Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹48.3 L+₹6.5 L (15.4%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in requisite category |
Tender Value
₹48.3 L
EMD Value
₹96,500
Closing Date
7 Sept 2022, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
SPECIAL REPAIR TO OVERHEAD SHED OF MAIN GATE AND LT DISTRIBUTION LINE WITH UNDERGROUND CABLING AND ASSOCIATED WORKS AT PHASE II AREA NEAR POS QUARTER AT NAVAL STATION BHEEMUNIPATNAM UNDER GE (P) NAVY KALINGA VISAKHAPATNAM
2022_MES_544546_1
GE (P)/N/K/8943 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a(i), b(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹96,500
Yes
28 Nov 2022
10 Aug 2022
9 Sept 2022
10 Aug 2022
7 Sept 2022
24 Aug 2022
Amount
Demolition of unreinforced cement concrete in ground floor and pavings n. exc. 15cm thickness (Below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed.
M & L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in concrete bed all as specified and as directed.
M & L for TMT steel bars 10 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for TMT steel bars 5 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete)e in foundations, including rafts, footings, plinth beams, bases for columns, etc. basement slabs, under reamed piles and mass concrete complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) in columns, pillars, piers posts and struts complete all as specified and as directed.
Use and waste of formwork to sides of foundation/ footings, plinth beams and similar work for rough finished surfaces complete all as specified and as directed by the Engineer-in-Charge.
Use and waste of Formwork to sides of pillars posts struts, piers, columns and stanchions all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated soil n exc 50 m and depositing where directed at a level n exc 1.50 M above starting point
Dismantling framed trusses n exc 10 M in span complete all as specified and as directed.
Dismantling structural steel work complete all as specified and as directed.
S&F in steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade st 240
Erection and fabrication only in steel work in structure including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Grade ST 240
S & F 12 mm dia mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed the both ends each screwed ends to be fitted with washer and one hexagonal or square nuts exc 15 cm and n exc 22.5 cm long complete all as directed.
M&L mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 W (Gde-E-250) quality A complete all as specified and as directed.
Dismantling corrugated or plain steel sheeting any gauge,thickness,including Nainital or similar pattern roof coverings complete all as specified and as directed
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Applying two coats of high build chlorinated rubber paint over two coats of epoxy micaceous iron oxide paint protection with total thickness not less than 100 microns over two pack zinc rich epoxy primer with total thickness not less than 45 microns including preparation/ cleaning of steel surfaces
M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified.
Demolition of cement concrete in ground floor and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M&L for hardcore of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M&L 100 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and as directed
M&L for non skid ceramic coloured joint free tiles of size 400 x 400 x 6-7 mm thick as in floors etc. set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over screed bed or bedding layer 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L for non skid/matt finish joint free ceramic tiles of size 400 x 400 x 6-7 mm thick as in vertical surface like skirtings dado etc. set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over backing coat of mortar 10mm thick in CM 1:3 complete all as specified and as directed by the Engineer-in-Charge.
M&L for 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs including strips in door portion, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed or bedding layer of CM 1:4, 20 mm thick complete all as specified and as directed by the Engineer-in-Charge.
S&F Glow sign board of size 4 mtr x 1.20 mtr X 0.20 mtr with acrylic sheet 4 mm thick, on front, LHS & RHS and aluminium composite panel board on rear side with letters along with depot emblem including LED back lights, fixed on metal frame complete all as specified and as directed.
S&F Metallic sign board of ornamental design size n exc 600 x 900 x 100 mm complete all as specified and as directed.
S&F Acrylic letters in any language, fixed with anchor fasteners on walls with the following sizes:-
(a) Letters of size 32 cm x 40 cm
(b) Letters of size 22 cm x 27 cm
Taking down chowkhats or frames not exc 1.5 sq m n exc 4.0 sq m with shutters ( without taking off shutters from the frames)
Taking down chowkhats or frames exc 1.5 sq m n exc 4.0 sq m with shutters ( without taking off shutters from the frames)
S&F UPVC window,(unplastisized poly-Vinyl Chloride) sliding windows multi-chambered and stiffened framed windows using 88mm x 52mm size sections all-round as main frames and shutters made with profile sections of size 57mm x 42mm, including the cost and fixing of 5mm thick clear float glass in shutters and stainless steel wire mesh shutters shall have well defined welded corner joints without any gaps, fixed the window unit to the existing masonry with anchor fasteners as required. The shutters shall have necessary handles and other associated fittings to facilitate smooth operation. Both the frames and the shutters shall be reinforced with GI profiles of thickness 1.25mm the entire window is covered with MS powder coated tube of size 40mm x 20mm all-round the frame the frame section, 10mm square bars horizontally placed at 120mm C/C and suitably placed vertically to avoid buckling and providing structural strength, Minimum weight shall be 10kg/Sqm and fixed to UPVC frames with suitable fasteners. The gaps between the window frames and masonry walls shall be filled with silicon or with any other suitable filler materials complete all as specified and directed. Make : Rajshri Plastiwood/ Sintex/ Duroplast Extrusion Pvt. Ltd
S & F Powder coated Aluminium grill/Deco grill for Windows , Ventilators etc
M & L for complete removal of existing treatment on internal walls and applying two coats of Oil bound distemper over wall care putty of 1 mm thick all as specified and directed
M & L for complete removal of existing treatment on walls and applying two coats of Exterior emulsion weather coat paint over a coat of primer over wall care putty of 2 mm thick for external surface on walls complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparation of old surfaces and applying three coats of white wash on Ceiling
Taking down carefully existing aluminium /copper conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification complete all as specified and as directed.
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes , concealed type with 3 mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
All as per Item no 42 here-in-before but for one fan /E Fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item no 42 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item no 42 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item no 42 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4.0 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 4.0 sqmm as in continuous earth wire drawn into and including concealed PVC conduit medium grade 25mm dia ISI marked complete with fittings and fixings accessories complete and including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends with taking down of old unserviceable sub main wiring and making good disturbed surface complete all as specified and as directed. (NOTE: 3 runs of 4.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
M&L for sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6sqmm size and Size and drawing into and including concealed PVC conduit 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6 Sqmm single core as earth continuity wire all as specified and as directed. (NOTE: 3 runs of 6.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Supply and fixing modular plate switch flush type, single pole one way 6 Amps 250 volts.
Supply and fixing modular plate switch flush type, single pole one way 16 Amps 250 volt all as specified
Supply and fixing modular socket 6 Amps 5 pin all as specified and as directed.
Supply and fixing modular socket 6-16 amps 2/3 pin combined shuttered all as specified and as directed.
Supply and fixing modular step fan speed regulator 120 w, 2 module all as specified and as directed
Supply and fixing modular plates white colour suitable for flush metal boxes for mounting modular switches or sockets etc for 8 modules.
All as per item No. 54 here-in-before but for 6 modules all as specified and as directed.
All as per item No. 54 here-in-before but for 3 modules all as specified and as directed.
All as per item No. 54 here-in-before but for 2 modules all as specified and as directed.
Supply and fixing Flush metal box 1/2 module all as specified and as directed.
All as per item No. 58 above but for 6 modules all as specified and as directed.
All as per item No. 58 above but for 3 modules all as specified and as directed.
All as per item No. 58 above but for 8 modules all as specified and as directed.
S&F ceiling rose surface bakelite three terminals all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 6 way, Double door 415 Volts all as specified and as directed.
S&F sheet metal enclosure for MCB DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar all as specified and as directed.
Supply and fixing in proper position MCB four pole of capacity 63 amps, 415 Volts C-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position all as specified and as directed.
Supply and fixing in proper position MCB double pole of capacity up to 40 Amps, 240 Volts C-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing of single pole and neutral enclosure of 20 Amps, 240 volts with a two pin and earth plug and socket complete with one double pole MCB directed by Engr--in-Charge
Supply and fixing Ceiling Fan of 1200 mm Sweep, 32 w decorative blades metallic white energy efficient saving with incl clamps and hook at proper position, necessary accessories etc all as specified and as directed
Supply, fix and install cable tray for cable arrangement and arranging the cable by disconnecting the power supply and giving support using a pre fabricated flange or GI channel, the size of the cable as per site keeping the distance between the cable as per calculation and tie the cable using cable tie and label the cable as required all as specified and directed.
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed (Note : Compacted thickness shall only be measured and paid)
Supply and lay bricks common burnt clay building bricks sub-class B of size 230x115x75 complete all as directed by Engr-in-Charge.
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3.5 core all as specified and as directed
Dismantling of ACSR conductor of any make and any size from any height of poles and removing for taking as schedule of credit complete all as specified and directed by the Engineer -in- Charge
Dismantling of insulators any type any make any size from any height of poles and removing for taking as schedule of credit complete all as specified and directed by the Engineer -in- Charge
Dismantling of Stay assembly any make and any size from any height of poles and removing for taking as schedule of credit complete all as specified and directed by the Engineer -in- Charge
Dismantling cross arms of M.S channels or angle sections etc. of any size from any height of poles, 2/4 pole structures and removing for taking as schedule of credit complete all as specified and directed by the Engineer -in- Charge
Supply, laying and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed by the Engineer- in- charge
Supply, laying and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 35 sq mm 4 core complete all as specified and directed by the Engineer- in- charge
Supply, laying and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed by the Engineer- in- charge
Supply, laying and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed by the Engineer- in- charge
Supply, laying and testing LT UG cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and directed by the Engineer- in- charge
Supply and fix HOT moulded (FRP) junction box for street light pole with locking arrangement with IP -65 protection of size 140x140x95 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP with two steel bracket to fix with pole and aluminium bus bar of rating 200Amps complete all as specified and directed by Engr - in - charge.
Supply and fix PVC insulated sheathed multi stranded copper conductor cable of size 1.5 Sqmm 3 core all as specified and directed by Engr-in Charge
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 6 to 16 sqmm, Indoor/Outdoor type complete all as specified and directed by the Engineer- in- charge
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Aluminium conductor cable of size 25 to 50 sqmm, Indoor/ Outdoor type complete all as specified and directed by the Engineer- in- charge
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly and preferably vertically in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galavanised lead wire 4.0 mm dia (upto 7.5 M in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3, connected to earthing with DBs all as specified including earth work and excavation in any type of soil, PCC 1:3:6 type C1 chamber & RCC 1:2:4 type B1 cover 40mm thick, with 8mm dia steel deformed (TMT bars) reinforcement at 150mm c/c both ways, 20mm dia GI medium grade pipe for watering , water funnel complete all as specified and testing on completion.
Supply and lay un-reinforced precast concrete cable cover class LV, type 1, flat, size 250mmx150mmx40mm for protection of cable, laying in trenches complete all as specified and directed by Engr-in-charge.
Supply and Lay galvanised steel tube, light grade 40 mm dia for cable protection complete all as specified and directed by Engineer - in - Charge.
Supply and Lay galvanised steel tube ,light grade 80 mm dia for cable protection complete all as specified and directed by Engineer - in - Charge.
Supply, install ,test & commissioning LT panel Outdoor, Floor mounted/pedestal type,cubical,self supported,CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 65 protection with dust and vermin proof etc,fabricated out of 3.15 mm CRCA sheet duly powder coated, mounted /fixed on and including MS angle iron stand of 1 Mtr height (50 Cm above FFL and 50 Cm below FFL), fabricated out of 50 X50 X6 mm thick MS angles duly painted with two coats of Black enamel synthetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables & interconnections od suitable size/ capacity of copper Strips for switch gear connections from main bus bar, earth bus strip of 25 x 3 mm size for entire length of panel, Suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming and outgoing cables etc. complete all as specified and directed by the engineer -in - charge including and accommodating the followings:
(a) MCCB TPN 400 Amps, 50 Hz, 415 volts, 36 kA, thermal magnetic release - 1 No (Incoming)
(b) MCCB TPN 320 Amps, 50 Hz, 415 volts, 25 KA, thermal magnetic release -1 No (outgoing)
(b) MCCB TPN 100 Amps, 50 Hz, 415 volts, 18 KA, thermal magnetic release -6 No (outgoing)
(d) LED type three Phase indicator with controlling fuses for RYB -01 set
(e) 3 phase multifunction energy meter (voltage 0-500V ampere 1-125 A and energy consumption in KWH or units consumption including CT's and PT's having CTs ratio 400/ 5A)
(f) Electrolyte copper busbars PVC colour sleeved 400 Amps capacity TP and 250 Amps for neutral mounted on hygroscopic insulator duly colour coded RYB & Green sleeves
(g) Digital time Switch with contactor 2NO+2NC 4 pole 63 amps
Supply, install ,test & commissioning LT panel Outdoor, Floor mounted/pedestal type,cubical,self supported,CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 65 protection with dust and vermin proof etc,fabricated out of 3.15 mm CRCA sheet duly powder coated, mounted /fixed on and including MS angle iron stand of 1 Mtr height (50 Cm above FFL and 50 Cm below FFL), fabricated out of 50 X50 X6 mm thick MS angles duly painted with two coats of Black enamel synthetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables & interconnections od suitable size/ capacity of copper Strips for switch gear connections from main bus bar, earth bus strip of 25 x 3 mm size for entire length of panel, Suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming and outgoing cables etc. complete all as specified and directed by the engineer -in - charge including and accommodating the followings:
(a) MCCB TPN 320 Amps, 50 Hz, 415 volts, 25 KA, thermal magnetic release - 1 No (Incoming)
(b) MCCB TPN 250 Amps, 50 Hz, 415 volts, 25 KA, thermal magnetic release -2 No (outgoing )
(c) MCCB TPN 100 Amps, 50 Hz, 415 volts, 25 KA, thermal magnetic release -5 No (outgoing )
(d) LED type three Phase indicator with controlling fuses for RYB -01 set
(d) 3 phase multifunction energy meter (voltage 0-500V ampere 1-125 A and energy consumption in KWH or units consumption including CT's and PT's having CTs ratio 400/ 5A)
(e) Electrolyte copper busbars PVC colour sleeved 400 Amps capacity TP and 250 Amps for neutral mounted on hygroscopic insulator duly colour coded RYB & Green sleeves
Supply, install ,test & commissioning LT panel Outdoor, Floor mounted/pedestal type,cubical,self supported,CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 65 protection with dust and vermin proof etc,fabricated out of 3.15 mm CRCA sheet duly powder coated, mounted /fixed on and including MS angle iron stand of 1 Mtr height (50 Cm above FFL and 50 Cm below FFL), fabricated out of 50 X50 X6 mm thick MS angles duly painted with two coats of Black enamel synthetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables & interconnections od suitable size/ capacity of copper Strips for switch gear connections from main bus bar, earth bus strip of 25 x 3 mm size for entire length of panel, Suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming and outgoing cables etc. complete all as specified and directed by the engineer -in - charge including and accommodating the followings:
(a) MCCB TPN 250 Amps,50 Hz, 415 volts, 50 KA, thermal magnetic release - 1 No (Incoming)
(b) Electrolyte copper busbars PVC colour sleeved 400 Amps capacity TP and 250 Amps for neutral mounted on hygroscopic insulator duly colour coded RYB & Green sleeves
Supply, install ,test & commissioning LT panel Outdoor, Floor mounted/pedestal type,cubical,self supported,CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides IP 65 protection with dust and vermin proof etc,fabricated out of 3.15 mm CRCA sheet duly powder coated, mounted /fixed on and including MS angle iron stand of 1 Mtr height (50 Cm above FFL and 50 Cm below FFL), fabricated out of 50 X50 X6 mm thick MS angles duly painted with two coats of Black enamel synthetic paint over one coat of red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables & interconnections od suitable size/ capacity of copper Strips for switch gear connections from main bus bar, earth bus strip of 25 x 3 mm size for entire length of panel, Suitable size of MS gland with gland plate and aluminium lugs/thimbles for all incoming and outgoing cables etc. complete all as specified and directed by the engineer -in - charge including and accommodating the followings:
(a) MCCB TPN 250 Amps,50 Hz, 415 volts, 25 KA, thermal magnetic release - 1 No (Incoming)
(b) MCCB TPN 100 Amps, 50 Hz, 415 volts, 25 KA, thermal magnetic release - 6 No (outgoing )
(c) LED type three Phase indicator with controlling fuses for RYB -01 set
(d) 3 phase multifunction energy meter (voltage 0-500V ampere 1-125 A and energy consumption in KWH or units consumption including CT's and PT's having CTs ratio 250/ 5A )
(e) Electrolyte copper busbars PVC colour sleeved 400 Amps capacity TP and 250 Amps for neutral mounted on hygroscopic insulator duly colour coded RYB & Green sleeves
M&L for boring of holes under road, pavement, hard standing by trenchless technology insertion of HDPE pipe of 150mm bore dia suitable for 0.4 MPS working pressure for cable protection complete all as specified and directed by Engr-in-charge.
M&L for cleaning the swaged steel tubular street light poles 9 / 11 meters height including GI pipe of street light fitting and prepare surfaces cleaning including scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of aluminium paint over one coat of metal primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping complete all as specified and directed by Engineer-in-Charge.
SWATHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .