Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹5.4 L+₹56,644.89 (11.7%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹5.6 L+₹74,319.74 (15.3%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹12,712
Closing Date
17 Aug 2024, 6:00 pmClosed
AEE
PWD ESD KOZHOKODE
DEPOSIT-H FWD- Annual Plan 2016-17- Medical Education - Implementation of Plan Scheme- Establishment Modernization of drug store at Govt Medical College, Kozhikode- Additional electrical DEPOSIT-H FWD- Annual Plan 2016-17- Medical Education - Imp
2024_PWD_684858_1
PWD/BLDG/TR/22121/2023
Open Tender
Electrical Works
Item Wise
180 days
GMC Kozhikode
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,125
₹12,712
7 Oct 2024
8 Aug 2024
21 Aug 2024
8 Aug 2024
17 Aug 2024
8 Aug 2024
Amount
ELECTRIFICATION
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD221031/2023-2024:Supply, installation ,Testing and commissioning of 250/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
OD194815/2023-2024:supply and fixing Red, Green, blue, Yellow, Orange colours LED indicator, AC/DC, as required
OD194816/2023-2024:Supply and fixing Multifunction meter to read: V, A, F, 3 phase accuracy class 1
90.14.10.2:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
90.14.10.6:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.125A, 35/36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.10.14:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.250A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
2.2.13:Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA 4 Pole
OD194817/2023-2024:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve Triple pole, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD194818/2023-2024:Supplying and fixing 4P sheet steel enclosure on surface/ recess suitable for fixing 4P MCB, RCCB, Isolator etc. as required.
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD229702/2023-2024:Supply and Fixing of Spreader terminals adaptors kit (8pic) for MCCB 250A
OD194820/2023-2024:Supply and Fixing of Spreader terminals adaptors kit (8pic) for MCCB 125A
OD194821/2023-2024:Supply and Fixing of Spreader terminals adaptors kit (8pic) for MCCB up to 100A
90.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
90.12.41.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD194822/2023-2024:Supply and providing 12x3mm brass nut and bolt etc. as required.
OD194823/2023-2024:Supply and providing 25x3mm brass nut and bolt etc. as required.
4.1.4:Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness
General service and shifting of 100KVA cummins make DG
OD234705/2023-2024:Supply and replacing of cartridge oil filter
OD234706/2023-2024:Supply and fixing of fuel water separator
OD234707/2023-2024:Supply and replacing of fuel filter
OD234708/2023-2024:Supply and changing of Valvoline premium blue 7800 plus oil (20Litre)
OD234709/2023-2024:Packing and handling charges
OD234710/2023-2024:Supply and fixing of battery "Pulse lite" 12V 65AH
OD234711/2023-2024:Supply and filling of inhibitor corrosion 10 Litters
OD234712/2023-2024:Service Charges for 100KVA DG make Cummins
OD234713/2023-2024:FREIGHT CHARGES
OD234717/2023-2024:Shifting of 100KVA Cummins make DG from Linac to New Drug store
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7:Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
OD234718/2023-2024:Providing and fixing 32 mm X 6 mm G.I. strip earth lead from the test joint to the earth plate
OD234719/2023-2024:Providing and fixing 2 X 32 mm X 6 mm G.I. strip test joint for earthing system
90.12.5.33:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 150 sq mm
90.12.7.33:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 150 sq mm
90.12.12.6:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation110/94 mm or nearest size
90.16.1.5:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG)
90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG)
9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
OD234750/2023-2024:Supply and providing 25x3mm brass nut and bolt etc. as required.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
SAJITHLAL K
RAMAKRISHNAN A P
Bidder Name
gopakumar.kv
RAMAKRISHNAN A P
SAJITHLAL K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1065701.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .