Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 2 | Admitted-Finance 2ND FLOOR SC ROAD SANTA PLAZA TEZPUR DISTT SONITPUR ASSAM PIN 784001 | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 3 | Admitted-Finance MAHABHAIRAB PO TEZPUR DISTT SONITPUR ASSAM PIN 784 001 | SONITPUR | ASSAM | 784001 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
21 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) Tezpur
GE (N) Tezpur C/o 99 APO
REPAIR/REPLACEMENT AND MAINTENANCE OF LT OVERHEAD LINES AND CONNECTED ITEMS IN ZONE 7, 8 AND 9 AT NAA UNDER GE (N) TEZPUR
2021_MES_491564_1
GE(N)/TEZ/2021-22/8560
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (N) Tezpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE (N) Tezpur
₹80,000
Yes
31 Dec 2021
30 Nov 2021
23 Dec 2021
30 Nov 2021
21 Dec 2021
14 Dec 2021
60 days
Amount
Note 1: (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Taking down down/dismantling old/rusted/broken steel poles/struts,removing from site and making good disturbed surface complete all as specified and directed.
Taking down down/dismantling old/rusted/deshaped cross arms/MS channel or angle for reuse complete all as specified and directed.
Dismantling insulators any type, any size including setting aside serviceable and removal of rubbish material complete all as specified and directed.
Dismantling of ACSR conductors of any description,stacking serviceable conductor aside for reuse and removing unsv/broken conductor complete all as specified and directed.
Taking down down/dismantling old/broken stay assembly complete including demolition of concrete, etc. and excavation complete all as specified and directed.
Dismantling /taking down old rusted /broken GI earth wire from feeder or distributor span complete all as specified and directed.
M&L Mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Fixing only mild steel cross arms, bracings, supports, clamps, and back plates obtained vide item N0- 2 here-in-bebore, including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including preparation of surfaces and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for aluminium conductor,steel reinforced (ACSR) of any size, stringing properly on insulators on pole and binding with aluminium tape / binding with conductors, jumpers etc including dismantling and taking down old unserviceable ACSR conductor complete all as specified and directed.
M&L for Supplying, transporting, erecting in truely vertical steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts,nuts and screws as specified, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed, painting of exposed surface of steel tubular poles with two coats of Aluminium paint over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Restringing of LT overhead lines comprising ACSR conductors of any size from 04 conductors to 07 conductors after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
Restringing of LT overhead lines comprising ACSR conductors of any size From 08 conductors to 10 conductors after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag complete all as specified and directed.
S&F (in repairs) guarding Cradles, hexagonal/ rectangular,fabricated with galvanised steel wire 4 mm dia on LT pole including binding with 14SWG MS wire complete all as specified and directed.
S&F (in repair) Insulator Pin type, povrcelain, vitreous, white, brown or green, insulator including one galvanised mild steel spindle, two galvanised iron washres and one glavanised iron nut, 100 mm height, 65 mm die. For 1100 volts grade complete all as specified and directed.
S&L in repair of shackle type Insulator porcelain vitreous white/ brown or green, 75 mm high and 90mm dia suitable for working pressure of 1100 Volt including Galvanized iron straps of size (31x3) mm ,nut, bolt of dia 12 mm and washers of suitable size, complete all as specified and directed.
S&F (in repairs) Stay Assembly comprising of 7/2.24mm galvanised MS stranded wire of rquired length fixed to pole with and including flat iron clamps fabricated out of 50x6mm flat iron and nuts,bolts & washers of suitable size, 40cms long 14mm dia galvanised MS stay bow, 215cms long 20mm dia stay rod with threaded end including bolts & washers, MS stay plate galvanised 230x230x6mm, two thimbles,loop type insulator of size 65x90mm with clearance dia of hole 20mm including necessary excavation, earth work and PCC 1:4:8 type D2 using 40mm stone aggregate complete all as specified and directed.
M&L for connecting service cable 2 core 10 sqmm 1100 volts grade heavy duty flat or circular PVC insulated aluminum multistranded conductor served with inner sheathing of PVC and overall PVC sheathed on service connection suspended by insulated hangers not more than 1 mtr apart including 4mm dia suspended GI wire complete all as specified and directed.
Taking down U/s service cable any size from wall/poles complete after disconnection all as specified and directed
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth in soft / loose soil and getting out for removing / laying of pipe /Cables etc complete all as specified.
Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified and directed.
Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified and directed.
M&L for river sand, washed and screened dry for cushioning to under ground cable in tenches below and around under ground cable including spreading and levelling complete as specified and directed.
M&L laying well burnt old size bricks, sub calss "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cablefor protection all complete all as specified and directed.
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified and directed.
Taking down old u/s LT UG Cables of any size from trenches/poles/walls complete after disconnection all as specified and directed
M&L for Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of following sizes, complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under relevant items).
10 Sq mm cross sectional area, 2 core.
16 Sq mm cross sectional area, 4 core.
25 Sq mm cross sectional area, 4 core.
35 Sq mm cross sectional area, 3.5 core.
50 Sq mm cross sectional area, 3½ core.
70 Sq mm cross sectional area, 3½ core.
95 Sq mm cross sectional area, 3½ core.
120 Sq mm cross sectional area, 3½ core.
150 Sq mm cross sectional area, 3½ core.
Supply and fixing of GI strip 32 x 6 mm fixed in ducts / on wall / in trenches / floors etc for earthing complete fixed to equipment / test point / earth electrode complete all as specified and directed
Trimming of tree branches touching to LT / HT OH lines not exceeding 30 cm girth, shrub, vegetation, bush and saplings at least upto 5.0 M from outer edge of ACSR including cleaning of road/path/fencing etc complete all as specified and directed.
M&L for painting of steel tubular swaged poles of LT over head line 9 M long complete including all MS chanel mounted/fixed with pole, earth protection & water pipe (if exists) with two coat of aluminium paint and providing 05 Nos bands/ straps with synthetic enamel paint (black and yellow 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on black circular background complete all as specified and directed.
M&L for painting to RCC pole 8.5/9.00 metre long after scrapping of old painted surfaces and applying two coats of cement based paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion including MS frames like channel,clamps, angle, D-clamps etc with two coats of synthetic enamel paint of suitable colour complete all as specified and directed.
S&F in repairs Galvanised mild steel tubing, 'Light grade' of following bore complete with all fittings, laid in trenches/ under roads, drain , paths, fixed to poles/ walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately)
50 mm bore
80 mm bore
M&L for line separator PVC type with clamp including fixing with overhead lines of multi conductor of ACSR as and where directed to prevent short circuiting of phase/neutral conductors mutually complete all as specified and directed of following ways:-
Line separator 2way
Line separator 3 way
Materials and Labour for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5M below normal ground level connected to GI wire 4mm by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm (Reinforced with 8 mm dia. TMT bars @ 150 mm, center to center both ways) with one handle for lifting made out of 8 mm dia. MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing light grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown on electrical plate No 3 of SSR Part-I (2009) complete as specified and directed complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level, connected to GI earth strip size of 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part I connected to earth test point all as specified or indicated including excavation and connected earth work, in soft/loose soil, removing soil upto 50m, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI medium grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 12mm dia bars, funnel, strainer, alternate layer of charcoal dust and common salt and testing on completion, complete all as specified and directed.
M&L for Cleaning of electric substation by uprooting unwanted grass, bushes and trimming of branches, surface dressing not exc.15cms deep in loose/soft soil to cut the grass,throne busehs and other any type of grass upto root level surrounding the installation and depositing the same at nearby garbage pit, refreshing and re-spreading aggregates inside the premises of sub station if any including cleaning of road/path/fencing etc, maintenance of transformer platform all as specified and directed.
M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate as in foundations of Stay and filling of mass concrete complete all as specified. (For Transformer/panel Fencing Area/LT/HT poles/installation area)
Material and labour for painting of pole number using stensils of letter size 75mm height with white synthetic enamel paint over black background complete all as specified and directed.
Material & Labour for fabrication of Sheet metal enclosure, powder coated of Timelite Distribution Boards for automatic Switching of street lights internally pre wired by using suitable copper lugs including fixing with MS Clamp 40X5 mm to steel/RCC poles incl connection consisting of the following: (i) Digital time switch 24 hrs operation 240 Volts Cat Part No.TL032DB0 of Indoasian or Equivalent of Legrand/L&T (ii) 3 pole contactor 40Amps Cat Part No.Cat No. CS 94190 of L&T (iii) MCB FP 32 Amps Cat Part No. Cat No. BB40320C of L&T or Equivalent in Legrand/Schneider
Material and labour Thermoplastic Cable Junction Boxes IP66/67 "weather proof", for outdoor installation with knockouts for cable entry with terminals suitable for 10-16sqmm cable of Size 155 x 210 x 92 mm incl busbar mounted on insulator and MCB SP 6 Amps-1 No, including necessary civil works and connecting all incoming and outgoing wires with AL lugs of appropiate sizes and complete all as specified and directed . Make Cat No. KF1616G of Hensel or euivalent in syntex
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick frame workand tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 250 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 200 Amps, 36 kA for out going -01 Nos MCCB 4 pole, 415 Volts, 125 Amps, 25 kA for out going -02 Nos MCCB 4 pole, 415 Volts,63 Amps, 25 kA for out going -02 Nos
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 160 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 63 Amps, 25 kA for out going -06 Nos
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 160 Amps, 25 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 63 Amps, 25 kA for out going -04 Nos
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected by engr-in-charge comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 200 Amps, 36 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts, 160 Amps, 25 kA for out going -04 Nos
Supply, install, testing & commissioning of LT panel board CPRI approved, outdoor type, factory made fabircated to CRCA sheet of 3.15 mm thickness, angle iron of size 40X40X6mm thick frame work and tee section (frame) of suitable size double door front/rear opening and locking arrangement, floor mounted on plateform of suitable size, Al bus bar chamber (enclosed) incl rust free spray painting with two coat of synthetic enamel paint over a coat of red oxide primer mounted on PCC blocks, fixed with grouted bold, nuts and washer and making complete connection in all recpects as diected comprising of following accessories:- BUS-BAR & INTERNAL CONNECTIONS: The bus-bars shall be made up of 04 Nos tinned alluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables. INCOMING : MCCB 4 pole, 415 Volts, 125 Amps, 25 kA (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete -01 Nos OUTGOINGS : MCCBs with thermal magnetic release, adjustable short circuit & adjustable overload setting incl electric connection complete. MCCB 4 pole, 415 Volts,63 Amps, 25 kA for out going -06 Nos
D G Corporation
Anil Kumar Sarmah
M/S Inder SINGH SABARWALL
M/S Barua Enterprise
shyam constructions
Sibson Constructions And Co
AVASANA SOLUTIONS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .