Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.7 LAccepted-Finance | 1 | Accepted-Finance OK | |
| 2 | 2₹9.9 L+₹19,387 (2.00%)Accepted-Finance | 2 | Accepted-Finance OK | |
| 3 | Rejected-Technical | - | Rejected-Technical DD AND EMD NOT UPLOADED |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
22 Jun 2022, 2:00 pmClosed
EXECUTIVE ENGINEER JPDCL ELECTRIC DIVISION RAJOURI
EXECUTIVE ENGINEER JPDCL ELECTRIC DIVISION RAJOURI
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING FOR CREATION OF 1X100 KVA S/STN ALONG WITH HT/LT NETWORK AT PHE CHAWARIAN CHRINGLE SUNDERBANI ON TURNKEY BASIS.
2022_PDD_169874_1
EDR/04 of 2022-23 Dated 19/05/2022
Open Tender
Electrical Works
Item Rate
60 days
RAJOURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
EXECUTIVE ENGINEER JPDCL ELECTRIC DIVISION RAJOURI
₹20,000
27 Aug 2022
19 May 2022
24 Jun 2022
20 May 2022
22 Jun 2022
20 May 2022
Amount
11 KV (HT) Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage, Delivery at Site including handling, preservation and proper storage at site.
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site of 9 Mtr. Long ST Poles (410, SP-33) (As per recommended IS/REC Standard)
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site of 8 Mtr. Long PCC Poles (WL-200KG) (As per recommended IS/REC Standard)
Conductor with PG clamps of required size (as per site requirement) 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
GI Channel cross-arm (75 x 40x6mm) with Angle Braces, Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard)
11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
Galvanized Nuts and Bolts of sizes.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Supplying of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150mm on pole for earth connection (As per recommended IS/REC Standard)
Supply and laying of Cement bottoming with 1:2:4 mix as per REC standards for ST Poles 0.5 cum/pole in size of 600x600x1800 mm, muffing 20 cm above ground level, including sturrering, plaster and curing of concrete. Refilling the leftover pit after concreting with soil and boulders) NOTE: Please refer Pole drawings for details.
Supply and painting of each Pole along with accessories by 1 coat red oxide paint and 2 coats of aluminium paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminium paint)
Erection/Installation, Testing and commisioning of material supplied at Sl. No-1.1
Erection/Installation of 9 Mtr. Long ST Poles (410, SP-33) (As per recommended IS/REC Standard)
Erection/Installation of 8 Mtr. Long PCC Poles (WL-200KG) (As per recommended IS/REC Standard)
Laying, stringing and binding of conductor including joints with PG clamps of required size (as per site requirement) 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
Erection/Installation of GI Channel cross-arm (75 x 40x6mm) with Angle Braces, Pole Top Bracket (50x50x6 mm) including back clamps of 50X8 mm for fixing Cross arm and pole top bracket without making holes in the ST pole as per REC standard for single pole structure. NOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard)
Erection/Installation of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
Erection/Installation of 11 kV Disc Insulators (polymer) Complete with fittings (45KN) depending upon conductor size. (As per recommended IS/REC Standard)
Fixing of Galvanized Nuts and Bolts of sizes.
Erection/Installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Fixing of pole Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip(25x3) to each HT pole including supply and welding of GI channel 70x40x150mm on pole for earth connection (As per recommended IS/REC Standard)
11/0.433 kV Distribution Transformer (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage, Delivery at Site including handling, preservation and proper storage at site of 11/0.433 kV Distribution Transformer.
100 kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Al Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard)
11 Mtr. Long ST Poles (410 SP-56) (As per recommended IS/REC Standard)
Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard)
11 kV Horn, Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard)
11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard)
GI channel/angle cross arms including fixing GI channels ( 100x50x6mm) / (75x40x6 mm) / angles(50x50x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles. (As per recommended IS/REC Standard)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Un Armoured Single Core XPLE, FRLS Cable (185 mm2) (As per recommended IS/REC Standard)
11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard)
Galvanized Nuts and Bolts of sizes.
Sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps. (As per recommended IS/REC Standard)
Erection/Installation, Testing and commisioning of material supplied at Sl. No-3.01
Installation of 100 kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Al Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard)
Erection of 11 Mtr. Long ST Poles (410 SP-56) with pit excavation (As per recommended IS/REC Standard)
Installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard)
Installation of 11 kV Horn, Gap Fuse Set, 3-phase, 100A (As per recommended IS/REC Standard)
Installation of 11 kV, G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard)
Erection of GI channel/angle cross arms including fixing GI channels ( 100x50x6mm) / (75x40x6 mm) / angles(50x50x6 mm) with 50X8 mm back clamps without drilling/punching holes in the poles. (As per recommended IS/REC Standard)
Erection Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Laying and Fixing of Un Armoured Single Core XPLE, FRLS Cable (185 mm2) (As per recommended IS/REC Standard)
Fixing of 11 kV Pin Insulators (polymer) with Pins ( 5 KN) (As per recommended IS/REC Standard)
Installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard)
Fixing of Galvanized Nuts and Bolts of sizes.
Excavation of Earthing Pits of dia = 600 mm and depth= 3000 mm, Supplying and fixing of Sub station earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 no for neutral earthing and 25X3 mm 2 nos (for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) GI Nuts, Bolts and Clamps, refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover including provision of salt and charcoal as per requirement. (As per recommended IS/REC Standard)
LT Line (Note: For detailed specifications please refer attached SBD which forms a part of the tender)
Supply, Loading, Transportation, insurance, Unloading, Carriage, Delivery at Site including handling, preservation and proper storage at site.
Supply, Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site of 8 Mtr. Long PCC Poles (WL-200KG) (As per recommended IS/REC Standard)
Conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
GI Mukky clamps with LT Shackle insulators(polymer)16KN with GI back clamps to be fixed without drilling/punching of holes on ST poles. (As per recommended IS/REC Standard)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Galvanized Nuts and Bolts of sizes.
Erection/Installation, Testing and commisioning of material supplied at Sl. No-5.1
8 Mtr. Long PCC Poles (WL-200KG) with pit excavation (As per recommended IS/REC Standard)
Laying, stringing and binding of conductor including joints with PG clamps of required size 30 mm2 ACSR ( Weasel) (As per recommended IS/REC Standard)
Fixing of GI Mukky clamps with LT Shackle insulators(polymer)16KN with GI back clamps to be fixed without drilling/punching of holes on ST poles. (As per recommended IS/REC Standard)
Installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete for 11 KV Tension points. (As per recommended IS/REC Standard)
Fixing of Galvanized Nuts and Bolts of sizes.
KHAN ELECTRICAL WORKS & CONSTRUCTIONS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .