EE, South 24 Pgs. Elect. Divn.
57/2 Diamond Harbour Road Kolkata - 700 023
EI works of various doctors rooms at all floors of old hospital building for ensuing Safety and Security of all categories of staffs and implementation of RATTIRER SATHI at Diamond Harbour Govt. Medical College and Hospital under the dist. of S24Pgs.
2024_WBPWD_751979_1
WBPWD/EE/S24PED/eNIT68R/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Diamond Harbour
Please refer Tender documents.
4 documents required · 4 mandatory
₹23,940
30 May 2025
16 Sept 2024
26 Sept 2024
16 Sept 2024
24 Sept 2024
16 Sept 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. a) Avg Run 10 Mtr [for ex-fan]
b) Avg Run 8 Mtr [for call bell & Glow signage]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. a) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [for AC]
b) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. a) 2.5sqmm
b) 4 sqmm
Supply & Delivery follwing different size of XLPE/PVC Ar Al cable, as per direction of EIC. [Make : Havells / Gloster/Polycab/Finolex/RR Kable] a) 4 core 35 sq. mm.
b) 4 core 95 sq. mm.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a) 4 Core 35 Sq. mm
b) 4 Core 95 Sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc. a) 4 Core 35 Sq. mm
b) 4 Core 95 Sq. mm
Laying of cable from 4/3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) wire, making hole etc. as necy., mending good damages and painting
Supplying and fixing 415V, 160A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make: L&T/ Havells / Siemens]
Supplying and fixing 415V, 160A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Make: L&T/ Havells / Siemens]
Supplying and fixing 4 Way double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make:Legrand/ Siemens/L&T/ABB]
Supplying and fixing 240/415 V 63A FP MCB Isolator on din rail of existing DBs and necessary connection. [Make:Legrand/ Siemens/L&T/ABB]
Supplying and fixing 240/415 V 6-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. [Make:Legrand/ Siemens/L&T/ABB]
SUB-HEAD 2--S&F OF FAN & EXHAUST FAN.
Supply & Delivery of 230V 300mm (12") 1420RPM 80W Exhaust fan with all accessories as directed by EIC. [Make: EPC Heavy Duty, Usha, CG, Bajaj or equiv Make]
b) 230 mm (9") 40W 1370 RPM Exhaust fan
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: a) For 30Cm Exhaust Fan (12")
b) For 23Cm Exhaust Fan (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)(6 mm dia x 62 mm long): a) For 30Cm Exhaust Fan (12")
b) For 23Cm Exhaust Fan (9")
S&F sequence multifunction timer for exhaust fan incl. S&F 2M MCB Enclosure with necy connections by Cu wire with the socket , fixed on wall & necy screw etc. as per direction of EIC. (1CMDTO multifunction timer 0.1sec-100Hrs. make-L&T)
Supply & delivery of 1200 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18" down rod(14SWG), Fork(10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc.with safety wire & PS2 type capacitor, as directed by EIC. [Make-Orient / Crompton/ Usha (Safety Wire & S3/P2 Capacitor)]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
S & F 4-blades, 450mm full metal AC wall bracket fan (Orient: Tornado / Crompton / EPC) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length as per direction of EIC.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
SUB-HEAD 3-- STARTERS, SOCKETS & TIMERS
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
S&F of 250V double door AC Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCBIsolator, 2 no. 16A SPMCB ('C' curve 10KA), 1no. Programmable Digital time switch-24 hrs with minimum switching of 15 minutes, and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC. [Make-ABB/L&T/Crabtree]
SUB-HEAD 4--SITC OF AIR CONDITIONER.
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Minimum ISEER - 3.8, BEE level - 3-Star (min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per IS) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable 25plug top (Anchor/North West/Legrand/Havells) [Make: O.General/Mitsubishi Electric/Zamils]
i) Cooling capacity not less than 7000 Watt
ii) Cooling capacity not less than 5200 Watt
iii) Cooling capacity not less than 3800 Watt
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc. as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc. as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe(as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm ,3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast)
SUB-HEAD 5--MISCELLANEOUS
Supplying, fitting and fixing boiling water proof ply conforming to IS: 710-1977 bonded with phenol formaldehyde synthetic resin conforming to IS: 848-1974 of approved make and brand fitted and fixed as per design as per approval and direction of Engineer-in-Charge. 19 mm to install indoor of A.C machine
Dismantling, servicing & refixing Indoor & Outdoor Unit of split type AC machines part by part as per direction of EIC in new place of the following sizes: 1.5 / 2.0 TR
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run [Arrangement of Scafholding for fixing Outdoor Unit of AC Machine at second / third floor to roof level.]
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
JANA ELECTRICALS (BID ID -5596556)
M/S PRITAM ELECTRICALS AND ELECTRONICS (BID ID -5596495)
G.G. PROJECT (BID ID -5596379)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .