| 1 | L1₹47.4 LAccepted-AOC 1A BASEMENT 30 31 RAJA HOUSE NEHERU PLACE NEW DELHI | NEW DELHI | NEW DELHI | DELHI | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹47.6 L+₹26,590 (0.56%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹47.9 L+₹49,979 (1.05%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance HIGHER BID | |
| 4 | L4₹48.0 L+₹62,052 (1.31%)Rejected-Finance 10 ABHAY GARH SCHEME CENTRAL SCHOOL AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance HIGHER BID | |
| 5 | L5₹49.7 L+₹2.3 L (4.86%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L5 | Rejected-Finance HIGHER BID |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011 Rajasthan
PROVISION OF STANDBY POWER SUPPLY AND ALLIED WORKS FOR SATCOM UPGRADE EQUIPMENT AT ER-II AT AF STN JODHPUR
2023_MES_577839_1
85971/E8
Open Tender
Civil Works
Item Rate
120 days
GE AF JODHPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF JODHPUR
₹96,000
Yes
6 Jul 2023
30 Jan 2023
1 Mar 2023
30 Jan 2023
27 Feb 2023
13 Feb 2023
Amount
S&F 4 Pole MCCB 100 Amp thermal magnetic type, 50 Hz, 415 V with rupturing capacity 25 KA With MCCB box, 2mm thick duly powder coated all as specified and directed by Engineer-in-Charge.
Supply and fix ON LOAD change over switch 415V,AC in sheet steel enclosures version is with CO with handle 4 pole of capacity 250 Amps complete all as specified and directed by Engineer-in-Charge.
M&L for earthing to bore earthing 150 mm dia depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia ,15cm C/C on both side of the pipe including lowering in bore well upto the depth of 49mtr and one mtr above the ground level . the pipe electrode should be filled around commercial salt chorcol dust /Breeze and magnesium phosphate of 30 cm layer each upto the fill length of pipe. The borewell should have 12 mtr of length 150mm dia MS pipe, thickness 3mm for protection of bore well . Welding of GI strip 50x6 mm on earth electrode GI pipe 50mm dia upto the 20 mtr below ground level 15 mtr from the bore well to test point. Necessory water connection by GI steel tubing 15 mm dia complete all as directed by EIC. GI strip more than 35 Mtr will be measured and paid seperatly Complete all as specified and directed by Engineer-in-Charge.
Supply & fix copper strip 32mm x 6 mm complete with saddles and fixing screws on wall complete all as specified and directed by Engineer-in-Charge.
Supply and Fix unarmoured copper cable 1100 volts grade 35 sqmm 4 core of size fixed on wall with all connected items used for main supply cable for ups ,satcom etc Complete all as specified and directed by Engineer-in-Charge.
Supply and Fix uarmoured copper cable 1100 volts grade16 sqmm 4 core of size fixed on wall with all connected items used for outgoing cable for various interconnection and load cable Complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing uarmoured copper cable 1100 volts 10 sqmm single core of size fixed on wall with all connected items used for earth continuity conductor Complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core ( trenches/ducts used for DG set to AMF panel etc)Complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core Complete all as specified and directed by Engineer-in-Charge.
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven generating set including acoustic enclosure as per current CPCB norms automatic mains faillure panel fully wired alternator AC to give an output of 125 KVA /100 kw ,continuously rating at a PF of 0.8 lagging, 415 volts , AC 3 phase 4 wire 50 HZ ,1500 RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads & other accessories etc comprising of following:- Diesel engine : Water cooled turbocharger of suitable BHP at 1500 RPM confirming to BS 5514 & ISO 3046 with an overload capacity of 10 % for one hour in any 12 continuous hours operation and designed and tested for 50°C ambient temperature with standard fittings. Alternator:- 125KVA alternator, 3 phase, Power factor:- 0.8, Rated generating voltage:- 230/415V, screened protected, revolving field, self excited, self regulated through an AVR, the alternator has following features:-(i) 'H' class insulation (ii) IP23 protection with insulation class H (iii) +/- 1.0% voltage regulation (maximum) in static condition (iv) permissible overload of 10% for one hour in 12 hours of operations Control Panel : Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. including the following:- PowerCommand Controller Aluminum bus bars with suitable capacity with incoming/ outgoing terminals Indicating lamps for ‘Load ON’ and ‘Set Running’ Instrument fuses duly wired and ferruled MCCB of suitable rating with overload and short circuit protections
AMF panel AMF Panel outdoor type, 125KVA DG Set with alluminium busbar of capacity 250Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3.15 mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 200Amps consisting the following:- INCOMING from 125 KVA (i) MCCB thermal magnetic adjustable type 200 Amp FP 25 KA - 01 No (ii) Spreaders 200 Amps FP - 01 Set (iii) Extended Rotary handle 200 Amps FP - 01 No (iv) Earth fault module - 01 No (v) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 250/5A CL-1.0 10 VA - 03 Nos (vii) Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch 200 A for bypassing of AMF panel - 01 No Outgoing(i) MCCB thermal magnatic adjustable type 200 Amp FP 25 KA - 01 No(ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay set of 01 (iv) SMPS 12/24V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No(vi) Digital Amp meter 12/24, DC - 01 No(vii) Digital Volt meter 12/24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No Acoustic Enclosure : Powder coated weather proof canopy. Engine and alternator mounted on AVM mounts, with silencer and SS exhaust below optimised to meet stringent CPCB norms for sound and emission, Baserail with drawout type fuel tank, drain plug, inlet and outlet connections, airvent, level gauge etc PCC Plateform : size as per OEM recommendation Batteries : Volts and AH as per OEM.
M & L in repairs for Earthing complete with galvanised steel earth electrode 60cm×60cm×6mm thick, buried directly in ground vertically to depth not less than 2.25 metres deep below normal ground level with top edge of the earth plate a depth not less than 1.5 metres below normal ground level, connected to and including galvanised iron earth strip 32X6mm as earth lead by means of bolts, nuts, check nuts and washers etc made of galvanised iron and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) type C1 in chamber, precast RCC 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (weight not less than 4.00kg/sqm) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed by Engineer-in-Charge. NOTE:- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 metres and beyond 7.5 metre shall be measured and paid for separately.
Supply and fix tempra plug and socket including DB of 63 A, 3P+N+E-5P suitable for flush mounting and surface mounting Complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches,in soft/loose soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. Or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-in-Charge .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material & labour for Tibba sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
Material & labour for stone slab 40mm to 50mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50cms in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
Supply, fixing, installation, testing & commissioning air cooled inverter type with non CFC gas split air conditioner capacity 2 TR, BEE 5 star rating comprising of indoor & outdoor unit. The evaporator & condenser coil shall be made of copper, including control wiring, stand for fixing outdoor unit on wall/floor, insulated copper tubing for connection the indoor and outdoor all as specified and directed by Engineer-in-Charge. NOTE:- The cost of copper tubing & control wire upto 3 Mtr shall be deemed to included in above quoted rates.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 05 KVA all as specified and directed by Engineer-in-Charge.
Supply and fixing Wiring for circuit/submain wiring alongwith earth wire with the2x4.0 sq. mm + 1x2.5 sq. mm earth wire of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required all as specified and directed by Engineer-in-Charge.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps,240 volts all as specified and directed by Engineer-in-Charge.
S & F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43-IK 09 with reversal double door, recess mounted, having insulated 200 amp tinned copper bus bar , neutral bus bar, earth bar, din bar detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways all as specified and directed by Engineer-in-Charge.
Material & labour for canopy stand for outdoor split type AC unit with and including angle iron 40mmX40mmX6mm, with GI sheet on the top, including welding, cutting and installation at site complete all as specified & directed by Engineer-in-Charge.
Shri Electrical Enterprises
SANJOLI CONSTRUCTION COMPANY
RISING ELECTRICALS
Nvimal Engineers and Contractor
M/s Chopra Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .