GENERAL MANAGER (MATERIALS AND CONTRACTS)
Indian Oil Corporation Limited, Western Region Pipelines, P.O. Bedipara, Morbi Road, Gauridad, Distt. Rajkot-360 003 (Gujarat)
SITC of LHS cable based rim seal fire detection system with SITC of 600L SS-316 foam tank including accessories for automation of existing foam pourer system in 250KL transmix tank at WRPL Sidhpur
2021_WRRAJ_131510_1
PWRJT20059
Open Tender
Instrumentation - All
Works
120 days
WRPL Sidhpur
Please refer Tender documents.
15 documents required · 15 mandatory
Exempted
20 Mar 2021
11 Feb 2021
12 Mar 2021
11 Feb 2021
10 Mar 2021
19 Feb 2021
Amount
Supply of two wired Linear Heat Sensing and detection Cable with Nylon outer sheath & Nylon braiding (35 Mtr x 2 lengths) including glanding, cable termination ,earthing, structure support etc. Note:- Additional spare Linear Heat sensing cable of length suitable for installation on the tank shall be supplied by the Vender, at no extra cost).
FLP & WP JUNCTION BOX:- Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable termination , including connection and termination of earthing wire and conduits etc. including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect. {FP multiway Junction Box with terminal blocks and fittings) Ex proof Junction Box (Zone-1 with PESO or equivalent Certification) for installation at landing platform WITH cable entry nos. and size and as per the the site requirement}
FLP & WP JUNCTION BOX:- Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable termination , including connection and termination of earthing wire and conduits etc. including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect. {FP multiway Junction Box with terminal blocks and fittings) Ex proof Junction Box (Zone-1 with PESO or equivalent Certification) for installation at floating roof. cable entry nos. and size and as per the the site requirement}
Installation ,Testing & Commissioning of two wired based linear heat sensing cable including supply and installation of all materials for making the system operational, laying of cables (12 Core x 1.5 Sq mm FRLS armoured control cable & 3 Core x 2.5 Sq mm FRLS armoured Power Cable) in underground buried cable trench as per drawings, dressing of cable, cable gland termination etc, in all respect for complete functioning of Linear heat sensing system including the submission of As built drawings.
Supply of Miscellaneous Items for LHS Cable:-Supply of all materails required for installation, testing and commission two wired linear heat sensing system as per the technical specifications like: - Barrier (2 No’s) ,100mm GI cable tray with cover (100 M length), Flame proof and weather proof Local Control Panel including supply of EP/WP double compression cable glands, plugs for unused cable entries including EP/WP certificates as per the tender specifications. (FP multiway Junction Box with terminal blocks and fittings) With Relay contacts for JB at Tank Dyke (1 No’s) , Earthing strips , modules, 230VAC-24VDC or converter suitable for operation of solenoid valve, field Alarm and annunciation panel with testing arrangement beacon/hooter complete in all respect for complete functioning of Linear heat sensing system
12 Core x 1.5 Sq mm, CU, FRLS armoured control cable from Foam Dam JB to Dyke wall and Dyke wall to Control room (CONTROL CABLE, Conductor material: Copper, Insulation material: PVC, Core: Multicore, Voltage :660/ 1100V, Standard designation: IS 1554.) 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%
3 Core x 2.5 Sq mm, CU, FRLS armoured Power Cable from Foam Dam JB to Dyke Wall JB and from Dyke wall JB to control Room (1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%)
4 Core x 4 Sq mm, CU, FRLS armoured Power Cable for instruments of Deluge Valve (1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density<40%)
Supply of Miscellaneous Items for Foam Tank Installation:-Supply of Miscellaneous Items for Foam Tank Installation:-Supply of 600L, SS-316 Foam Tank as per drawing and specifications including all the auxiliaries required for installation, testing, commissioning and auto operation of foam pourer system such as A) 3 % AFFF Foam Concentrate (600L) B) Deluge valve with electric trim solenoid valve, pressure switch, motor gong, valve etc. C) 270 LPM Inline inductor (01 No’s), D) 80NB Gate Valve (3 No’s), E) 80Nb Y Type strainer (1 No’s), F) 25NB Ball valve for drain connection (2 No’s) G) Pressure switch with isolation valve (1 No’s) H) Pressure gauge with isolation valve (1 No’s) I) Manual Release unit (1 No’s), J) 80 NB MS Heavy C-class Piping & Fittings (6 Metres), K) 80 NBGI Piping & Fittings (6 Metres) L) 15 NB SS-316 piping & Fittings (6 Metres) M) SOV for deluge valve and foam line N) Providing Pipe supports as per requirement. Etc. or any other items as per requirement of the work.
Installation ,Testing & Commissioning of 600L SS-316 and all other accessories and making auto operation of existing foam pourers through solenoid operated deluge valve including all the materials, manpower, tools & tackles required in interest of the work and making system operational, laying, dressing and terminal of cables (4 Core x 4 Sq mm FRLS armoured Power Cable) with cable glands including construction of Foundation support for Tank and its accessories submission of As built drawings.
Foam Dam:- Fabrication and Erection of GI Foam Dam as per requirement in 250 KL Transmix Tank having 8.0 M Dia including all the materials required for installation, tool & tackle and manpower.
Supply of ASTM A106 Gr.B /A333 pipes at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document. 4.500" ODx 0.237" WT (Sch.STD) ASTM A 106 Gr B bare Pipe _I.2
Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document -FOR FIRE WATER NETWORK: 4"x ANSI 150# HOV F/F API 600 Gate Valve FW _O.19
Supply and delivery of Steel Fasteners at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document. Fasteners for Flanges 4" x 150# (0.625" Dia. X 4.00" Length ) _B.11
Supply and delivery of Steel Flanges at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document: 4", WNRF FLANGE, ANSI - 150# (B 16.5)_C.12
Supply and delivery of Spiral Wound Metallic Gaskets at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document: 4" SWMG ANSI 150#_A.11
Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document: 4" ANSI 150# Equal Tee_E.87
Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document: 4" ANSI 150# 90 deg LR Bends_E.130
Above ground internal epoxy coated pipe for Fire Water Services: (with internal epoxy coating for repair at wending joints ) Taking delivery of internal epoxy coated pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air, hydrostatic testing of each section to the specified pressure, draining the water, tie-in, final cleaning-up and disposal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract).The scope shall also include cleaning of internal surface of pipes conforming to SSPC SP-10 at all location where coating has been distroyed due to welding and repairing the internal surface by application of 2-pack cold cured Isophthalic polyster acrylic co-polymer glass flake filled /Liquid epoxy / Equivalent with coating of thickness 700-1000 Microns . The locations where internal coating repair is expected would be at pipe end, Flanges ,pipe fittings ,valve location so that the internal of pipe surface is not directly exposed to water and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. 4.5" ODx 0.237" WT ASTM A 106 Gr B Pipe FW_E9
Installation of Valves(for Fire water Lines-Tanks & Piping) : Taking delivery of valves of all types and pressure rating from thedesignated location within station premises, transporting the same tosite, erecting above ground on preconstructed foundations or undergroundincluding earth work in excavation and filling for under ground valvesat elevations specified in the drawings, priming and painting of aboveground valves, flood coating and wrapping of under ground portions (ifapplicable) including all inputs, labour, material and consumable (otherthan those specifically undertaken to be supplied by the owner) andcompleting the work in all respects in accordance with the drawings,manufacturer's installation instructions and specifications andinstructions of the Site Engineer /EIC. Note:The cost of construction of Valve foundations shall be measured &paid separately under respective civil items. " 4"x ANSI 150 # HOV F/F API 600 Gate Valve FW_K11
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .