Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-Finance AT GROUND FLOOR MAIN BAZAAR MEHRE TEHSIL BARSAR DISTT HAMIRPUR H P PIN CODE 174305 | HAMIRPUR | HIMACHAL PRADESH | 174305 | L1 | Accepted-Finance Lowest Amount | |
| 2 | L2₹27.0 L+₹5.7 L (27.0%)Rejected-Finance | L2 | Rejected-Finance Highest Amount | |
| 3 | L3₹36.8 L+₹15.5 L (73.0%)Rejected-Finance VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L3 | Rejected-Finance Highest Amount |
Tender Value
₹23.5 L
EMD Value
₹42,810
Closing Date
19 Apr 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Er. Rahul Dhiman EE
JSV Division Nagrota Bagwan
Providing LWSS to Harizan Basti Palra GP Khawa in Tehsil Baroh
2023_HPIPH_72183_1
NGB-KNG01-773
Open Tender
Civil Works
Item Rate
180 days
Nagrota Bagwan
Please refer Tender documents.
10 documents required · 10 mandatory
₹400
₹42,810
15 Jan 2026
12 Apr 2023
19 Apr 2023
12 Apr 2023
19 Apr 2023
12 Apr 2023
Amount
Supply of submersible pumping set of (KSB / Kalama/ Kirloskar/ Johnston/ Cromption/ BS) make conforming to IS; 5659-1970 latest suitable for lifting raw water (latest with uptodate ammendments) fitted with bronze impellers/ suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to IS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head : 24.79 Mtrs
Discharge required from each pump. : 7.46 LPS
No. of pump required : 2.00 No. Set (one act stand by)
Location of the site of installation of machinery. :
The Altitude of installation. The altitude of place is750 mtrs above MSL
Type of current. AC Three phase supply with frequency of 75 cycles/second
Rate Voltage : 415+ 10%
Type of water and its source : Raw water from S/Well
Charactristics of water. :
a)Ambient Temperature dig.c : 20 dig. C
b)Turbidity NTU :
c)Hardness260Mg/Ltrs(as CaCO3) : -
e)total solid Mg /Ltrs : -
f)Other : -
Depth of Sump well : 6.32 mtrs
LWL in Sump well : 735.00 mtrs.
Center line level of Pump : 736.00 mtrs
Discharge level of highest point : 755.00 mtrs
Static head in Mrs : 23.00 mtrs.
Length of R/Main : 60 mtrs. (medium class)
Dia of Rising main : 100 MM
No of working hours per day : 8 Hours
Limit of pump operation. : (-) 15 % (+) 10% of total head
R.P.M. of pumping set. :2900 RPM ( or to be specified by the tenderer)
Test run. : 8 Hours continueously for 7 days
Dia of Sump well : 3.60 mtrs
Supply , Installation, Testing and Commissioning of Star Delta Starter panel for Submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pump of rating 5 HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for 5 HP starter complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Voltage Protection device to protect panel from over voltage and under voltage complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Electric/MAS/Elle complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Main incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc. complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Control Transformer to provide a stable control volatge to safegaurd the control circuit of all the components from the voltage surges and spikes complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Supply, Installation, Testing and Commissioning of Timer based automation for Submersible pump complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Installation of Global System for Mobile communication based module to give ON and Off command to enable switch On and switch Off to starter complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Installation of Mobile Application (Android/IOS) to give On and Off command to starter through a mobile app and also it should give message about the ON and OFF status of starter complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
2nd Stage-----------------------------------------------------------------------------------------------------Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below:-
Total Head : 302.58 Mtrs.
Discharge required from each pump. : 7.37 LPS
No. of pump required : 2.00 Set (One act as stand by)
Location of the site of installation of machinery :
The altitude of installation. : 750 MSL.
Type of current. : AC three phase supply with freqduency of 75cycle per second.
Rate Voltage : 415V + 10%
Type of water and its source : Clear water.
Shaft level : 745.50
Level of discharge point : 1000.00
Static Head : 257.50
Charactristics of water. :
a)Ambient Temperature dig.c : 21 dig. C
b)Turbidity NTU :
c)Hardness260Mg/Ltrs(as CaCO3) : -
e)Total solid Mg /Ltrs : -
f)Other : -
Depth of well assembly : -
No. of working hours per day : 16.00Hours.
Length of Rising main : 2270 Rmts.
Dia of Rising main : 100 mm (Medium & Heavy class)
Limit of pump operation. : In the completem Range of (-)75% .
R.P.M. of pumping set. : 2900 RPM (or to be specified by the tenderer).
Test run. : 8 Hours contineously for 7 days.
Supply , Installation, Testing and Commissioning of Star Delta Starter panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. pumps (1 working & 1 stand by) each of the rating 60 HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, under voltage, dry run protection and phase loss with LED ON/OFF & TRIP indicators. Make: Aarmation Electric Private Limited/MAS/ELLES/Adlec complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Star, Delta and Mains Power Contactors of required ratings as per type-2 co-ordination for 60HP starter complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Voltage Protection device to protect panel from over voltage and under voltage complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make Aarmation Electric/MAS/Elle complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads an
Main incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and li
Individual Starter incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc. complete in all respect as per the direction and to be entire of Engineer-in-Charge within a
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Control Transformer to provide a stable control volatge to safegaurd the control circuit of all the components from the voltage surges and spikes complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lift
Mini PLC (Programmable logic controller) with appropriate digital and analog inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable Frequency Starter Panel Make Aarmation Electric/Bechoff Automation/Rockwell Automation/ complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Electronic relay card 8 channel complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
SMPS 4.5 Amps to energise PLC system complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
HMI (Human Machine Interface) 7" display for Monitoring and Controlling of Centrifugal pumps Make: Aarmation Electric/Bechoff Automation/Roackwell complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Control MCB for Automation System complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Level Sensor to indicate the water level of tank remotely complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Shielded Data Cable for Communication of Level Sensor with PLC complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Installation, Commissioning and Software Development complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Excavation in foundation and trenches (for pipes and pits) up to all depths and in all clasification of earth work such as pick Work, jumper work, chiselling or Wedging out of soft and hard rock where the blasting work is prohibited saturated soil including pumping or bailing out water in all lifts including trimming and dressng of sides, levelling of beds to correct grade including shoring strutting planking timbering and dewatering where ever required. Stacking usable and unusable matrial/soil separetaly and after laying, jointing and testing of pipes (for pipes, pipe duct, chambers, x-signs etc.) returning the usable soil in 15 cm layers by ramming and wetering and then desposing of all surlus excavated soil/un usable material as directed wirhin all leads/lifts includng restoration of unmetalled surfaces to its original conditionn and includng cost of divresion for traffic, night signal boards, fixing custion boards, crossing over tranches for access to houses, fencing etc. complete in all respect as per the direction and to be entire of Engineer-in-Charge within all leads and lifts.
Laying, jointing & testing of bevelled ended GI pipe with 94% circumfrential butt welded joints by electrical arc welding and 6% flange joint (welding thickness shall be equal to pipe wall thickness) and testing of GI pipe of Jindal/Surya Roshni/Tata/AST make of following dia meters conforming to IS 1239-1990 (Part-III), having wall thickness as specified below capable of withstanding required test pressure, including manufacturing and febrication of reducers/ tapers, all short pieces, bends etc. as per site requirement made from parent tubes. The laying of pipe shall also include welding of flanged joints wherever required duly welded in three layers (two inner & one outer) and all operations such as cutting, welding, jointing, fefurication of bends, tees, making bevelled pipe ends suitable for butt welding , lowering & laying in excavated trenches to ensure required level complete in all respects to the best satisfaction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately). The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The damaged portion of the pipes ( If damaged during laying & jointing operation of pipe) and all other specials made from the parent tube shall be provided with anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing of pipes, D.P. test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (For the fire fighting providing and laying of pipes also included G.I. Nipple, Tee, Reducer, Bends, Union, Gass Weling etc.).
100mm dia (M-class), Stage 1st RD 0 to 60 = 60Rmts. (Flange Table-5) (Wall thickness = 4.50mm)
100mm dia (H-class), Stage 2nd RD 0 to 1100 = 1100 Rmts. (Flange Table-28) (Wall thickness = 5.40mm)
100mm dia (H-class), Stage 2nd RD 1100 to 1900 = 800 Rmts. ((Flange Table-17) (Wall thickness = 5.40mm)
100mm dia (M-class), Stage 2nd RD 1900 to 2270 = 370 Rmts. ((Flange Table- 5) (Wall thickness = 4.50mm)
Providing MS flanges (In pairs) for the joints of GI pipes mentioned as below and same shall conform to BIS 6392-1971 ( latest with up to date amendments) including the cost of nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets conforming to relevant BIS standards and it shall also include carriage of materials within all leads and lifts complete in all respect to the best satisfaction and direction of Engineer in charge.
100mm dia (M-class), Stage 1st RD 0 to 60 = 60Rmts. (Flange Table-5) (Wall thickness = 4.50mm)
100mm dia (H-class), Stage 2nd RD 0 to 1100 = 1100 Rmts. (Flange Table-28) (Wall thickness = 5.40mm)
100mm dia (H-class), Stage 2nd RD 1100 to 1900 = 800 Rmts. ((Flange Table-17) (Wall thickness = 5.40mm)
100mm dia (M-class), Stage 2nd RD 1900 to 2270 = 370 Rmts. ((Flange Table- 5) (Wall thickness = 4.50mm)
Providing and fixing of Cast Steel (NRV) Non-Return Reflux valve 100 mm dia (swing check type) of Kirloskar/LeaderKilburn/Kartar make confirming to BIS-1868-(API 600) of following class & dia complete in all respect including all leads and lift as per the direction and to the entire satisfaction of Engineer-in-Charge.
KULBINDER SINGH GOVT CONTRACTOR
SANJAY SAINI
stage.html
html • 0.05 MB
technical_108618.pdf
techsummary_108618.pdf
finance_108618.pdf
BOQ Comparative Chart
xlsx
finsummary_108618.pdf
cancelled_1.pdf
pdf • 0.28 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_108618.xls
BOQ • 0.32 MB
Form6and8.pdf
Tender Documents • 1.29 MB
Terms.pdf
Tender Documents • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .