Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.4 L+₹2.6 L (7.13%)Rejected-Finance 234 4 JC BOSE ROAD KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹42.9 L+₹6.2 L (16.8%)Rejected-Finance KHUDIRAMPALLY P O BANARHAT DISTT JALPAIGURI W B PIN 735202 | JALPAIGURI | WEST BENGAL | 735202 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹43.3 L+₹6.6 L (17.9%)Rejected-Finance GARRISON ENGINEER GE NORTH BINNAGURI | JALPAIGURI | WEST BENGAL | 735232 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹43.7 L+₹7.0 L (18.9%)Rejected-Finance GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
30 Sept 2020, 6:00 pmClosed
Cwe Binnaguri
HQ CWE BINNAGURI
SPECIAL REPAIR TO BUILDING NO P-22 P-62 AND ROOF TREATMENT OF CERTAIN BLDG AT BINNAGURI MIL STN UNDER GE NORTH BINNAGURI
2020_MES_371324_2
8010/BIN(N) 26 of 2020-21
Open Tender
Civil Works
Item Rate
120 days
Binnaguri Mil Stn
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE NORTH BINNAGURI
₹1.1 L
Yes
4 Dec 2020
17 Sept 2020
1 Oct 2020
17 Sept 2020
30 Sept 2020
18 Sept 2020
Amount
Schedule 'A'
Demolition of reinforced cement concrete of any description and in any position all as spd and directed including removal of debris out of MOD land complete all as specified and as directed. (Upto 4th story bldg)
Demolition of Mud in roofs, any thickness, including pcc tiles, plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed.
M and L for PCC 1:2:4 type B-0, (using 12.5mm graded aggregate) in roof kerbs, padding concrete over roof or mud stops, rounded or chamfered on edges complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP base polymeric membrane, finished even and smooth without using extra cement complete all as specified and as directed.(Note: Polymeric membrane shall be measured and paid separately under relevant item of this schedule A)
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment/specification from bottom to top :- (a) Applying bituminous primer @ 0.4 ltrs per Sqm over plastered surfaces of roof incl parapet surface. (Note :- Bituminous primer shall be "TANK MASTIC" manufactured by "EMUFALTE" manufactured by M/s Texsa India Ltd. or equivalent ) (b) Over the priming coat laying one layer APP based polymembric membrane of approved manufacturer 3mm thick weight not less than 3.6 Kgs per Sqm reinforced with non woven polyester febric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP based polymeric membrane shall be done torch on method or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) APP based polymeric membrane shall be "MOPLY FP 3MM" manufactured by M/S Texsa India Limited or equivalent. (iv) Applying two coats of Aluminium paint over APP membrane.)
Taking down cement plaster on wall of any description incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work mixed with water proofing compound in top layer @ 3% by the weight of cement or as per manufacture's instructions finishing the surface fair and even without using extra cement complete all as specified and as directed. (Note:- Water proofing compound shall be measured and paid separately under relevant item of this schedule 'A')
Supply only integral water proofing compound conforming to IS : 2645-1975 specifications. Complete all as specified and as directed.
M&L for rendering 15mm thick plastering in CM (1:6) for finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in CM 1:3 as in ceiling and fair finished without using extra cement complete all as specified and as directed.
M&L for preparing of new surfaces of walls and applying two coat of cement base paint over a coat of alkali resistant primer complete as specified and directed.
M&L for preparing of new surfaces of walls and applying two coats of oil emulsion distempering including 1mm thick wall putty all complete as specified and directed.
M&L for applying three coats of white washing on new plastered wall surfaces including preparation complete all as specified and as directed.
M&L for applying three coats of white washing on new plastered surfaces of ceiling including preparation complete all as specified and as directed.
M&L for complete removal of existing treatment on old surfaces of walls and applying two coat of oil emulsion distempering including applying 1mm thick wall putty before application of distempering all complete as specified and directed.
M&L for complete removal of existing treatment and applying two coat of cement base paint over a coat of alkali resistant primer complete as specified and directed.
M&L for complete removal of existing treatment and applying three coat of white wash on old wall surfaces complete as specified and directed.
All as per item No 17.00 here-in-above item but in ceiling surfaces complete all as specified and as directed.
Taking down chowkats of frames with shutter not exc1.50 sqm each of any description any type complete all as specified and as directed.
S&F steel window with side hung shutter including projecting hinge, fixing lugs, steel handle and steel peg stay, complete with or without glazing bars and for gauged shutter dovetailed or welded complete all as specified and as directed
Hacking out old unserviceable glass panes from metal framing including punching drilling out old unserviceable glazing pins complete all as specified and as directed.
M&L for 3mm thick plain glass, ordinary quality and glazing with oil putty in square n exc 0.5sq. m in each pane complete all as specified and as directed.
Taking down chowkats of frames with shutter exceeding 1.50 sqm and not exceeding 4 sqm each of any description any type complete all as specified and as directed.
S&F of pressed steel framed for door with one or more rebates including necessary fixing lugs, hinges, lock strike plates, size of frame 125 X 60 mm, including finishes of disterub surfaces of wall complete all as specified and as directed.
S&F of pressed steel framed for door with one or more rebates including necessary fixing lugs, hinges, lock strike plates, size of frame 105 X 60 mm, including finishes of disturb surfaces of wall complete all as specified and as directed.
M and L for Cutting holes superficial area exc 150 Sqcm and n.exc 400 Sqcm into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1 with using 20mm graded stone aggregate as in bed blocks, coping, for fixing holdfast/lugs, filling hollow space of pressed steel door frame etc including necessary form work all complete as specified and as directed.
S&F of 35mm thick 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rails and panel of 9mm BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 Part-I klin seasoned and chemically pressure treated complete all as specified and as directed.
S&F for factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc, size of members of shutter as specified in SSR Part-I section 8 clause No.8.23(a) and fitted to chowkats complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and as directed.
S&F in repairs Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and as directed.
S&F MS sliding door bolts 250 mm long size plate type stove enamelled black with bright bolt not less than 12mm dia with and including minimum of 6 nuts and bolts, four on bolts plate and two on staple plate complete all as specified and as directed
S&F aluminium anodised barrel tower bolts of extruded section 200mm long complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
S&F aluminium handles 150mm size cast type anodised complete all as specified and as directed.
S and F Butt hinges 100mm size , medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.
M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of zinc chrome primer complete all as specified and as directed.
M&L for preparation of old or previously treated wooden surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old or previously treated steel surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolition of brick work built in cement mortar and removing from site complete all as specified and as directed.
M&L brick work with sub class B bricks straight or curved on plan exc 6 meter mean radius built in cement mortor 1:6 complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) as in floor complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layer in CM (1:4) as in vertical surfaces of skirting dados , steps complete all as specified and directed incl taking down plaster complete all as specified and as directed.
M & L 20mm thick Screed bed or beding layer of mortar of (1:6 for laying in floor finishes to receive kota stone complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 15-20mm thick over 15 mm cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete in riser of steps, skirting and pillar are specified as directed
Do as above but in vertical surface such as steps, skirting, risers, pillars etc. complete all as specified and as directed.
M&L for Non skid ceramic colored tiles of size 400 x 400 x 7 to 8mm thick as in floor set & jointed in neat grey cement slurry & pointed in coloured cement to match with the tiles complete all as specified and as directed.
All as per item No 49.00 here-in-above item but in skirting/dado complete all as specified and as directed.
Dismantling of mild steel or wrought iron of any description complete all as specified and as directed.
M and L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290 complete all as specified and as directed.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
S&F harrison rail/curtain rod, mild steel chromium plated with fixing bracket, stops and complete fitment all as specified and as directed.
Demolition of cement concrete in ground floor and pavings n.exc 15cm thickness (below or above ground level) including removal of debris/demolished materials to a distance exc 50m and n.exc 250 m as directed by Engr-in-Charge complete all as specified and as directed.
M&L for 75mm thick PCC type C-2 , 1:3:6 (40mm graded stone aggregate) as in plinth protection/ foot path finished even and fair without using extra cement complete all as specified and as directed.
M and L for Cement concrete1:3:6 Type C-1 using 20mm graded aggregate as in surface channels and drains complete allas specified and as directed.
M and L for 40mm thick PCC 1:2:4 type B-0, (using 12.5mm graded aggregate) as in flooring including finishing even and smooth with using extra cement complete all as specified and as directed.
S & F 150 mm long Mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and as directed.
S & F 150 mm long Mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed.
S&F in repair steel window with side hung shutters incl. projecting type hinges with steel handles steel peg stay fixing lugs complete with glazing bar 10 cm devetailed or welded incl shop coat red oxide primer compete all as specified and as directed.
All as per item No 61.00 here-in-before but without glazing bar complete all as specified and as directed.
M&L for for preparation of newly wall plastered surfaces and applying two coats of oil bound distemper on wall complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint complete all as specified and as directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L RCC type B1 (1:2:4) using 20 mm graded aggregate in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and as directed.
Formwork to fins, louvers, fascia. etc Fair finished surfaces of concrete flat complete all as specified and as directed.
M&L Mild steel TMT bars 6mm to 8mm dia,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
M&L for 25mm thick pre-polished and chemically treated smooth finish exterior grade coloured chequered tile as in path all as complete and as specified and directed.
M&L for one coat of cement base paint on wall of old surface with preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
M&L for one coat of white wash on ceiling of old surface with preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
M&L for one coat of oil emulsion distemper with preparation of old surface shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed .
Taking down carefully old/unsv copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan regulators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and directed.
M&L for Concealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core malti stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification) including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :- One light point controlled by one way switch 5/6 amps complete all as specified and as directed.
One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps complete all as specified and as directed.
One socket out let 5/6 amps point on the independent board complete all as specified and as directed.
One socket out let 5/6 amps point on the same board complete all as specified and as directed.
All as per item No 75.00 here-in-above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 6 pin 5/6 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable, complete all as specified and directed.
S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S & F in repair lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F in replacement of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 double side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to ceiling rose complete all as specified and directed.
Supply and fixing bldg security light fitting luminaire with high power LED and unique peanut lens to ensure uniform light distribution ,higher spacing between poles and maintence free system of not less than 45 Watts IP 66 type incl standard fittings pressure die cast aluminium housing with heat reistant toughened glass with epoxy powder coated finish complete with Electronic driver, Surge protector not less than 5 KV and all accessories duly prewired complete all as specified and as directed.
M & L for street light bracket made out of GI pipe light grade 32 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.5m length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and as directed.
M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed.(NOTE : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’. (ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length).complete all as specified and as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/isolators complete with and including taking down old unsv one all as specified and directed.
S&F MCB, Single pole & neutral,5 to 32 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed.
S&F MCB, Single pole & neutral, 35 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
S & F in repair deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F LED white glass Lamp 1 x 9/10 Watt 230V Base-22 complete all as specified and directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed. NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
Disconnecting and removing U/S building security light fitting of any type from bldg and Supply and fixing new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP 66 protection and impact resistance of IK07system of not less than 25 Watts IP 66 type incl standard fittings pressure die cast aluminium housing, heat resistant toughened glass, epoxy powder coated finish complete with Electronic driver, Surge protector not less than 5 KV and all accessories duly prewired complete all as specified and directed.
Taking out old unserviceable cable of any size carefully from trenches after disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note : The Excavation and earth work shall be measured and paid separately under relevant item of Schedule.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 16 sqmm 2 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A' complete all as specified and as directed.
M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
M/S SARKAR BROTHERS
S. G. CONSTRUCTION
Shri Amarnath Sah
ANIL ENGINEERING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .