Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-Finance | L1 | Accepted-Finance Being L1 | |
| 2 | L2₹23.7 L+₹3.8 L (19.4%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹24.0 L+₹4.2 L (21.3%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹27.9 L+₹8.1 L (40.8%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹29.3 L+₹9.5 L (48.1%)Rejected-Finance FLAT NO 305 SUBBARAO RESIDENCY THENNETI NAGAR MURALI NAGAR VISAKHAPATNAM 07 | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | SREE GAYATRI INFRA L5 | M/s Jai Ganesh Engineering Solutions L10 | S.M.Electricals L7 | M/s.Raghava Enterprises L3 | KIRON ENGINEERING CORPORATION L9 | M/s DIAMANTO VERTICALS L1 | SRI LAKSHMI ENGINEERING ENTERPRISES L11 | GVR CONSTRUCTIONS L8 | SONI ENGINEERS CONTRACTORS L6 | B.Veerabhadra Rao L4 | ANAND ENTERPRISES AND ENGINEERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance for diesel engine driven generating set by carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed for 750 KVA installed at FWPH including attending to under mentioned jobs to ensure its satisfactory performance:-
Existing DG -01 No Make cummins
Note: Quoted Rates are deemed to be for carrying out A checks as under :-
(a) Checking the fan belt and adjusting tension
(b) Checking the fuel and oil filter
(c) Checking the air filter including cleaning and refixing
(d) Checking of FIP oil level
(e) Tightening the base bolts and nuts
(f) Checking the coupling bolts and adjustment checking the self starter and Dynamo | 10 | Each Job (Each check) | 56,000 ₹5,60,000 | 61,000 ₹6,10,000 | 57,000 ₹5,70,000 | 35,000 ₹3,50,000 | 60,000 ₹6,00,000 | 55,000 ₹5,50,000 | 62,000 ₹6,20,000 | 59,000 ₹5,90,000 | 55,000 ₹5,50,000 | 53,000 ₹5,30,000 | 30,000 ₹3,00,000 Lowest |
| 1.01(g) Checking the battery distilled water levels and topping upto the required level. (h) Checking the panels (Manual as well as AMF) attached to the DG set for loose connections, defects if any in the panel Board and replacement of spares all as directed. (i) Checking the anti vibration mounting and adjusting the bolt (j) Checking the radiator and radiator hose and arresting leak if any (k) Checking the engine oil level and topping upto the required level (r) Checking the cleanliness of DG set and cleaning properly in and out of dg set around an area covering 50 mtrs (s) Checking for any leakages after proper inspection and arresting immediately | ||||||||||||||
| 1.02NOTE:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work. (ii) Servicing of DG set alongwith connected Alternator and AMF Panel Board including 'A' check of the Engine shall be carried out once in every month (Except during the month when 'B' check is carried out) as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required in that period except in case of major repairs. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted . (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. | ||||||||||||||
| 2.00 | Comprehensive maintenance of DG set 500 KVA installed at FMU including attending to jobs as mentioned under item No.1 to 1.15 here in before complete all as specified and as directed.
Existing DG -01 No Make: Kirloskar
Note: Quoted Rates are deemed to be for carrying out A checks as detailed above. | 10 | Each Job (Each check) | 50,000 ₹5,00,000 | 55,000 ₹5,50,000 | 50,000 ₹5,00,000 | 30,000 ₹3,00,000 Lowest | 54,000 ₹5,40,000 | 35,000 ₹3,50,000 | 56,000 ₹5,60,000 | 52,000 ₹5,20,000 | 49,000 ₹4,90,000 | 46,000 ₹4,60,000 | 36,000 ₹3,60,000 |
| 3.00 | Comprehensive maintenance of DG set 100 KVA installed at load test bay including attending to jobs as mentioned under item No.1 to 1.15 here in before complete all as specified and as directed.
Existing DG -01 No Make: Kirloskar
Note: Quoted Rates are deemed to be for carrying out A checks as detailed above. | 10 | Each Job (Each check) | 45,000 ₹4,50,000 | 50,000 ₹5,00,000 | 45,000 ₹4,50,000 | 25,000 ₹2,50,000 | 48,000 ₹4,80,000 | 30,000 ₹3,00,000 | 52,000 ₹5,20,000 | 46,000 ₹4,60,000 | 44,000 ₹4,40,000 | 42,000 ₹4,20,000 | 24,000 ₹2,40,000 Lowest |
| 4.00 | Comprehensive maintenance of DG set 20 KVA installed at DAS including attending to jobs as mentioned under item No.1 to 1.15 here in complete all as specified and as directed.
Existing DG -01 No Make: Koel green
Note: Quoted Rates are deemed to be for carrying out A checks as detailed above. | 10 | Each Job (Each check) | 31,000 ₹3,10,000 | 35,000 ₹3,50,000 | 31,500 ₹3,15,000 | 20,000 ₹2,00,000 | 33,000 ₹3,30,000 | 10,000 ₹1,00,000 Lowest | 36,000 ₹3,60,000 | 32,000 ₹3,20,000 | 30,500 ₹3,05,000 | 29,000 ₹2,90,000 | 26,000 ₹2,60,000 |
| 5.00 | Maintanance and servicing of following Diesel Generator sets by carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functiuning all as per manufacturer's instructions and as directed for 750 KVA installed at FWPH.
Existing DG -01 No Make: Cummins
Note: Quoted Rates are deemed to be for carrying out B checks as under.
(a) Change oil
(b) Change oil filter,fuel filter,bypass filter,air filter
(c) Change water seperator | 1 | Each Job (Each check) | 98,000 ₹98,000 | 1,05,000 ₹1,05,000 | 99,500 ₹99,500 | 1,00,000 ₹1,00,000 | 1,02,000 ₹1,02,000 | 75,000 ₹75,000 | 1,10,000 ₹1,10,000 | 1,00,000 ₹1,00,000 | 99,000 ₹99,000 | 97,000 ₹97,000 | 65,000 ₹65,000 Lowest |
| 5.01(d) Radiator cleaning with chemical (e ) Check all electrical terminals (f) Check for turbo charger and service (g) Check for injector pin and service (h) Check for cylinder head and service (i) Check for pt pump and service NOTE:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work. | ||||||||||||||
| 5.02(ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alonwith connected Alternator and AMF Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of Major repairs. (iii) Spare parts , engine oil and radiator coolant oil required during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. | ||||||||||||||
| 5.03(iv) Cost of all consumables, diesel / oil filters etc., required during the maintenance period shall be deemed to be included in the rate quoted for this item. | ||||||||||||||
Tender Value
₹32.2 L
EMD Value
₹64,480
Closing Date
12 Aug 2025, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
COMPREHENSIVE MAINTENANCE AND REPLACEMENT OF UNSV SPARES WITH ALLIED WORKS OF STAND BY DG SETS FOR FRESH WATER PUMP HOUSE AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE I DM VISAKHAPATNAM
2025_MES_721948_1
8304/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Dockyard Visakhapatnam
As per Tender documents
7 documents required · 7 mandatory
₹500
GE (I) DM Visakhapatnam
₹64,480
Yes
21 Jan 2026
22 Jul 2025
14 Aug 2025
22 Jul 2025
12 Aug 2025
5 Aug 2025
Amount
Comprehensive maintenance for diesel engine driven generating set by carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed for 750 KVA installed at FWPH including attending to under mentioned jobs to ensure its satisfactory performance:- Existing DG -01 No Make cummins Note: Quoted Rates are deemed to be for carrying out A checks as under :- (a) Checking the fan belt and adjusting tension (b) Checking the fuel and oil filter (c) Checking the air filter including cleaning and refixing (d) Checking of FIP oil level (e) Tightening the base bolts and nuts (f) Checking the coupling bolts and adjustment checking the self starter and Dynamo
(g) Checking the battery distilled water levels and topping upto the required level. (h) Checking the panels (Manual as well as AMF) attached to the DG set for loose connections, defects if any in the panel Board and replacement of spares all as directed. (i) Checking the anti vibration mounting and adjusting the bolt (j) Checking the radiator and radiator hose and arresting leak if any (k) Checking the engine oil level and topping upto the required level (r) Checking the cleanliness of DG set and cleaning properly in and out of dg set around an area covering 50 mtrs (s) Checking for any leakages after proper inspection and arresting immediately
NOTE:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work. (ii) Servicing of DG set alongwith connected Alternator and AMF Panel Board including 'A' check of the Engine shall be carried out once in every month (Except during the month when 'B' check is carried out) as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenence / breakdown repairs as and when required in that period except in case of major repairs. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted . (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item.
Comprehensive maintenance of DG set 500 KVA installed at FMU including attending to jobs as mentioned under item No.1 to 1.15 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out A checks as detailed above.
Comprehensive maintenance of DG set 100 KVA installed at load test bay including attending to jobs as mentioned under item No.1 to 1.15 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out A checks as detailed above.
Comprehensive maintenance of DG set 20 KVA installed at DAS including attending to jobs as mentioned under item No.1 to 1.15 here in complete all as specified and as directed. Existing DG -01 No Make: Koel green Note: Quoted Rates are deemed to be for carrying out A checks as detailed above.
Maintanance and servicing of following Diesel Generator sets by carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functiuning all as per manufacturer's instructions and as directed for 750 KVA installed at FWPH. Existing DG -01 No Make: Cummins Note: Quoted Rates are deemed to be for carrying out B checks as under. (a) Change oil (b) Change oil filter,fuel filter,bypass filter,air filter (c) Change water seperator
(d) Radiator cleaning with chemical (e ) Check all electrical terminals (f) Check for turbo charger and service (g) Check for injector pin and service (h) Check for cylinder head and service (i) Check for pt pump and service NOTE:- (i) Control switches , MCCB's, contactors, multi display meters , Engine control unit shall be out of scope of the item of work and the rate quoted shall be exlusive for servicing/ maintenance of the above item of work.
(ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set alonwith connected Alternator and AMF Panel Board including items covered in 'A' check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of 30 days from the date of service and shall also attend all the maintenance / breakdown repairs as and when required in that period except in case of Major repairs. (iii) Spare parts , engine oil and radiator coolant oil required during the maintenance period shall be measured and paid seperatly at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item.
(iv) Cost of all consumables, diesel / oil filters etc., required during the maintenance period shall be deemed to be included in the rate quoted for this item.
Comprehensive maintenance of 500 KVA installed at FMU including attending to jobs as mentioned under item No4 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of 100 KVA installed at load test bay including attending to jobs as mentioned under item No4 here in before complete all as specified and as directed. Existing DG -01 No Make: Kirloskar Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Comprehensive maintenance of of DG set 20 KVA installed at DAS including attending to jobs as mentioned under item No.4 here in before complete all as specified and as directed. Existing DG -01 No Make: Koel green Note: Quoted Rates are deemed to be for carrying out B checks as detailed above.
Checking the tappet clearance and adjustment of valve including replacement of tappet gasket for following DG Sets :-
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply only fuel filter pre and secondary including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply only lube oil filter including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply only air filter element including rubber gasket for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set )
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply only fan belt of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply only Radiator hose with clip of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply only rubber coupling of existing size for following DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Supply and toping up the following items for the DG sets (Cost of replacement deemed to be included in the maintenance part of the DG set)
Engine oil 20 W 40
Distilled water
Battery acid
Coolant
Benzo bolt with washer
Jubilee clamp for fuel pipe
Draining the engine oil from sump removing the sump cover cleaning the sludge and refixing the same including replacement sump gasket and filling oil for the following Gen sets as per manufactures instructions
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Draining out the diesel tank, cleaning / washing out the sludge and re-filling with diesel for following DG set:-
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Taking down radiator, servicing, cleaning of with suitable reagent, washing thoroughly,arresting leakage if any by welding / brazing and refixing the same (Necessary coolant and distilled water required will be measured and paid seperately under Sch item herein before).
DG Set of capacity upto 100 KVA
DG Set of capacity 500 KVA
DG Set of capacity 750 KVA
Replacement of AVR Suitable for 20 KVA Alternators
Replacement of AVR Suitable for 500 KVA Alternators
Replacement of AVR Suitable for 750 KVA Alternators
Contactor 4 P ole upto 630 A
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 100 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed
Removing and replacing the old unserviceable lead acid battery of size 12 Volt , 180 AH of reputed make including charging and shifting & depositing old battery to MES all as specified as directed
M & L for PCC (1:3:6) type C2 (using 40mm graded crusehd stone aggregate ) as in foundation/Copping of pole including necessary form work complete all as specified and directed.
Labour only for attending electrical breakdowns checking the serviceability, testing, replacement of minor spare parts in starters,panels,pumps, making the unit completely functional complete all as specified and directed by Engineer-in-change for the following sizes:- Note 1:- The quoted rate is deemed to be include (i) necessary T&P to attend the breakdown. (ii) Necessary labour/trade men for attending emmergency break down . (iii) labour element and spares required for making the unit completely functional such as control wiring,terminal bolts copper cables,lugs etc. (iv) PCC work wherever required
M&L Earthing complete with copper plate 60cm×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3mm copper strip complete all as specified and directed.
ANAND ENTERPRISES AND ENGINEERS (BID ID -3391541)
M/s.Raghava Enterprises (BID ID -3391162)
B.Veerabhadra Rao (BID ID -3390423)
SREE GAYATRI INFRA (BID ID -3389481)
SONI ENGINEERS CONTRACTORS (BID ID -3391312)
S.M.Electricals (BID ID -3390686)
GVR CONSTRUCTIONS (BID ID -3391406)
KIRON ENGINEERING CORPORATION (BID ID -3391253)
M/s Jai Ganesh Engineering Solutions (BID ID -3390684)
SRI LAKSHMI ENGINEERING ENTERPRISES (BID ID -3390942)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .