| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | ₹27.7 L Quoted ₹28.0 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹30.2 L+₹2.1 L (7.60%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | ₹30.2 L+₹2.1 L (7.60%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹30.6 L+₹2.6 L (9.30%)Rejected-AOC | ₹30.6 L+₹2.6 L (9.30%) | L3 | Rejected-AOC REJECTED |
| 4 | L4₹32.5 L+₹4.5 L (15.9%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | ₹32.5 L+₹4.5 L (15.9%) | L4 | Rejected-AOC REJECTED |
| 5 | L5₹34.7 L+₹6.6 L (23.7%)Rejected-AOC | ₹34.7 L+₹6.6 L (23.7%) | L5 | Rejected-AOC REJECTED |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
9 Jun 2020, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVN OF SOLAR LED LIGHT, PROVN OF LED FITTINGS AND FIXTURES IN MD ACCN AND PROVN OF MODULAR SWITCHES AND FALSE CEILING LIGHTS AT ICGS VADINAR AND PROVN OF SOLAR STREET LIGHT AT CGDHQ NO. 1 UNDER GE(I) CG PORBANDAR
2020_MES_320708_2
8481/19-20
Open Tender
Civil Works
Item Rate
180 days
ICGS VADINAR, CHGDHQ NO 01
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I CG Porbandar
₹89,000
Yes
4 Aug 2020
25 May 2020
10 Jun 2020
25 May 2020
9 Jun 2020
4 Jun 2020
Amount
SCHEDULE 'A'
Supply, install and test All in One Integrated Solar LED Street light with PIR Sensor IP-65 protection, compact design, extruded aluminium / Die cast housing, comprising of of LED Luminaire having Output >4500 Lumen with monocrystalline silicon panel and high efficacy >120 lm/Watt,compatible with smart phone Bluetooth enabled mobile app for checking and conrolling street light operations as per user needs, with timer based dimmer feature, mounted on hot dip galvanised octagonal pole complete, all as specified and directed by Engr-in-Charge. INTEGRTATED SOLAR LIGHT (I) Solar Panel: Mono crystalline panel, peak wattage not less than 60 Watt (ii) Charge Controller type :- MPPT dimmable with intelligent control module / sensor . (iii)Battery :- Lithium Ferro Phosphate battery (LiFePo4) Ah as per Manufcturere's design with two days of backup, 12.8V. Make : Wipro/ Philips/ ORIENT / OSRAM / SCHNEIDER / SURYA Location and Quantity: VADINAR - 16 No/ PORBANDAR-13 No Note: The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied.
Supply and install Octagonal hot dip galvanised iron pole, 6m long with base plate, 300mm long weather proof reinforced door opening with junction box mounting arrangement, inbuilt junction box, 'J' shape, EN8 foundation bolt with nuts template including RCC foundation as per manuacturer's design conforming to IS 1786. The foundation shall extend above surrounding levels by 200mm all as directed by Engineer-in-charge. Make :Wipro/ Surya/ Crompton Greaves/ Bajaj / Utkarsh NOTE :The contractor should submit manufacturer's foundation drawing before commencement of foundation work. Excavation/earthwork, removal and returning filling included in the quoted rate. Location: DHQ No. 1 Porbandar / Vadinar
M&L Point wiring complete with 1.5 sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I, ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall / On surface of roof ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets, fan regulators with required modules complete all as specified and as directed by Engineer-in-Charge. for the following:- Note: Cost of cutting / chasing on wall and making good after repair shall be measured and paid seperately. Make of cable: Havells/ Finolex/ RR Kable/ KEI
One light /fan point / bell point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
Material and Labour for Point wiring complete with 2.5 sqmm single core PVCinsulated but unsheathed multistranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessedin wall / On surface of roof ceiling etc including 2.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame for modular switches, sockets,switch sockets for one 3 pin 15 or 16 Amps on independent board with required modules complete all as specified and as directed by Engineer-in-Charge. Note: Cost of cutting / chasing on wall and making good after repair shall be measured and paid seperately. Make of cable: Havells/ Finolex/ RR Kable/ KEI
S&F Modular switch 1 way, 6 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular switch 1 way, 16 Amps, 1 module complete all as specified and as directed by Engineer-in-Charge.Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular socket, 6 Amps, 2/3 pin combined 2 module complete all as specified and as directed by Engineer-in-Charge. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
S&F Modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified and as directed. Make: Legend (Arteour) / Schneider (zencelo) / hager (berker)
M&L for sub main wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 6.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
M&L for sub main wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS 1100 Volts grade cable fire retardant low smoke drawn through ad including PVC concealed conduit heavy duty grade ISI marked 25mm dia external but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 4.0 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire fixed on wall/ceiling complete all as specified and directed. Note: Cost of cutting / chasing on wall and making good after repair shall be deemed to be included in quoted rate . Make of cable: Havells/ HPL/ RR Kable/ KEI / L&T
S&F 20W Surface/Wall mounted Batten LED Luminaire, extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life LED chips, CRI=80(Minimum) PF>0.95, System luminous efficiency >100 lm/Watt, Operating voltage 150V-270V including electrical connection with 3 Core flexible cable of appropriate size from ceiling rose to LED fitting complete all as specified and directed, fixed in repairs Make : Wipro Trim LED (LL20-281-XXX-65AL1/Philips (BN021C LED 20S PSU CW GR S2) or OSRAM (LUXPOWER Batten)/ Orient (LBLN-20-C-AL) Note: The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied.
S&F 10W Surface/Wall mounted Batten LED Luminaire, Co-extruded channel in thernally conductive material with plastic housing, and integrated electronic driver with high efficiency long life LED chips, CRI=80(Minimum) PF>0.95, System luminous efficiency >90 lm/Watt, Operating voltage 150V-270V including electrical connection with 3 Core flexible cable of appropriate size from ceiling rose to LED fitting complete all as specified and directed, fixed in repairs Make : Wipro Trim LED (LL20-111-XXX-65 NE)/Philips (BN021 LED 10S-6500 PSU GR S1) or OSRAM(LEDCOMFO Batten)/ Orient (LBLN-10-C-AL) Note: The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied.
S&F LED Luminaire surface mounted down lighter of capacity 12 Watt. system efficiency not less than or equal to 100lm/watt, THD <20% single phase including connecting cable from ceiling rose to terminal block of luminaire complete all as specified and as directed by Engineer-in-Charge, in repairs. Make : Wipro (LD80-101-XXX-60-SM) / Philips (SM 250C-LED-12S-6500-PSU-WH)/ ORIENT (LDSER-12-C) Note : Cost of cutting and fixing in existing false ceiling deemed to be included in quoted rate.The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied.
S&F 9W Recessed mounted round shape LED downlight with minimum efficiency 100 lumen/Watt, THD<10%, HET diffuser, high quality Die cast aluminium housing, input voltage 220-240V,CCT 5700K, input frequency 50Hz including electric connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to fixture complete all as specified and directed, Make :Wipro (CRDL11R013HP57) /Philips (DN 392B LED 10S-6500-PSU-WH) / ORIENT (LDRND-10-C) Note : Cost of cutting and fixing in existing false ceiling deemed to be included in quoted rate.The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied.
S&F 12W Recessed mounted round shape LED downlight with minimum efficiency 100 lumen/W, THD<10%, HET diffuser, high quality Die cast aluminium housing, input voltage 220-240V,CCT 5700K, input frequency 50Hz including electric connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to fixture complete all as specified and directed. Make :Wipro (CRDL11R017HP57) /Philips (DN 393B LED 12S-6500-PSU-WH)/ ORIENT (LDRND-12-C) Note : Cost of cutting and fixing in existing false ceiling deemed to be included in quoted rate.The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied.
S&F 6W Recessed mounted round shape LED downlight with minimum efficiency 100 lumen/W, THD<10%, HET diffuser, high quality Die cast aluminium housing, input voltage 220-240V,CCT 5700K, input frequency 50Hz including electric connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to fixture complete all as specified and directed. Make :Wipro (CRDL11R008HP57) /Philips (DN391B LED 6S-6500-PSU-WH) / OSRAM (LDRND-06-C) Note : Cost of cutting and fixing in existing false ceiling deemed to be included in quoted rate.The contractor should submit LM79 and LM80 test certificates of the manufacturers for the batch of light fittings supplied. Note for all LED light fittings:- Incase of discrepancy between the description of items and the model number given, the model number shall prevail.
S&F Sheet metal enclosure for single pole and neutral DB 4 way 240V double door type with standard rated bus bar complete all as specified and as directed by Engineer-in-Charge. Make: L&T / Hager / Schneider / Siemens
S&F Sheet metal enclosure for single pole and neutral DB 8 Way 240V double door type with standard bus bar complete all as specified and as directed by Engineer-in-Charge. Make: L&T / Hager / Schneider / Siemens
S&F MCB SPN 32Amps 10 KA rupturing capacity 'C' curve complete all as specified and as directed by Engineer-in-Charge. Make: L&T/ C&S/ Legrand/ Schneider
S&F MCB SP 5/32 Amps 10 KA rupturing capacity 'C' curve complete all as specified and as directed by Engineer-in-Charge. Make: L&T/ C&S/ Legrand/ Schneider
Cutting chases, pinning in. making good to Stone concrete block or slab facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed by Engineer-in-Charge.
M&L Bore of 300mm Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres long, connected with earthing lead of size 25mm x 4mm dia galvanisedstrip to the earth test point 9upto 7.5m length) including earth work, returning, filling, fill compound to reduce soil sensitivity and high quality earth pit cover made of polymer all as specified and directed by Engr-in-Charge. Note:- The compound (earth enhance gel) to reduce soil resistivity should be suitable for the prevailing soil, IR value should be less than 5.0 Ohm. Excavation, earthwork returning and filling to be included in the quoted rate
M&L 20mm dia PVC conduit, heavy duty,including accessories like bends,junction boxes etc concealed on wall / on surface of roof ceiling all as specified and directed.
M&L 25mm dia PVC conduit, heavy duty,including accessories like bends,junction boxes etc concealed on wall / on surface of roof ceiling all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants,regulators, sockets,light fitting etc., removing materials to store for keeping in safe custody for taking credit (credit for above items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc point wiring all as specified and directed.
OM ENGINEERING
ambika electric co
roxy enterprise
S S Infrazone
Sukhi Electricals
jagdish machinery stores
Nitesh Enterprise
SURESH ELECTRICALS
JAYESH TRADING CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .