Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | ₹17.9 L Quoted ₹18.9 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹19.0 L+₹7,425 (0.39%)Rejected-Finance | ₹19.0 L+₹7,425 (0.39%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹22.5 L+₹3.6 L (18.8%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹22.5 L+₹3.6 L (18.8%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹23.2 L+₹4.3 L (22.6%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | ₹23.2 L+₹4.3 L (22.6%) | L4 | Rejected-Finance BEING L4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
7 Feb 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / REPLACEMENT OF INTERNAL ELECTRIFICATION AT HARNI AREA AT AF STN BARODA
2023_MES_574478_1
8774/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹40,000
Yes
2 Mar 2023
11 Jan 2023
9 Feb 2023
11 Jan 2023
7 Feb 2023
25 Jan 2023
12 Jan 2023 - 19 Jan 2023
Amount
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective piano switch /socket on normal/modular switch board/ceiling rose/holders/ fittings / fixtures any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc, complete all as specified and directed.
Identifying/detecting defects in unserviceable wiring and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs SP /SPN/DPs/TPN any type, rectification of faulty due to loose connection in electric circuits, tightening of loose connections, replacement of U/S MCBs, U/S portion of conductor etc, complete all as specified and directed.
Identifying/detecting defects in unserviceable ceiling fan/exahaust fan/wall fan/ turbofan and rectifying the defects pertaining to genral servicing such as taking down defective fans any type, rectification of fault due to loose connection/u/s connecting wire, due to U/s capacitor, u/s due to lubrications, U/S hanging clamp etc rectified the same with tightening of loose connections, replacement of U/S conneting wire, repacement of U/S capacitor, servicing by opeing /dismentling fan cleaning the bearing and lubricating the same etc, complete all as specified and directed.
Load balancing on three phase DBs of buildings inclding checking of load by using amp meter/tong tester rearreging the connections withing the DBs and providing copper lugs with wires tightening of all connection and testing and verify the lthe load current on each phase in persence of JE E/M/ Engr-incharge complete all as specified and directed.
NOTE FOR ITEM NO 1.00 to 4.00 :- (a) All T & P/Stationeries and labour team required comprising of sufficient trained technician (Electrician/helper ) will be provided by the contractor daily for two location ie harni camp and harni airfield baroda area as directed.During MES mela or any other occason the contractor will be arrage additional menpower to rectify the complaint with justified time. b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed & on contractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, lubricating oil/grease etc shall be deemed included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, capacitor, wires etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevent item. (e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per complaint will be penalised.
Checking/testing of Earth resistance value of earthing pits Installed inside harni camp and hari airfield area as requirement basis as directed by Engr in Charge or as schedule and making the damaged earthing serviceable by pouring salted water into earthing or making continuity by GI strips and bringing down the resistance value within specified limits. including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vagetation surrouding earthing pit up to 2 mtr. complete all as specified and directed.
Note: (i) The entire station will be divided into two zones as per earthing location and the contrcator will deploy seperate team for each zone to test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated after every six months (half yearly) upto completion of the contract. (ii) one earthing testing in one season is measured one job. (iii) Digital Earth tester will be arrenge by the contractor his own. (iv) Date of testing and due date of testing is to be written on a register with sign of user rep & Engr-in Charge submitted to GE. (iv) Testing and correction action is to be done within one month from date of commencement i.e. approx 200 earthings is to be completed within one month. Thereafter on half yearly basis or as directed byEngr-in charge and same is to be completed within one month.The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month. (v) If any material required for improvement of resistence value which value is more than their permissible limit will be measured and paid seperately.
Supply only switch piano flush type single pole one way 5 Amp 240 Volts. complete all as specified and directed.
Supply only 5 Amps Socket only 3 Pin flush type complete all as specified and directed.
Supply only 15 Amps Switch only 3 Pin flush type complete all as specified and directed.
Supply only 15 Amps Socket only 3/5 Pin flush type complete all as specified and directed.
Supply only switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt. complete all as specified and directed.
Supply only switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt. complete all as specified and directed.
Supply only switch piano flush type single pole two way 5 Amp 240 Volts. complete all as specified and directed.
Supply only Bell push flush type single pole 5 Amp 240 Volts. complete all as specified and directed.
Supply only modular switch one way 6 Amps 1 module 240 Volts. complete all as specified and directed.
Supply only modular switch one way 16 Amps 1 module 240 Volts. complete all as specified and directed.
Supply only modular switch two way 6 Amps 1 module 240 Volts. complete all as specified and directed.
Supply only modular bell push way 6 Amps 1 module 240 Volts. complete all as specified and directed.
Supply only modular socket outlet 6A 3 pin 2 module 240 Volts. complete all as specified and directed.
Supply only modular socket outlet 6A/16 5 pin 2 module 240 Volts. complete all as specified and directed.
Supply only modular fan regulator 120W-2 module 240 Volts. complete all as specified and directed.
Supply only Bell push flush type single pole 5 Amp 240 Volts. complete all as specified and directed.
Supply only Bell ding dong type, one way, 240 volts, AC, ISI marked.complete all as specified and directed.
Supply only ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. complete all as specified and directed.
Supply only stright/Angle bulb holder pvc body complete all as specified and directed.
Supply only Stepped/socket type electronic fan regulator heavy duty type A/C 240 V.complete all as specified and directed.
Supply only capacitor 2.5 mfd 240V ISI mark complete all as specified and directed.
Supply only capacitor 4 MFD suitable for any make, type & sweep ceiling fan, exhaust fan, cabin fan & pedestal fan complete all as specified and directed.
Supply only LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
Supply only Integrel sleek extruded batten aluminium /CRCA channel fitting with LED T8 Lamp 20 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed.
Supply only batten integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 as per Cat No BCLSB 05 WH of Bajaj or equivalent of approved make, complete all as specified and directed.
Supply only in replacement LED tube rod suitable for any type of LED Tube Light fitting of 18/20 watt, complete all as specified and directed.
Supply only in replacement MCB single pole 6 to 30 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only MCB single pole 32/40Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only MCB SPN 32/40Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB TPN 32 to 50 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB TPN 63 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
M&L for point wiring with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade (conforming IS 694) in and incl not less than 2mm thick PVC casing/caping ISI marked, with all accessories including one run of 1.5 Sqmm multistrand PVC insulated FRLSH stranded copper conductor cable (green colour) for earth continuity conductor to common earth dolly including all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading "Point wiring'". fixed on walls/ceiling including PVC box surface/ flush type SS sunken boxes with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc complete covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall to match with the existing finish etc for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One bell point controlled by one way switch
One light point controlled by two way switches
M&L for point wiring with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade(conforming IS 694) in and including minimum 20 mm dia ISI marked stove enamel rigid metalic steel conduit of with all accessories, including one run of 1.5 Sqmm multistrand PVC insulated FRLSH stranded copper conductor cable (green colour) for earth continuity conductor to common earth dolly including all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading "Point wiring'".fixed on walls/ceiling including wooden box and connected to flame proof switch, sockets etc all as specified and directed.for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall to match with the existing finish etc for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
M&L for concealed point wiring with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade(conforming IS 694) including non metelic rigid heavy duty PVC conduit size not less than 20mm dia and quality ISI marked, including one run of 1.5 Sqmm multistrand PVC insulated FRLSH stranded copper conductor cable (green colour) for earth continuity conductor to common earth dolly including all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading "Point wiring'".fixed on walls/ceiling including SS sunken box with modular cover plate for mounting fittings like modular switch, sockets etc all as specified and directed.for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall to match with the existing finish etc for the following complete all as specified and directed:-
One light point controlled by one one/way switch.
One Fan/Exahaust fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board
One bell point controlled by one one/way push button
One light point controlled by two way switches
Description all as per item No 40.00 above but for power point 3 pin switch socket 15 Amp with with FRLS cable PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm (conforming IS 694) on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in complete all as specified and directed.
M & L Power point 3 pin switch socket 15 Amp with with FRLS cable PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in and including PVC casing and capping of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including flush SS sunken box/ PVC terminal boxes on surface for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover complete all as specified and directed.
All as per item No.42.00 above but wiring with with FRLS cable 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
Note (for item Ser No 38.00 to 43.00 above): (i) The quoted rates shall be deemed to be inclusive of sunction boxes/modular cover plate and cutting chases in brick walls/pillars etc for concealing the depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the portion of point wiring at for covering / fix sunken boards/terminal boxes/junction boxes of any shape and size . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for seperatly of cencern item of Sch’A’. (iii)The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at Darjipura Main receiving station to carry out maintenance within stipulated time.without fail
M & L for sub main wiring using with FRLS cable two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
M & L for sub main wiring using with FRLS cable two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
Note (for item Ser No 44.00 & 45.00 above): The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at Darjipura Main receiving station to carry out maintenance within stipulated time.without fail
S&F switch piano flush type single pole one way 5 Amp 240 Volts.complete all as specified and directed.
S&F 5 Amps Socket only 3 Pin flush type complete all as specified and directed.
S&F 15 Amps Switch only 3 Pin flush type complete all as specified and directed.
S&F 15 Amps Socket only 3 Pin flush type complete all as specified and directed.
S&F switch piano flush type single pole two way 5 Amp 240 Volts. complete all as specified and directed.
S&F Bell push flush type single pole 5 Amp 240 Volts. complete all as specified and directed.
S&f modular switch one way 6 Amps 1 module 240 Volts. complete all as specified and directed.
S&F modular switch one way 16 Amps 1 module 240 Volts. complete all as specified and directed.
S&F modular switch two way 6 Amps 1 module 240 Volts. complete all as specified and directed.
S&F modular bell push way 6 Amps 1 module 240 Volts. complete all as specified and directed.
S&f modular socket outlet 6A 3 pin 2 module 240 Volts.complete all as specified and directed.
S&f modular socket outlet 6A/16 5 pin 2 module 240 Volts. complete all as specified and directed.
S/F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. complete all as specified and directed.
Supply and fixing in repair stright/Angle bulb holder pvc body complete all as specified and directed.
Supply and fixing repair in Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V. complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
S/F in repair Load line 6 way load line segrigated Vertical type(VTPN DB) DB double door, duly powder coated 415 volt with provision for 125 Amps MCCB as incomer and 200 Ams rated bus FP as incomer and SP/TP as outgoing complete all as specified and directed.
S/F in repair Load line 4 way load line segrigated Vertical type(VTPN DB) DB double door, duly powder coated 415 volt with provision for 125 Amps MCCB as incomer and 200 Amp rated bus FP as incomer and SP/TP as outgoing complete all as specified and directed.
S/F in repair 4way TPN DB double door, duly powder coated 415 volt and 200 Amp rated bus FP as incomer and SP/SPN/TPN as outgoing complete all as specified and directed.
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 12 way DB 240 volts, 100 Amp rated bus bar. complete all as specified and directed.
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 08 way DB 240 volts, 100 Amp rated bus bar. complete all as specified and directed.
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 04 way DB 240 volts, 100 Amp rated bus bar.complete all as specified and directed.
S/F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps.complete all as specified and directed.
S/F in repair DB's MCB's of MCB SP 40 Amp to 63 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings complete all as specified and directed.
S/F in repair DB's MCB's of MCB SP up to 32 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings complete all as specified and directed.
S/F in repair MCB SP & N up to 63 Amp 240 Volts complete all as specified and directed.
S/F in repair MCB SP & N up to 100 Amp 240 Volts complete all as specified and directed.
S/F in repair MCB four pole up to 80 Amp 415 Volts complete all as specified and directed.
S/F in repair MCB TP &N (4P) up to 100 Amp 415 Volts complete all as specified and directed.
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
Description all as per serial item No. 75.00 above but for size 175x100x50 mm deep complete all as specified and directed.
Description all as per serial item No. 75.00 above but for size 200x150x50 mm deep complete all as specified and directed.
Description all as per serial item No. 75.00 above but for size 250x200x50 mm deep complete all as specified and directed.
Description all as per serial item No. 75.00 above but for size 350x200x50 mm deep complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply only Integrel sleek extruded batten aluminium /CRCA channel fitting with LED T8 T/L 20 watt complete with all accessories and including connecting up with three core twisted flexible copper conductor cable with suitable size of 230V, 50 Hz, complete all as specified and directed. Make crompton Cat No DIJB12 LT8 or equivelent in Bajaj or Philips/ wipro ,
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified and directed.
Supply and fixing recess mounted down lighter 6 Watts complete all as specified and directed yellow/white AS Per Sample . complete all as specified and directed.
Supply and fixing LED Street light fittings 30 watt, 220 V AC complete with driver, holders & LED lamp suitable for wall/roof/ ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply only LED bulb Lamp 09 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink.complete all as specified and directed.
Taking down and refixing storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly completet (considered as one unit) and installing and testing the same as per the direction of Engineer-In-Charge.(Supply only for parts against unserviceable parts shall be measured and paid for separately under relavent items given below)
Description all as per serial item No 87.00 above but for capacity 50 ltrs.complete all as specified and directed.
Supply and fix in replacement of heating elements, 1.5/2 KW any type any size ISI mark 230 volts complete all as specified and directed.
Supply & fix for replacement of thermostat immersion point type 15 Amps, 230250 volts/AC ISI marked complete all as specified and directed.
Supply & fix for replacement ,PVC flexible conneciton pipe with brass check nuts complete as per site requirement complete all as specified and directed.
Supply & fix for replacement of indicator lamp assembly for geyser complete all as specified and directed
Supply and fixing earth industrial plug top for socket for industrial socket metal glad suitable for 20 Amps metal glad MCB DB complete all as specified and directed.
Supply and fixing earth industrial socket metal glad suitable for 20 Amps 240 volts metal glad MCB DB complete all as specified and directed.
Supply only FR electrical insulation tape nominal size 0.125mm thickness x1.8 cm width x15 mtr length as IS CODE 1728 As per sample complete all as specified and directed.
S&fix in replacement Plug top 15 Amps 240 Volt. complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230 V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
M&L painting enamel white paint by spraying on ceiling fans/exhaust fan complete in situ with synthetic enamel paint by sprying including filling cavities withfine finishing surface by filler one coat after removing/cleaning all dust/dert etc including taking down/ refixing complete all as specfied and directed Note marking/numbering with MES No/Qtr no included in item rates, no extra payment shoulld be mai for marking/numbering.
M & L for ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
M & L for Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
M & L for Exhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
M & L for Cabin fan 400 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
M & L for air circulator 600 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
M&L Bearinng of celing fan suitable for 1200mm sweep/14mm sweep complete all as specified and directed.
M&L Bearinng of exahust fan 300mm/450mm sweep suitable for 1200mm sweep/14mm sweep complete all as specified and directed.
M&L Bearing air circulator/cabin fan suitable 600mm fan/400mm cabin fan complete all as specified and directed.
S & F MS clamps (Standard size as per site of DJP) with rubber real with MS nut, bolts, check nut & split pin complete all as specified and directed.
S & F fan rod complete all as spcified and directed
S&f 3 PHASE Socket 415 volt complete all as specified and directed
S&f 3 PHASE Top 415 volt complete all as specified and directed
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F flame proof/weatherproof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth switch socket combination socket 16 Amp 240 Volts complete all as specified and directed.
S&F tube light fitting 1 x 20 Watt flame proof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size 4 feet complete all as specified and directed.
Supply and Fix flame proof weather proof sheet metal enclosure single door SPN DB 4 way in cast alluminium alloy LM6 construction comprising of following:- (a) MCB SPN 40 Amps 10KA, 240V-1 No (b) MCB SP 10 Amp 6 KA, 240 V- 2 Nos
S/F flame proof Exhaust fan 300 mm sweep with louvers ,0.25 HP single phase 230 volts 1440 RPM, CFM 1120 ISI marked. complete all as specified and directed.
S/F flame proof ceiling fan 1200 mm sweep single phase 230 volts 1440 RPM ISI marked. complete all as specified and directed.
Supply and fixng Hylam sheet Size 7” x 9”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixng Hylam sheet Size 9” x 6”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixng Hylam sheet Size 6” x 6”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixng Hylam sheet Size 9” x 11”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fix 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances. Role of 90 RM complete all as specified and directed.
Supply and fix driver for 150 watt led flood light any make any type complete all as specified and directed.
Supply and fix driver for 25/30 watt led street light any make any type complete all as specified and directed.
Supply and fix LED flood light 50 watt complete all as specified and directed.
Supply and fix LED flood light 150 watt complete all as specified and directed.
Supply and fix knob as per sample for flame proof switch/DBs complete all as specified and directed.
Supply and fix exhaust fan louvers 450/300 sqmm complete all as specified and directed.
Supply and fix fan blade for ceiling fan 1200mm/1400 mm complete all as specified and directed.
Supply and fix 23/.0076 sq mm 2 core flexible copper cable for maintenance of light/ fan etc. complete all as specified and directed.
S&F 400 watt HVSV lamp complete all as specified and as directed
S&F 400 watt capacitor/codenser for 400 watt HVSV lamp complete all as specified and as directed
S&F 400 watt choke(ballast) suitable for 400 watt HVSV lamp complete all as specified and as directed
Supply and fix Bolard light 10 watt LED based bollard with MS pipe housing with glare free PMMA diffuser,IP65,H= 800 MM complete all as specified and directed. Note Necessary excavation/ cabling work/2 mtr length of wire and PCC work of size 250mm x 250mm x 15 mm included in item rate no extra payment should be made by Department.
S&F PVC pipe/conduit for laying cable/wire with clamp/bend/tee complete all as specified and directed
M&L for Earthing complete as per electrical plate NO.3 of MES SSR Part I with galvanised steel plate earth electrode 600 mm x 600mm x 6 mm burried directly in ground in a pit of depth not less than 2.25 metre below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and incl galvanised iron or steel earth lead wire 4 mm dia by mneans of bolts, nuts, check nuts and washers of galvanised iron or steel earthing wire protected by galvanised iron or steel pipe 15 mm dia light grade and connected to main switch board or main control board watering pipe shall be 20 mm dia GI medium grade incl excavation and earth work in any type of soil, PCC pit, CI Frame, RCC covers complete all as specified and directed.
Shiv Kripa Tradimg
Badri Electricals
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .