Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical DEPOTPARA PO BINNAGURI 735203 DISTT JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical MASTER QUARTER PARA WARD NO 12 DHUPGURI 735210 JALPAIGURI WB | COOCHBEHAR | WEST BENGAL | 735210 | Admitted-Fee/PreQual/Technical |
Tender Value
₹43.5 L
EMD Value
₹87,040
Closing Date
18 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
PROVN OF TWO BUS STAND AT OFFRS RWA, FOOTPATH NEAR OFFRS RWA, INTELLIGENCE AND MAP ROOM WITH RACKING AND SHELVING and INBUILT ALMIRAH, KOTA STONE 550 SQM IN BLDG NO P-28 AND 04 X CAR PARKING SHED AT OFFICE COMPLEX UNDER GE NORTH BINNAGURI
2025_MES_723987_3
8701 / 27 / 2025-26 / 15 / E8
Open Tender
Civil Works
Item Rate
180 days
Binnaguri cantonment
D class catg a(i)
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹87,040
Yes
8 Dec 2025
20 Nov 2025
20 Dec 2025
20 Nov 2025
18 Dec 2025
28 Nov 2025
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Soft/loose soil complete all as specified and as directed.
M&L for 75 mm thick cement concrete type D2 1:4:8 with 40 mm graded stone aggregate as in Sub base etc all as specified and as directed.
Supply only liquid water proofing compound conforming to relevant IS complete all as specified and as directed.
M&L for rolled mild steel work in tubular trusses such as roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing including distance pieces, cleats etcs including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St 240 complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggragate) as in foudnation filling and mass concrete complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in plinth protection finished fair and even without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metres and every change of direction and filling the same with & including bitumen and sand 1:3 by weight of grade 'A' complete with and including necessary form work etc complete all as specified and as directed.
M&L for preparation of new plastered surfaces on wall / ceiling / chajjas and applying Two coats of weather coat exterior pait over one coat of primer as per manufacturer instruction etc. complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregate as in foundation including rafts,footing,foundation beams ,plinth beams,bases for colums,etc complete all as specified and as directed.
M&L for reinforced cement concrete M-25 (Design Mix) using 20 mm graded stone aggregate as in Columns complete all as specified and as directed.
M&L for RCC M-25 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for formwork to chajjas including edges in rough finished surface of concrete flat complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part- I including testing on completion all as directed and as specified.
S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for treating the soil under plinth protection at the rate of 5 liters of emulsion per square meter of surface area complete all as specified and as directed.
screw holding strength to fix hinges and hold doors properly for a long life.)
M&L for machine cut kota stone slab flooring 18-20 mm thick over 15 mm thick cement screed bed cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
S&F MCB, Single pole & neutral, 35 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete as specified and as directed.
Supply & fix Ceiling fans with all accessories 230 V,1200 mm sweep BEE 5 star rated, conforming to IS 374:1979 complete with pre wired with 3 core cable completion all as directed and as specified.
, MS spring latch, MS Guard Bar/ grill etc complete with glazing bars including one shop coat of zinc chrome primer complete all as specified and as directed. Note:- (i) Rate quoted shall be deemed to be including of all fittings fixtures. (ii) Glass, wire mesh and painting only shall be measured and paid separately under relevant items of Sch. (iii) The Drawings referred above are available in the office of Engr-in-Charge and can be refereed in the office working hours if required.
S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up complete all as specified and as directed.
M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
M&L for preparation of old treated surface of ceiling by brooming down or steel wire brushing; scrapping down smoke root, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coats of colour wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery, electrical fittings, wiring etc of drops and splashes complete all as specified and as directed.
Use and waste of formwork to sides of columns,post ,struts,piers columns and stanchions complete all as specified and as directed.
S&F of Switch socket combination 2 and 3 Pin, 15/16 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and directed.
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tender.pdf
Tender Documents • 1.68 MB
BOQ_829516.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .