Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | ₹36.3 L Quoted ₹36.9 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹38.8 L+₹1.9 L (5.24%)Rejected-Finance KALAPAHAR BIMALANAGAR GUWAHATI 781016 DISTT KAMRUP ASSAM | KAMRUP METRO | ASSAM | 781016 | ₹38.8 L+₹1.9 L (5.24%) | L2 | Rejected-Finance NOT BEING LOWEST |
| 3 | L3₹39.3 L+₹2.4 L (6.52%)Rejected-Finance | ₹39.3 L+₹2.4 L (6.52%) | L3 | Rejected-Finance NOT BEING LOWEST |
| 4 | L4₹39.3 L+₹2.4 L (6.59%)Rejected-Finance MISSAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | ₹39.3 L+₹2.4 L (6.59%) | L4 | Rejected-Finance NOT BEING LOWEST |
| 5 | L5₹41.6 L+₹4.7 L (12.8%)Rejected-Finance GRAM RAKSHAWARA THANA KARARI TAH MANJHANPUR KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | ₹41.6 L+₹4.7 L (12.8%) | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹49.4 L
EMD Value
₹99,000
Closing Date
7 Jan 2021, 6:00 pmClosed
GE MISAMARI
PO-Missamari Dist-Sonitpur Assam
REPAIR TO ROOFING FALSE CEILING AND OH TANK IN MD ACCN OF OFFRs JCOs AND ORs AT NORTH OF RAILWAY LINE UNDER GE MISAMARI
2020_MES_404077_1
8158
Open Tender
Civil Works
Item Rate
270 days
GE MISAMARI
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
Yes
GE MISAMARI
₹99,000
Yes
19 Jan 2021
16 Dec 2020
9 Jan 2021
16 Dec 2020
7 Jan 2021
26 Dec 2020
16 Dec 2020 - 21 Dec 2020
Amount
Dismantling AC Corrugated/ Semi corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as specified and as directed.
Dismantling plain or corrugated steel Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, any gauge, thickness, including Nainital or similar pattern complete all as specified and as directed.
Dismantling Wall and Ceiling Boards (Fibre, Pulp, Insulation, etc.) or Insulation Boards /Blankets/Slabs, any description and any thickness including Cover Fillets, Cornices, etc., complete all as specified and as directed.
M&L Second Class Hardwood Boarding 25mm thick, plain one side with butt joints, and fixed with nails as in Eave boards, complete all as specified and directed .
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S& F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S & F false ceiling with 4mm thick desingner 'E' Board of Everest Ltd or Charminar as approved by GE fixed with GI powder coated inverted Tee or 'L' section of cicago metallic or Equivalent as approved by GE suspended from ceiling with FI 25x5 mm thick or butterfly hold down clips with necessary hold fastners / self tapping screws as per manufacturer instruction complete all as directed and specified incl (a) Main runner of size 38x24x0.8mm (b) Cross tee size 28x24x0.8mm (c) Wall angle 22.2x22.2x0.65 mm (d) Butter fly clip / hold down clip (f) Size of grid 605x605mm (g) Two coats oil bound distemper one side of board (h) Powder coating on exposed side of tee/angle etc complete all as specified and directed.
Dismantling timber scantling 40 sqcm and over in section unframed work in any position complete all as specified and directed.
M&L 2nd class hard wood in scantling, clean sawn, timber fixed with nails complete all as specified and directed.
Demolition PCC as in Roofs pedding(incl APP mebrane chajjas and similar item complete all as specified and as directed.
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top as specified and directed:- (i) Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (ii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iii) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (iv) Applying two coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
Supply only Integral liquid Proofing Compound, conforming to IS 2465-1975 complete all as specified.
Disconnecting existing tank exc 250 n.exc 1000 setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scales and dirt etc from tanks and from moouths of circulating pipes etc complete all as specified and directed.
S&F in repair for Rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical vertical with closed top) including wash out GI pipe 32mm of 450mm length with stopper complete all as specified.
S&F in repair for Rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylindrical vertical with closed top) including wash out GI pipe 32mm of 450mm length with stopper complete all as specified.
Taking up or down steel tubing and connection incl cleaning for refixing 15 mm dia bore complete all as specified and directed.
Taking up or down steel tubing and connection incl cleaning for refixing 20 mm dia bore complete all as specified and directed.
S&F GI tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors for 15 mm bore complete all as specified and directed.
S&F tubes medium grade, galvanised with all fittings and fixed complete to walls and ceiling or laid in floors for 20 mm bore complete all as specified and directed. .
Refixing only steel GI tubes of 15mm dia bore including all fittings complete all as specified and directed.
Refixing only steel GI tubes of 20mm dia bore including all fittings complete all as specified and directed.
S&F for 20mm dia Ballcock valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s ) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping etc including necessary form work, weathering slightly rounded or chamfered angles and throating complete all as spfd and directed.
M & L for preparation of new wood or wood based surfaces of any description over 10cm width or girth & applying two coat of synthetic enamel paint of approved quality over a coat of pink primer, tint to achieve glossy finish, complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint of approved quality, tint to achieve glossy finish, complete all as specified and directed.
M/S M.S. ENTERPRISE
M/S Mahabir Traders
MAA CONSTRUCTION
M/S NARENDRA AND COMPANY
Sunrise Enterprise
BEE KAAY TRADERS
M/S S.S.Corporation
Satya Enterprises
Markson
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .