Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC HALISAHAR NATUNPARA NORTH 24 PARGANAS | HALISAHAR | NORTH 24 PARGANAS | WEST BENGAL | 743135 | L1 | Accepted-AOC AOC | |
| 2 | L2₹7.8 L+₹70,917 (9.94%)Rejected-Finance 1 39 VIVEKANANDA PARK 291 NEW SHIBTALA ROAD BANSDRONI KOLKATA 700070 | KOLKATA | KOLKATA | WEST BENGAL | 700070 | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹7.9 L+₹75,135.99 (10.5%)Rejected-Finance 10 WATARLOO STREET KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | L3 | Rejected-Finance HIGHER BID | |
| 4 | L4₹7.9 L+₹76,781.10 (10.8%)Rejected-Finance 487 A 1 GOPAL MISHRA ROAD BEHALA KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L4 | Rejected-Finance HIGHER BID |
Tender Value
₹7.9 L
EMD Value
₹15,815
Closing Date
3 Sept 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE/KNED, PWD
P-5 CIT Road, Kolkata700014
Supply, Erection, Testing and Commissioning of Street Lighting System for Illumination of the new Bagjola Bridge on Dum Dum Road
2024_WBPWD_728498_1
WBPWD/EE/KNED/eNIT15/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
new Bagjola Bridge on Dum Dum Road
Please refer tender documents
7 documents required · 7 mandatory
₹15,815
Kolkata North Electrical Division, PWD
13 Jan 2025
6 Aug 2024
5 Sept 2024
6 Aug 2024
3 Sept 2024
13 Aug 2024
12 Aug 2024
Amount
Supply of 7.00 mtr long Single Swan Neck MS Swaged Type Steel Tubular Pole With In-Built Junction Box as per 410-SP 01 of IS:2713/86 with Base Plate and 1 no 6A SPMCB as regard including all necessary arrangement as per direction.
Supply of 7.00 mtr long Double Swan Neck MS Swaged Type Steel Tubular Pole With In-Built Junction Box as per 410-SP 01 of IS:2713/86 with Base Plate and 1 no 6A SPMCB as regard including all necessary arrangement as per direction.
Supply,fabrication and fixing of MS Clamp suitable for the fixing the ST pole with Box type iron structure having below specification: Metal-Mild Steel. Inside gap -100 mm, Total length -1200 mm, Thickness-6 mm, Paint-2 coat of matching paint with existing railing including 2 coat of RO primer, Approx Weight- 2 kg, The above clamp to be fixed with 4 nos of suitable size SS Bolt,Nut and washer as per direction of EIC.
Supply,fabrication and fixing of "L" Shaped MS plate to be fixed with existing iron structure by welding method with necessary arrangement as require. The L shape plate size will be 150 mm X 600 mm, 10 mm thick , aprox weight-3 kg. The plate to be welded such a way so that the weight of the pole to be wistand partlly.The design to be approved by EIC.
Supply & delivery of 250V, 120W (Maximum) LED street light (CT- 5700K-6000K) with IP-66, individual Secondary Optics Peanut Lens and Separate Toughned Glass Diffuser, Potted Driver to be used output fittings & Efficacy > 120 LPW, as directed by EIC. Fittings should be included of -i) 4 KV internal & 10 KV external SPD ii)Driver wattage should be greater than or equal to ratted fitting wattage) [Make:wipro- DOT ,cat-LR08-132-XXX-57-XX /equivalent spec of Lighting Technology(LT) / Philips] .
Supply Wiring by 3 core 2.5 sqmm PVC insulated flexible cables(FRLSH) from loop box to fitting as per GS. [Make-Finolex/KEI/Havells/Polycab/Gloster]
Supply & Delivery of 1.1 kv grade 2Cx10 sqmm XLPE-armoured AL. cable, as directed by EIC. [Make-Finolex/KEI/Havells/Polycab/Gloster]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below a) 2 core 10 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials a) 2 core 10 sqmm
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support. 200x50x1.25mm (18SWG)
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.(Upto 50sq mm)
Supplying of 80 mm dia HDPE PIPES pe 63, 4kgf/cm2 type-SDR-21, ( For laying different cables) Make- Supreme/Oriplast/similar make
Excavation of soil and laying HDPE/GI Pipe for cable laying filling & ramming. (0.150x0.450xTotal Length of pipe laying (WxDxL)
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe
Excavation of soil for installation of earth electrode
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages, Solid GI wire No. 4 SWG.
Supply ,delivery & Commissioning of L.T. hooder type Double door Feeder Pillar box of size ( minimum 1200X900X800) mm should be suitable for the bellow descriptions and approved by EIC, with canopy Floor mounted with maple arrangement having rigid & self supporting structure fabricated from 3mm. thick CRCA sheet steel with M/S angle frame. The panel board consisting of the following switches. A) Incoming Section - 63A TPN SFU with 3nos Fuse Link-1 no; B) Outgoing - 32A TPN SFU and 3nos Fuse Link-- 3 Nos ( 2 Working + 1 Spare) For Front Side & 1 no 63 A SFU with 3 nos fuse link and 4 nos 63 A kitkat fuse for Backside CESC connection . (Make: Legrand/L&T/CRABTREE/Havells/ABB) Bus Bar Section: 500 V, 100 A. electrolyte grade Copper bus bar with vertical/ horizontal section of size 15 x 05 mm for per Phase RYB, & 15 x 05 mm for neutral bars. Bus bar should be enclosed by sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on inside feeder pillar, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991). Bar for earth 25x6 Al. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. including RYB, indication Lamp, , 6A FPMCB- 3 nos, ,
Painting. Paint will be powder coated, After cleaning, the surface shall be given a phosphate coating, nine tank process system, SIEMENS GREY, RAL-7035 Shed Constructural Details: All incoming & outgoing panel gasketted Door at front. All doors shall have Panel lock Arrangement. Degree of Protection will be IP-56(Protected from high pressure water jets from any direction) .The panel shall be properly Gasketted to prevent ingress of dust & moisture & Remain. Busbar will be properly arrange & fixed by M.S. nuts & bolts On angle /flat iron frame base as per direction of E.I.C. The PANEL will be fabricated by 14 SWG. CRCA Sheet. The sheet steel thickness will be 2mm & Gland plate shall be 2/3mm thick. The work is inclusive of erection of Feeder Piller Box of above size on 10" brick padestal of 10" size should be appropriate according to the above Feeder Pillar and dimensions of the same approved be the EIC (minimum height 600mm bellow Goround level and 600mm above G.L) incl.sand cement plastering and neat cement finishing. Inside the brick padestalwill be filled up by loose sand where the incoming & outgoing cable will be rest. ** Back side of the feder piller will be used for CESC service connection
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for Installation of Cable Tray and other works through out the bridge (outer side) (both side of the bridge)
Note: 1) All the above rates should be quoted inclusive of all taxes & duties and LWC as applicable. 2) Total is rounded off to the nearest rupees.
BIKASH ENTERPRISE (BID ID -5441579)
S. K. CHATTERJEE ELECTRICALS PVT LTD (BID ID -5508373)
STAR ENTERPRISE (BID ID -5486405)
technical_1606683.pdf
PDF • 0.28 MB
techsummary_1606683.pdf
PDF • 0.33 MB
finance_1606683.pdf
PDF • 0.36 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1606683.pdf
PDF • 0.28 MB
FINAL15.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .