| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹30.9 L | L1 | Accepted-Finance L1 |
| 2 | L2₹32.9 L+₹2.1 L (6.66%)Rejected-Finance A 17 1ST FLOOR TRIBENI COMMERCIAL COMPLEX G S ROAD ULUBARI KAMRUP ASSAM 781007 | KAMRUP METRO | ASSAM | 781007 | ₹32.9 L+₹2.1 L (6.66%) | L2 | Rejected-Finance L2 |
| 3 | L3₹34.3 L+₹3.4 L (11.0%)Rejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹34.3 L+₹3.4 L (11.0%) | L3 | Rejected-Finance L3 |
| 4 | L4₹34.3 L+₹3.4 L (11.1%)Rejected-Finance 63 SECTOR 4 R FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹34.3 L+₹3.4 L (11.1%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not eligible for opening of price bid |
| Sl No | Description | Qty | Unit | D.D.METAL CORPORATION L2 | BR Power Control and Automation Services L4 | ECS ENGINEERING PVT LTD L1 | Awasthi Electric Works L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of PTTA double door outdoor feeder pillar, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, free standing, floor mounting, dust and vermin proof with canopy type cover, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbar including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the Panel and as per specifications shall be equipped with surge protection device type-2.
i) INCOMER: 320 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with extended rotary handle and all accessories (Icu=Ics, 36 KA). = 2 No.with mechanical/electrical interlocking.
ii) BUSBARS: 400 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. = 1 Set.
iii) OUTGOING:
(a) 250 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(b) 160 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(c) 100 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 3 Nos.
(d) 63 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(e) 40 A, Two Pole, DP Isolator = 3 Nos.
iv) INSTRUMENTS: 1 sets digital voltmeter for 3 phase, 4 wire operation with inbuilt selector switches along with 3 No. control MCB's., 1 sets digital ammeter of suitable range (measure 0 to 300 Amp) for 3 phase, 4 wire operation with inbuilt selector switches and 3 No. suitable range CT's., 1 Set of phase indicating lamps, LED type, RYB for Incomer and ON-OFF indicator for Incomer.
(LOCATION: Engg. Civil Office & AAI Residential Main Feeder Pillar) | 1 | Job | 4,40,000 ₹4,40,000 Lowest | 4,86,829 ₹4,86,829 | 5,00,000 ₹5,00,000 | 5,92,000 ₹5,92,000 |
| 2.00 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of PTTA double door outdoor feeder pillar, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, free standing, floor mounting, dust and vermin proof with canopy type cover, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbar including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the Panel and as per specifications shall be equipped with surge protection device type-2.
i) INCOMER: 250 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with extended rotary handle and all accessories (Icu=Ics, 36 KA). = 1 No.
ii) BUSBARS: 300 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. = 1 Set.
iii) OUTGOING:
(a) 100 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(b) 63 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(c) 40 A, Two Pole, DP Isolator = 6 Nos.
iv) INSTRUMENTS: 1 sets digital voltmeter for 3 phase, 4 wire operation with inbuilt selector switches along with 3 No. control MCB's., 1 sets digital ammeter of suitable range (measure 0 to 300 Amp) for 3 phase, 4 wire operation with inbuilt selector switches and 3 No. suitable range CT's., 1 Set of phase indicating lamps, LED type, RYB for Incomer and ON-OFF indicator for Incomer.
(LOCATION: AAI Residential Colony Sub Main-I Feeder Pillar) | 2 | Job | 1,80,000 ₹3,60,000 Lowest | 2,24,408 ₹4,48,816 | 2,40,000 ₹4,80,000 | 2,45,000 ₹4,90,000 |
| 3.00 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of PTTA double door outdoor feeder pillar, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, free standing, floor mounting, dust and vermin proof with canopy type cover, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbar including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the Panel and as per specifications shall be equipped with surge protection device type-2.
i) INCOMER: 160 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with extended rotary handle and all accessories (Icu=Ics, 36 KA). = 1 No.
ii) BUSBARS: 200 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. = 1 Set.
iii) OUTGOING:
(a) 100 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(b) 63 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(c) 40 A, Two Pole, DP Isolator = 6 Nos.
iv) INSTRUMENTS: 1 sets digital voltmeter for 3 phase, 4 wire operation with inbuilt selector switches along with 3 No. control MCB's., 1 sets digital ammeter of suitable range (measure 0 to 300 Amp) for 3 phase, 4 wire operation with inbuilt selector switches and 3 No. suitable range CT's., 1 Set of phase indicating lamps, LED type, RYB for Incomer and ON-OFF indicator for Incomer.
(LOCATION: CISF Barrack & CISF Family Qtr, AAI Residential APD Quarter Block & AAI Residential Colony Sub Main-II Feeder Pillar) | 3 | Job | 1,70,000 ₹5,10,000 Lowest | 2,14,210 ₹6,42,630 | 1,95,000 ₹5,85,000 | 2,27,000 ₹6,81,000 |
| 4.00 | Supply of 1250 A ACB, 4 Pole, 50KA, Model SR18G Protection LSIGN C-POWER S1 Draw-Out ACBs will have inbuilt 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating error preventor. Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging complete as required.
(MAKE: L&T or Equivalent) | 1 | Each | 2,71,000 ₹2,71,000 | 2,34,720 ₹2,34,720 | 1,43,400 ₹1,43,400 Lowest | 1,95,000 ₹1,95,000 |
| 5.00 | Supply of Shunt Release (SR) Type EA1 : 415V AC for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | 3,000 ₹6,000 | 3,487 ₹6,974 | 1,900 ₹3,800 Lowest | 2,500 ₹5,000 |
| 6.00 | Supply of Under Voltage Release (UVR) Type MV : 415V AC for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | 4,700 ₹9,400 | 4,900 ₹9,800 | 3,200 ₹6,400 Lowest | 4,000 ₹8,000 |
| 7.00 | Supply of Microswitch for Common Indication of O/L & S/C (3) each for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | 4,700 ₹9,400 | 4,793 ₹9,586 | 1,800 ₹3,600 Lowest | 35,000 ₹70,000 |
| 8.00 | Supply of Spring charging Motor 240V AC for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | 48,000 ₹96,000 | 15,000 ₹30,000 | 24,000 ₹48,000 | 3,500 ₹7,000 Lowest |
| 9.00 | Supply of Motor Limit Switch for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | 2,000 ₹4,000 | 6,124 ₹12,248 | 1,900 ₹3,800 Lowest | 3,500 ₹7,000 |
| 10.00 | Supply of Hardware kit for Motor for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | 2,600 ₹5,200 | 20,864 ₹41,728 | 2,000 ₹4,000 Lowest | 35,000 ₹70,000 |
Tender Value
₹40.6 L
EMD Value
₹1.2 L
Closing Date
18 May 2026, 3:00 pmClosed
Asst. General Manager (Engg-E)
AAI, Silchar Airport
Replacement of outdoor feeder pillar at different location at Silchar Airport
2026_AAI_275893_1
AAI/SIL/ENGG-E/FEEDER PILLAR/2026-27
Open Tender
Electrical Works
Works
90 days
AAI, Silchar Airport
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹1.2 L
4 Aug 2026
27 Apr 2026
19 May 2026
28 Apr 2026
18 May 2026
28 Apr 2026
28 Apr 2026 - 4 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of PTTA double door outdoor feeder pillar, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, free standing, floor mounting, dust and vermin proof with canopy type cover, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbar including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the Panel and as per specifications shall be equipped with surge protection device type-2.
i) INCOMER: 320 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with extended rotary handle and all accessories (Icu=Ics, 36 KA). = 2 No.with mechanical/electrical interlocking.
ii) BUSBARS: 400 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. = 1 Set.
iii) OUTGOING:
(a) 250 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(b) 160 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(c) 100 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 3 Nos.
(d) 63 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(e) 40 A, Two Pole, DP Isolator = 3 Nos.
iv) INSTRUMENTS: 1 sets digital voltmeter for 3 phase, 4 wire operation with inbuilt selector switches along with 3 No. control MCB's., 1 sets digital ammeter of suitable range (measure 0 to 300 Amp) for 3 phase, 4 wire operation with inbuilt selector switches and 3 No. suitable range CT's., 1 Set of phase indicating lamps, LED type, RYB for Incomer and ON-OFF indicator for Incomer.
(LOCATION: Engg. Civil Office & AAI Residential Main Feeder Pillar) | 1 | Job | - | - |
| 2 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of PTTA double door outdoor feeder pillar, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, free standing, floor mounting, dust and vermin proof with canopy type cover, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbar including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the Panel and as per specifications shall be equipped with surge protection device type-2.
i) INCOMER: 250 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with extended rotary handle and all accessories (Icu=Ics, 36 KA). = 1 No.
ii) BUSBARS: 300 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. = 1 Set.
iii) OUTGOING:
(a) 100 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(b) 63 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(c) 40 A, Two Pole, DP Isolator = 6 Nos.
iv) INSTRUMENTS: 1 sets digital voltmeter for 3 phase, 4 wire operation with inbuilt selector switches along with 3 No. control MCB's., 1 sets digital ammeter of suitable range (measure 0 to 300 Amp) for 3 phase, 4 wire operation with inbuilt selector switches and 3 No. suitable range CT's., 1 Set of phase indicating lamps, LED type, RYB for Incomer and ON-OFF indicator for Incomer.
(LOCATION: AAI Residential Colony Sub Main-I Feeder Pillar) | 2 | Job | - | - |
| 3 | Design, Manufacturing, Supply, Installation, Testing & Commissioning of PTTA double door outdoor feeder pillar, cubicle type, made out of 2mm thick CRCA sheet, totally enclosed, IP 65, free standing, floor mounting, dust and vermin proof with canopy type cover, compartmentalized, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbar including internal wiring with suitable size wires/cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories in the Panel and as per specifications shall be equipped with surge protection device type-2.
i) INCOMER: 160 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with extended rotary handle and all accessories (Icu=Ics, 36 KA). = 1 No.
ii) BUSBARS: 200 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. = 1 Set.
iii) OUTGOING:
(a) 100 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(b) 63 A, Four pole, Thermal Magnetic release variable range Moulded Case Circuit Breaker with Operating handle (36 kA) = 2 Nos.
(c) 40 A, Two Pole, DP Isolator = 6 Nos.
iv) INSTRUMENTS: 1 sets digital voltmeter for 3 phase, 4 wire operation with inbuilt selector switches along with 3 No. control MCB's., 1 sets digital ammeter of suitable range (measure 0 to 300 Amp) for 3 phase, 4 wire operation with inbuilt selector switches and 3 No. suitable range CT's., 1 Set of phase indicating lamps, LED type, RYB for Incomer and ON-OFF indicator for Incomer.
(LOCATION: CISF Barrack & CISF Family Qtr, AAI Residential APD Quarter Block & AAI Residential Colony Sub Main-II Feeder Pillar) | 3 | Job | - | - |
| 4 | Supply of 1250 A ACB, 4 Pole, 50KA, Model SR18G Protection LSIGN C-POWER S1 Draw-Out ACBs will have inbuilt 6NO+6NC Aux contact for EDO breakers, Safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating error preventor. Electrical version includes 240V AC Shunt trip coil, Closing coil and Motor for electrical charging complete as required.
(MAKE: L&T or Equivalent) | 1 | Each | - | - |
| 5 | Supply of Shunt Release (SR) Type EA1 : 415V AC for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | - | - |
| 6 | Supply of Under Voltage Release (UVR) Type MV : 415V AC for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | - | - |
| 7 | Supply of Microswitch for Common Indication of O/L & S/C (3) each for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | - | - |
| 8 | Supply of Spring charging Motor 240V AC for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | - | - |
| 9 | Supply of Motor Limit Switch for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | - | - |
| 10 | Supply of Hardware kit for Motor for 800 A, 3 Pole ACB complete as required.
(MAKE: L&T or Equivalent) | 2 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.21 MB
TD.pdf
Tender Documents • 9.02 MB
BOQ_322239.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .