Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.1 CrAccepted-AOC | ₹7.1 Cr | 1 | Accepted-AOC L1 |
Tender Value
₹7.4 Cr
EMD Value
₹2 L
Closing Date
13 Nov 2023, 3:00 pmClosed
SUPERINTENDING ENGINEER
PH CIRCLE, KWA, MALAPPURAM
JJM - Improvements of CARWSS to Moorkkand and Adjoining Panchayaths -Package - XII - Supply and erection of RW CW pumpsets booster pumpset Trannsformer at WTP wiring of RWPH power line extension and power connection works-General Electrical Work
2023_KWA_617095_1
SE/PHC/MPM/180RE/2023-24
Open Tender
Civil Works - Water Works
Item Rate
270 days
Moorkanad
Refer tender documents
8 documents required · 8 mandatory
₹11,025
₹2 L
PH CIRCLE, KWA, MALAPPURAM
16 Apr 2024
28 Oct 2023
14 Nov 2023
28 Oct 2023
13 Nov 2023
1 Nov 2023
28 Oct 2023 - 1 Nov 2023
1 Nov 2023
Amount
Appendix A - Supply and Installation of 630 KVA Transformer at Raw water Pump house
OD91944/2023-2024:Fabrication, Supply and Erection of 11 KV 2 pole structure as per standards made out of ISMB 175x85mm joist of 10mtrs. Length and cross members of ISMC 100x50mm MS channels and fitted with following equipments '0' SWG solid copper conductors shall be used for all jumber connections from suppliers AB switch to transformer through various equipments. the post has to be fixed 1.6M below ground level using 1:3:6 cement concrete as per standard , 300x300x6mm MS plate shall be welded to all poles as base plate. including fixing suitable bolts and nuts etc. complete and the pole structure consist the following:- 11 KV 400A 3pole 3 insulator type Gang operated AB switch with operating rod and handle with pad lock arrangement - 1 sets. 11KV 30/60A 3pole DO fuse with element - 1 sets. 9KV 5KA lighting arrestor - 1 Sets. 11KV disc type insulator with all hard wares - as required 11KV pin type insulator - 6 Nos. and inter connections of the above items using 8mm dia solid copper conductor with proper copper sockets , including all associated civil works and painting of all structurers with two coats of zinchromate primer and aluminium paint etc. complete including earthing, as per standard construction practices approved by Kerala Electrical Inspectorate and relevant standards
OD91945/2023-2024:Supply of all materials and providing substation yard fencing using 50 x 50 x 6mm angle iron frame work of size 1500x2500mm fitted with weld mesh of 10 gauge and bolted the same to 100 x 50 x 6 mm vertical chanel erected at 1500mm c/c and 2500mm above ground level of substation yard and 500 mm below with 300 x300mm plain cement concrete (1:3:6) base using 40 mm granite aggregate and top surface finished neat including supply and spreading of river sand to a depth of 5 cm from ground level and spreading 40mm granite metal over this to a height of 10cm above grond level for the entire yard area with side protection using cement brick. Including excavation of soil, painting all metal parts with two coats of aluminium paint over two cots of epoxy primer
OD91946/2023-2024:Supply of all materials and providing 2000mm wide 2500mm height weld mesh gate made out of 50 x 50 x 6mm Angles with necessary foundation, Locking arrangements etc. complete, including painting with two coats of zinchromate primer and aluminium paint as per standards.
OD91947/2023-2024:11KV Metering Unit Supply,erection, testing and commissioning of out door type metering unit consisting of the following accessories: Current Transformer CT Ratio 20/5 A (actual ratio may be decided after calculating connected load& maximum demand) Burden 15VA Accuracy Class 0.2S Potential Transformer PT ratio 11KV/110V Burden -100VA. Accuracy Class 0.2 The rate shall include the cost of testing the equipment at KSEB and all other incidental expences. The CT ratio should be fixed only after obtaining the power allocation from KSEB 11 KV Metering Unit
OD91948/2023-2024:TOD Meter Supply,erection, testing and commissioning of TOD meter with maximum demand in KVA suitable for the above out door metering set housed in a weather proof out door Kiosk includig supply and errection of the kiosk with suitable foundation. The TOD meter shall satisfy KSEB specifications in force.The rate shall include the cost of testing the equipment at KSEB and all other incidental expences and supply and connecting cable from CTPT to metering equipment. TOD Meter
OD91949/2023-2024:11KV Switchgear (Indoor) Supply, erection, testing and commissioning of 11KV, 400A, 350MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type vacuum circuit breaker 3 panel system (1 no. VCB as incomer and 2 nos VCB as out going ) suitable for installation in 3 phase , 3wire, 50Hz. AC,11kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanism and 11kV PT, CT, all metering equipments (A,V, KW, PF), Microprocessor based digital transformer protection relays of reputed make etc. complete as approved by Kerala Electrical Inspectorate and relevant standards. Armoured multi core 2.5 sqmm copper constrol cables shall be used for all external & internal interconnections. The cost of control cables both internal and external shall be included in the cost of HT Panel. 11KV Switchgear(Indoor)
OD113443/2023-2024:Supply,erection, testing and commissioning of 630 KVA, 11KV/433 V. 3phase, 50Hz. ONAN cooled , indoor type copper wound power transformer, with HV side and LV side cable entry box arrangements, on load tap changer with 17 tap positions having +5% to -15% variations in1.25% steps with OLTC/RTCC panel with AVR control relay and local & remote indication of tap position, and including first filling of oil , earthing etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of neutral grounding CT, control cables both internal and external and RTCC panel shall be included in the cost of Transformer etc.complete as per IS specification
OD113509/2023-2024:Supply installation testing and commissioning of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.6 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar, detachable covers for bus bar chamber and cable alley, continuous earth bus at the bottom of the panel etc. complete as approved by Kerala Electrical Inspectorate and relevant standards , powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Incomer: 1000A, MDO ACB with 3O/C+1E/F - 1 Nos. Low set earth fault relay (EFR)for incomer, Digital Multifunction meter to read V,A,F,PF, etc. Indicator sets with necessary accessories and panel should be fully wired. Busbars: 1000A Aluminium TPN. Outgoings: (1) :Microprocessor based 400A 36 kA 3P MCCB - 4 Nos.(3 Nos interlocked with each other 2 nos working at ta time, & 1 spare) , (2) 250A 25kA 4P MCCB - 1 Nos, (3) 63A 4P MCCB 1 No, with Digital multifunction meter with display for KW, V, A and pf for all outgoing feeders
OD113635/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113636/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113637/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113638/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113639/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113640/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113641/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113642/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113643/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench
OD113644/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113645/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113646/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 3.15mm copper wire
OD113647/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113521/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113522/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113523/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113524/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HTBreaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113525/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor)
OD113526/2023-2024:EARTHING - Supply and providing plate earhing as per IS 3043 by using 600mm x 600mm x 3mm thick copper plate with 2.7mtrs. Long 20mm dia 'B' class GI watering pipe extended upto middle of copper plate and clamped to the plate by usig 3 nos. GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 no. earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earh bus with copper plate by using 2 nos. 25x6mm copper strip of suitable length, filling charcoal and salt at alternate intervels of 15cm all aournd Copperplate. Providing masonry earth pit chambers of suitable size and covering with R.C.C/ CI chamber cover etc. complete. ( For 4 pole, transforner body and neutral, HV, LT & 3.3 KV Panel, Starter panel, Motor, Lighting etc) RW, WTP, CW, Booster
OD113527/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc
OD113528/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
OD113529/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
OD113530/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
OD113531/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
OD113533/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc.
Appendix B - Supply and Installation of 750KVA Transformer for Clear Water pump house at WTP compound
OD91960/2023-2024:750KVA Transformers (Outdoor type ) (for CW pumpsets) Supply,erection, testing and commissioning of 750 KVA, 11KV/3300 V. 3phase, 50Hz. ONAN cooled , outdoor type copper wound power transformer, with HV side and LV side cable entry box arrangements, on load tap changer with 17 tap positions having +5% to -15% variations in1.25% steps with OLTC/RTCC panel with AVR control relay and local & remote indication of tap position, and including first filling of oil , earthing etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of neutral grounding CT, control cables both internal and external and RTCC panel shall be included in the cost of Transformer. construction of suitable R.R. Masonry plinth for accomadating transformer etc.complete as per IS specification
OD91961/2023-2024:NGR -Neutral grounding resistor Design,engineering, supply erection,testing and commissioning of indoor type 3.3KV stainless steel make Neutral Grounding Resistor in sheet steel enclosure with IP 23 degree protection with siutable neutral CT for REF protection. The cubicle shall be fabricated out of 2.5mm sheet steel and painted with anti –rust primer coating followed by two coats of paint of approved shade, as per standards. The NGR shall be of CEA and Kerala Electrical Inspectorate and relevant standards. 2.5 Sqmm copper control cable shall be used for all external interconnections. Cost of control cable and termination shall be included in the cost of NGR panel 750KVA Transformers (Outdoor type ) (for CW pumpsets)
OD91962/2023-2024:PANEL BOARDS - HV Panel board ( for 750 KVA transformer ) 3.3 KV- Supply, erection, testing and commissioning of 3.3KV, 200A, 75MVA, totally enclosed, single bus bar, floor mounting in metal clad, indoor extensible type flush mounted horizontal isolation and drawout type panel board comprising of onevacuum circuit breaker as incomer, 3 No 200 A, 75MVA 3.3KV VCBs as outgoing, incomer switchgears & outgoing switchgears are drawout type, trip free VCBs suitable for installation in 3 phase , 4wire, 50Hz. AC, 3.3kv, effectively earthed supply system,comprising of motorised and spring assisted, independent, trip free closing mechanisum and PT and CT for metering and protection, metering equipments indicating V, I, KW, PF ,numerical protective relays of reputed make, all accessories etc. complete as approved by CEA and Kerala Electrical Inspectorate and relevant standards. 2.5 Sqmm copper control cable shall be used for all internal interconnections. PANEL BOARDS - HV Panel board ( for 750 KVA transformer ) 3.3 KV
OD91963/2023-2024:Supply,erection, testing and commissioning of 200KVA, 11KV/433 V. 3phase, 50Hz. ONAN cooled , outdoor type copper wound power transformer, with HV side and LV side cable entry box arrangements, on load tap changer with 17 tap positions having +5% to -15% variations in1.25% steps with OLTC/RTCC panel with AVR control relay and local & remote indication of tap position, and including first filling of oil , earthing etc. complete with all fittings as per IS 2026 and Kerala Electrical Inspectorate standards. Armoured multi core 2.5 Sqmm copper control cables shall be used for all external & internal interconnections . The cost of neutral grounding CT, control cables both internal and external and RTCC panel shall be included in the cost of Transformer. construction of suitable R.R. Masonry plinth for accomadating transformer etc.complete as per IS specification 200KVA 11KV/433V Transformer
OD91964/2023-2024:Supply installation testing and commissioning of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.6 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar, detachable covers for bus bar chamber and cable alley, continuous earth bus at the bottom of the panel etc. complete as approved by Kerala Electrical Inspectorate and relevant standards , powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. Incomer: 320A 4P 50 kA, Microproccessor based MCCB with 3O/C+1E/F - 1 Nos. Low set earth fault relay (EFR)for incomer, Digital Multifunction meter to read V,A,F,PF, etc. Indicator sets with necessary accessories and panel should be fully wired. Busbars: 400A Aluminium TPN. Outgoings: (1) :Microprocessor based 160A 36 kA 4P MCCB - 1 Nos. , (2) 100A 25kA 4P MCCB - 3 Nos with Digital multifunction meter with display for KW, V, A and pf for all outgoing feeders
OD91965/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 3c 150sqmm XLPE 11KV
OD91966/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 3c 185sqmm XLPE 3.3KV
OD91967/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 3c 95 sqmm XLPE 3.3KV
OD91968/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 1c 95 sqmm XLPE 3.3KV
OD91969/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 3.5c 120sqmm XLPE 1100V
OD91970/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 3c 70sqmm XLPE 1100V
OD91971/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 3c 50sqmm XLPE 1100V
OD91972/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 4c 25sqmm XLPE 1100V
OD91973/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 4c 16sqmm XLPE 1100V
OD91974/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 4c 10sqmm XLPE 1100V
OD91975/2023-2024:Supply, laying, testing and commissioning of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable (1100 volts/3.3kv/11kv grade) clamped on wall/ceiling with clamps and saddle clips partly laid in cable tray/partly laid in trench 4c 6sqmm XLPE 1100V
OD91976/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 3 core 150sq mm11kv, XLPE ALUG Cable (AB to HT Panel and to Transformer )
OD91977/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 3c 185sqmm XLPE 3.3KV
OD91978/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 3c 95 sqmm XLPE 3.3KV
OD91979/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 1c 95 sqmm XLPE 3.3KV
OD91980/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 3.5c 120sqmm XLPE 1100V
OD91981/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 3c 70sqmm XLPE 1100V
OD91982/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 3c 50sqmm XLPE 1100V
OD91983/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 4c 25sqmm XLPE 1100V
OD91984/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 4c 16sqmm XLPE 1100V
OD91985/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 4c 10sqmm XLPE 1100V
OD91986/2023-2024:Supply of all materials and providing end termination of the following size PVC/XLPE insulated, sheathed armoured Aluminium conductor cable ( 1100 volts & 3.3/11kv grade ) for giving power connections to HT Breaker, Transformers, Panel boards etc. complete as per standards. ( indoor and outdoor) 4c 6sqmm XLPE 1100V
OD91987/2023-2024:EARTHING - Supply and providing plate earhing as per IS 3043 by using 600mm x 600mm x 3mm thick copper plate with 2.7mtrs. Long 20mm dia 'B' class GI watering pipe extended upto middle of copper plate and clamped to the plate by usig 3 nos. GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 no. earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earh bus with copper plate by using 2 nos. 25x6mm Copper strip of suitable length, filling charcoal and salt at alternate intervels of 15cm all aournd Copper plate. Providing masonry earth pit chambers of suitable size and covering with R.C.C/ CI chamber cover etc. complete. ( For 4 pole, transforner body and neutral, HV, LT & 3.3 KV Panel, Starter panel, Motor, Lighting etc) RW, WTP, CW, Booster
OD91988/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc 25x6mm copper strips.
OD91989/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x3mm copper strips.
OD91990/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x6mm GI strips.
OD91991/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 25x3mm GI strips.
OD91992/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 3.15mm copper wire
OD91993/2023-2024:Supply, laying and termination of the following sizes of copper strip/wires for earthing of substation, transformers, HTpanel boards,LT panel boards, equipments and inter connection of earth pits etc. 4MM COPPER WIRE
OD91994/2023-2024:Supply and fixing of 6mm thick chequered plate with required M.S. angle/plate supports over the masonry cable trench at substation and electrical control room. Angle and plate should be painted one coat of primer and two coats of enamel paint as required.
OD91995/2023-2024:Supply and fixing of M.S. angle cable tray for clamping the various sizes of cables in trenches, through walls, & trusses etc. as per KEI standards.
OD91996/2023-2024:Supplying, fixing, testing and commissioning of Lead acid cell battery suitable voltage and capacity according to control voltage of panels and other equipment’s capacity at 10hrs rate of discharge assembled with plante positive and pasted negative plates with inter cell, inter raw, interior connectiors etc. stand and cell insulators, sealed floats, nuts, bolt, washersetc with electrolyte of specific gravity 1.190 and accessories such as voltmeter, Thermometer, Hydrometer, spaners etc with teak wood stand with 3 coats of antiacid paint to accomodate battery. WTP & RW
OD91997/2023-2024:Supplying, fixing, testing and commissioning of automatic twin battery charger with distribution board with all instruments and protective devices etc. Complete as per standards. WTP & RW
OD91998/2023-2024:Supply and providing the following safety items approved by Kerala Electrical Inspectorate and relevant standards.(11kv Rubber Mat- 8sets, 11 KV rubber glove-2 set, 11 KV danger board-10set, Fire bucket with stand-5 set, First aid box - 3 set, Shock treatmernt chart-4 sets, 5kg CO2 fire extinguisher 4 sets, 5kg dry powder fire extinguisher - 2 set
OD91999/2023-2024:Internal and External Lighting provisions including MCB distribution boards, modular switch boards, wiring, fans, exhaust fans, external and internal lighting fixtures etc complete with earthing and RCCB (clear water, Raw water, sump, substation yard)
OD92000/2023-2024:Provision for soil resistivity measurement , earthing design, making electrical scheme drawing and getting approval from statutory bodies like electrical inspectorate and KSEBL( fees and other remittances will be made by KWA) Raw water, WTP and CW
Appedix C - Supply and errection Raw water pumpset From Intake at Mothikkayam to WTP at Keezhumuri
OD92058/2023-2024:Motor: Supply , erection , testing and commissioning of KWA pre-qualified reputed make vertical solid 220hp 50hp TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply , working voltage 415 V. The motor shall confirm to EEF1/ IS 325 including providing suitable Non reversible ratchet mechanism for the Motor and VT Pump
OD92059/2023-2024:Supply, erection, testing and commissioning a complete integrated FCMA/soft starter panel capable of operating the motor( 220 HP VT Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V(for 440V supply) . the standared is to be IEC 60947-4-2
OD92060/2023-2024:Design,supply, erection, testing and commissioning of APFC capacitior panel having suitable capacity and voltage for power factor compensation for motors to achieve a power factor 0.98 or higher at any combination of running of pumpsets and shall be fitted with digital APFC controller of reputed make with 3phase current and voltage measurement, pf display(3 digit after decimal), individual harmonics measurement, front panel setting keys for power factor and other settings . The capcitor should confirm to IS 2834-1986. 433 volts as the case may be. The swiching of capacitor shall be with capacitor duty contactor. The panel shall have indication for capacitors in service and instantaneous power factor value. Suitable for running 3 motors, but 2 nos at a time. Suitable capacity reactor also shall be incorporated in the panel to limit the switching current of the capacitors
Appendix D - Supply and errection of Clear water pump set From WTP at Keezhumuri to Proposed Moochikkal OHSR
OD92075/2023-2024:Motor: Supply , erection , testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted 270hp TEFC star rated energy efficient squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply , working voltage 3300 V. The motor shall confirm to EEF1/ IS 325 including providing suitable Flexible coupling for the Motor and CF Pump
OD92076/2023-2024:Supply, erection, testing and commissioning a complete integrated FCMA/soft starter panel capable of operating the motor( 270hp CF Pump set,3phase AC 3300 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 7600V(for 3300V supply) . the standared is to be IEC 60947-4-2
OD92077/2023-2024:Design,supply, erection, testing and commissioning of APFC capacitior panel having suitable capacity and voltage for power factor compensation for motors to achieve a power factor 0.98 or higher but below 1.0 at any combination of running of pumpsets and shall be fitted with digital APFC controller of reputed make with 3phase current and voltage measurement, pf display(3 digit after decimal), individual harmonics measurement, front panel setting keys for power factor and other settings . The capcitor should confirm to IS 2834-1986. 3300 volts as the case may be. The swiching of capacitor shall be with capacitor duty contactor. The panel shall have indication for capacitors in service and instantaneous power factor value. Suitable for running 3 motors, but 2 nos at a time
OD93008/2023-2024:Supplying an electro-magnetic flow meter conforming to protection level of IP-68 for FLow Sensor and IP- 67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit.The flow meter should have the housing (Flow sensor) to be made of SS304/Carbon steel with anticorrossive protection and inside liner to be made of Hard rubber /neoprene all conforming to drinking water standards.The flow meter should be coupled with HART for data acquisition and transfer,with provision for wireless transfer through GSM.The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions.-Suitable for 600 mm Clear water pumping main.
Appendix E - Supply and errection of Clear water pump set From Sump to Proposed 13.5 LL OHSR at WTP Compound
OD92102/2023-2024:Motor: Supply , erection , testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted 40hp TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply , working voltage 415 V. The motor shall confirm to EEF1/ IS 325 including providing suitable Flexible coupling for the Motor and CF Pump
OD92103/2023-2024:Supply, erection, testing and commissioning a complete integrated soft starter panel capable of operating the motor( 40hp CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V(for 433V supply) . the standared is to be IEC 60947-4-2
OD92104/2023-2024:Design,supply, erection, testing and commissioning of APFC capacitior panel having suitable capacity and voltage for power factor compensation for motors to achieve a power factor 0.98 or higher but below 1.0 at any combination of running of pumpsets and shall be fitted with digital APFC controller of reputed make with 3phase current and voltage measurement, pf display(3 digit after decimal), front panel setting keys for power factor and other settings . The capcitor should confirm to IS 2834-1986. 433 volts as the case may be. The swiching of capacitor shall be with capacitor duty contactor. The panel shall have indication for capacitors in service and instantaneous power factor value. Suitable for running 2 motors, but 1 nos at a time
Appendix F - Supply and errection of Clear water pump set from New Moochikkal tank to Kuzhaparmbu
OD92175/2023-2024:12281 Motor: Supply , erection , testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted 70hp TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply , working voltage 415 V. The motor shall confirm to EEF1/ IS 325 including providing suitable Flexible coupling for the Motor and CF Pump
OD92176/2023-2024:Supply, erection, testing and commissioning a complete integrated soft starter panel capable of operating the motor( 70hp CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V(for 433V supply) . the standared is to be IEC 60947-4-2
OD92177/2023-2024:Design,supply, erection, testing and commissioning of APFC capacitior panel having suitable capacity and voltage for power factor compensation for motors to achieve a power factor 0.98 or higher but below 1.0 at any combination of running of pumpsets and shall be fitted with digital APFC controller of reputed make with 3phase current and voltage measurement, pf display(3 digit after decimal), front panel setting keys for power factor and other settings . The capcitor should confirm to IS 2834-1986. 433 volts as the case may be. The swiching of capacitor shall be with capacitor duty contactor. The panel shall have indication for capacitors in service and instantaneous power factor value. Suitable for running 2 motors, but 1 nos at a time
Appendix G - Supply and errection of Clear water pump set from New OHSR at Moochikkal to Existing and new tank at perinthattiri
OD92182/2023-2024:Motor: Supply , erection , testing and commissioning of KWA pre-qualified reputed make horizontal solid shaft foot mounted 50hp TEFC squirrel cage induction motor suitable for the above pump working on 3 phase 50 Hz AC supply , working voltage 415 V. The motor shall confirm to EEF1/ IS 325 including providing suitable Flexible coupling for the Motor and CF Pump
OD92183/2023-2024:Supply, erection, testing and commissioning a complete integrated soft starter panel capable of operating the motor( 50hp CF Pump set,3phase AC 415 V, 50 Hz) having a protection level of IP 40 or more with integrated bypass contactor in the panel and digital motor protection relay of reputed make having parameters as per IE rules, with a power control contactor and line power contactor, and the staring current shall be 2.5 to 3.5 times the normal full load current of motor with Ammeter, Voltmeter, KW, pf meter and phase indicators, Space heaters, floor mounting type and having insulation level of 1100V(for 433V supply) . the standared is to be IEC 60947-4-2
OD92184/2023-2024:Design,supply, erection, testing and commissioning of APFC capacitior panel having suitable capacity and voltage for power factor compensation for motors to achieve a power factor 0.98 or higher but below 1.0 at any combination of running of pumpsets and shall be fitted with digital APFC controller of reputed make with 3phase current and voltage measurement, pf display(3 digit after decimal), front panel setting keys for power factor and other settings . The capcitor should confirm to IS 2834-1986. 433 volts as the case may be. The swiching of capacitor shall be with capacitor duty contactor. The panel shall have indication for capacitors in service and instantaneous power factor value. Suitable for running 2 motors, but 1 nos at a time
OD93009/2023-2024:Supplying an electro-magnetic flow meter conforming to protection level of IP-68 for FLow Sensor and IP- 67 for transmitter and having an accuracy level of 0.5% with LED/LCD Display unit.The flow meter should have the housing (Flow sensor) to be made of SS304/Carbon steel with anticorrossive protection and inside liner to be made of Hard rubber /neoprene all conforming to drinking water standards.The flow meter should be coupled with HART for data acquisition and transfer,with provision for wireless transfer through GSM.The manufactures should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions.-Suitable for 350 mm Clear water pumping main
Appedix H - Electrical wiring works of Raw Water, CW and Booster pump houses Moochikkal
OD92325/2023-2024: Wiring for light point/fan point/ exhaust fan point with 1.5 square mm FRLS PVC insulated copper conductor single core cable in surface/r recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing point with 1.5 sq.mm. FRLSPVC insulated copper cunductor single core cable etc as required. Group C. Point wiring
OD92326/2023-2024: Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable existing surface/ recessed steel/PVC conduit as required. 3x1.5. circuit main
OD92327/2023-2024: Supplying and drawing following sizes of FRLSPVC insulated copper conductor, single core cable in the existing surface /PVC conduit as required.3x2.5 sq.mm. circuit main
OD92328/2023-2024: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recees including cutting the wall and making good in the same in case of recessed coduit as required.25 mm circuit main, power plug
OD92329/2023-2024: Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recees including cutting the wall and making good in the same in case of recessed coduit as required. 32 mm 1. 21. 3 circuit main, power plug
OD92330/2023-2024: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 amps switch 1.24.1
OD92331/2023-2024: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet. 1.24.4
OD92332/2023-2024: Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 1.26
OD92333/2023-2024: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 amp switch 1.24.3 power plug
OD92334/2023-2024: 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6 pin 15/16 amp socket outlet. 1.24.5 Power plug
OD92335/2023-2024: Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Industrial plug
OD92336/2023-2024: Supplying and fixing 32 amps, 240 volts, SPN industrial typed fixing 3, socket outlet, with 2 pole and earth,metal enclosed plug top along with 32 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Industrial plug
OD92337/2023-2024: Supplying and fixing following size/modules,GI box along with modular base & cover plate for modular switches in recess etc as required .1 or 2 module (75mmx75 mm) 1.27.1 indipendent plug
OD92338/2023-2024: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)1.27. 3 indipendent plug
OD92339/2023-2024: 1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.<br> 6 Module (200mmX75mm) Refer Price Data 1.27.4 Price OEO<br> indipendent plug
OD92340/2023-2024: Wiring for powerplug with 2x4 1x4 sq. mm earth wire 1.7.3 Industrial plug
OD92341/2023-2024: Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)1. 27. 6
OD92342/2023-2024: 1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.Refer Data 1.58 Price OEO<br>
OD92343/2023-2024: CHARGES FOR CUTTING HOLES SUITABLE FOR ACCOMADATING EXHAUST FAN ABOVE 305 MM SWEEP AND UP TO 450 MM SWEEP INCLUDING PLASTERING COLOR WASHING ETC AS REQUIRED.
OD92344/2023-2024: 90.4.10 Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan.Refer Data 9.4.10 Price OEO
OD92345/2023-2024: supply of 450 mm sweep, 900 rpm Heavy Duty Exhaust fan working on 230 V A/C
OD92346/2023-2024: 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C
OD92347/2023-2024: Conveyance, installation, testing and commissioning of wall mounting fans of all types using mounting brackets supplied along with the fan.
OD92348/2023-2024: Supply of 300 mm sweep Wall Mounting fan
OD92349/2023-2024:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
OD92350/2023-2024:Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V/240V single phase A/C
OD92351/2023-2024:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 2.5m wall fittings for Street light
OD92352/2023-2024:Supply and fixing of 36/40 W, 4000 lumen LED, IP 66 street light fitting , RoHS compliant, LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, stove enameled CRCA sheet steel reflector cover, acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer
OD92353/2023-2024: 90.3.19.3 Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required 1200 mm 1X20W LED Lamp with box type fixture Refer Data 90.3.19.3 Price OEO<br>
OD92354/2023-2024: Supply, Installation with light fittring of approved brand aesthetic look 20/18 W LED ceiling light
OD92355/2023-2024: Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 4 way (8 + 12) - double cover TPN vertical DB with provision for fixing MCB as incomer and SP/ TP MCB as outgoing (IP 42/43)
OD92356/2023-2024: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 8 way, Double door
OD92357/2023-2024: Supply and installation of 63A 100 mA 4P RCCB in the existing DB complete with connnections,testing and commisioning etc
OD92358/2023-2024: Supply and installation of 25A 30 mA 2P RCCB in the existing DB complete with connnections,testing and commisioning etc
OD92359/2023-2024: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
OD92360/2023-2024: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD92361/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. DP Isolator 40A
OD92362/2023-2024:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 4P Isolator 63A
OD92363/2023-2024:Supply erction testing and commissioning of 100W LED steet light output > 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor >0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD <10%, power factor >0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD92364/2023-2024:Supplying, erection and testing steel tubular swaged poles as per IS 2713 (Part II) - 1980 of height 7.5M above ground level and 1.5M below ground level bottom 139.7 mm dia and 114.3 mm dia for middle and 88.9 mm dia for top including providing base plate providing concreting in foundation, construction of pillar accomodating fuse and switch housed in weather proof box including wiring to the light fitting with 2 runs of 3/20 PVC insulated copper conductor. Supplying and fixing a 4 way 30 A rated terminal block include the weather proof box. The pole shall be painted with one coat of primer and two coats of enamel paint as required by the Engineer in charge.
Bidder Name
Poweron Technologies
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .