Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC PATHARKANDI DIST SRIBHUMI | KARIMGANJ | ASSAM | 788152 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹26.6 L+₹245 (<0.01%)Rejected-Finance TEZPUR ASSAM | SIVASAGAR | ASSAM | 785640 | L2 | Rejected-Finance L2 |
Tender Value
₹26.6 L
EMD Value
₹53,260
Closing Date
8 Sept 2023, 4:00 pmClosed
EE PWD Sonitpur District Territorial Bldg Div
O/o EE PWD Sonitpur District Territorial Bldg Div
Repair / Renovation of Nurse Hostel at Kanaklata Civil Hospital, Tezpur
2023_PWBNH_32124_1
EE/Tender/4/2022-23/6865-70 Dtd. 02/08/2023
Open Tender
Civil Works - Building
Item Rate
180 days
Tezpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹540
₹53,260
Yes
Tezpur
2 Nov 2023
18 Aug 2023
11 Sept 2023
18 Aug 2023
8 Sept 2023
27 Aug 2023
24 Aug 2023
Amount
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 meters lead of: 15.28.1 G.S. Sheet
Dismantling wood work in frames, trusses, purlins and rafters up to 10 meters span and 5 meters height including stacking the material within 50 meters lead. 15.14.1 of sectional area 40 square centimetres and above
Dismantling cement asbestos or other board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 meters lead.
Dismantling old plaster or skirting ranking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead.
Dismantling doors, window and clerestory windows (steel or wood) shutter including chowkath, architrave, holdfast etc. Complete and stacking within 50 metres lead:15.12.1 of area 3sqm and below.
Demolishing cement concrete manually or/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-in-charge. 15.2.1 Normal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal /vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.12.1.3:-0.63 mm thick with zinc coating not less than 275 gm/sqm
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed polymer coated J or L hooks, bolts and nuts 8mm dia GI limpet and bitumen washers complete.12.4.2:- 0.63mm thick with zinc coating not less than 275 gm/sqm.
Providing wood work in frames of door, window, clearstory windows and other frames, wrought framed and fixed in position with holdfast lugs or with dash fasteners of required dia & length (holdfast lugs or dash fasteners shall be paid for separately). 9.1.2 Sal wood
Providing and fixing panelled or panelled glazed shutters for door, window and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge (Note: Butt hinges and necessary screws shall be paid separately). 9.5.1 Second Class teak wood 9.5.2 30mm thick shutters
52mm thick cement concrete flooring with concrete hardner topping under layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardner consisting of mix 1:2 (1 cement hardner mix: 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. Complete.
Providing and laying vitrified tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
12mm cement plaster mix: 13.1.1:- 1:4 ( 1 cement: 4 fine sand).Qty BF item No. 4/15.56
Providing and fixing plain multipurpose cement board (High pressure steam cured) with suitable screws for cement particle board in ceiling etc. Complete (frame work to be paid separately). 12.26.1 6mm thick cement fibre board as per IS: 14862
Renewing glass panels, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panels of nominal thickness 4 mm (weight not less than 10kg/ sqm)
Providing & fixing white vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. 14.80.2 Orissa pattern W.C Pan of size 580x440 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement as per direction of Engineer in charge 18.9.6 50 mm nominal dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement as per direction of Engineer in charge 18.9.3 25 mm nominal dia Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 18.7.3 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 18.7.1 15 mm nominal diaPipes
Providing & fixing brass bib cock of approved quality: 18.15.1 15 mm nominal bore
Providing and fixing washing basin with CI brackets, 15 mm dia CP brass single hole basin mixer of approved quality and make, including painting of fitting and brackets, cutting and making good the walls wherever require:- 17.7.1 White Vitreous China wash basin size 630x450 mm with a pair of 15 mm CP brass pillar taps
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fitting, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other coupling in C.P. brass, including painting of fitting and cutting and making good the walls and floors wherever required: 17.5.1 Single half stall urinals with 5 litre P.V.C. automatic flushing cistern
Providing & fixing stainless steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. including painting of fittings and brackets, cutting and making good the walls wherever required: 17.10.1 Kitchen sink with drain board 17.10.1.1 510x1040 mm bowl depth 250 mm
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratching etc. Complete.
Distempering with 1st quality acrylic distemper, having VOC ( Volatile Organic Compound) content less than 50 gram/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.13.81.2 Two coats.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shad: 13.99.1 One or more coats on old work.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 1.14.1 2x 1.5 sq. mm + 1 x 1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 1.14.2 2x 2.5 sq. mm + 1 x 2.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 1.14.3 1mm + 1 x 4 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 1.14.4 1mm + 1 x 6 sq.mm earth wire
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminatied sheet cover in front including painting etc. As required. 1.22.1 75 mm x 75mm x 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminatied sheet cover in front including painting etc. As required. 1.22.3 150 mm x 75mm x 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminatied sheet cover in front including painting etc. As required. 1.22.9 200 mm x 250mm x 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminatied sheet cover in front including painting etc. As required. 1.22.15 250 mm x 300mm x 60 mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.23.1 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.23.3 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.23.4 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.24.5 3 pin 15/16 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 1.23.8 Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 v, completed as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. As required.1.50.1 Up to 450mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 2.3.1 6Way, Double Door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1 4Way (4+12), Double Door
Supplying and fixing 5A to 32A rating, 240/415V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. As required, 2.10.1 Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.2 Single pole and neutral
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A 2.13.2 63A
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.21 31/2x35 sq. Mm (32 mm)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re filling etc as required. 14.13.1 50 mm dia
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying of following size of AC exhaust fan as specified and directed by the department. (USHA/ Havells or equivalent make as approved by this Dept.)
Supply, installation, testing and commissioning of smart bright 4ft LED batten tube light including all accessories as per direction & specification by the Deptt. (Phillips/ Havells/ Cropmton or equivalent make)
Supplying of following size of PVC/XLPE insulated and PVC Sheathed 1.1 KV gd Solid Aluminium conductor up tp 10 sqmm, balance stranded conductor, XLPE insulated, croes laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sqmm, balance Aluminium Strip, Galvanised wire for cables up to 2x10 sq mm, 3x10 sq mm, 4x 10 sq mm & balance all galvanised steel strip), extruded PVC type ST2 Sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G. cable as specified and directed by the department. (Havells/RR Kabels/Polycab or equivalent make as approved by this Dept.) 35.00 sq mm 3.5 Core Armoured UG Cable.
M/S Kalpana Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .