Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹13.9 L+₹3,404 (0.25%)Rejected-AOC 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹15.1 L+₹1.3 L (9.12%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹15.5 L+₹1.7 L (12.1%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder |
Tender Value
Refer Docs
Closing Date
10 Apr 2023, 6:00 pmClosed
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
REPAIR TO STREET LIGHT, DG SET AND CONNECTED WORKS, REPAIR TO HT VCB, GOD, LT PANEL AND ELECTRIC CABLES AT AIR FORCE STATION HIGHGROUNDS
2023_MES_578491_2
CWE/AF CHD/CHD/T-36/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I)(AF) Highgrounds
Exempted
19 May 2023
13 Mar 2023
17 Apr 2023
13 Mar 2023
10 Apr 2023
27 Mar 2023
Amount
EXTERNAL ELECTRIFICATION
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Material and labour, locally available, sub class `B’ bricks (old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection, complete all as specified and directed.
Material and labour, un- reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx180mmx40mm laid flat perpendicular to the direction of cable for protection of cable, complete all as specified and directed.
Taking out / down old existing LT 1100volt grade cables, size 10Sqmm, aluminium conductor 2core, XLPE/ PLCA/ PVC, armoured, laid in trenches, including bricks for protection, sand cushioning and stacking, removal to store for re-use or for credit, complete all as specified and directed Note : Excavation shall be measured and paid for separately
All as per Serial Item No. 1.07 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 1.07 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 1.07 here-in-before but 50Sqmm 3Core size
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 10Sqmm 2 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
All as per Serial Item No. 1.11 here-in-before but 16Sqmm 2Core size
All as per Serial Item No. 1.11 here-in-before but 35Sqmm 3.5Core size
All as per Serial Item No. 1.11 here-in-before but 50Sqmm 3.5Core size
All as per Serial Item No. 1.11 here-in-before but 95Sqmm 3.5Core size
Supply, jointing & testing, indoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armoured aluminium conductor cable, 3core, 95Sqmm size cable, complete all as specified and directed.
Supply, jointing & testing, outdoor end termination joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3wire, 11KV (Earthed) grade, HT, underground XLPE insulated armored aluminium conductor cable, 3core, 95Sqmm size cable, complete all as specified and directed.
Supply and laying / fixing , GI pipe light grade 100mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directed. Note: Boring of holes under road etc. shall be measured and paid separately.
Supply and laying / fixing , GI pipe light grade 80mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directed. Note: Boring of holes under road etc. shall be measured and paid separately.
Supply and laying / fixing , GI pipe light grade 50mm dia bore for cable protection fixed to pole/wall or laid under floor/road/pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and directed. Note: Boring of holes under road etc. shall be measured and paid separately.
Material and labour for switch air break, gang operated triple pole, mechanically operated, mounted on 12 insulators including drop out insulators including 3 nos barrel type drop out fuses and steel frame with operating mechanism worked from ground level with 25mm light grade GI tubing for current rating upto 400 amps,11000 volt including taking down old and removal complete all as specified and directed.
Material and labour for switch air break, gang operated triple pole, mechanically operated, mounted on 12 insulators including drop out insulators including 3 nos barrel type drop out fuses and steel frame with operating mechanism worked from ground level with 25mm light grade GI tubing for current rating upto 200 amps,11000 volt including taking down old and removal complete all as specified and directed.
Material and labour for lightening arrestor high tension, expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp, suitable for 11000 volt grade system fixed in position including disconnecting and taking down old and removal, complete all as specified and directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 metres long), complete all as specified and directed (Excavation and PCC paid seprately)
Dismantling/strip opening of the HT VCB 11 KV 400 Amps of calibration, repairing, preventive maintenance, , servicing including replacement of worn out parts to make it fully functional, reassembling the same after repair, installation to its original position, connection input/output supply, testing to its full load capacity and all other relevant tests as per IE/IS rules complete all specified and directed. Note : Spare parts required for repair/replacement shall be measured and paid separately under BOQ item No 1.26 to 1.31 here in after.
Supply only, PT trannsformer of 11KV/110V, totally ennclosed, sealed and stamped, epoxy filled, heavy duty, suitable for 11 KV, 400 Amps HT VCB, complete all as specified and directed.
Supply only, Micro process based relay heavy duty, suitable for 11 KV 400Amps HT VCB, complete all as specified and directed.
Supply only, vaccum interruptor for VCB, complete all as specified and directed.
Supply only, trolly insulator for mounting vaccum interruptor for VCB, complete all as specified and directed.
Supply only, epoxy fibre base plate for interruptor, complete all as specified and directed.
Supply only, epoxy insulator for bus bar supports, complete all as specified and directed.
Supply and fix, finger moving contact (Made up of six, each male and female, fingers), spring loaded, heavy duty, suitable for 11KV, 400Amp, HT VCB, complete all as specified and directed.
Supply only, Current Transformer (CTs) of CTR 50-25 / 5Amps, totally enclosed, sealed and stamped, epxoy filled, heavy duty, suitable for 11 KV 400 Amps HT VCB, complete all as specified and directed.
Supply and fix in replacement of spout type insulator suintable for HT VCB including cleaning the bus bar, complete all as specified and directed.
Servicing of all relays, Battary Bank, and checking calibration and time gap, adjustment of earth fault relay, over current relay and reconnecting all the relays to their respective circuits and locations, of HT VCB 11 KV 400 Amps, and testing on completion to the entire satisfaction of Engr-In-Charge, complete all as specified and directed.
Supply and installed Moulded Case Circuit Breaker (MCCB) 4 pole, 415V, 36 KA, 250 AMPS, Adjustable overload settings conforms to IS/IEC 60947-2 & IEC 60947-2, complete all as specified and directed.
Supply and installed Moulded Case Circuit Breaker (MCCB) 4 pole, 415V, 36 KA, 200 AMPS, Adjustable overload settings conforms to IS/IEC 60947-2 & IEC 60947-2, complete all as specified and directed.
Supply and installed Moulded Case Circuit Breaker (MCCB) 4 pole, 415V, 36 KA, 400 AMPS, Adjustable overload settings conforms to IS/IEC 60947-2 & IEC 60947-2, complete all as specified and directed.
Supply and installed Moulded Case Circuit Breaker (MCCB) 3 pole, 415V, 36 KA,160 AMPS, Adjustable overload settings conforms to IS/IEC 60947-2 & IEC 60947-2, complete all as specified and directed.
Supply and installed Moulded Case Circuit Breaker (MCCB) 3 pole, 415V, 36 KA, 200 AMPS, Adjustable overload settings conforms to IS/IEC 60947-2 & IEC 60947-2, complete all as specified and directed.
Supply, installing, testing and commissioning outdoor type feeder pillar box of size 90cm x 60cm x 30cm suitable for 415 volts 3 phase 4 wire 50 Hz AC supply having bus bar chamber with insulated on porcelain insulators. The panel shall be dust and vermin proof, IP 65 protection and made out of MS CRCA quality sheet 3.15mm thick and 50mm x 50mm x 6mm angle iron base frame with 04 Nos legs 75 cm long made out of MS angle, legs embedded in PCC (1:2:4) having bottom of the panels at height of 45 cm above ground level, dully powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer inside and front openable type with aprons for cable entry with double door shutter and locking arragements, complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-1 using 20mm graded stone aggregate for coping incuding necessary form work, complete all as specified and directed.
Material and Labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation filling, complete all as specified and directed.
Material and labour, Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer including dismantling, complete all as specified and directed.
DG SET REPAIRS
Maintenance of DG set of any make, type, model as per set norms of the original manufacturer set and by the authorised rep of the company after unscrewing nut, bolts, screws etc. for servicing, maintenance, tigthtening, adjustment & cleaning of all moving and stationary parts of DG set, complete and segregating the parts for repair/ refixing/ replacing of capacity 10KVA installed at IMMOLS , complete all as specified and directed. Make of DG sets :- kirloskar/Crompton Greaves/ Ruston/ Ashok Leyland Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only item as apended below.
All as per Serial Item No. 2.01 here-in-before but capacity 35 KVA
All as per Serial Item No. 2.01 here-in-before but capacity 63 KVA
All as per Serial Item No. 2.01 here-in-before but capacity 75KVA
All as per Serial Item No. 2.01 here-in-before but capacity 82.5KVA
All as per Serial Item No. 2.01 here-in-before but capacity 400KVA
Supply only under mentioned spare/parts suitable for the DG set complete all as specified and directed:-
Primary fuel filter element for DG set capacity 10 KVA
Primary fuel filter element for DG set capacity 35 KVA
Primary fuel filter element for DG set capacity 63 KVA
Primary fuel filter element for DG set capacity 75 KVA
Primary fuel filter element for DG set capacity 82.5 KVA
Primary fuel filter element for DG set capacity 400 KVA
Secondry fuel filter element for DG set capacity 10 KVA
Secondry fuel filter element for DG set capacity 35 KVA
Secondry fuel filter element for DG set capacity 63 KVA
Secondry fuel filter element for DG set capacity 75 KVA
Secondry fuel filter element for DG set capacity 82.5 KVA
Secondry fuel filter element for DG set capacity 400 KVA
Air filter element for DG set capacity 10 KVA
Air filter element for DG set capacity 35 KVA
Air filter element for DG set capacity 63 KVA
Air filter element for DG set capacity 75 KVA
Air filter element for DG set capacity 82.5 KVA
Air filter element for DG set capacity 400 KVA
Oil filter element for DG set capacity 10 KVA
Oil filter element for DG set capacity 35 KVA
Oil filter element for DG set capacity 63 KVA
Oil filter element for DG set capacity 75 KVA
Oil filter element for DG set capacity 82.5 KVA
Oil filter element for DG set capacity 400 KVA
Fuel line complete for DG set capacity 10 KVA
Fuel line complete for DG set capacity 35 KVA
Fuel line complete for DG set capacity 63 KVA
Fuel line complete for DG set capacity 75 KVA
Fuel line complete for DG set capacity 82.5 KVA
Fuel line complete for DG set capacity 400 KVA
Material and labour for taking out radiator and repairing/brazing to make it leakage free, cleaning and re-fixing the radiator including testing for DG set capacity 10 KVA to 40 KVA, complete all as specified and directed.
All as per item No. 2.38 here-in-before but DG set capacity 400 KVA complete all as specified and directed.
Supply only lubricant oil (Engine oil) SAE30 (Make as recommended by the manufacturer of DG set and as approved)
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 180AH, complete all as specified and directed.
Supply, install, connecting and testing in replacement maintenance free batteries, 12 Volts, 92AH, complete all as specified and directed.
Supply and fix, battery lead not less than 1.5mtr long, made out of 50Sqmm copper cable with terminal of brass with marking (+)/(-) and fixing in position and testing, including taking down and removal, complete all as specified and directed.
Supply and filling, engine coolant in radiators of DG sets as per DG set manufacturer's recommendations at different locations, brought at site in sealed packets, complete all as specified and directed.
Maintenance, repair, servicing and calibration of automatic mains failure panel, DC & 415/440 volt AC supply operated system by locating faults and replacement of unserviceable parts and components for DG set 10KVA to 400KVA and testing on completion , complete all as specified and directed. Make of DG sets:- Kirloskar/Crompton Greaves/Ruston/Ashok Leyland Note: The quoted rate includes the following: (a) Taking down of unserviceable parts. (b) Any minor repair, replacement of minor parts such as screws, gasket, nuts, bolts, washers, cleaning & greasing etc. of DG set parts. (c) Defective parts/ engine oil to be replaced will be measured & paid separately under supply only
Repair of faulty worn out control wiring DC/AC for engine starting and off, with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing, complete all as specified and directed.
Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals, complete all as specified and directed.
Material and labour for repairing battery charging dynamo including replacing work out/unserviceable spares upto the capacity of 75 KVA to 82.5 KVA, complete all as specified and directed.
Material and labour for repairing battery charging dynamo including replacing work out/unserviceable spares upto the capacity of 400 KVA, complete all as specified and directed.
Material and labour for repairing self starter including replacing work out/unserviceable spares upto the capacity of 35 KVA to 82.5 KVA, complete all as specified and directed.
Material and labour for repairing self starter including replacing work out/unserviceable spares upto the capacity of 400 KVA, complete all as specified and directed.
Material and labour for replacing the unserviceable AVR of DG sets upto the capacity 75 KVA to 82.5 KVA and testing, complete all as specified and directed.
Material and labour for replacing the unserviceable AVR of DG sets upto the capacity 400 KVA and testing, complete all as specified and directed.
Power contractor 3 pole 200 Amps 415 volts operating coil voltage 230 Volts, complete all as specified and directed. Make:- Havells/L&T/ABB
Power contractor 3 pole 315 Amps 415 volts operating coil voltage 230 Volts, complete all as specified and directed. Make:- Havells/L&T/ABB
Power contractor 3 pole 400 Amps 415 volts operating coil voltage 230 Volts, complete all as specified and directed. Make:- Havells/L&T/ABB
Material and labour for repair to unserviceable street/security light fittings of LED of any wattage and size by taking down from poles/buildings after disconnecting the electric connection, replacing the unserviceable driver, PVC connector etc, cleaning and refixing the light fittings at its original position after rectifying the defects and connecting to street light feeder including testing, complete all as specified and directed. Note:- (i) Replacement of parts like driver etc will be measured and paid separately. (ii) The cost of labour ,tools and minor spares required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with powder coated high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66, complete all as specified and directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with powder coated high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66, complete all as specified and directed.
Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with ecorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Supply and fix in replacement of 200x160x98mm PVC junction box having IP 65 protection with metric knockouts for 16/25 sqmm cable entry with terminalals /bus bar 4 pole including provn of one MCB 6 Amps, complete all as specified and directed.
Supply and fixing LED Street light driver of suitable capacity complete prewired and connected with flexible copper conductor cable, complete all as specified and directed.
Supply and fixing LED 10 watts round type bollard garden light fittings diffuser at the upper portion act as a beacon of path guidance all as specified and directed by Engineer in charge.
Note: The Total amount shall subject to adjustment of credit of Rs.54584.00 for old Materials as per Schedule of Credit
u and v engineers and consultants
PARTAP ENGINEERING WORKS
Sabhyata Electrical and Mechanicals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .