Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAdmitted-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹27.7 L | L1 | Admitted-Finance |
| 2 | L2₹28.4 L+₹65,315 (2.36%)Admitted-Finance 379 B FIRST FLOOR CHIRAG DELHI NEW DELHI 110017 | NEW DELHI | SOUTH DELHI | DELHI | 110017 | ₹28.4 L+₹65,315 (2.36%) | L2 | Admitted-Finance |
| 3 | L3₹31.9 L+₹4.2 L (15.2%)Admitted-Finance | ₹31.9 L+₹4.2 L (15.2%) | L3 | Admitted-Finance |
| 4 | L4₹34.6 L+₹6.8 L (24.7%)Admitted-Finance | ₹34.6 L+₹6.8 L (24.7%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical 26 2 BHASKAR CIRCLE RATANADA JODHPUR RAJASTHAN 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | - | - | Rejected-Technical Documents not submitted as per tender conditions |
| Sl No | Description | Qty | Unit | NIRMAN ELECTRIC STORE L3 | VOLKS ENERGIE PVT LTD L1 | Halcyon Technologies L4 | AIR DESIGN SOLUTIONS L2 |
|---|---|---|---|---|---|---|---|
| 1.00Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type single/twin Rotary/Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building For Cooling or Heating or Both , MS Stand with vibration isolators, necessary accessories and top up of refrigerant gas at site. | |||||||
| 1.01 | 14 HP single/dual compressor Module | 1 | each | 3,10,320 ₹3,10,320 Lowest | 5,38,000 ₹5,38,000 | 3,24,686 ₹3,24,686 | 3,35,500 ₹3,35,500 |
| 1.02 | 16 HP single/dual compressor Module | 1 | each | 3,18,720 ₹3,18,720 Lowest | 6,00,000 ₹6,00,000 | 3,68,144 ₹3,68,144 | 3,65,000 ₹3,65,000 |
| 2.00Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor) (Compact Cassette= 2x2 ft.) | |||||||
| 2.01 | 1.2 TR | 4 | Each | 36,500 ₹1,46,000 | 35,000 ₹1,40,000 Lowest | 35,442 ₹1,41,768 | 38,000 ₹1,52,000 |
| 2.02 | 1.6 TR | 11 | Each | 37,500 ₹4,12,500 | 38,000 ₹4,18,000 | 36,764 ₹4,04,404 Lowest | 39,000 ₹4,29,000 |
| 2.03 | 1.8 TR | 2 | Each | 40,450 ₹80,900 | 40,000 ₹80,000 | 37,628 ₹75,256 Lowest | 42,000 ₹84,000 |
| 3.00 | Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints for Indoor Units. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs | 15 | Each | 5,100 ₹76,500 | 2,500 ₹37,500 Lowest | 6,000 ₹90,000 | 4,000 ₹60,000 |
| 4.00Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||||
| 4.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 70 | Mtr | 580 ₹40,600 | 300 ₹21,000 Lowest | 378 ₹26,460 | 361 ₹25,270 |
Tender Value
₹33.7 L
EMD Value
₹1.0 L
Closing Date
6 Aug 2026, 6:00 pmClosed
Sr. Manager Engg Electrical
Senior Manager Engg Electrical, AAI Jodhpur Airport.
SITC of air cooled VRF outdoor units. VRF indoor units and controlled work. Refrigerant piping and drain piping. Electrical work for VRF system. Other Miscellaneous works as per direction of EIC
2026_AAI_284435_1
AAI/JOD/ENGG (E)/166/2026-27
Open Tender
Electrical Works
Item Rate
60 days
JODHPUR AIRPORT
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
₹1.0 L
14 Aug 2026
17 Jul 2026
8 Aug 2026
17 Jul 2026
6 Aug 2026
17 Jul 2026
17 Jul 2026 - 20 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type single/twin Rotary/Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building For Cooling or Heating or Both , MS Stand with vibration isolators, necessary accessories and top up of refrigerant gas at site. | |||||
| 1.01 | 14 HP single/dual compressor Module | 1 | each | - | - |
| 1.02 | 16 HP single/dual compressor Module | 1 | each | - | - |
| 2Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 °C DB and 19 °C WB temperature. (Make will be same as of Outdoor) (Compact Cassette= 2x2 ft.) | |||||
| 2.01 | 1.2 TR | 4 | Each | - | - |
| 2.02 | 1.6 TR | 11 | Each | - | - |
| 2.03 | 1.8 TR | 2 | Each | - | - |
| 3 | Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints for Indoor Units. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs | 15 | Each | - | - |
| 4Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | |||||
| 4.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 70 | Mtr | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.64 MB
BOQ_332047.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .