corrosive paint over a coat of zinc primer on steel surface complete all as specified and directed.
M&L for non return sluice valve both end flanged type, ISI mark size 50 mm bore including jointing work and nut bolt washer and gasket complete all as directed. Make – Kejriwal /Venus/Hazra.
Supply and fixing fully cyclic dust & vermin proof cubicle outdoor type motor control starter Panel. The panel shall be Fabricated from powder coated 3 mm CRCA sheet comprising of : Incomer : One incoming main isolation TPN MCB of 16 A rating. One fully taped three phase copper bus bar of 32 A capacity in seperate bus bar chamber. One square panel type digital Voltmeter for reading voltage between phases. One panel type digital Ammeter with 3 phase indication lights. Outgoing : 1 No. Full automatic star delta starter with contractors of suitable capacity for 2 HP Motor, including all connection with suitable size of copper wire in different colour code.
EXTERNAL ELECTRIC SUPPLY
Supply, installation, testing and commissioning of integral driver LED street light with a nominal system lumen output of 7200 lumens and a minimum system efficacy of 90 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours before reaching at L70. The luminaire should have cool white colour temperature (CCT > 5000K) and a CRI >70. The luminaire shall meet IP 66 rating & IK05 rating with THD < 20% & PF > 0.9. The luminaire housing should be made of pressure die cast aluminium with a flat glass optical cover. The total power consumption should not exceed 90 watt including driver and suitable connecting wire from junction box to light fitting complete . Make - Philips or equivalent in GE Lighting or Wipro Cat No LR02-102-XXX- 57-XX as approved and all as specified and as directed
Each Load break Switch (R) includes :- Manual Operated SF6 three position switches with position ON-OFF Manual Operated spring mechanism OFF-EARTH Mechanical indicators for position ON-OFF-EARTH. Mimic diagram at the front facia of RMU Socket for Capacitive Voltage Indicator (VPIS) fixed type, Leenan make, (N-1) No. of FPI is considered per set of RMU where N = no. of R feeders. Counter for measurement of mechanical operations. Padlocking facility, Provision for connecting maximum 1Rx3Cx300 sq mm Aluminium power cable Accessories with each RMU includes, Operating handle - 1 No and Cable Boots - 1 set per Feeder. Accessories with each RMU includes:- Operating handle - 1 No. Cable Boots - 1 set per Feeder
S&F street light junction box with thermoplastic, IP 65 cable junction box with metric knockouts on all sides for cable entry size: 200 x 160 x 98 mm as per Hensel cat ref no. K 9250 or equivalent in Eaton or Rittal or Secure duly fitted with followings:- One number DIN Rail (35 mm)., Four numbers ELMEX or equivalent make connector of 10 sqmm, One number ELMEX or equivalent make end plate, Two numbers ELMEX or equivalent make end clamps, One number MCB SP 6 amp, 10 KA, 'C' series all as specified and directed.
Supplying only Rubber Electric hand gloves full length for 11 KV .Make : Jaipuriya Brothres Ltd or equivalent
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe nominal dia 80 mm & inner pipe nominal dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with GI strip 25x4 mm from pit to high mast light, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 1.0 ohm including excavation and earthwork in any type of strata, complete all as specified.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 5 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
NOTES : (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M & L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
NOTES :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
STAGE LIGHTING: - The rates quoted for stage lighting items as below shall be inclusive of Interconnect of Make - Neutik/ Samson / Standard for Lighting Complete Lightings and related work as required on site.
Supply install testing and commisioning (SITC) of Stage 380w led moving head beam light must have Voltage 100v-240v/50-60Hz DMX Channel 24CH Lamp 440W Pan scan 540°(16bit) electric correction Certificate CE & ROHS Focus linear focus CTO: 3200K to 6500K With RDM function Color wheel: 14 colors + open,Variable direction rainbow effect with speed adjustable Fixed Gobo wheel: 14 Gobo + open Prism: 8 + 16-facet prism Pan scan:540°(16bit) electric correction Tilt scan:270°(16bit) electric correction OEM aurtorization must submitted. Make - Fidelity- catlouge F-MH7R or techno commercial equivalent in/ Robe / Park ley / Martin Lightings
Supply install testing and commisioning (SITC) of LED COB wash light 150w Working Temperature(℃): 20 - 50 IP Rating:IP20 for indoor Emitting Color:COB RGB Lamp: 150W, R,G,B Input Voltage(V):AC100-240V 50/60Hz CRI (Ra>): 90 Working Lifetime(Hour):100000 Certification:CE, FCC, RoHS Control signal: DMX DMX Channel:6 OEM aurtorization must submitted OEM aurtorization must submitted Make - Fidelity catlouge F-Wash RGBW or techno commercial equivalent in / Robe / Park ley / Martin Lightings
Supply install testing and commisioning (SITC) of Stage lights 1 watt rgb ilda dmx laser lights Laser color RGB full color Laser power 100mWGreen, 500mWRed, 500mWBlue Wave length Green 532nm, Red 638nm, Blue 450nm Play mode Sound active, Auto, DMX 512, ILDA PC Laser patterns More than 128 patterns and effects Scanner High speed optical scanner 20K Power 100-240V, 50/60HZ, 150W OEM aurtorization must submitted Make - Fidelity Lightings FL-1W or techno commercial equivalent in / Martin / LPS
Supply install testing and commisioning (SITC) of LED light with strobe effects from the Beam with variable flash rate, flash duration and intensity Ramp up/down intensity modulation effects Random flashes continuous blinder effect, Extended DMX mode For RGB control Light source: 228x3W white LEDs (Strobe ) 64x 0.2w RGB LEDs (backlight) array Minimum LED lifetime: 50 000 hours Resolution:8 bits per color plus8-bit dimming Control systems: DMX DMX channels: 14 Channels Setting:Control panel with backlit monochrome display OEM aurtorization must submitted Make - Fidelity Lightings FS-LED or techno commercial equivalent in / Robe / Park ley / Martin Lightings
Supply install testing and commisioning (SITC) of Professional lighting console with 24 preset channels, assignable to 512 DMX channels Up to 3 DMX channels can be controlled per preset channel 120 scenes storable in 10 banks Integrated chaser with up to 650 steps featuring sync-to-bass beat Frequency-dependent sound-to-light function Dimmer control via DMX or analog output (0/+10 V) MIDI interface for cascading of 2 Controller (master/slave setup) 2 additional, multi-functional channels for special effects (fog machine, color changer, etc.OEM aurtorization must submitted Make - Fidelity Lightings F-LC152 or techno commercial equivalent in / Behringer / Perl / Avolite.
Supply install testing and commisioning (SITC) of high Quality DMX Cable Jacket PVC, ø 8.80 mm, marine blue Shield No. 1 Bare copper wires (0.10 mm), 100% coverage Shield No. 2 Bare copper wires (0.10 mm), 100% coverage Layer Polyester nonwoven thermally bonded, both sides alum. coated Separation Filler material viscose Conductor shield layer Polyester nonwoven thermally bonded, both sides alum. coated Cond. copper shield Bare copper wires (0.10 mm), 100% coverage Isolation Cellular PE, ø 2.00 mm, 4 different colors Conductor Stranded bare LCOF copper wires, 64 x 0.10 mm (4x) (0.50 mm²) Make - Gothem Cables / Fidelity / Belden / QED
M & L MS work for fabrication for frame work using MS sections ,MS tubes, Mounting Hardwares C clamps, etc.of any description type and size as per OEM recommondations and standards, including bending, cutting, welding, nuts, bolts, washers of required size including painting two coats of synthetic enamel paint over priming coat of red oxide complete all as sepcified and directed for stage lighting brackets, audio-video- speaker clamps ,screen mounting frame work, brackets for stage curtains.
Supply install testing and commisioning (SITC) of Certified to IEC/EN 61643-1 Branch Circuit surge protection and power conditioning For audio / Video / Stage Lightings panel.in built with a professional-grade NEMA magnetic shielding steel enclosure eliminate surge energy up to 6,000 volts without producing harmful side effects such as earth contamination or common-mode disturbances. Nominal line to neutral voltage U0 (V) 240V Max.Cont. Operating Voltage Uc (V) 240V 260VAC Voltage protective level Up (V) 1KV Max. shorted current. (Isc) 3KA Open circuit voltage (Uoc) 6KV TOV characteristic (UT) TOV withstand , tT = 5s, UT=335V; Applicable Power Supply System TN TT IT Number of ports Two Voltage regulation ≤ 1% Operation temperature and humidity -40 - +35°C, 30-90% OEM aurtorization must submitted.
AUDIO AND VIDEO ITEMS: - The rates quoted for audio video items as below shall be inclusive of Interconnect for Equipment rack,and Speakers e.g Spikon CLR male female TRS Jack Etc and Speakers and other misc related work complete as per site requirement.
Supply install testing and commisioning (SITC) of 3-Way screen arry Speaker System High frequency driver is loaded with a 90° horizontal X 60° vertical waveguide with a 90° horizontal X 60° vertical large horn , horn must be horn can be vertically tilted by from 0° to 22.5° in increments of 2.5° to accurately achieve desired vertical coverage Frequency Response 45Hz to 20kHz Power Rating LF: 2000W AES, 8000W peak; MF: 500W AES, 2000W peak; HF: 80W AES, 450W peak Sensitivity MF: 105.5dB @ 1W/1m; HF: 113dB @ 1W/ 1m LF: 137dB continuous, 143dB peak @ 1m; Sound Prasure Level (SPL) MF: 132.5dB continuous, 138.5dB peak @ 1m; HF: 132dB continuous, 138dB peak @ 1m Nominal Impedance LF: 4Ω; MF: 8Ω; HF: 16Ω Low Frequency Driver 4 X 15″ (380 mm) weather resistant long excursion woofer Mid Frequency Driver 12” (300 mm) Low-Mid driver with coaxial entry High Frequency Driver 1.75” (44 mm) voice coil compression driver mounted coaxially Crossover 250Hz Active, 1.2kHz Active or Passive OEM aurtorization must be Required Make Pulz Audio Model Isowave D4 or techno commercial equivalent of Dolby SLS / Fidelity as approved by GE.
Supply install testing and commisioning (SITC) of 2X 18" multipurpus subwoofer system extends the usable range of any loudspeaker to 35Hz. power handling capacity of 2000W Frequency Response 35Hz to 200Hz Power Rating 2000W AES, 8000W peak Sensitivity 101dB @ 1W/1m Maximum SPL 134dB continuous, 140dB peak @ 1m Nominal Impedance 4Ω Transducers 2 X 18” (450 mm) long throw weather resistant woofer Grill Acoustically transparent perforated steel with foam backing SIC™ technology, increases bandwidth and efficiency while reducing total volume of vented bass loudspeaker by combining rear and front load in the same volume. OEM aurtorization must be Required Make Pulz Audio Model Esub218 or techno commercial equivalent of Dolby SLS / Fidelity as approved by GE.
Supply install testing and commisioning (SITC) of high sensitivity, high power 12″ full range driver Cinema Surround Speaker Frequency Response 100Hz to 18kHz Power Rating 250W AES, 750W peak Sensitivity 102dB @ 1W/1m Maximum SPL 126dB continuous, 132dB peak @ 1m Nominal Impedance 8Ω Transducers 12″ (300 mm) dual cone full range driver Dispersion 90° conical Grill Acoustically transparent black woven fabric it to be wall mounted with a 15° downward angle. Speakers must be included with OEM Hardware to achieve ±45° tilts in 9° increments. OEM aurtorization must be Required Make Pulz Audio Model DC12 or techno commercial equivalent of Dolby SLS / Fidelity as approved by GE.
Supply install testing and commisioning (SITC) of 2-Way Passive Speaker System The system consists of 2 X 12” low frequency driver in conjunction with 1.75″ voice coil high frequency driver Frequency Response 50Hz to 20kHz Power Rating 800W AES, 2400W peak Sensitivity 100dB @ 1W/1m Maximum SPL 127dB continuous, 133dB peak @ 1m Nominal Impedance 4Ω Low Frequency Driver 2 x 12″ (250 mm) weather resistant long throw woofer High Frequency Driver 1.75″ (44 mm) voice coil compression driver Crossover 1.2kHz Passive, low loss air core inductors and MKP capacitors Dispersion 90° horizontal X 40° vertical OEM aurtorization must be Required Make Pulz Audio Model EP2P or techno commercial equivalent of Dolby SLS / Fidelity as approved by GE.
Supply install testing and commisioning (SITC) of versatile Loudspeaker system must have passive 2-Way loudspeaker containing a 1.5″ voice coil compression driver assembled in a coaxial configuration Frequency Response 70Hz to 20kHz Power Rating 400W AES, 1600W peak Sensitivity 98dB @ 1W/1m Maximum SPL 124dB continuous, 130dB peak @ 1m Nominal Impedance 8Ω Low Frequency Driver 12″ (308 mm) Low-Mid driver with coaxial entry High Frequency Driver 1.5″ (38 mm) voice coil compression driver mounted coaxially Recommended Filter 60Hz 18dB/octave Butterworth high pass filter; 20kHz 18dB/octave Butterworth low pass filte OEM aurtorization must be Required Make Pulz Audio Model CX12 or techno commercial equivalent of Dolby SLS / Fidelity as approved by GE.
Supply install testing and commisioning (SITC) of four channel power amplifier bipolar output circuit combines Output Power (per channel) 4 X 820 Watts / 2 X 1560 Watts / 2 X 2100 Watts Frequency Response 30Hz –20kHz, ±0.2dB Total Harmonic Distortion + Noise <0.05%Intermodulation Distortion <0.02%Signal to Noise Ratio -95dB Damping factor >400 @ 8ΩCrosstalk -90dBSlew Rate 50V/us Input Sensitivity 1.4V RMS (+5dBu) nput Impedance 20kΩ, balanced Voltage Gain 32dB Bandwith 100kHz OEM aurtorization must be Required Make Pulz Audio Model PZ4820 or techno commercial equivalent of Ram audio/fidelity/Powersoft as approved by GE.
Supply install testing and commisioning (SITC) of two channel 3500 watt power amplifier with toroidal power supply and ultra – linear Class AB output stage amplifyer must be working on 16 oms / 8 oms / 4 oms / and all bridge mode also Frequency Response 20Hz – 20kHz, +0/-0.5dB Total Harmonic Distortion + Noise <0.1% Signal to Noise Ratio 110dB Damping factor >300 Crosstalk <-60dB Slew Rate >10V/us Input Sensitivity 0.7V, 1.4V Input Impedance 20kΩ, balanced Voltage Gain 38dB at 0.7V Sensitivity Protection Fuseless short circuit protection, ultrasonic and RF protection, thermal protection Load Protection Turn on delay, DC fault protection, Ultrasonic limiting OEM aurtorization must be Required of Make Pulz Audio Model AD21300 or techno commercial equivalent of Ram audio/fidelity/Powersoft as approved by GE.
Supply install testing and commisioning (SITC) of Digital Cinema Processor Dolby Surround 7.1 (D-cinema audio), 5.1 digital PCM (D-cinema audio), Dolby Digital Surround EX™ (bitstream), Dolby Digital (bitstream), Dolby Pro Logic® II, and Dolby Pro Logic decoding are all included to deliver the best in surround sound from all content sources for your single screen, multiplex, or large network. Eight-Channel Digital Input (4 × AES/EBU) for Digital Cinema Server: Includes support for Dolby Surround 7.1 Two Digital Pair Inputs (1 × AES/EBU): Connects alternative content sources (for example, preshow server, satellite receiver) Toslink™ Digital Input: Connects alternative content sources that output optical digital audio Eight-Channel Analog Input: Connects existing fi lm or alternative sound processor of Make - Dolby CP750 or techno commercial equivalent in / Emotiva / Cary audio
Supply install testing and commisioning (SITC) of 16-Channel Mixing Console: Max. 10 Mic / 16 Line Inputs (8 mono + 4 stereo) / 4 GROUP Buses + 1 Stereo Bus / 4 AUX (incl. FX)16-Channel Mixing Console Max. 10 Mic / 16 Line Inputs (8 mono + 4 stereo) 4 GROUP Buses + 1 Stereo Bus 4 AUX (incl. FX) “D-PRE” mic preamps with an inverted Darlington circuit 1-Knob compressors High-grade effects: SPX with 24 programs 24-bit/192kHz 2in/2out USB Audio functions Works with the iPad (2 or later) through the Apple iPad Camera Connection Kit / Lightning to USB Camera AdapterPAD switch on mono inputs +48V phantom power XLR balanced outputs Internal universal power supply for world-wide use Rack Mount Kit Included Metal chassis of Make -Yamaha MG16XU or techno commercial equivalent in / Soundcraft / Alen Heith / Presonus
Supply install testing and commisioning (SITC) of Corded Handhold Cardioid Dynamic Vocal Microphone with On/Off Switch Polar Pattern: Cardioid Frequency Response: 80Hz-15kHzOutput Impedance: 350 ohms Color: Black grille, gray body Connector: XLR Included Accessories: Mic clip Silent On/Off switch lets users discretely mute their own channel Hum-canceling coil rejects RFI interference Make - Sennisher E825S or techno commercial equivalent in / Clock Audio / beyerdynamic / Shure
Supply install testing and commisioning (SITC) of Gooseneck microphone with table top stand with ON/OFF Switch RF shielding against intermodulation from wireless devices Streamlined design for seamless integration Integrated light ring Impedance < 100 Ω Frequency response (microphone) 50 Hz - 20 kHz Transducer principle (Microphone) pre polarised condenser microphone Pick-up pattern cardioid Operating temperature 0 ... +40 °C Equivalent noise level 26 dB (A) Equivalent noise level weighted as per CCIR 468-3 37 dB Base Must Have Solid Microphone Stand Bi-colored light ring for clear visual feedback ogical function for easy control of e.g. cameras Toggle on/off Push to mute Push to talk permanent on (external LED control) Connector Logic: Clip contact for logic, Pin assignment: Trigger signal at logic connector: Logic in (external LED control), Ground, Logic out (switch signal) OEM aurtorization must submitted Make - Sennisher MEB14-40 or techno commercial equivalent in / Clock Audio / beyerdynamic / Shure
Supply install testing and commisioning (SITC) of 8500 Lumans Multipurpous Projection system must have Panel Type 0.65" DLPTM chip x 1 Lamp 420W UHM x 2 Brightness 8,500 lumens Lens F1.7-1.9, f25.6-35.7mm Contrast (Full on / Full off) 10,000:1 Resolution (Native / maximum) WXGA Screen Size 50" - 600" (100"-350" Lens Shift Vertical ±60°, horizontal ±10° ±30° Keystone Correction Range Vertical ±40°Terminals HDMI (19-pin x 1, Deep Color, compatible with HDCP) DVI-D (24-pin x 1, HDCP-compatible) RGB1&2 (D-sub HD 15-pin x 1, BNC x 5) 3D SYNC 1 (BNC x 1), 3D SYNC 2 (BNC x 1) Composite video (BNC x 1) Serial in (D-sub 9-pin x 1) out (D-sub 9-pin x 1) Remote 2 in/1out (M3x1, D-sub 9-pin x1 / M3x1) LAN/Digital Link (RJ-45 x 1) Make - Make - Panasonic DW830 or techno commercial equivalent in / Vivitek / Barcoor.
Supply install testing and commisioning (SITC) of 4K x 2K Full HD HDBaseT Extender HDMI Extender Over Single Cat 6 Ethernet Cable Long Range (100M) 3D 1080P Transmitter Receive Apply HDBaseT extend technology . Uncompressed HDMI video signal 3. Support full HD 1080p @ 60Hz, 3D 4Kx2K. Extend 1080p signal over Cat6 up to 100M. Support bi-directional IR pass back. Support HDCP, CEC, 24 deep colors. Support uncompressed LPCM audio and compressed DTS-HD Dolby True GD. Can be powered by network cable. It only needs to input 12V OEM aurtorization must submitted Make - Fidelity F-TXR22 or techno commercial equvivalent of / AMX / Atlona / Kramer
Supply install testing and commisioning (SITC) of high-performance seamless switching output and multi-format inputs 4x4 matrix switcher,4 multi-format inputs supports digital video signals and analog video signals Compliant HDMI1.3, HDCP1.3 and DVI1.0 Input video supports HDMI, VGA and C-video Supports output resolutions :1920x1080P@60Hz Input Ports 4×HDMI, 4xVGA, 4xRCA, 1 × RS-232, 1xRJ-45(Control), 5×IR INPUT, 4xAudio Output Ports 4×HDMI, 4xIR OUTPUT Control IR , RS-232 , TCP/TP , Buttons ESD Protection ± 8kV (Air-gap discharge) ± 4kV (Contact discharge) Supports smart EDID management Picture Adjustment Settings Automatically adjust the VGA input video Supports power-off memory OEM aurtorization must submitted Make Fidelity F-S44 or techno commercial equivalent in / MSW / Live connect / Perfect Path
Supply installation and fixing of matte white screen of maximum screen size possible on the stage having perfect matte white diffusing surface that ensures extremely broad light dispersion and spectral uniformity. The surface diffuses projected light in all directions, so the image can be seen from any angle with excellent colour reproduction Superb clarity Wide viewing angle Longer durability & easier maintenance Make -Fidelity Perl White / Harkness / Suvira / Elite / Big drapper
Supply install testing and commisioning (SITC) of 2.5 Sq MM High flexible Speaker cable for power amplifiers up to 1650 watts. To get such amouts of power to the loudspeaker without much signal energy loss, a conductor size of at least of 2.5 mm² per single core should be used.Jacket: Flameretarded PVC, Ø 8.0 mm, black Insulation: PVC, Ø 3.2 mm, black und red Conductor: (OFC) Stranded bare copper wires 140 x 0.15mm (2.50mm²) Flameretarded PVC Jacket (IEC 60332-3) OEM aurtorization must submitted Make - Gothem Cables / Fidelity / Belden / QED
Supply install testing and commisioning (SITC) of 4 Sq MM High flexible speaker cable for power amplifiers up to 2750 watts, Must Have Jacket PVC, ø 9.4 mm, black Insulation PVC, ø 3.9 mm, black and red Conductor Stranded bare copper wires, 7x (32 x 0.15 mm) (3.96 mm²) Center conductor resistance Capacitance cond/cond Insulation resistance Power rating Current max. < 4.65 Ohm /km < 180 nF /km > 200 MOhm /km 2750 Watt 24.0 Ampere Test voltage cond/cond Temperature range (flex)Temperature range (fix)Bending radius min.2000 V eff.- 5° to +50° C-30° to +70° C 5x overall diam. OEM aurtorization must submitted . Make - Gothem Cables / Fidelity / Belden / QED.
Supply install testing and commisioning (SITC) of 6 Sq MM Flexible Speaker cable for power amplifiers up to 4000 watts. 75 strands of 0.30 mm bare copper wires Jacket: FRNC compound , Ø 12.00mm, black Seperation viscose fiber coat Insulation: Polyolefin, Ø TBA, black and red Filler: cotton rope Conductor: (OFC) Stranded bare copper wires 75 x 0.30mm (6.00mm²) Conductor resistance: < 3.10 ohm/km Insulation resistance: > 200 M ohm/km Test voltage: cond/cond: 2000 veff Max. Operating Voltage 300V TemTemperature range: flexi-installed: -5° to +50° C fix-installed: -30° to +70° C Min. Bending Radius 5x overall diameter OEM aurtorization must submitted Make - Gothem Cables / Fidelity / Belden / QED.
Supply install testing and commisioning (SITC) of high Quality Signal Cable Jacket PVC, ø 8.80 mm, marine blue Shield No. 1 Bare copper wires (0.10 mm), 100% coverage Shield No. 2 Bare copper wires (0.10 mm), 100% coverage Layer Polyester nonwoven thermally bonded, both sides alum. coated Separation Filler material viscose Conductor shield layer Polyester nonwoven thermally bonded, both sides alum. coated Cond. copper shield Bare copper wires (0.10 mm), 100% coverage Isolation Cellular PE, ø 2.00 mm, 4 different colors Conductor Stranded bare LCOF copper wires, 64 x 0.10 mm (4x) (0.50 mm²) Make - Gothem Cables / Fidelity / Belden / QED
-----Blank-----
-----Blank-----
S & F 42 U Equipment Rack with Fan , Amp Rack , Cluster Wheel ,and Glassdoor Rack with 6 Socket PDU complete with all Accessories Make - Natrack / Rittel / Legrand / President
CURTAINS, WINGS AND FRILLS: -
Supply installation testing and commisioning (SITC) of Main Curtain made out of velvet curtain cloth 260 GSM (FR) with horizontal sliding arrangement complete with all fabrication work as per OEM instructions i.e.fixing rails, brackets sliding arrangement and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (crompton), 02 Nos air breaker contactors (LT/Siemens), 02 Nos micro switches for auto stop, 3 Nos push buttons for forward reverse and stop positions. The curtains should be draped to half area when in closed position, minimum overlap at centre should be 900mm and should be stitched in double gathering Appx size 12000x6000mm. The exact colour, pattern shall be as per interior arch as approved by GE. The exact size shall be as per OEM insturctions and as per site requirement to match with the size of stage. Make New Stage Craft or technocommercial equvivalent as approved by GE.
Supply installation testing and commisioning (SITC) of Center Curtain made out of velvet curtain cloth 260 GSM (FR) with horizontal sliding arrangement complete with all fabrication work as per OEM instructions i.e.fixing rails, brackets sliding arrangement and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton), 02 Nos air breaker contactor (LT/Siemens), 02 Nos micro switches for auto stop, 3 Nos push buttons for forward reverse and stop positions. The curtains should be draped to half area when in closed position, minimum overlap at centre should be 900mm and should be stitched in double gathering Appx size 12000x6000mm. The exact colour, pattern shall be as per interior arch as approved by GE. The exact size size shall be as per OEM insturctions, as per site requirement to match with the size of stage. Make New Stage Craft or technocommercial equvivalent as approved by GE.
Supply installation testing and commisioning (SITC) of rear curtain made out of glazed cotton cloth (FR) with horizontal sliding arrangement complete with fixing rails, brackets sliding arrangement and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP motor (Crompton), 02 Nos air breaker contactors (L&T/Siemens), 02 Nos micro switches for auto stop, 3 Nos push buttons for forward reverse and stop positions. The curtains should be draped to half area when in closed position, minimum overlap at centre should be 900mm and should be stitched in double gathering Appx size 12000x6000mm. The exact colour, pattern shall be as per interior arch as approved by GE. The exact size shall be as per OEM insturctions and as per site requirement to match with the size of stage. Make New Stage Craft or technocommercial equvivalent as approved by GE.
Supply installation testing and commisioning (SITC) of both revolving wings made out of black glazed cotton cloth (FR), fixed on 6mm thick commercial plywood fixed on side of MS 50mm x 25mm x 16 gauge GI pipe welded frame work. The pipe framwork made out of 25mm x 50mm pipe c/c 900x900 fixed with overhead pivot track complete with duly painted on both framework size 6000 x 2000. The exact colour, pattern shall be as per interior arch as approved by GE. The exact size size shall be as per OEM insturctions and as per site requirement to match with the size of stage. Make New Stage Craft or technocommercial equvivalent as approved by GE.
Supply installation testing and commisioning (SITC) of average frills. frills made out of double gathering glazed cotton cloth (FR) to be installed above the stage on 28mm dia MS pipe size 12000 (AV) x 1800. The exact colour, pattern shall be as per interior arch as approved by GE. The exact size shall be as per OEM insturctions and as per site requirement to match with the size of stage. Make New Stage Craft or technocommercial equvivalent as approved by GE.
FIRE FIGHTING, FIRE DETECTION AND ALARM
S & F gunmetal type double outlet landing valve (double headed hydrant valve) having 80 NB flanged inlet, brass spindle controlled 63 mm diameter female instantaneous outlet type gunmetal coupling, blank cap, chain, twist release type lug, etc., conforming to IS: 5290- 1993 (type A), including fixing with anchor fastner and flanged tapping from downcomer complete all as specified and directed. [Make: New Age/Shah Bhogilal (AAAG)]
M & L for FRLS type, PVC insulated, ST-2 PVC outer sheath, multi strand copper conductor armoured cable, RED in colour, including fixing with GI saddles spacing 300 mm, compression glands, lugs, etc. complete as specified and directed. [Make: RR/Polycab/Havells] of following sizes: -
2 core 1.50 sqmm
2 Core 2.50 Sq mm
S & F 6.0 kg dry chemical powder (ABC) type portable fire extinguisher having features viz., fire rating 3A:21B, average discharge time 21 s, operating temperature -30- 55° C, maximum service pressure 18 bar, including fixing complete all as specified and directed. [Make: Ceasefire/Minimax/SAFEX]
S & F 4.5 kg carbon dioxide type portable fire extinguisher having features viz., fire rating 13B, average discharge time 14 s, approximate height 545 mm, approximate diameter 140 +/-10 mm, approximate filled weight 12.5 kg, approximate empty weight 8.00 kg, operating temperature -30- 55° C, maximum service pressure 110 bar, complete all as specified and directed. [Make: Ceasefire/Minimax/SAFEX]
SUMMER APPLIANCES:
Supply and fix voltage stabilizer for automatic operation, air cooled, indoor type & designed for input variation between 130V to 280V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 1 KVA complete all as specified and as directed.
Supply and install water purifiers suitable for mounting on wall for water coolers working as RO + UV + UF + TDS control technology with water purifier capacity capacity of 15 ltr/hrs with input voltage 230 V AC, 50 Hz as specified and directed. Make : Eureka Frobs or Equivalent in KENT or Livpure all as specified. The model shall be as approved by GE.
AIR CONDITIONING
Supply, installation, testing and commissioning of factory designed, Scroll type water-cooled chiller Make: Bluestar/Carrier/Voltas suitable for ambient environmental conditions having actual capacity not less than 39 TR, pre-fabricated and floor-mounted, water vapour compression, scroll type water-cooled chiller machine complete with semi-hermatic scroll compressors with independent refrigerant circuits, water-cooled S/T type condenser, S/T horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with elastomeric insulation, common base frame, interconnected copper refrigerant piping and wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly, CFC-free refrigerant gas R407C/R410A all complete as specified and directed.
The rates for above item shall be inclusive of a unit mounted star-delta starter in accordance with site parameters,victaulic coupling and system integrator capable of giving industry standard (modbus/bacnet) output to BMS for critical parameters, etc. Mapping shall be required for all critical points displayed on the chiller control panel. The chiller shall be BMS compatible and shall have RS485/RS232 serial communication protocol; the motor shall be suitable for 3- Phase, 415 V ± 10%, 50 Hz AC electric supply; electric panel shall have an IP 54 rating. Necessary civil work viz. foundation for placement of chillers shall be covered in the scope of work. The chiller shall be as per the approved particular technical specifications and shall meet the following design criteria: [a] Local ambient temperature: 104°F [b] Chilled water leaving temperature: 44 ⁰F [c] Chilled water entering temperature: 54 ⁰F [d] Evaporator fouling factor: 0.00025 ⁰Fft²hr/Btu [e] IKW/TR: Not exceeding 0.85 [f] Refrigerant (Ozone friendly type): R407C/410A/ [g] Minimum COP required 4.7 [h] Flow Rate: chilled water- 2.46 USgpm/TR; condenser water- 4.0 USgpm/TR Make: Bluestar/Carrier/Voltas
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type pump Monoblock type centrifugal pump suitable for 5.75 LPS water flow and 12 MWC head along with elastomeric insulation.having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, elastomeric insulation, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed.Necessary civil work viz. foundation for placement of pump, mounting of star-delta starter panel and pump accessories shall be covered in the scope of work. Make: Kirloskar or techno commercial equvivalent
Supply, installation, testing and commissioning of FRP rectanguler shape, FRP bottle shape induced draught cooling tower suitable for 80 TR AC Plant capacity vertical, induced draught counter flow cooling tower with uniform water distribution and optimal heat transfer, having tough fiberglass reinforced plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, TEFC squirrel cage high efficiency induction motor with IP 65 protection, inlet, outlet, drain and over-flow nozzle connections, etc. suitable for 3- Phase, 415 ± 10% V, 50 Hz AC electric supply complete all as specified and directed. Necessary civil work viz. foundation, supporting structure, etc. for placement of cooling tower shall be covered in the scope of work. Make:Delta / Advance
Supply, installation, testing and commissioning of monoblock, self-priming, single-stage, centrifugal volute type suitable for 10.7 LPS water flow and 14 MWC head.pump having cast iron casing, enclosed type dynamically balanced phosphor-bronze/SS impeller, high tensile steel shaft, carbon steel stuffing box (sealed by mechanical seal), deep groove ball bearings, TEFC squirrel cage induction motor having IE- 3 efficiency and conforming to IS: 12615- 2018, base plate, mounting channel frame, accessories and fittings, viz. mechanical seal, pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting suitable for operation on 3- Phase, 415 V ± 10%, 50 Hz AC supply complete all as specified and directed. Necessary civil work viz. foundation for placement of pump, mounting of stae-delta starter panel and pump accessories shall be covered in the scope of work. Make: Kirloskar or equvivalent
Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side, discharge 13000 CFM; 75 mm WG static pressure AIR HANDLING UNIT Make: Bluestar/Carrier/Voltas having corrosion resistant extruded aluminum hollow profile with thermal break, 16 gauge galvanized steel channel base frame, 43 mm thick double skin panel with pressure injected CFC & HCFC free PUF having 'k' value of 0.02 W/°C/m & density 40 kg/m³ pre-coated, pre-plasticized, galvanized outer and inner skin 0.60 mm thick, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet, double width forward or backward curved impellers for high static pressure mounted on aluminum extruded siderail base frame, combination of 6 rows deep chilled water coils with anti-corrosion aluminum fins, combination of 2 rows deep hot water coils with anti-corrosion aluminum fins PVC/naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, 10 micron pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers complete all as specified and directed. The AHU shall comprise of the following:
[a] Suitable DIDW fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply [c] V-belt drive assembly with pulleys, belt, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, filters, fixing framework, hinge type access doors, etc. [e] 6 row deep chilled water coil section with copper fins and copper tube tested on 21 kg/cm² with SS sandwiched drain tray, etc. [f] AHU panel made out of 2.00 mm thick mild steel CRCA sheet, duly powder coated, in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor, etc. complete with required variable frequency drive (VFD), relays, timers, contactors, PT, push buttons, switches, internal wiring, etc. [g] Along with strip heater having 6 Nos. of 2 kw.Necessary civil work viz. foundation for placement of AHU, mounting of variable frequency drive (VFD) panel, construction of opening(s) for fresh/exhaust air etc. shall be covered in the scope of work. Make: Bluestar/Carrier/Voltas
S & F SS- 304 closed expansion tank 200 Ltr capacity of pressure rating to suit the system pressure and sized adequately to compensate for water expansion due to operating temperature variations, conforming to IS: 2825- 1969 for 'non-fired pressure vessels' complete with inter-connection piping, non-return valve, safety relief valve and pressure gauge, insulated with 50 mm thick elastomeric insulation and cladded with 26 gauge aluminium sheet complete all as specified and directed.
S & F triple HDPE storage tank 5000 ltrs capacity made up of 100% virgin material, having 100% UV stabilized white outer layer, threaded lid, extra insert lid for protection against algae formation complete with inter-connection piping and non-return valve etc. complete all as specified and directed.
Supply, installation, testing and commissioning of PN 1.6 rated POT strainer, 100 mm NB tested as per BS 6755 (Part- I), suitable high capacity flow throughout full size inlet/outlet, having CI body & strainer bonnet, stainless steel perforated filter screen, black rubber body/bonnet gasket, SS- 410 ball valve and flange drilling standard end connection, etc. complete all as specified and directed.Make: Sant & Sbm Or Zoloto
Supply, installation, testing & commissioning of Y-type strainer 65 mm NB with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. with accessories complete all as specified and directed. Make: Sant & Sbm Or Zoloto
Supply, installation, testing & commissioning of Y-type strainer 50 mm NB with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets and flange drilling standard end connection, etc. with accessories complete all as specified and directed. Make: Sant cat part No. CI16B or techno commercial equvivalent of Sbm Or Zoloto
Supply, installation, testing and commissioning of manual balancing valve, Body: CI 260 (GG 25)/DI, Bonnet: CI 260 (GG 25)/DI IS 1865 Gr. 450/10, Hand wheel: CI 220 / WCB / M.S., stem: SS 410/431, Lower Disc: SS 410, Upper Disc: SS 410, Body/Bonnet Gasket: CAF, Body/Bonnet Bolts: A 307 Gr. B, Gland Packing: Graphited Asbestos, conforming to BS 7350 of following sizes complete all as specified and directed. Make: Sant & Sbm Or Zoloto
100 mm NB Make sant cat part no. CIBV
80 mm NB Make sant cat part no. CIBV
50 mm NB Sant cat part No. SBBV
Supply, installation, testing and commissioning of paddle type water flow switch, having operating pressure 1000 kPa, withstand pressure 91750 kPa, insulation resistance over 100 Ω, withstand voltage 1500 V AC for 1 minute, contact point life of 1000 k cycles and bellows life 500 k cycles complete with control wiring and accessories, etc. complete of following sizes , all as specified and directed. Make: Sant & Sbm Or Zoloto
Supplying, laying/fixing, testing and commissioning of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with FM approved closed-cell elastomeric foam material of appropriate thickness covered with 230 micron thick double layer laminate of aluminium, coated with a special UV protection and PVC backing, having service temperature range 0 to110 ⁰C, thermal conductivity ≤ 0.039 W/mK at 40 ⁰C and class 0 fire performance, conforming to BS 476 (Part- 7): 1997, as per specifications and as required. NOTE: The pipes of sizes 150 mm NB & below shall be M.S. ‘C’ class as per IS 1239 (Part- 1): 2004 and pipes size above 150 mm NB shall be welded black steel pipe heavy class as per IS: 3589: 2001, from minimum 6.35 mm thick M.S. sheet for pipes upto 350 mm NB and from minimum 7 mm thick MS sheet for pipes of 400 mm NB and above. Make: Tata or Jindal of following sizes
Supply, installation, testing and commissioning of CI 3-way mixing valve, of size 50 mm NB suitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation complete all as specified and directed.Make: Sant & SBM Or Zoloto
S & F of CL 150 # rated 25 mm NB ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories complete all as specified and directed. Make: Sant & SBM Or Zoloto
Supply, installation, testing and commissioning of automatic air-vent valve with 19 mm end connections with Brass OT 58 body and cover, polyacetal lever, high density expanded polyethylene float, EPDM rubber plug, stainless steel spring, polyamide cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 115° C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed. Make: Sant cat part No. AV or technocommercial equvivalent of Sbm Or Zoloto
Supply, installation, testing and commissioning of glycerin filled bimetallic thermometer, temperature gauge of 150 mm dial size for temperature range 0° C to 100° C in compliance to EN 13190, having standard range 0° C to 60° C up to 400° C, IP 67 protection, bimetal coil sensing element, accuracy class 1 as per EN 13190, stainless steel casing, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 stem and connection, aluminum dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), toughened glass window, neoprene filling plug and gasket complete with accessories, etc. complete all as specified and directed.Make:Baumer or techno commercial equvivalent
Supply, installation, testing and commissioning of glycerin filled pressure gauge Pressure gauge of 100 mm dial size for pressure range 0 psi to 200 psi in compliance to EN837-1, having standard range 15 to 0 psi and 16 psi to 10000 psi, IP 67 protection, accuracy class ±1.6% of FS, stainless steel casing and TIG argon welded socket to case, direct bottom mounted, SS- 304 case and bayonet type bezel, SS- 316 bourdon, socket, SS dial (white background with black marking) & pointer (black colour micrometer with zero adjustable), polycarbonate glass window, neoprene blow off disc and filling plug, silicon gasket complete with accessories, etc. complete all as specified and directed. Make:Baumer or techno commercial equvivalent
Supply, installation, testing and commissioning of pre-fabricated, galvanized steel sheet (G.S.S.) square/rectangular ducting for supply/return air, fabricated from galvanized steel sheet, having zinc coating of 160 g/m² total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. conforming to per IS 655:1963 along with required scaffolding work to install the ducts at site complete all as specified and directed of following thickness. The quoted rates shall include for fixing arrangement for ducting under truss, or wall, ar at any other location as per standard engineering practice and as directed by GE.Make TATA or JINDAL
24 Gauge (MS angle flanges)
22 Gauge (MS angle flanges)
Supply, installation, testing and commissioning of fire damper complete with smoke detector/thermister, fusible link etc. and actuator as required for operation. The fire dampers shall be spring activated on melting of fusible link having melting point 67.13° C. The fire damper shall be located in the SA/RA ducts, at all fire rated crossoevers (shafts, walls, etc.). The control panel shall be located in such a way that the reset can easily be done. These combination smoke and fire dampers shall be interlocked with the building management system for the fire detection or HVAC and shall trip/close in the event of fire/smoke in the respective zone. Fire damper shall be tested as per ULL- 555 and certified by CBRI. The fire-damper shall be of at least 120 minutes fire-rating complete all as specified and directed.The fire dampers shall meet the following criteria: [a] Bare fire dampers with 400 mm sleeve, [b] ----Blank--- [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers, [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer, Motorized, spring return type, combination fire and smoke damper
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
S & F closed cell elastomeric nitrile rubber insulation with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 kg/m³. The insulation material shall be FM (Factory Mutual) USA approved and dust & fibre free. The Aluminium foil shall be 60 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 mm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3 of following thickness , complete all as specified and directed. Make:Armacell or techno commercial equvivalent of aeroforam and allied insulation.
13 mm thick nitrile rubber thermal insulation
9 mm thick nitrile rubber thermal insulation
Supply, installation, testing & commissioning of removable supply air jet diffusers, return air grilles/louvers of extruded aluminum sections duly powder coated with volume control damper complete all as specified and directed.Make: Ruskin Titus or techno commercial equvivalent in aroma or hubmar SA jet diffusers, RA grilles/louvers with volume control damper all as specified.
Supply, installation, commissioning and testing of factory made, CPRI type tested, outdoor, cubical compartmental type "HVAC Panel" of suitable size, conforming to IEC 61439-1 &2, IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 3.15 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete all as specified and directed. The HVAC Panel shall comprise of copper bus bar of rated capacity 500 Amps covered with PVC insulated sleeves including insulator, nuts, bolts etc. wuth complete connection-1 set and the following, incoming and outgoing:
Incoming: [i] 250 A, 415 V, Ics = Icu = 36 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable overload settings (0.40- 1 X In) & tr = 0.5 - 16 s, adjustable short-circuit settings (1.5 - 10 X Ir), adjustabble neutral protection, adjustable earth- fault settings (0.2- 1 X In), instanteneous protection and microprocessor based trip unit- 01 Nos. [for chillers] [ii] LED phase indicators (Red, Yellow, Blue)- 01 Set [iii] Power Quality analyzer with revenue accuracy of Class 0.2S, complying to IEC 62053- 22, 256 samples/cycle, waveform reading, 512 MB of standard non-volatile memory for data & event logging, up to 63rd harmonics analysis for voltage & current, GPS clock, 01 serial port (Modbus, ION, DNP3), Dual Ethernet port (Modbus/TCP, ION TCP, DNP3 TCP, IEC 61850) and standard digital input, expandable digital IO, analog IO.- 01 Nos.
Outgoing : [i] 125 A, 415 V, Ics = Icu = 25 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable overload settings (0.40- 1 X In) & tr = 0.5 - 16 s, adjustable short-circuit settings (1.5 - 10 X Ir), adjustabble neutral protection, adjustable earth- fault settings (0.2- 1 X In), instanteneous protection and microprocessor based trip unit- 01 Nos. [for chillers] [ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. [for AHU] [iii] 63 A, Icn = 10 kA, 415 V, 50 Hz, FP MCB (C- curve)- 5 Nos. [for chilled water pump, condenser water pump and cooling tower] [iv] 32 A, 230 V, 50 Hz, SPN MCB (C- curve)- 01 Nos. [for AC Plant Room] [v] LED phase indicators (Red, Yellow, Blue)- 8 Set [vi] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 8 Nos.
M & L for Earthing complete with Copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
NOTES :- (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 M earth lead wire. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
ENTRY AND EXIT LIGHTING
Supply, installation, testing of fire exit sinage and fire entry signage with LED and battery back up and charger with hanging arrangement including testing and commisioning on completion all as specified and directed as per make Bajaj Cat part No. 220208 BESL 03 LED SSD WBB GREEN or techno comeercial equvivalent in Havells /Wipro. .
Supply, installation, testing of MCB districbution board powder coated CRCA sheet constructed as per IS-86223, degree of protection IP-43-IK-09with metal door, recess mounted having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, DIN bar, detachable gland plate, interconnection, earthing connection, blanking plates inunused spaces as required SPN240 Volts 2 way complete.
OPERATION OF CENTRAL AC PLANT
Provision of services for operation of HVAC plants installed at Auditorium including including all equipments such as chillers, condensors, all type of pumps and motors, panels, cooling towers, AHU, insulating ducts, fans and all types of valves etc. in for 08 hours on each day, including sundays/holidays, for one year from the certified date of completion of work under the Ph-I by deploying one number technically qualified technical tradesman as approved, specified and directed by the GE. Note: - The working hours and time table for the duration of shift required shall be as decided by the GE fortnight basis in advance as per operational requirement. No claim whatsoever shall be entertained incase of increase/decrese in shifts on any day.
Provision of services for operation of HVAC plants installed at Auditorium including including all equipments such as chillers, condensors, all type of pumps and motors, panels, cooling towers, AHU, insulating ducts, fans and all types of valves etc. in for 08 hours on each day, including sundays/holidays, for SECOND YEAR from the certified date of completion of work under the Ph-I by deploying one number technically qualified technical tradesman as approved, specified and directed by the GE. Note: - The working hours and time table for the duration of shift required shall be as decided by the GE fortnight basis in advance as per operational requirement. No claim whatsoever shall be entertained incase of increase/decrese in shifts on any day.
Notes for operation of AC Plants: -(a) the contractor shall employ one operator per shift. (b) The operator shall be qualififed and experienced in field with experience not less than two years. (c) Cost of periodical maintanance of various equip,ments/parts shall be deemed to be included in the unit rates quoted. (d) Desired temperature should be maintained strictly. (e) The contracor shall follow the operation and maintanance of manual of the plant. (f) Periodical cleaning and maint including removal of algae from the cooling tower. (g) To clean the area in presentable manner in and around the plant room. (h) To maintain the log sheet as per format provided by the Engineer-in-charge. (j) The shift hours chart for every month shall be as decided by the GE. However contractor is bound to provide the operator as when called for as per ground requirment at short notice by the GE. No claim whatsoever shall be entertained on this account. (k) Penal recovery: -In case if operator is found absent or missing from duty the alternate arrangement shall be made by the GE with intimation to the contractor. Under such circumstances the recovery at double the quoted rate shall be recovered from the contractor's payments.
ARBORICULTURE: - Supply and planting of below mentioned trees in 0.25- 0.3M poly bags with height 1.5 M to 1.8 Mtr incl digging holes 1.2M dia x 1.2 Mtr deep in ordinary soil and reffiling the same with the excavated earth mixed with manure or sluldge in the ratio 2;1 (02 parts of stacked volume of earth after reduction of 20% with 1 parts of stacked volume of sludge of manure after reduction by 80% flooding with water and removed of surplus soil and rate inclu maintaining the plants for 2 years :-
SHADDY/ ORNAMENTAL PLANTS:-
Casoraina
Canarydate palm
Amaltas
Gulmohar
Kesia
Kamuj
Ashoka
Silver Palms
Arica Palms
Phicus
Exugora dwarf
Golden Bamboo
Eucalyptus
FRUIT BEARING PLANT :-
Mango
Goava
Jamun
Sitaphal
Cheeku
FLOWER/ FRAGMENT PLANTS:-
Jasmine
Alortonia
Bottle Brush
Bugenella
Battle Nut
NOTE for Sl Item No 152 .01 TO 152.30:- (i) Height of plant shall be measured from top of follage ( not from the isolated branch/leaf,main stem) to 150mm from top of root. (ii) Water will not be supplied by MES. Contractor has to make his own arrangement for watering to plants. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants till two years after certified date of completion of work. (iv). During two years after completion if any plant is found dead, or not of satisfactory growth, plants of approved size and shape shall be provided without any extra cost to the state. (v). Supply and application of manure, sweet earth and pesticides, fertilizers, etc up to two years after completion of Ph-I are deemed to be included in the quoted unit rate. (vi) The plants shall be brought at site Six months before the date of completion of the work or as directed by GE.
M K ENGINEERS CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .