Loading…
Loading…
Tender Value
₹83.1 L
EMD Value
₹1.7 L
Closing Date
15 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
MAINTAINCE
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The firm/contractor should submit a valid "B" grade or above electrical Contractor license issued by the Government Electrical Licensing Board in favor of the Firm/contractor (OR) the site Supervisor should possess the necessary valid "B" grade or above electrical Contractor license issued by Government Electrical Licensing. A copy of the valid license shall be submitted with the offer. The offer without a copy of a valid "B" grade or above Electrical Contractors license shall be summarily rejected.
Similar Nature of Work: " Works of Installation, testing and commissioning of any type of centralized air conditioning/ centralized air cooling systems (with or without supply)"
47 conditions · 7 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. and corresponding documents shall be submitted by the tenderer as per the composition of the Firm.
The Bid Security shall be deposited either in cash through e- payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure- VIA of GCC and shall be valid for a period of 90 days beyond the bid validity period. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document within 5 working days of deadline of submission of bids.
Eligibility criteria :- Eligibility criteria shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
Tender Form (First sheet, Second sheet) of The GCC April 2022.
Certificate format (Affadivit) which available as Annexure - V in Mandatory documents. A facility has already created for online submission of Annexure V of GCC in IREPS module, uploading of physically signed Annexure V by tenderer has been discontinued.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.
The corresponding documents shall be submitted by the tenderer as per the composition of the Firm: Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) above. HUF: (i) A copy of a notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above. Partnership Firm: (i) All documents as mentioned in para18 of the Tender Form (Second Sheet). Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above. LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet). Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents andcreate liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer shall be required to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as per Clause No.5 of PART -1 of The GCC, April 2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Guntakal Division-Provision of Energy-Efficient Additional HVAC System through VRF Technology for the Operational Control Centre Building in Guntakal.
GTL-EM-09-2026-27
GTL-EM-09-2026-27
Open
Works - General
6 Months
Anantapur, Andhra Pradesh
₹0
₹1.7 L
15 May 2026
24 Apr 2026
1 May 2026
41 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 83,06,532 | ||
| — | 4.00 | — | — | ||
| Supplying, Installation, Testing & Commissioning of 20 HP Variable Refrigerant Flow air cooled Outdoor units of model no:20HP ODU IVRFB-20TCN of Bluestar Make having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) , microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Deg C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condensor should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. Supplying, Installation, Testing & Commissioning of 20 HP Variable Refrigerant Flow air cooled Outdoor units of model no:20HP ODU IVRFB-20TCN of Bluestar Make having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) , microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condensor fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Deg C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condensor should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building)The unit to be integrated with the existing BMS as per instruction of site Engineer. | — | — | — | 15,28,880 | |
| — | 9.00 | — | — | ||
| Supplying, Installation, Testing & Commissioning of 24 HP Variable Refrigerant Flow air cooled Outdoor units of model no:24HP ODU IVRFB-24TCN of Blue star Make having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) , microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Deg C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. Supplying, Installation, Testing & Commissioning of 24 HP Variable Refrigerant Flow air cooled Outdoor units of model no:24HP ODU IVRFB-24TCN of Blue star Make having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) , microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Deg C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building)The unit to be integrated with the existing BMS as per instruction of site Engineer. | — | — | — | 41,27,976 | |
| — | 2.00 | — | — | ||
| Supplying, Installation, Testing & Commissioning of 28 HP Variable Refrigerant Flow air cooled Outdoor units of model no:28HP ODU IVRFB-28TCN of Bluestar Make having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) , microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Deg C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. (For capacity <40 kWr ISEER 5.4, Capacity > 40 and <70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building)The unit to be integrated with the existing BMS as per instruction of site Engineer. | — | — | — | 10,70,216 | |
| — | 3.00 | — | — | ||
| Supplying, Installation, Testing and Commissioning of following minimum capacity and external static pressure VRF ceiling mounted high ductable type Indoor unit equivalent to VSD132A of blue star make equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, electronic expansion valve, corded remote control, outer cabinet, vibration Isolators, drain pan, drain pump, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor) | — | — | — | 1,83,018 | |
| — | 3.00 | — | — | ||
| Supplying, Installation, Testing and Commissioning of Direct Expansion Kit for 20 HP VRF system equivalent to VEAKIT-100. | — | — | — | 1,62,486 | |
| — | 3.00 | — | — | ||
| Supply of remotes for VRF conditioners. | — | — | — | 3,000 | |
| — | 195.00 | — | — | ||
| Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for suction and liquid lines, all accessories as per standards as required. | — | — | — | 1,19,925 | |
| — | 165.00 | — | — | ||
| Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per standards as required. | — | — | — | 1,90,905 | |
| — | 30.00 | — | — | ||
| Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per standards as required. | — | — | — | 22,170 | |
| — | 30.00 | — | — | ||
| Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per standards as required. | — | — | — | 38,580 | |
| — | 12.00 | — | — | ||
| Supply of refinets of VRF systems | — | — | — | 54,000 | |
| — | 420.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of CONTROL CABLING of 2C x 0.75 sq.mm and communication cabling (6C x 1.5Sq.mm Shielded) Copper for communication between indoor and outdoor units to be suitably laid in PVC conduit as per site requirement. | — | — | — | 1,04,076 | |
| — | 50.00 | — | — | ||
| Supply and erection of 2 inch PVC Drain Piping with insulation | — | — | — | 13,100 | |
| — | 30.00 | — | — | ||
| Supply and Installation of ISI marked 22G With G.I material which is fixed at plunems and starting of duct as per site enginner instructions | — | — | — | 44,250 | |
| — | 60.00 | — | — | ||
| Supply and Installation of ISI marked 24G With G.I material which for all for supply air duct as per site enginner instructions | — | — | — | 81,420 | |
| — | 10.00 | — | — | ||
| Supply & erection of GI duct damper in the Ducting as per site requirement and site enginners instructions | — | — | — | 6,370 | |
| — | 30.00 | — | — | ||
| Supply and Installation of Acostic insulation of 10mm which is fix for plunems and starting of duct for the above AC system | — | — | — | 26,550 | |
| — | 650.00 | — | — | ||
| Supply & erection of thermal insulation of ducts with 9 mm thick nitrile rubber faced with alluminium foil all round the duct as per instructions of site engineer | — | — | — | 57,850 | |
| — | 5.00 | — | — | ||
| Supply and erection of opposed blade MS volume control damper as per required for the site condition and instruction of site engineer. | — | — | — | 2,830 | |
| — | 500.00 | — | — | ||
| Supply, Laying, Testing and Termination of 4 core 16 sq.mm. PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 with latest amendments and with necassary lugs and terminations. | — | — | — | 4,68,930 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Master Tender Document
ATTACHMENT
GCC April 22 With Correction Slips
ATTACHMENT
SCOPEOFWORKFORWiring.pdf Scope of Wiring
ATTACHMENT
ListofLikelySuppliers.pdf
ATTACHMENT
SpecialContionsofcontractGTL-EM-09-2026-27.pdf
ATTACHMENT
MasterTenderdocumentGTL-EM-09-2026-27.pdf
ATTACHMENT
GCC_April-2022WithCorrectionSlips..pdf
ATTACHMENT
SCOPEOFWORKFORWiring.pdf
ATTACHMENT
RITESInspectionLr..pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .