| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-01₹48.3 LAccepted-AOC | L-01 | Accepted-AOC Being lowest | |
| 2 | L-02₹53.1 L+₹3.1 L (6.18%)Rejected-Finance | L-02 | Rejected-Finance Not being lowest | |
| 3 | L-03₹54.0 L+₹4.0 L (7.96%)Rejected-Finance C O MALAY DUTTA MADHYAPARA OPP DARRANG COLLEGE GIRLS HOSTEL P O TEZPUR DISTT SONITPUR ASSAM 784 001 | SONITPUR | ASSAM | 784001 | L-03 | Rejected-Finance Not being lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
12 Oct 2024, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali
REPAIR TO FOOTPATH HARD STANDING, STORM WATER DRAIN, CULVERT, BOUNDARY WALL, FENCING, CONCERTINA COIL ETC AND REPAIRS TO DG SET AND ITS CONNECTED ITEMS AT CERTAIN LOCATION AT MISA CAMP UNDER GE (S) TEZPUR
2024_MES_674702_1
8925
Open Tender
Civil Works
Works
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
GE South Tezpur
₹96,000
Yes
24 Dec 2024
14 Sept 2024
14 Oct 2024
14 Sept 2024
12 Oct 2024
28 Sept 2024
14 Sept 2024 - 27 Sept 2024
Amount
Dismantling Reinforced Cement Concrete of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed.
Dismantling Wrought Iron or Mild Steel Work, viz. MS Flat Iron (Wind Tie) and Similar Work including MS Bolts, Nuts, etc., complete all as specified and as directed.
Demolition of Cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided. complete all as specified and as directed.
Dismantling AC Corrugated Sheets as in Roofing including Ridge or Similar Pattern Roof Coverings, complete all as specified and as directed.
M & L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with L type J type or cranked hook bolts complete all as specified and as directed.
S&F Steel work in tubular trusses/posts including special shaped washer etc complete using ERW or induction but welded tubes conforming to IS- 1161-1979 grade St-240 complete all as specified and directed.
M&L Hardcore of gauge not exc. 63 mm, broken stone aggregate deposited, spread andlevelled in layers n exc. 15 Cm thick, watered and rammed to a True Surface, complete all as specified and as directed.
M&L PCC 1:3:6 (nominal mix) Type C-2 using 40mm size stone aggregate as in sub base,flooring or in Fdn Work complete all as specified and directed.
M/L 75mm thick P.C.C 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection/sub base/base/path etc complete all as specified and directed.
M/L 100mm thick P.C.C 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base/path etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for 20mm thick Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L Prepolished Coloured Cement Concrete designers Chequered Tiles 300 x 300x 25 mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles complete including 15 mm screed bed in CM (1:6) of thickness complete all as directed.
M&L for for sand cushioning layer 40mm thick over sub base for fixing of interlocking tiles spread levelled to reqd level complete all as specified and directed.
S & F in repair Machine pressed precast concrete interlocking paver block gloosy finished of any shape and design and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade. complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
M&L Cement concrete (1:2:4) type-B-2(Using 40 mm graded stone agg) as in surface channel complete all as specified and directed.
M&L Cement Concrete 1:3:6 (40 mm graded crushed stone aggregate) as in Coping including necessary form-work, etc., complete all as specified and as directed.
M&L Pre-cast Reinforced Cement Concrete type B1(1:2:4) using 20 mm graded crushed stone aggregate) as in Cover Slab of Man Holes, Septic Tanks, etc., set in Cement Mortar 1:4 including necessary forms, moulds, etc., complete all as specified and as directed. NOTE : Reinforcement shall be measured and paid separately under relevant Item.
M & L TMT bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clip to Fe-410 incl fabrication complete all as specified and directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed.
M&L Rendering 15mm thick in Cement Mortar 1:4 on fair faces of Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth using WPC complete all as specified and directed. NOTE:-WPC shall be measured and paid separately under relevent item
M&L Rendering 15mm thick in Cement Mortar 1:4 on other than fair faces of Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and Smooth using WPC complete all as specified and directed. NOTE:-WPC shall be measured and paid separately under relevent item
Supply only Integral Water Proofing compound, conforming to IS 2645 and as approved, complete all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc. but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and as directed.
M&L Brick work with sub class' B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L Brick work with sub class' B' bricks of old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L Brick work with sub class'B' bricks,straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and as directed.
M&L RCC (Nominal Mix) 1:1.5:3 type A-1 (Using 20mm graded stone aggreagate) Beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and as directed. NOTE : Formwork and Reinforcement shall be Measured and Paid for separately under relevant Items.
M&L Formwork to Soffits of suspend slab such as Roof slab, Floor slab, landings and similar works horizontal or sloping etc., not exceding 200mm thick ,flat rough finished surfaces of concrete, complete all as specified and as directed.
M&L Preparing new Surfaces of Walls and applying Two Coats of Cement Base Paint over a coat of primer complete all as specified and as directed.
M&L Preparing old decorated plastered surfaces of Walls and applying Two Coat of Cement Base Paint complete all as specified and as directed.
M&L Preparing new Surfaces of Walls and applying Two coats of exterior emulsion antifungus paint by smart painting method over a coat of primer and applied over 1mm thick wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
M&L Complete removal of existing Treatment of old decorated Surfaces of Walls and applying Two coats of exterior emulsion antifungus paint by smart painting method over a coat of primer and applied over 1mm thick wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as specified and directed.
Dismantling fencing wire mesh,any type complete all as specified and as directed.
Dismantling posts and struts (wood, steel or RCC) any sectionebedded in concrete, including taking out embedded portion in concrete and making good disturbed ground complete all as specified and directed.
S&F Posts and Struts in fencing including cutting tops to shape as directed , drilling holes , notching for wire , etc , flat iron fillets ( for securing wire mesh etc ) including all necessary drilling , bolting riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L 25 x6mm thick flat iron fillets fixed to the fencing posts incl all necessary drilling bolting or riveting etc and similar work conforming ot Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F 10mm dia MS round bar fixed to chain link fening Top and bottom including fixing clips complete all as specified and directed.
S&F 10 mm dia Mild screw bolts machine made) with hexagonal or square heads at one end and screwed the other, or screwed on both ends each screwed end to be fitted with washers and one hexagonal or square nut but length of bolt n exc 5cm long complete all as specified and directed.
Excavating soft/loose soil in post holes (or similar holes) each n.exc 0.5 Cu.m getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance in exc 50m and making good surface complete all as specified and directed.
M&L for cement concrete type D2 1:3:6 (40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
S&F in repair galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing in repairs to any type of standared rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc. as directed (each line wire to be measured) complete all as specified and directed.
S&F Concertina Coil Helix fence comprising of strands on both "V" arm of angle alongwith one no of helix concertina of 750 mm diameter before stretch composed of 50 nos of spirals with additional half turns at the beginning and end to be stretched to 7 meters per coil & composed of wire designed as per Ministry of Defense requirement having continuous punched blade edged barbs on both sides of cold rolled low carbon steel tape as IS-513-DD Grade having barbe centre to centre pitch of 36mm along with barbe to barbe flattened strip width of 18.60 mm and centre width of 7.40mm. The barbs length should be 23.50mm & should have 180 deg. Straightness. The Razor Tape should have average galvanizing coating thickness of 12 microns (both sides inclusive). The core wire should be hot dip galvanised and conform to IS-4454-Part-I/1981-Grade-II with minimum wire diameter of 2.59mm and tensile strength of 1620/sq.mm including provision of additional coat of Anti corrosive Mint Green Paint by dipping process as in repair.complete all as specified and as directed.
S&F Chain link MS galvanised fencing pvc coated, 4mm dia wire and size of mesh 100x100mm x 3mm(minimum) including line wires to any type of standered rails, straining bolts, nut & bolt for angle iron post MS tie bars incl provisioning of binding wire etc complete.any size or type complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, n exe 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide, Zinc Chrome Primer, complete all as specified and as directed.
M&L Preparing new Steel or Iron Surfaces of any description, exe 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a coat of Red Oxide, Zinc Chrome Primer, complete all as specified and as directed.
S&F Framed work such as door or gates of angle or other section, grills, gratings, etc, with ends of bars shouldered and/or riveted ,or forged into spikes, framed guard bars; barred iron doors, ladders;framed balusters; walk ways,railings, frameworks of water tanks and similar work including pintle hinges stops hand made sliding door bolts etc complete all as specified and as directed.
S&F in repairs 15mm bore fancy type chromium plated bib cock long body with crutch or butterfly handle screwed down for iron pipes complete all as specified and as directed.
S&F in repair tank cover for PVC tank(500/750/1000Ltrs) cover with 6 mm dia MS bar hinging device and 6mm dia MS bar locking arrangement of 'S; type for monkey protection etc complete all as specified and directed.
Disconnecting existing tanks exc 500 L upto and incl n.exc 1000 L, setting aside (or lowering if required) for water tanks, dewatering,cleaning and sterilisation with wire /brush/fine steel wire brush, clothes, removing all dirt and scale and algae formation inside the tank by using bleaching powder including writing with yellow paint over of the tank wall as "TANK CLEANED ON' with date, month and year with a minimum of 10 cm height capital letters/numbers. The cleaning process would follow fwg stages as under: (a) To drain out the water by using exit valve or high capacity dewatering system (b) Cleaning all the algae formation inside the tank by using chemical as approved by GE. (c) Scrubbing the walls with mechanised scrubber & fresh water cleaning by high speed jet pump. (d) 1st stage of bacteria screening by degermification by using chemical Halogen compound as approved by GE (e) Cleaning the floor of the water tank by industrial vacuum cleaner. (f) 2nd stage of bacteria screening & sterilizing method by using UV ray within the tank & killing all suspended bacteria. (g) 3rd stage of bacteria screening by sterilizing the floor of water tank by using strong oxidizing agent chemical as approved by GE
Material and Labour for overhauling/servicing of DG set of capacity 125 KVA all as per manufacturer instructions, carrying out the changing of oil filter, air filter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distiled water and other required item will be paid under relevant item as supply only
Material and Labour for servicing of DG set of capacity 100 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distiled water, will be paid under relevant item as supply only as per OEM
Material and Labour for servicing of DG set of capacity 62.5 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distilled water will be paid under relevant item as supply only as per OEM
Material and Labour for servicing of DG set of capacity 40 KVA all as per manufacturer instructions, carrying out the changing of oil filter, airf ilter, checking of nut, bolts, washers, gaskets, screws, hose clamps, including draining out old engine oil and filling in new engine oil, filling in/top up coolent in radiators of water cooled engine, taking out air filter element cleaning the same with compressed air for the removing the dust or replace unserviceable element with new element, cleaning of waste oil or coolent from engine complete testing after repair for its smooth functioning all as specifed and directed. Note : (i) Replacement of minor spare parts like nut, bolt, gasket, 'o' ring shall be deemed in the quaoted rated. (ii) Oil filter, Air Filter, engine oil, coolent, distilled water will be paid under relevant item as supply only as per OEM
Material and Labour in replacement of automatic voltage regulator suitable for 40 KVA to 125 KVA DG set complete all as specified and directed.
Material and Labour for over hauling out Fuel injector pump from DG set carefully, transportation of the same to civil work-shop for repair & complete service of FIP pump and calibration on automatic setting machine, shifting of FIP pump from civil work-shop to worksite and re-fixing the same to DG set and testing complete of range 40 KVA, 62.5 KVA,125 KVA complete all as specified and directed.
Supply only engine oil suitable for diesel genrator 40 KVA to 125 KVA complete all as specified and as directed.
Supply only coolent "K' Care geniune for radiator of water cooled engines complete all as specified and as directed.
Supply only Oil filter element as per existing complete all as specified and directed.
Supply only Air filter element as per existing complete all as specified and directed.
Supply only distilled water for battery or radiator of engine used with coolent complete all as specified and as directed.
Supply and fixing in repair 'V' belt ribbed of (a) radiator fan belt, (b) battery charging dynomo belt, and (c) water pump belt all suitable for DG set complete all as specified and directed.
Material and Labour for Painting of DG set of capacity 62.5 KVA and 125 KVA at different location inside Misa camp through spray painting with two coats of approved fire proof metal paint complete all as specified and directed by Engr-in-Charge.
S&F in repair relay siutable for 125 KVA DG AMF Panel complete all as specified and directed.
Material and Labour for finding out defects of DG set Control panel and Taking out burnt wiring including u/s and serviceable components for reuse including Rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut bolt washer of various sizes including testing complete all as specified and directed.
Supply & fixing in repair of 150 AH,12Volts Battery complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair of 120 AH,12 Volts Battery complete all as specified and directed by Engr-in-Charge.
Dismantling self starter of DG set for repairing the starter by replacing carbon brushes, brush holder, bearings, solenoid coil, replacement of burnt aremeture, rewinding of Fd coils, replace of pinion gears etc, completer servicing and refixing after repair, testing/commissioning complete for DG Set any capacity complete all as directed Note : Replacement of solenoid coil, armeture coil, and pinion gear shall be deemed to be included in the quoated rate
Supply and fix in repair battery leads set appx 1.0 Mtr long, PVC insulated multistranded copper conductor 16 sqmm single core, duly fixed brass clamps, copper lugs for connections from DG battery to self starter on various DG Sets of any capacity installed complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement on load change over switch with advance Neutral switch in steel sheet metal enclosure 4 pole By pass Switch and 415 volts conforming to IS compact design of capacity 200 Amps complete all as specified and directed.
Supply, install, testing and commissioning of floor mounted LT outdoor panel board AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessories totally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for indoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick with CPRI Approved CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete including taking down old unserviceable LT panel all as specified and directed. BUSBAR :- Copper bus bar 500 Amps ,supported on non hygroscopic fibres and brass screws for mounting -04 Nos INCOMER:- S&F MCCB 4 pole 415 Volts of breaking capacity of 35 KA of 250 Amps with Fixed thermal and Fixed magnetic setting - 01 No INDICATING DEVICES:- S&F LED Indicating lamps for Main Supply indicating R, Y, B - 03 Nos S&F Digital Ampere Meter 31/2 digit display , incl CT having CTR 250/5 - 01 Nos & Digital Voltmeter 0-500 Volts , SIF 96 - 01 Nos OUTGOING FEEDERS:- S&F MCCB of 4 pole , 415volts of capacity 100 amps with breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 02 Nos S&F MCCB of 4 pole , 415volts of capacity 63 amps with breaking capacity of 16 KA Fixed thermal and fixed magnetic setting - 06 Nos
Excavation in trenches not exc. 1.5 Metre wide and exc. 1.50 Metre but not exc. 3.0 Metre or part there of in depth for foundation etc. orfo for cable trenches or for shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 25 Cm as in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Material (Soil) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15 cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured).
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete including dismantaling of old unservieacble bricks complete.
M&L 100 mm bore GI tubing light grade for protection of cable including necessary joint including taking down old u/s one complete all as specified and as directed.
All as per Item No 81 above but but 40 mm dia.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 300 sq. mm 3½ Core including Brass Glands complete all as directed by Engr-in-Charge.
All as per Item No 83 above but 185 Sqmm 3½ Core
All as per Item No 83 above but 120 Sqmm 3½ Core
All as per Item No 83 above but 95 Sqmm 3½ Core
All as per Item No 83 above but 50 Sqmm 3½ Core
All as per Item No 83 above but 25 Sqmm 4 Core
All as per Item No 83 above but 16 Sqmm 4 Core
All as per Item No 83 above but 16 Sqmm 2 Core
All as per Item No 83 above but 10 Sqmm 4 Core
All as per Item No 83 above but 10 Sqmm 2 Core
M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 400 Amp, with breaking capacity 35 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as directed.
Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 250 Amp, with breaking capacity 35 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as directed.
Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 200 Amp, with breaking capacity 25 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as directed.
Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 160 Amp, with breaking capacity 25 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as directed.
Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 100 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as directed.
Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 63 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as directed.
Supply and fixing in repair of MCB TPN 415 Volts, 63 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing one complete. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor's firm name while carrying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
BCL (BID ID -3129511)
M/S Jiban Krishan Das and Co (BID ID -3127653)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .