Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAdmitted-Finance NO14 MSF BUILDING NO 14 2 FLOOR MSF BUILDING OPP CHURCH BYE PASS JUNCTION AROOR P O ALAPPUZHA DIST KER ALLAPUZHA KERALA | L1 | Admitted-Finance | |
| 2 | L2₹5.9 L+₹11,255 (1.93%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Veejay Technologies L1 | 3M ELECTRONIC SAFETY SYSTEMS L2 |
|---|---|---|---|---|---|
| 1.00Installation and configuration of CCTV Camera & Networking System at NP Plant conveyor areas, Phase-II at FACT-CD. | |||||
| 1.01 | Supply & laying of Armoured CAT6 cable inside HDPE conduit (32mm/20mm).
The work includes supply of CAT6 Armoured cable and laying the same overhead through HDPE conduit. Any route taken above ground viz. on compound walls or along steel girders or structural or cable ducts or cables tray shall be considered as overhead route. After laying, the conduit shall be properly tied/fixed using proper aluminium clamps/cleats so that any kind of hanging /sagging shall be avoided. Breaking the wall/floor drilling holes to fix the clamps/ installing the conduit, laying the cable and plastering the wall shall be done by the contractor as required. Metal steel tags shall be used for identification of OFC/Cat 6 cables laid through overhead routes.
Bidder shall supply and use the CAT6 cable as per Annexure IIIA. Other materials like aluminium clamps/ cleats and metal tag required for the work shall also be supplied by the bidder. | 705 | M | 56,400 ₹56,400 Lowest | 66,975 ₹66,975 |
| 1.02 | Supply & laying of OFC 6core cable inside HDPE conduit (32mm/20mm).
The work includes supply of OFC 6core cable and laying the same over head through HDPE conduit. Any route taken above ground viz. on compound walls or along steel girders or structural or cable ducts or cables tray shall be considered as overhead route. After laying the conduit shall be properly tied/fixed using proper aluminium clamps/cleats so that any kind of hanging /sagging shall be avoided. Breaking the wall/floor drilling holes to fix the clamps/ installing the conduit, laying the cable and plastering the wall shall be done by the contractor as required. Metal steel tags shall be used for identification of OFC/Cat 6 cables laid through overhead routes.
Bidder shall supply and use the OFC 6core cable as per Annexure IIIB. Other materials like aluminium clamps/ cleats and metal tag required for the work shall also be supplied by the bidder. | 250 | M | 13,750 ₹13,750 Lowest | 16,250 ₹16,250 |
| 1.03 | Supply & Laying of HDPE conduit (32MM) for cables as per attached specification in Annexure-IIIC. | 370 | M | 29,600 ₹29,600 | 27,750 ₹27,750 Lowest |
| 1.04 | Supply & Laying of HDPE conduit (20MM) for cables as per attached specification in Annexure-IIID. | 525 | M | 39,375 ₹39,375 | 28,875 ₹28,875 Lowest |
| 1.05 | Supply & Laying of Armoured XLPE power cable 3 core * 2.5 mm2 through HDPE conduits of 32mm size as per attached specification in Annexure-IIIE. | 370 | M | 49,950 ₹49,950 Lowest | 70,300 ₹70,300 |
| 1.06 | Supply of outdoor weather housing (IP 65) Panel/Rack suitable for Installing Camera adaptors / L2 switch/ Splice Box as per attached specification in Annexure-IIIF. These panels are to be used as the outdoor units (U1, U2) which house various components as shown in Annexure-IV scheme drawing. | 2 | NO | 25,000 ₹25,000 | 16,000 ₹16,000 Lowest |
| 1.07 | Supply of Managed L2 Industrial switch with minimum 4SFP ports & minimum 8 POE+ ports as per attached specification in Annexure-IIIG. | 2 | NO | 1,97,000 ₹1,97,000 Lowest | 2,20,000 ₹2,20,000 |
| 1.08 | Supply of 1000BASE-LX SFP Module. | 4 | NO | 14,000 ₹14,000 | 12,000 ₹12,000 Lowest |
| 1.09 | Supply of SC-LC Style single mode duplex patch cord, 3 meters. | 4 | NO | 6,000 ₹6,000 Lowest | 8,000 ₹8,000 |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
13 Aug 2025, 11:00 amClosed
NITHIN C S
SM (P and P)
Installation and configuration of CCTV Cameras and Networking System at NP Plant conveyor areas, Phase-II at FACT-CD.
2025_FACT_870748_1
04028/2025-2026/E31884
Open Tender
Miscellaneous Works
Item Rate
84 days
AMBALAMEDU
As per pre- qualification criteria.
8 documents required · 8 mandatory
₹0
₹12,000
Yes
27 Sept 2025
29 Jul 2025
14 Aug 2025
29 Jul 2025
13 Aug 2025
29 Jul 2025
Installation and configuration of CCTV Camera & Networking System at NP Plant conveyor areas, Phase-II at FACT-CD.
Supply & laying of Armoured CAT6 cable inside HDPE conduit (32mm/20mm). The work includes supply of CAT6 Armoured cable and laying the same overhead through HDPE conduit. Any route taken above ground viz. on compound walls or along steel girders or structural or cable ducts or cables tray shall be considered as overhead route. After laying, the conduit shall be properly tied/fixed using proper aluminium clamps/cleats so that any kind of hanging /sagging shall be avoided. Breaking the wall/floor drilling holes to fix the clamps/ installing the conduit, laying the cable and plastering the wall shall be done by the contractor as required. Metal steel tags shall be used for identification of OFC/Cat 6 cables laid through overhead routes. Bidder shall supply and use the CAT6 cable as per Annexure IIIA. Other materials like aluminium clamps/ cleats and metal tag required for the work shall also be supplied by the bidder.
Supply & laying of OFC 6core cable inside HDPE conduit (32mm/20mm). The work includes supply of OFC 6core cable and laying the same over head through HDPE conduit. Any route taken above ground viz. on compound walls or along steel girders or structural or cable ducts or cables tray shall be considered as overhead route. After laying the conduit shall be properly tied/fixed using proper aluminium clamps/cleats so that any kind of hanging /sagging shall be avoided. Breaking the wall/floor drilling holes to fix the clamps/ installing the conduit, laying the cable and plastering the wall shall be done by the contractor as required. Metal steel tags shall be used for identification of OFC/Cat 6 cables laid through overhead routes. Bidder shall supply and use the OFC 6core cable as per Annexure IIIB. Other materials like aluminium clamps/ cleats and metal tag required for the work shall also be supplied by the bidder.
Supply & Laying of HDPE conduit (32MM) for cables as per attached specification in Annexure-IIIC.
Supply & Laying of HDPE conduit (20MM) for cables as per attached specification in Annexure-IIID.
Supply & Laying of Armoured XLPE power cable 3 core * 2.5 mm2 through HDPE conduits of 32mm size as per attached specification in Annexure-IIIE.
Supply of outdoor weather housing (IP 65) Panel/Rack suitable for Installing Camera adaptors / L2 switch/ Splice Box as per attached specification in Annexure-IIIF. These panels are to be used as the outdoor units (U1, U2) which house various components as shown in Annexure-IV scheme drawing.
Supply of Managed L2 Industrial switch with minimum 4SFP ports & minimum 8 POE+ ports as per attached specification in Annexure-IIIG.
Supply of 1000BASE-LX SFP Module.
Supply of SC-LC Style single mode duplex patch cord, 3 meters.
Supply & Installation of PoE Injector as per attached specification in Annexure- III K.
Installation & Configuration of Fixed Cameras- F1, F2, F3, F4, F5, F6, F7, F8, F9, F10 and Integration with the network. The work involves:- (i) Installation of Cameras along with its Power and network connection. The cameras are to be wall/pillar mounted with proper orientation as per site requirements. (ii) All connections to the other Network elements (L2 switches inside Panel U1, U2, U3) to be verified.
Installation & Configuration of Panels U1, U2 and associated Network elements and Integration with existing network. The installation/integration work involves:- (i) Installation of Panels U1 & U2. (ii) Installation of supplied L2 switches inside the panels U1 & U2, Supply &Installation of Splice Box, Surge protectors, MCB’s inside the panels. (iii) All CAT6/OFC/Power cables shall be properly routed/ glanded at panels U1 , U2 & U3 as per the scheme in Annexure-IV. (iv) The PoE Injector shall be placed inside units U5 & U6 (units to be supplied & installed by Vendor) as per Annexure-IV scheme drawing. (v) All internal connections between the network elements as per the scheme in Annexure-IV. (vi) Assignment of IP addresses and connectivity to be checked to all the 10no.s of cameras, the existing FACT Network & the NVR at NP DCS control room.
Supply, installation & commissioning of video displays at NP Plant DCS control room (as per specifications Annexure-III H.) The installation & commissioning include the supply and installation of suitable power supply socket for the display and any other accessories required for the project but not mentioned in FACT’s scope.
Supply of NVR at NP Plant DCS control room (as per specifications Annexure-III-I)
Supply & installation of 1KVA UPS (as per specification in Annexure – III-J). The UPS to be mounted onto a wall using necessary clamps. Incoming connection to the UPS from the nearby 230VAC to be provided.
Installation & commissioning of NVR and associated units at NP Plant DCS control room. The work involves :- (a) Supply & Installation of the indoor rack units (Wall mounted) for the housing of the NVR. (unit U4) (b) Connection of CAT6/Power cables as per the scheme in Annexure-IV. (c) Installation of NVR and establishment of its network connectivity. (d) Establishing the connection between the NVR and Display Monitor and ensuring Video display of all the cameras. (e) Checking connectivity with the existing FACT network ( thru existing L2 switch at MCC room as per Annexure-IV)
3M ELECTRONIC SAFETY SYSTEMS (BID ID -3263408)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .