| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.9 LAccepted-AOC 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | L1 | Accepted-AOC Lowest | |
| 2 | L2₹99.9 L+₹7.0 L (7.57%)Rejected-AOC ERNAKULAM KERALA 682017 INDIA UDYAM KL 02 0012741 | ERNAKULAM | KERALA | 682017 | L2 | Rejected-AOC Second Lowest | |
| 3 | L3₹1.1 Cr+₹12.1 L (13.1%)Rejected-AOC | L3 | Rejected-AOC Third Lowest | |
| 4 | L4₹1.2 Cr+₹26.4 L (28.4%)Rejected-AOC | L4 | Rejected-AOC Forth Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹97 L
EMD Value
₹50,000
Closing Date
28 Apr 2022, 1:00 pmClosed
Chief Executive Officer
Park Centre Technopark Phase I Campus Trivandtrum
Electrification Works at 2nd Floor of Thejaswini Building
2022_ETPK_486470_2
ETPK/PH-I/2022-23/E-02
Open Tender
Electrical Works
Item Rate
60 days
Technopark Phase I Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
₹50,000
Park Centre Technopark Phase I Campus
1 Jul 2022
14 Apr 2022
29 Apr 2022
15 Apr 2022
28 Apr 2022
18 Apr 2022
18 Apr 2022
Amount
ELECTRICAL PANELS
Incomer:
400 A , 4P ,ATS automatic and manual with inbuild time delay,Primary protection against over voltage,under voltage,single phasing,etc are required-1 nos
400A, 50 kA or above,4P MCCB Microprocessor type, variable settings ,Rotary handle,Spreader Terminals, etc are required-1No
400/5A,15 VA,Cast resin type ,CL:1 ,CT-3 Nos
250/5A,15 VA,Cast resin type ,CL:1 ,CT-1 Nos
Digital Ammeter (Accuracy Cl 1)(0-400A)-3 Nos
Outgoings:
100A,25kA, 4P,Thermal magnetic type MCCB with Rotary handle,Spreader Terminals, etc are required -4 nos
125A,30kA, 4P,Thermal magnetic type MCCB with Rotary handle,Spreader Terminals, etc are required -3 nos
160A,25kA, 4P,Thermal magnetic type MCCB with Rotary handle,Spreader Terminals, etc are required -1 nos
200A,36kA, 4P,Thermal magnetic type MCCB with Rotary handle,Spreader Terminals, etc are required -1 nos
APFC PANEL: Design, supply, erection, testing and commissioning of cubicle type floor mounting made out of 14SWG, MS sheet enclosure with 160A, 415Volts, 3 phase,not less than 35kA, TP&N,50 Hz Aluminium busbars, single busbar system, cable chamber,Voltmeter,Ammeter, protection relays, with necessary interconnection, painting, earthing,power factor controlloer,APFC relay etc.comprising of the following, the board shall be fabricated as per the SLD with IP54
Incomer:
160A, 4-pole 36 kA,MCCB, Thermal magnetic type, variable settings ,Rotary handle,Spreader Terminals, etc are required- 1 nos
Outgoings:50kVAR
1 sets of 20 KVAR with 100A,TP, 25kA MCCBs,Cap.Duty Contactors,7% detuned reactor with switching steps in the rating of 20 KVAR as required.
2 sets of 10 KVAR with 63A,TP, 25kA MCCBs,Cap.Duty Contactors,7% detuned reactor with switching steps in the rating of 20 KVAR as required.
2sets of 5 KVAR with 32A,TP, 25kA MCCBs,Cap.Duty Contactors,7% detuned reactor with switching steps in the rating of 10 KVAR as required.
With necessary Aluminium busbars, interconnections, providing Digital Voltmeter,Ammeter , RYB and “ON / OFF / TRIP" indicating lamp at incomer, control PT, CTs, MPCBs and MCB and APFC Relay etc. and all other necessary accessories as per the specification/SLD.Each KVAR capacitor in a separate compartment with necessary ventilation arrangemnts or weld mesh arrangements as required by the Electrical Authorities .
Incomer:
100A,25kA, 3P,Thermal magnetic type, variable settings ,Rotary handle,Spreader Terminals, etc are required-2 nos
Outgoings:
63A, 25kA, 3-pole MCCB, Thermal magnetic type, variable setting ,Rotary handle,Spreader Terminals, etc are required-4 nos
Incomer:
100A, 25kA, 3-pole MCCB, Thermal magnetic type, variable setting ,Rotary handle,Spreader Terminals, etc are required-2 nos
Outgoings:
63A, 25kA, 3-pole MCCB, Thermal magnetic type, variable setting ,Rotary handle,Spreader Terminals, etc are required-4 nos
Tap off box ,MCCB and DB's
MCCBs, MCBs, AND DBs
SITC of 415 volts 400A,4P,50kA, TM, MCCB with variable current settings and terminal spreaders in existing tap off box with complete modification ,connections,testing and commisioning of Tap off box also required
SITC of 415 volts 125A,4P,25kA, TM, MCCB with variable current settings and terminal spreaders in existing MCCB DB including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and fixing of 3P4W MCCB VDB in surface/ recess mounting, vertical type, 415 V, TPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting 4 pole MCCB as incomer and MCB (3 pole) are outgongs. (but without MCBs and incomer ) as required . (But without MCB/RCCB/Isolator)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (But without MCB/RCCB/Isolator)
3P 4W VDB
3P 8W VDB
3P 12W VDB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commisioning.
5A to 32A ,SP MCB
5A to 32A ,DP MCB
5A to 32A ,TP MCB
63A, 3P MCB
63A,4P MCB
MCB Dummy
CABLES
Supply,Laying PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes through existing cable TRAY/RCC/ HUME / GI/ DWC pipe / Concrete trench/Clamping on wall etc. as required.
3.5Cx400 sq.mm XLPE Armoured Aluminium cable.
4Cx95 sq.mm XLPE Armoured Aluminium cable.
4Cx70 sq.mm XLPE Armoured Aluminium cable.
4Cx50 sq.mm XLPE Armoured Aluminium cable.
4Cx25 sqmm XLPE Armoured Aluminium cable.
3Cx25 sqmm XLPE Armoured Aluminium cable.
5Rx1Cx35 sqmm Un-Armoured/Flexible copper cable.
5Rx1Cx16 sqmm Un-Armoured/Flexible copper cable.
Dismantling of existing PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes with out any damage in the existing systems as per the direction of Engineer in Charge
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Laying of existing PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes through existing cable TRAY/RCC/ HUME / GI/ DWC pipe / Concrete trench/Clamping on wall etc. as required.
Upto 35 sq. mm
Above 35 sq. mm and upto 95 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required
3.5Cx400 sq.mm XLPE Aluminium cable.
4Cx95 sq.mm XLPE Aluminium cable.
4Cx70 sq.mm XLPE Aluminium cable.
4Cx50 sq.mm XLPE Aluminium cable.
4Cx25 sqmm XLPE Aluminium cable.
3Cx25 sqmm XLPE Aluminium cable.
Making end termination/connection of following cables in the existing panels,DB,MCCB etc without Glands.
5Rx1Cx35 sqmm Un-Armoured/Flexible copper cable.
5Rx1Cx16 sqmm Un-Armoured/Flexible copper cable.
EARTHING
Supply, laying/fixing of (25x6)mm GI strip for earthing of switchboard and jointing as per IS:3043 / 87 in open trench / walls / pulling through pipes etc as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply, laying/fixing of 10 SWG copper for earthing of switchboard and jointing as per IS:3043 / 87 in open trench / walls / pulling through pipes etc as required.
METERING
Supply and installation of 3-phase TOD meter,class 0.5s with RS 485 communication port in the existing metering panels/box including any modifiaction in the existing panel if requiered
Supply and installation of 3 ph kwh meter Flush Mounted Type(CT operated),Class 0.5 with RS 485 communication port in the existing metering panels /box
Supply and installation of 400/5A,15VA, CL:0.5s cast resin current transformer
Supply and installation of 3 Phase 4 Wire kWh meter 10- 60 A Accuracy class 1 with RS 485 communication port with Meter box confirming to IS14434 suitable for install energy meter with lock and Key arrangement. (For AHU energy meter)
Supply and installation of 3 phase Meter box confirming to IS14434 suitable for install energy meter, CT with lock and Key arrangement. (For main energy meter)
MISCELLANEOUS
Supply and erection of vertical and horizontal type cable trays and cable supports fabricated out of MS angles (ISA) and MS flats with sufficient width and spacing between successive cross members and supported at adequate spacing. The cable trays and supports shall be painted with two coats of Zinc Chromate primer and two coats of enamel paint. (Size as specified by Technopark as per site conditions)
Supply and laying of Polymer mat -2 x 1M -6mm thick( latest Indian standard(IS:15652:2006 )
Supply and providing 5 kg Dry Chemical Powder type FireExtinguisher with hose and clamps including fixing it to wall as required
Dismantling ,reconnecting , modifications of existing DB's, connections, end termination, Cable gland, earthing etc as per the diection of engineer in charge.
WIRING AND LUMINARIES
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for two light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for three light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for Four light point controled with one switch with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supply and fixing of 10W, LED recessed mound round light with pressure dicast aluminium heat sink and PC defuser CRI>=80,PF>=0.95 ,CCT 5700 K Efficacy >=90
Supply and fixing of LED recessed ceiling fixture 600X600mm System power 32/34 W ,CRI >= 80,PF>=0.95, Total lumen 3300-3600 ,CCT 5700K,Efficacy>=105
Supply and fixing of LED hanging downlighter with System power 12/15 W ,CRI >= 80,PF>=0.95 ,CCT 5700K, Rated Voltage 240V,
Supply and fixing of 12V, IP 20 rated, Non-integral flexible LED strip light-5050, along with aluminium profile for mounting. Designed for installation by adhesive back peel for easy installation on the surface/wall including aluminium profile with power consuption not more than 15W/mtr, CRI not less than 80%, color temperature 3000 K . Mounting height is 5m(avg).
Supply and Fixing of LED Drivers for LED strip light ,240V AC/12V, with IP20. Mounting height is 5m(avg). (For mounting, all tools and accessories under the scope of contractor)
Supply and Installation of Independent modular plug point (international type) with 6A 5 pin plug socket controlled by 6A switch with suitable modular plate, GI box/PVC box in recess/ surface .
Supply and installation of combined modular plug point (international type) for 6A, 5 pin plug socket controlled by 6A modular switch in the same switch board with suitable modular plate, GI box/PVC box in recess/ surface.
Supply and Installation of Independent plug point with 16A plug socket (international type) controlled by 16A switch with suitable modular plate ,GI box/PVC box in recess/ surface .
Supplying and fixing 20 A, 240 V, SPN Power Socket, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
3 pin 15/16 A socket outlet
Modular blanking (dummy) plate
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module
3 Module
4 Module
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required
Supplying and drawing following sizes of 1.1kV FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
2Rx1.5sqmm with 1R 1.5sqmm Green wire for earthing
2Rx2.5sqmm with 1R 1.5sqmm Green wire for earthing
2Rx4sqmm with 1Rx2.5sqmm Green wire for earthing
Supplying and fixing of 20mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 32mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 20mm of PVC flexible conduit along with accessories in surface
Dismanteling of existing ceiling fans, CFL fittings, power sockets, network sockets etc. without causing any damages to the existing structure and dumping the dismanteled materials to a suitable loction as instructed by Technopark's Engineer/Supervisor. (The actual numbers of the items to be dismantled shall be finalised by the contractor only after conducting a site visit prior to quoting.)
Preparation of all drawings submitting and getting approval from electrical inspectorate, submitting of Completion certificates and arranging inspection, getting sanction and energization certificate etc, for commissioning of the whole installation in the premises.
TRUNKING
Supply, laying and installation of following trapezoidal point load tested PVC floor ducting supplied including trunk connector, clamp, vertical/ horizontal bend etc in screed floor or on wall in line with EN 50085 including chasing and refilling the trench as per the route shown in the drawing and approved by Technopark at site including clamping & closing the open ends temporarily by suitable end covers against entry of dust or any foriegn materials. Installation rates of PVC trunk should be inclusive of necessary hardware and arrangement required for fixing of trunk with duct connector and fastening clamp. This activity also includes Duct connector, Fastening Clamp alongwith associated accesories.
90 mm wide x 35 mm deep trapezoidal UPVC duct with 2 mm thick
60 mm wide x 25 mm deep trapezoidal UPVC duct with 2 mm thick
358 mm x 358 mm GI under floor box suitable for three run of 90 x 35 mm UPVC Duct entries on all side complete with screeding cover and 358 mm x 358 mm square GI + Powder coated inspection cover complete with load plate colour matched to the floor finish with the RAL colour code confirmed by the architect. The floor boxes need to be supplied with 10 mm floor covering protection flange all around the trap and frame.
260 mm x 260 mm GI under floor box suitable for two runs of 90 x 35 mm UPVC Duct entries on all side complete with screeding cover and 266 mm x 266 mm square GI + Powder coated inspection cover complete with load plate colour matched to the floor finish with the RAL colour code confirmed by the architect.The floor boxes need to be supplied with 10 mm floor covering protection flange all around the trap and frame
Service outlet system for PVC duct , polyamide trap & frame, pre-galvanised screed box (308mm x 308mm) with polystyrene top cover for height adjustment and screed proection; load bearing:3 kN with <6 mm deflection as per EN50085 2-2, Hieght adjustable from (65 mm to 100mm).
NETWORKING
Supplying and drawing of following Cable in the existing surface/ recessed Steel/ PVC conduit as required including I/O terminations and labelling at both ends.
CAT-6, 4 pair, Polyethylene/Polyolefin insulated UTP Twisted Pair Cable Bare with solid copper wire (23/24 AWG)
CAT-6A, 4 pair, Polyethylene/Polyolefin insulated UTP Twisted Pair Cable Bare with solid copper wire (23/24 AWG)
Supply and Fixing of 3P/UL certified, Category 6 Class E, 8-position un-shielded RJ-45 Jack, accepts installation cables AWG 26 – 22; gold-plated bronze IDC contacts with Shutter/Dust Cover
Supply and Fixing of 3P/UL certified, Category 6A Class EA, 8-position un-shielded RJ-45 Jack, accepts installation cables AWG 26 – 22; gold-plated bronze IDC contacts with Shutter/Dust Cover
Supply and fixing of 19" Category 6/6A, umloaded patch panel with 24 ports RJ45, Non-sticky / Removable labelling strips, capacity to accept 24nos of modules to mix and match media types in the same panel i.e UTP / STP / Fiber adapters, Metal patch panel, empty with integrated cable tie shelf/strain relief bars to support and manage cables.
Supply and Installation of UTP, LSFRZH 1 meter Patch Cords with CAT-6 compliant RJ45 connector. Strain-relief function in acc. with TIA TIA/EIA 568.2-D including labelling at both ends.
Supply and Installation of UTP, LSFRZH 2 meter Patch Cords with CAT-6 compliant RJ45 connector. Strain-relief function in acc. with TIA TIA/EIA 568.2-D including labelling at both ends.
Supply and Installation of UTP, LSFRZH 1 meter Patch Cords with CAT-6A compliant RJ45 connector. Gold plated Bronze contacts Strain-relief function in acc. with TIA TIA/EIA 568.2-D. including labelling at both ends.
Supply and Installation of UTP, LSFRZH 2 meter Patch Cords with CAT-6A compliant RJ45 connector. Gold plated Bronze contacts Strain-relief function in acc. with TIA TIA/EIA 568.2-D. including labelling at both ends.
Supply and Fixing of 2 port, shuttered, 86x86mm, flush mounting, white coloured Face plate with labelled windows and excangable label strips.
Supply and Fixing of ISI medium class PVC casing and capping of following diamensions along with accessories through wall in surface/ceiling
Testing of all network cables with Fluke DSX 5000 meter or higher and submission of testing reports to the Technopark, Rack Dressing and other miscellanuous items .
TECHNO ENGINEERING CORPORATION
POWERSKILL ENGINEERING SOLUTIONS PVT LTD
Shine Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .