Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC MOTHER TERESA ROAD ZOO TINIALI GUWAHATI 781024 | GUWAHATI | KAMRUP METRO | ASSAM | 781024 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.9 L+₹1.1 L (2.83%)Rejected-Finance | L2 | Rejected-Finance Other thanLowest bidder | |
| 3 | L3₹39.8 L+₹1.9 L (5.14%)Rejected-Finance | L3 | Rejected-Finance Other thanLowest bidder | |
| 4 | L4₹42.3 L+₹4.4 L (11.6%)Rejected-Finance JYOTISH ROAD TEZPUR DISTT SONITPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | L4 | Rejected-Finance Other thanLowest bidder | |
| 5 | L5₹43.8 L+₹5.9 L (15.7%)Rejected-Finance | L5 | Rejected-Finance Other thanLowest bidder |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
24 Feb 2020, 6:00 pmClosed
GE AF Tezpur
GE AF Tezpur, Po- Salonibari Distt- Sonitpur Assam-784104
Special repair works in certain OTM Accommodation and living in accomodation in technical area at AF Station under GE AF tezpur
2020_MES_321863_1
8467/E8
Open Tender
Miscellaneous Works
Item Rate
150 days
GE AF Tezpur
Class D cat a(i)
6 documents required · 6 mandatory
₹500
Yes
GE AF Tezpur
₹87,000
Yes
3 Mar 2020
5 Feb 2020
26 Feb 2020
5 Feb 2020
24 Feb 2020
18 Feb 2020
5 Feb 2020 - 12 Feb 2020
Amount
(SCHEDULE 'A' PART-I)Special repair/roof treatment to certain OTM accomodation in technical area (Srl item No 1 to 14 here-in-after) Demolition of cement concrete (unreinforced) as in padding layers of Roofs, floors (other than ground floors) and similar suspended work complete all as specified and as directed
M&L cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in padding on existing roof surfaces & roof kerbs, rounded or chamfered on edges and finished the top surface even and fair complete all as specified and as directed.
M&L rendering 10 mm thick with CM (1:4) on concrete surface including WPC as per manufacture's instruction, roof finished even and smooth without using extra cement over neat cement slurry @ 3Kg/Sqm complete all as specified and as directed (Note:-Liquid WPC will be measured and paid seperately)
Supply only liquid water proofing compound. Note :- (i) 25 Ltr. shall be executed Schedule 'A' Part-II and balance quantity to be executed in this shedule.
M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out, and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 ( by weight) complete all as specified and directed.
M&L providing water proofing treatment with APP based polymeric water proofing membrance 3 mm thick (minimum) weight 4.00 kg/sqm reinforced with polyster non woven fabric shall be laid over one coat of water based bituminous emulsion primer on the existing surface @ 0.40 Kg/Sqm duly thermofused by flame torch complete all as specified and directed. Note:- (i) The overlaps shall be of minimum 75 mm on longitudinal direction and 100mm on transverse direction (ii) Rate includes for safely removal of earthing strips running on roof slabs or any other fittings/fixtures and refixing the same in it's original postion over PCC Blocks 15cmx15cmx15cm after laying APP membrane all as specified and directed by Engr-in-Charge. PCC blocks will be measured and paid seperately
M&L bitumastic gola, with 85/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and as directed.
Disconnecting existing tanks exc 250 Ltrs not exc 500 Ltrs setting aside (for lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and refixing in position after cleaning complete all as specified and directed. Note : Temporary connection to water tanks should be provided during the work to maintain the continuity of water supply and after completion of roof treatment water tanks to be placed in their original position and connections refixed properly
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in platforms, staging for water tanks etc including finishing the surface even and smooth without using extra cement including necessary formwork complete all as specified and as directed.
S&F 1000 Litres capacity rotational moulded three layred polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part – I including necessary tank nipple, complete all as directed.
Taking down 20 mm bore steel tubing and connection including cleaning for refixing or removal from site. Note:- (i) 13 Rm shall be executed Schedule 'A' Part-II and balance quantity to be executed in this shedule.
S&F 20 mm bore galvanised tubing medium grade with all fittings and fixed to walls or laid in floors complete all as specified and directed. Note:- (i) 13Rm shall be executed Schedule 'A' Part-II and balance quantity to be executed in this shedule.
Re-fixing of galvanized steel tubing, medium grade, 20mm bore with all fittings and fixed complete to walls and ceiling or laid in floor all as specified and as directed. Note: (a) Old pipes retrived under item No 12 shall be used in the work (b) While fixing of pipe ,new fittings as required shall be provided by the contractor and cost of same is included in the unit rates of this item. (c) The old pipe shall be cleaned prperly before use in the work and cost of cleaning is included in the unit rate of this item.
(SCHEDULE 'A' PART-II )Special repair to certain Living in accomodation (Ph-I) Srl item No 15 to 158 here-in-after Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
Taking down cement plaster on brick walls/ concrete surface, etc. including raking out joints, hacking for key, scrubbing down with water, etccomplete all as specified and directed.
M&L for Brick work with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in CM(1:6) complete all as specified and directed.
M&L for half thick brick work with sub class "B" bricks straight or curved on plan exceeding 6m mean radius with old size bricks available built in cement mortar 1:4 complete all as specified and directed.
M&L 20 mm thick cement plaster in CM (1:4) in two layers (8mm thick with liquid water proofing compound over backing layer of 12 mm thick ) on fair faces of brick work incl finished the top layer even and smooth without using extra cement, complete all as specified and directed. Note:- (Liquid WPC will be used as per manufactureres instruction and it will be measured and paid seperately)
M&L 10 mm thick cement plaster in CM (1:6) on fair faces of brick work incl finished even and smooth without using extra cement, complete all as specified and directed.
M&L GI wire netting of 0.90 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc in walls, ceilings etc. including all laps, cutting and waste fixed with tinned tacks of wire staples and Demolition of reed, lathing, single or double, battens and plaster or chicken wire lathing, complete as specified and directed.
M&L rendering 18 mm thick in two layers (12mm + 6mm) externally on one side of lathing in cement mortar 1:6 and finished the urfaces even and smooth without using extra cement mixed with and including liquid water proofing compound as per manufature's instruction on top layer of 6mm thick complete all as specified and directed.
M&L rendering 12 mm thick on other side of lathing in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement as specified and directed.
M&L for Preparation of undecorated new surfaces of AC ceiling board and applying three coat of white wash on ceiling complete all as specified and directed.
M&L preparation new plastered surfaces of brick work or previously untreated and applying two coats of oil bound distemper over 1 mm thick wall care putty complete all as specified and directed.
M&L for prepration of new or previously untreated plastered surfaces of walls and applying two coat of cement base paint over one coat of cement priming paint complete all as specified and directed.
Demolition of Cement concrete in ground floors and pavings n exc 15 cm thickness below or above ground level) complete all as specified and directed.
M&L Hardcore of gauge n exc 63 mm with brick aggregate, deposited , spread and levelled in layers n exc 15 cm thick , watered and rammed to a true surface complete all as specified and directed.
M&L for 50mm thick cement concrete type C1( 1:3:6) (20 mm graded aggregate) as in plinth protection including finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for RCC (1:2:4) type B1 (using 20 mm graded broken stone aggregate) as in slab supported on walls, beams and column in floors, roof landings, balconies, canopies, deck slabs and in shelves incl demolitionof existing reinforced cement concrete complete all as specified and as directed. (Note : Reinforcement shall be measured and paid seperately under relevant)
M&L for pre-cast reiforced cement concrete (1:2:4) type B1(using 20mm graded broken stone aggregate) as in cover slab, set in cement mortar (1:4) with plain faces including necessary form work and including demolition of existing reinforced cement concrete complete all as specified and as directed. Note: Reinforcement shall be measured and paid separately under relevant item.
M&L TMT bar 10 mm and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.
M&L formwork to soffit of suspended slab such as roof, floor slabs, landing similar work for rough finished surfaces of concrete, flat complete all as specified and as directed.
M&L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 5cm but not exc 10cm wide for rough finished surfaces of concrete, flat complete all as specified and as directed.
Dismantling wall tiling including cement mortar bedding and backing up to surface for laying of new surface and rubbish of the premises. (but not backing), removing serviceable tiles to store and rubbish off the premises.
Demoliton of stone slabs, and tiles of any description or thickness in floors apron etc
M&L for cement concrete (1:2:4) type B1 of 20 mm graded aggragate of 25 mm thick as in floor complete all as specified and as directed.
M&L for Pre polished kota Stone slab 18 - 20 mm thick over 20 mm thick cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
M&L Non Skid ceramic colour tiles of size 400mmx400mmx7 to 8 mm thick(square/ rectagular) , in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for 450x300x7mm thick glazed ceramic colour tiles on vertical surface set in neat cement slurry over cement screed and pointed in white or coloured cement complete all as specified.
S&F Granite (of any type) tiles 18-20 mm thick machine cut, bedded and jointed with grey cement slurry over cement screed and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types as in wash basin top complete all as directed and directed.
M&L Chequered cement concrete tiles 20cmx20cmx25mm thick, set,jointed and pointed in neat cement slurry in floors complete all as directed and directed.
M&L for pre polished kota stone slab 15 - 18 mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick screed bed in cm (1:3) and jointed incl cutting and polishing complete all as directed and directed.
M&L for 20 mm thick screed bed or bedding layer of mortar for laying floor finishes in cm 1:6 complete all as specified.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cm(1:4) for receiving the tiles complete all as specified.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cm(1:3) for receiving the tiles complete all as specified.
M&L for 2nd class hard wood timber scantling, clean sawn as in frame work, fixed with nails including dismantling of frame work timber scantling 40 sqcm and over in section in any position complete all as specified and as directed.
Dismantling of timber scantling under 40 sqcm in section as in fillets, rails, posts, rafters, purlins etc unframed work complete all as directed.
S&F for 2nd class hard wood timber in fillets, square, rectangular or triangular in section, clean sawn, fixed with nails, sectional area exc 3 Sqcm but not exc 6 Sqcm complete all as specified and as directed.
S&F 2nd class HW plain fillets,square,rectangular, triangular in section exc 06 Sqcm but n exc 13 Sqcm wrought finished fixed with nail.
S&F 2nd class HW plain fillets,square,rectangular, triangular in section exc 13 Sqcm but n exc 25 Sqcm wrought finished fixed with nail.
S&F mild steel screw bolts(machine made), with hexagonal or square heads at one end and scewed the other , or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut, diameter of shank 11 to 15 mm length of bolt exc 10 cm but n exc 15 cm long , incl dismantiling of U/S nuts and boltscomplete all as specified and directed.
All as per serial item No.52 here-in-before but dia meter of the shank 16 to 20 mm and length of the bolt 15 cm to 22.5 cm long .
M & L for asbestos cement plain building boards , 4mm thick fixed to timber framework with screws in ceiling flat or slopping and Preparation of new surfaces and applying three coat of white wash on ceiling, including Dismantling of wall and ceiling boards (fibre pulp,insulation etc) or insulation boards/slabs any thickness incl cover fillets complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screwes and including dismantling of corrugated AC sheets Corrugated semi corrugated sheets in roof covering complete all as specified and directed.
S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F 20 mm thick 2nd class hard wood boarding planed one side with butt joints and fixed complete in eaves board and including dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
M&L for preparation of new wooden surfaces over 10cm width or girth and applying two coats synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new wooden surfaces of any description n exc. 10cm girth or width, not otherwise described and applyng two coats synthetic enamel paint over a coat of pink primer complete
M&L for preparing surfaces of wood and wood based materials , new or old , of any description and girth , not otherwise described and treated wit one coat of creosote oil , complete all as specified and as directed.
S&F in repair powder coated aluminium anodised tubular curtain rod 25 mm dia with fixing brackets, stops, rollers etc.complete all as specified and directed.
S&F 15 mm bore GI pipe tubes medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floor and including taking down 15 mm bore GI tubing or up steel tubing and connection complete all as specified and directed.
Cutting chases, pinning in making good to facings brick wall where required and pointing in cement mortar 1:3 to ends or edges of landings steps cills chases for concealed water tubing, exc 10 cm but not exc 20 cm girth complete all as specified and directed.
S&F in repair plastic water closet seat and cover for pedestal pan, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)and fixing with 'S' trap with vent horn complete all as specified.
S&F in repairs 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified.
S&F as in repairs vitreous china squatting pan of orissa pattern long pan size 580 mm x 440mm white front or back inlet and including provision of PCC or lime concrete bedding and 32 mm dia flush pipe etc fixing with 'P' traps with vent horn and removal of debris complete all as specified.
S&F in repair for urinal bowl type of size 465x355x265 mm, white including connections to flushing pipe and outgoing pipes with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2,securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixed in repairs, complete all as specified and directed.
S&F in repairs 32 mm dia X 800 mm waste pipes for sink/wash hand basin including coupling complete all as specified and directed.
S&F in repair Wash Hand Basin, vitreous China white (oval type) of size 550x400 mm, complete all as specified and directed.
S & F in repairs brass chromium plated shower rose 125mm size with or without swivel joint any size including fixing to steel pipe or union complete all as specified and directed.
S&F in repair stop valve/ angular stop cock fancy type, chromium plated, screwed alloy, screed down, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed 15m bore pipe complete all as specified.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified.
S&F in repairs15 mm bore pillar taps cast copper alloy, with capstan heads, chromium plated, complete all as specified and directed.
S&F as in repairs 50 mm bore high density poly-ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified.
S&F in repairs 15 mm bore bib taps of chromium plated alloy with crutch or butterfly handle, screwed down , screwed for iron pipe or for brass ferrule complete all as specified.
S&F in repair 1000 Ltr capacity triple layered rotational moulded polyethyene water storage tanks (Cylindrical vertical with closed tap) twisted and fixed in position all as specified in SSR Part-I, complete all as specified and directed.
S&F in repair for ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed, screwed for iron pipe 20mm bore ( min weight 210 gms), complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) area n.exc 1.5 Sqm each.
Taking down chowkats or frame with shutters (without taking off shutters from the frame) area exc 1.50 sqm but n.exc 4.0 Sqm each.
Taking down shutter of any description not exc. 1.00Sqm and removing to store complete all as directed.
Taking down shutter of any description exc. 1.00 Sqm and not exc 2.00 Sqm and removing to store complete all as directed.
S&F for 2nd class hard wood in plain, solid, straight chowkats and framed, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut or mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, section-8, cluse 8.24 (a) complete all as specified and as directed.
S&F for 30 mm thick 2nd class hard wood glazed and skeleton shutters, for window /ventilators open rebated and prepared to receive glass, gauze etc divided in to squares with plain, chamfered or rounded, fitted with cut or mitred sash bars (any numbers) timber beads for securing glass etc sizes of members of shutters as specified in SSR Part-I, section-8, cluse 8.24 (b) complete all as specified and as directed.
S&F 35 mm thick plain framed, panelled shutter with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F butt hinges 100mm long cold rolled medium weight complete all as specified and as directed.
S&F 150mm long mild steel pressed handles, oval type, stove enameled black complete all as specified and as directed.
S & F Aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 200mm long complete all as specified and directed.
S & F Aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 150 mm long complete all as specified and directed.
S&F 250mm long Aluminium sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
Supply and fix butt hinges 75mm long cold rolled medium weight complete all as specified and as directed.
S & F Aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 100mm long complete all as specified and directed.
S&F in for 150mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
S&F for mild steel works as in hold fast and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for PCC(1:3:6) type C1 (using 20mm graded broken stone aggregate) for fixing hold fast complete all as specified and as directed.
S&F in repair for mild steel frame works such as grills, gratings etc with ends of bars shouldered and/ or reveted, or forged in to spikes, framed guard bars, framed balusters, railing and similar works conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Hacking out old broken glass of any thickness or any size from wooden frame or stone, concrete or brick surround glazed complete all s directed.
S&F for 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed.
S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples or with wooden beading or any other fixing arrangements complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of aperture 1.40mm dia fixed with stainless steel wire staples or with wooden beading or any other fixing arrangements complete all as specified and as directed.
M&Lfor preparation of new steel or iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Taking down shutter and re-fixing in same opening of shutters of any description not exceeding 1 sqm with existing chowkat , frame or wiith new chowkat or frame each complete all as directed.
Taking down shutter and re-fixing in same opening of shutters of any description exceeding 1 sqm and not exceeding 2 sqm with existing chowkat , frame or wiith new chowkat or frameeach complete all as directed.
S&F for PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed.
S&F for factory made PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading incl 110 mm PVC door bend , and jointed together with solvent cement complete all as specified and as directed.
S&F 150 mm mild steel helical pattern springs including roller and roller plate complete all as specified and s directed.
M&L for treating back of chowkats area tarred exc 0.10 Sqm but n exc 0.50 sqm each, with tar or coal tar black paint, complete all as specified and directed.
M&L treating small articles such as hold fast etc area n exc 0.10 sqm but n exc 0.50 sqm each, with tar or coal tar black paint, complete all as specified and directed.
Resecuring or easing and adjusting without taking down the shutter of size n exc.1 Sqm complete all as specified and directed.
S&F for banks ,straps , support or stays rain water , ventilating pipes , including bolts , if required ; hooks (stay), heavy , for large gates hook and pintel hinges ; large hasps and staples chains hand made sliding bolts clamps hold fats will ties hooks for hanging fans and for securing wire for mosquito net ; two way and three way straps plate washres and similar small articles conforming to Fe 410 or Fe 310 -0, complete all as specified and directed.
M&L for plates ( plain or chequered ) channels , square cut or notched) (ordinary and counter sunk) forming holes , with out any attachment
S&F Plain mild steel wire , galvanised class 3 , of 4 mm dia of wire as in mosquito net tying wire ,and in fencing including straining and fixing to wood, concrete or steel posts and or to straining bolts , including securing with and provn of galvanised iron tying wire complete all as specified and as directed.
M&L for excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out complete all as specified and directed.
Returing , filling in , including spreading , levelling , watering and well ramming in layers n exc 25 cm above the starting point for soft/ loose soil, complete all as specified and directed.
Removing excavated soil to a distance n exc 50 m and depositing where directed at a level n exc 15 m aboe the starting point
M&L salt glazed stoneware drain pipe 150 mm internal dia grade 'A' laid in trenches and jointed in cement mortar and tested and including PCC type C2 (1:3:6) for concrete bed, packing under, and haunching against the sides of pipes after they are laid and tested including demolition of and breaking up drain pipes 150 mm internal dia (Salt glazed stone ware ) set in cement mortar complete all as specified and directed.
S& F in repair for PVC (SWR) pipes of 110 mm bore socketed complete all as specified and directed.
S& F in repair for PVC (SWR) bends of 110 mm radius, complete all as specified and directed.
S& F in repair for PVC (SWR) junction single 'T' equal or unequal of 110 mm radius, complete all as specified and directed.
S&F in repair for PVC (SWR) vent cowl, complete all as specified and directed.
S&F in repair for grating doom 100 mm dia of PTMT (Minimum weight 25 gms), complete all as specified and directed.
M & L for cast iron nahani trap for 100mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4), complete all as specified and directed.
M&L Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate in surface channels of drains and benching including finishing the top of benching even and smooth using extra cement incl demolition of existing cement concrete .(forming fair finished channel shall be measured & paid for separately)
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered /stopped ends etc.
Cutting into existing man holes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm dia
M&L for preparation of old kota stone surface with mirror polish all as specified and as directed.
Materials and labour point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core, drawn through and including PVC casing and capping not less than 20mm size complete with all fittings and accessories, fixed to walls/ ceiling, including sunk cast type pressed steel terminal boxes 1.25mm thick with 2.2 mm plastic laminated sheet (Hylem) top cover for mounting switches/ regulator etc including 1.5 Sqmm PVC insulated unsheathed multistranded (green colour) copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one light point/ one fan point controlled by one one way switch including taking down carefully copper/ aluminium point wiring (light/fan/bell) complete inclusive of all fittings such as switches, ceiling roses, pendants, regulators, sockets, fittings etc. removing materials from site and making good disturbed surfaces of floors/walls/ceiling etccomplete all as specified and as directed.
All as per serial item No.130 here-in-before but for one 3 pin 5 amps switch combination on independent board.
All as per serial item No. 130 here-in-before but for one 3 pin 5 amps switch socket out let on same board.
All as per serial item No.130 here-in-before but wiring with 2.5 Sqmm including 2.5 Sqmm PVC insulated unsheathed multistranded FRLS copper conductor cable 1100 volts grade, single core earth continuity conductor connected to common earth dolly for 2 in 1, 3 pin 5 and 15 Amp switch socket out let on independent board.
S&F switch piano, flush button single pole one way 5 Amp complete all as specified and as directed
S&F socket out let 3 pin 5 Amps, flush type complete all as specified and as directed
S&F switch socket combination 2 in 1, 3 pin 5 Amp flush type universal complete all as specified and as directed.
S&Fswitch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal complete all as specified and as directed.
S&Fceiling rose, surface bakelite, 65mm x50mm three terminals complete all as specified and as directed.
S&F fan regulator electronic type rotary step, 120/280 volts complete all as specified and as directed
S&F LED batten with tube 1 x 20 Watt, 6500K, System Luminous Efficacy more than 100 lm/W with high quality aluminium extruded with decorative end caps with three year warranty including taking down old light fittings any discription capacity size including disconnection of all electric connections and removing unsv materials off the site of work and making good disturbed surfaces of walls, ceilings etc complete all as specified and directed.
S&F lamp holder, insulated body, angular type with back plate for batten fitting including LED lamp 9 Watt complete all as specified and as directed.
S&F sheet metal enclosures MCB DB 4 way SPN, double door, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies including disconnecting from electric circuit and taking out existing unserviceable MCB DB SPN etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etcall as specified and directed
S&F sheet metal enclosures MCB DB 8 way SPN, double door, with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies including disconnecting from electric circuit and taking out existing unserviceable MCB DB SPN etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc all as specified and directed.
S&F sheet metal enclosures MCB DB 4 way TPN, Vertical type , with 200 Amp rated bus bar including earth & neutral link, complete fixing acessoreies including Disconnecting from electric circuit and taking out existing unserviceable MCB DB TPN etc any number of ways including MCB etc removing materials from site and making good disturbed surfaces of floors/ walls/ ceiling etc all as specified and directed
S&F Miniature circuit breaker (MCBs) Single Pole, 240 Volts, 10KA, 6 to 32 Amps, 'C' curve complete all as specified and directed.
S&F Miniature circuit breaker (MCBs) Single Pole, 240 Volts, 10KA, 40 Amps, 'C' curve complete all as specified and directed.
S&F MCB SPN 6 to 32 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed.
S&F MCB SPN 40 Amps 10KA ‘C’ series 240 volts complete all as specified and as directed.
S&F Miniature circuit breaker (MCBs) Triple Pole and Neutral, 415 Volts, 63KA, breaking capacity 'C' curve complete all as specified and directed.
S&F backlite blanking plate in lieu of MCB's complete all as specified and directed.
M&L for two single core PVC insulated unsheathed cable 6.0 sqmm with multistranded copper conductor FRLS cable,1100 volts grade drawn and including Rigid Steel Conduit 20 mm bore and continuous earth wire of single core PVC insulated, unsheathed cable 6.0 sqmm with multistranded copper conductor 1100 volts grade for sub main wiring including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note : Two run of wiring cable, one run of earth wire and one run of rigid steel conduit shall be measured as one unit.
M&L two single core PVC insulated unsheathed cable 4.0 sqmm with multistranded copper conductor FRLS cable,1100 volts grade drawn through and including Rigid Steel Conduit 20 mm bore with accessories and continuous earth wire of single core PVC insulated, unsheathed cable 4 sqmm with multistranded copper conductor 1100 volts grade for sub main wiring including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note : Two run of wiring cable, one run of earth wire and one run of rigid steel conduit shall be measured as one unit.
M&L sub main wiring with twosingle core PVC insulated unsheathed cable 6.00 Sqmm (Nominal area) with multistranded FRLS copper conductor cable, 1100 volts grade drawn through and including PVC casing & capping of size not less than 25mm with accessories and earth continuity conductor of single core PVC insulated, unsheathed cable 6.0 Sqmm (Nominal area) with multistranded copper conductor, 1100 volts grade including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and directed. Note:- (i) Two run of wiring cable, one run of earth wire and one run of PVC casing & capping shall be measured as one unit.
M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm and 3.5 core including taking down old unserviceable sub main wiring of any size and making good disturbed surfaces complete all as specified and as directed
S&F Exhaust fan 300mm sweep 900 RPM , heavy duty , AC single phase 230/240 volts metal body with louver shutters of suitable size covers complete hole all as directed. Note:-Contractor has to furnished a replacement/rectification warranty against any failure or loss of performance for a period of one year Exhaust Fans from the date of completion of contract.
S&Fceiling fan 1200 mm sweep with down rod ,canopy ,fan blades and accessories, BEE 5 star rating with ISI marked and connecting up including provision of PVC insulated sheathed round flexible wire with multistranded copper condictor of size 1.50 Sqmm 3 core 1100 volts aomplete all as directed. Note:-Contractor has to furnished a replacement/rectification warranty against any failure or loss of performance for a period of one year Ceiling Fans from the date of completion of contract.
M & L for earthing complete with galvanized steel earth plate electrode 600mmx600mmx6mm thick buried directly in gournd (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized 4 mm dia earth wire as earthing lead upto 7.5 mtrs from testing point fixed by means of steel bolts, nuts, check nuts and washer, of galvanized earth wire protected by 25mm bore medium grade galvanised iron pipe and other end connected to earthing test point including funnel with watering pipe of 20mm bore light grade galvanised iron, wire mesh, charcoal or coke and common salt in alternate layer of 15cm (Compacted thickness) all around earth electrode with concrete earth pit in PCC (1:3:6) type C-1 50mm thick precast RCC M-20 nominal mix cover slab of size 450mm x 450mm reinforced with 8mm dia TMT bar 10 cm C/C and suitable handle of 10mm dia round bar including necessary execavation, earth work in soft / loose soil and deposited soil to a distance n.exc 50 M and necessary testing complete all as shown in electrical plate No. 3 of MES shedule of SSR Part-I complete all as specified and as directed.
S&F GI wire dia 4 mm size complete all as specified and as directed.
M/S A K MITRA
KAILSON
SHRI D. C. BISWAS
Shri A. K. Goswami
M/S Kangkans
M/S N G CHOWDHURY
M/S Mandeep Singh
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .