Muncipal Commissioner Nadiad
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
272895
07 OF 2025 -26
Open
Civil - All
Works
Kheda
3 documents required · 3 mandatory
₹2,832
MUNICIPAL COMMISSIONER NADIAD MUNICIPAL CORPORATION
₹53,227
4 Feb 2026
4 Feb 2026
4 Feb 2026
13 Feb 2026
4 Feb 2026
Total Amount Rs:-
SR.NO. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1) Structural condition assessment of existing Gate structure 2) Suggesting
neccessary Destructive and Non-destructive testing on brick and core (Testing
shall be done by seperate agency) 3) Checking the suitability of existing
foundations 4) Carrying out structural analysis for Gate and checking stability
and possibility of additional roof. Final output in form of report and drawings
Demolition of Timber members including stacking of serviceable materilas and
disposal of unserviceable materials with all lead and lift.
Raking out joints in lime mortar and preparing the surface for re-pointing or
3.00 replastering, including disposal of rubbish to the dumping ground, all complete 342.72 Sqm 63.52
as per direction of Engineer-in-Charge.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees
and saplings of girth up to 30 cm measured at a height of 1 m above ground
level and removal of rubbish up to a distance of 50 m outside the periphery of
the area cleared.
Surface dressing of the ground including removing vegetation and inequalities
not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift up to
All kinds of soil
Scientific excavation over areas (exceeding 30 cm in depth, 1.50m in width as
well as 10 sqm on plan) upto 1.0m depth around heritage structure without
damaging the burried architectural part of the building including screening
collecting and depositing the usable objects/ articles at the specified place
including getting out the excavated soil and disposal of the source in the
authorised dumping ground as per direction of the Conservation Architect /
Engineer-in-charge
Providing and fixing double scaffolding system (cup lock type) on the exterior
side of building/structure, upto 25 metre height, above ground level, including
additional rows of scaffolding in stepped manner as per requirement of site,
made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal &
vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis,
M.S. clamps and staircase system in the scaffolding for working platform etc.
and maintaining it in a serviceable condition for execution of work of cleaning
7.00 and/ or pointing and/ or applying chemical and removing it thereafter. The 458.30 Sqm 303.00
scaffolding system shall be stiffened with bracings, runners, connecting with the
building etc, wherever required, if feasible, for inspection of work at required
locations with essential safety features for the workmen etc., complete as per
directions and approval of Engineer-in-charge.
Note:- (1) The elevational area of the scaffolding shall be measured for payment
purpose. (2) The payment will be made once only for execution of all items for
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
CIVIL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
Cleaning the sand Brick surface and removing dirt, dust, bird dropping, grease,
oil, algae, fungus, monkey beats, vegetable growth etc., including providing,
applying and washing the surface with liquid Ammonia Chemical of 5% solution
and other chemical cleaning agent as approved byArchaeological Survey of
India/ Engineer-in-charge, of approved brand and manufacturer, with the help
of required scrubbers and also cleaning with machine operated water jet mixed
with desired quantity of fine silica where ever required, without causing any
scratching/ damage to the Brick surface and finally washing the surface with
clean water with the help of pressure jet machine, complete in all respect,
including taking all precautions to safeguard ventilators, windows, doors etc. by
suitable covering so as to avoid any damage to the building/structure, all as per
direction of Engineer in-charge (The rate is inclusive of all materials & labours
involved except scaffolding).
Propping with steel to support the leaned structure (roof and wall) using
9.00 pipes,channels, angles, girders , wooden wages to prevent further leaning/ 20.00 Kg 104.10
Ruled/ Flush pointing on White sand Brick masonry surface with lime and sand
10.00 mortar in the ratio of 1:2 {One Slaked lime : 2 Fine sand}. (The rate is inclusive of 342.72 Sqm 284.30
all materials & labours involved except scaffolding).
Brick consolidation-removing the loose/damaged Bricks and reconsolidating
with new bricks/reusable Brick with lime mortar(1:2) wherever necessary.
Careful re-fixing of the removed Brick Masonry by using rich lime mortar (if
necessary by providing M.S. flat cramps, raking of joints & pointing as per site
condition & instructions/guidance of engineer- in-charge
Traditional Brick work in gauged arches in lime mortar 1:1:1 (1 lime : 1 coarse s
Traditional brick masonry in nanakshahi or lakhori bricks in lime mortar in
similar to the existing traditional lime mortar 1:1:1 (lime :1 surkhi: 1 finesand)
Stone work in masonry in superstructure in lime mortar 1:1:1 (1 lime: 2 coarse
14.00 sand) including pointing with lime mortar and an admixture of pigment 0.50 Cum 17773.20
matching the stoneshade. White Sand Stone
Providing wood work in Trusses, Purling, Rafter, Post,Post Plates, wall plates and
the like wrought framed, hoisted and fixed in position
Appliying priming coat over new wood and wood based surface after and
including preparing the surface by throughly cleaning oil, grease, dirt and other
foreign matter, sand papering and knotting.
(C) Ready mixed paint brushing priming for enamel
Plinth Area Protection using Lime concrete and brick tiles around the building to
prevent entry of water by dampness and capilarry rise
Providing and applying antifungle wash treatment using 3% solution of sodium
pentachlorophenate, of reputed brand and manufecturer, on cleaned sand
18.00 stone surface at desired locations as per direction of Engineer-in-charge (The 342.72 Sqm 106.10
rate is inclusive of all materials & labours involved except scaffolding)
Applying breathable, non-reactive and water repellant Silane/Siloxane chemical
as approved by Engineer-in-charge, of approved brand and manufacture, ready
to use, on the existing sand stone masonry surface with two or more coats to
give uniform application of chemical on the surface, all complete as per
direction of Engineer-In-charge (The rate is inclusive of all materials & labours
involved except scaffolding).
TOTAL AMOUNT RS.:-
TOTAL AMOUNT RS.:-
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
CIVIL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE AMOUNT
Consultanting Civil Engineer City Engineer
DD(OPC) PVT. LTD. Nadiad Municipal Corporation
Ahmedabad Nadiad
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
ELECTRICAL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE
MV Switchgear & Power Panels
Supply, Unloading at site, shifting to site, assembling, leveling, grouting, erecting,
Testing,& Commissioning main L.T. panel board, fabricated from M.S. sheet & folded
channel totally enclosed cubical type compartmentalized. Scope Covers Unloading at Site,
Store in Weather Proof Condition, Shift to the Location Basement/GF/FF,
Grouting, Installation, Testing & Commissioning complete in all respect & As per the
instruction of Architect /Consultant /Engineer Incharge. Scope also covers Co
ordination with Panel Manufacturer.
Design, fabrication, assembling, supply, installation , testing of Panels for 415 V, 3 phase,
50 Hz, 4 wire power supply system.
Panels shall be fabricated out of 2mm thick CRCA sheet steel in cubical formation,
compartmentalized in Form 4b Construction, floor mounted, free standing and shall be
dust and vermin proof. 3 mm thick cable gland plate, shall be provided both at the top
and the bottom of the panel.
All large panels shall be provided with lifting hooks. Distribution panels shall be
fabricated in accordance with the specifications.
Note : Panel vendor has to provide Surge Protection at every stage of the Distribution.
1) Supporting rigid steel framework.
2) Cubicle type, 14 gauge CRCA sheet steel enclosed.
3) Complete with interconnections and distribution bus bars.
4) Proper bonding to earth.
5) Painting/lettering on Breakers and distribution boards, the location they serve,
providing on each panel its circuit diagram.
6) Providing cable clamps / supports within distribution boards cable alley.
7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequate size of neutral
8) All MCB’s shall be of minimum 10 KA breaking capacity.
9) The breaking capacity of MCCB’s are mentioned panel wise.
10) All motor feeders MCCBs shall be of motor duty.
11) Distribution panels shall be Powder Coated with Siemens gray paint shade no. RAL-
12) Degree of protection for following type of distribution panel enclosure shall be as per
a) IP 52 for indoor panels.
b) IP 54 for Service area panels.
c) IP 65 for outdoor panels.
13) All MCCB’s shall be provided with operating mechanism for door interlock & with
the roraty handle
14)Currentdensityofaluminiumshallbe1sqmmfor0.8ampsforratedcurrentofbusbarsandcur
rentdensityofcoppershallbe1sq.mmfor1ampsforratedcurrent
15) Tinned copper earth bus as specified in the BOQ / SLD shall be provided through out
the length of each board.
16) All measuring instruments (Meters) shall be of digital electronic with LED of approved
make and compatible with BAS.
17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
ELECTRICAL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE
17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper wire.
18) All panels shall have provision of the following:
a) IP 55 for outdoor panels.
b) Pad locking of MCCB’s handles in “OFF” Position.
19)AdditionalsetofC.T.s,potential
freecontacts,connectors,contactorswithwiringetcaretobeprovidedforBASincludingspacere
quiredforvarioustransducersin
Main Switch Board sections. Only transducers shall be supplied by BAS contractor.
20) All the C.T.s should be auto short link type.
21) All the MCCB's should be with rotary handle.
22)AllMCB’susedforprotectionofresistiveandlightlyinductiveloadshallbetype“B”characteris
ticandinductive(motor) loadshallbeoftype“C”characteristic and
discharge lamps and UPS etc. shall be of type D characteristic.
23) All incoming and outgoing air circuit breakers shall be placed on middle portion of the
vertical in single tier formation.
24) All PTs / control transformer shall be provided with centre tap earth secondary.
25) IfAnydescripancy found inSLD&BOQ, it shouldbebrought inthenoticeof theClient
/Consultant,Client /Consultant'sdecisionwill befinal incaseofany
26) All outdoor panles should be provided with minimum 600mm height fabrication
stand with all side 2mm thick M.S. powder coated sheet.
26) G.A. Drawing should be checked & Finalised by consultant before fabrication.
SITC of IP 65 External Area lighting Panel
63 amps FP MCB (16 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP MCB's.
3 Nos. of Digital type 0-63 / 5 amps CTR digital ammeter with 3 nos 63 / 5 amps, 15 VA
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall be
protected by 2 amp TP MCB’s
63 amps FP Tinned copper bus bars with coloured heat shrinkable insulated sleeve.
TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 63A FP MCB as per SLD
40 to 63 amps 4 pole MCB ( 10 KA ) : 4 No.
6 to 32 amps FP 4 pole MCB : 2 no.
40 to FP Contactor : 4 no.
Dual channel Timer : 2 nos.
Panel should be as per SLD
All MCB's, ELMCB's, ELCB's should be of 10 KA only
providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and having
breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
ELECTRICAL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the
fault all over the run and backfilling the same and making the surface proper. Providing
and erecting iron clad cable route marker duly marked with ELE.CABLE of size 23 cms.X
12 cms. Flushed with ground in cement foundation as directed by Engineer in charge. The
width shall be as per requirement
Covering of cable with second class bricks laid cover the cable crosswise & also on both
sides with covering of 7. 5 Cms. layer of sand above & below cable (cable shall be laid in
0.9mtr.deep & 0.4 Mtr.wide trench). Where there are more than one cable in the trench
on either side of the cable, 5 Cms. over lapping of bricks shall be provided.
Supply, Installation, Testing, Laying, Commissioning of following 1100 volt grade XLPE
insulated PVC sheathed aluminum / Copper conductor armored cables as per (IS:7098)(I)-
88 ISI marked & specification in trenches, cable trays, ducts, over bed of sand, clamped to
5.00 wall with suitable clamps including, saddles fixing bolts, connecting testing and 50.00 mt
commissioning with identification tags at every 10 mtr. & Both ends. with All the fixing
accessories, excavation Back filling & Cable protection with Bricks as per the drawing ( If
16 sq.mm x 4 c Al. XLPE Arm. Cable
6.00 10 sq.mm x 4 c Al. XLPE Arm. Cable 50.00 mt
Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand copper
conductor for 1.1 KV. To be laid on wall with necessary clamps or in existing trench / pipe
7.00 at road crossing or floor of following size cable. 20.00 mt
6 sq.mm x 3 c cu. XLPE Arm. Cable
Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand copper
conductor for 1.1 KV. To be laid on wall with necessary clamps or in existing trench / pipe
8.00 at road crossing or floor of following size cable. 20.00 mt
4 sq.mm x 3 c cu. XLPE Arm. Cable
Supply & Laying of 1.5 sq mm x 3 core round flexible wire in prelaid pipe / Raceway.
Supply & Laying of 2.5 sq mm x 3 core round flexible wires in prelaid pipe / Raceway.
Supply & Laying of 4 sq mm x 4 core round flexible wires in prelaid pipe / Raceway.
Cable Termination
SITC of Cable end termination of the following XLPE insulated PVC sheathed
aluminum/copper conductor armored cables of 1100 volt grade including supplying and
fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with
16 sq.mm x 4 c Al. XLPE Arm. Cable
13.00 10 sq.mm x 4 c Al. XLPE Arm. Cable 2.00 no
SITC of Cable end termination of the following XLPE insulated PVC sheathed
aluminum/copper conductor armored cables of 1100 volt grade including supplying and
fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with
6 sq.mm x 3 c Al. XLPE Arm. Cable
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
ELECTRICAL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE
SITC of Cable end termination of the following XLPE insulated PVC sheathed
aluminum/copper conductor armored cables of 1100 volt grade including supplying and
fixing of bimetallic Long neck crimping lugs, double compression type Brass glands with
4 sq.mm x 3 c Al. XLPE Arm. Cable
SITC of Round Flexible wire end termination of the following insulated PVC sheathed
copper conductor Wires of 1100 volt grade including supplying and fixing of bimetallic
Long neck crimping lugs, IP66 / 67 - 3 mm thick Thermoplastic long entry glands of Hensel
/ Spelsberg with Strain relief and Lock nut.
1.5 / 2.5 Sq. mm x 3 / 4 core round flexble wire or Similar dia wire
17.00 4 / 6 Sq. mm x 3 / 4 core round flexble wire or Similar dia wire 2.00 no
SITC of Outdoor Architectural LED surface mounted flood light luminaire with system
Wattage 18W/36W/50W (±5%), Available in 5700K/4000K/3000K/2700K CCT with System
Efficacy not less than 80Lm/W, Clear Optics with Narrow/Medium/Wide Distribution,
Available Beam Angles Options 10°/30°/60°, UV Stabilized PMMA Secondary Lens Optics,
Front Toughened Glass Enclosure with high grade silicon Gasket ensuring IP Protection,
CRI>80, THD<5%, PF>0.9. LED life 50,000 BHRS@L70, PDC Aluminium Alloy housing for
optmium thermal management, Light Engine PCB should be Metal Core PCB made of
high grade Al 5052 with 270 micron copper thickness & 2 W/mk thermal conductivity for
better thermal maintanance for light Engines. Corrosion resistant Nano technology
power coating of Silver Grey/Black Color/Terracota Red (As per selection by Dept. or
Architect) Luminaire has a Ingress protection of IP66 and Impact Resistance of IK08.
Integral encapsulated high efficiency electronic driver having a with rated voltage of 100-
270V AC, Inbuilt surge protection of 4KV L-L, 6KV L-E with with all necessary safety
18.00 protection like mis-wiring, Over voltage, Short circuit. Reverse Polarity protection. 8.00 no
Suitable for Surface/Wall mounting with Inbuilt Adjustable base. IES. LM 79. LM 80, & TTC
certificates will be provided from NABL accredited lab. Luminaire performance & Safety
Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification
for Luminaires & Drivers Manufacturer should have their own NABL accredited testing
laboratory for EMI-EMC test, Vibration, compatibility test, Salinity spray test, wind load
pressure test, IP / IK test, Powder coating facility, in house casting plant, robo-
photometric laboratory and Driver manufacturing facility, SMT line in India. The
Manufacturer Name and Logo should be engraved / Embossed on the housing/body to
allow traceability till the life of the fixture, No sticker will be accepted Luminaires
specified in the luminaire should have BIS certificate. Manufacturer should have
Certification pertaining to product DesignRegistration, CE certifications, ROHS compliant,
BIS certificate for drivers and luminaires respectively
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or approved
make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection
terminal dia of 14 mm with constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following type of applications.
For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing,
A.C.Plant & Sensitive Computer System(like Automation, SCADA)i.e. independent
Earthing located in other than normal soil i.e. Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
NADIAD MUNICIPAL CORPORATION - NADIAD
DISTRICT :- KHEDA
BID DOCUMENT FOR PROPOSED RESTORATION AND CONSERVATION WORK OF MARIDA GATE FOR NADIAD MUNICIPAL CORPORATION, NADIAD.
ELECTRICAL WORK FOR CONSERVATION WORK OF MARIDA GATE
SR.NO. ITEM DESCRIPTION QTY UNIT RATE
Earth wire/strips :
Supply and laying cu. earthing strips for interconnecting the earthing stations, panels,
DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and
20.00 shown on drawings complete with : fixing accessories 20.00 kg
Corrosion protection of buried conductors with bituminous coating and covered with PVC
Providing and erecting HOT deep Galvanized strip iron wire 8 to 16 S.W.G.
21.00 25 x 3 mm cu. Tape 20.00 kg
22.00 No.8 gauge bare cu. earth wire 20.00 kg
SITC of Water Tight Junction Box of Hensel make Cat. No. KG9003IN With necessary
23.00 clamp for mounting of the J.B. ( All the cable / wire connections to the JB shall be with 2.00 no
the Water tight Glands only )
Providing & laying. Double walled corrugated pipes (DWC) of polyethylene(conforming to
IS 14930 II ) Anti Rodent type with necessary connecting accessories of same material at
required depth for laying of cable. below ground / road surface for enclosing cable and
backfilling the same to make ground as per original.
TOTAL AMOUNT RS.:-
TOTAL AMOUNT RS.:-
Consultanting Civil Engineer City Engineer
DD(OPC) PVT. LTD. Nadiad Municipal Corporation
Ahmedabad Nadiad
L CORPORATION, NADIAD.
L CORPORATION, NADIAD.
L CORPORATION, NADIAD.
L CORPORATION, NADIAD.
L CORPORATION, NADIAD.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01.00_TENDER NOTICE.pdf
02.00_SCHEDULE B.pdf
03.00_TECHNICAL SPECIFICATIONS.pdf
03.01_SPECIFICATIONS ELECTRICAL WORK 02.pdf
03.02_A_P-1_GENERAL TECHNICAL SPECIFICATION _ELECTRICAL -1-33.pdf
03.03_A_P-2_GENERAL TECHNICAL SPECIFICATION _ELECTRICAL -34-63.pdf
03.04_GENERAL TECHNICAL SPECIFICATION BOOKLET_CIVI WORK.pdf
04.00_DRAWINGS.pdf
05.00_testing 80 20 10 and in govt degree polytechnic college 17.05.2019.pdf
06.01_GR_P-1_.pdf
06.02_GR_P-2.pdf
06.03_GR_P-3.pdf
06.04_GR_P-4.pdf
07.01_GR DOC 1_compressed.pdf
07.02_DMO 2799 11-Mar-2024 662.pdf
08.00_VENDOR LIST.pdf
09.00 SCHEDULE FOR TESTING MATERIALS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .