| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | ₹12.1 L Quoted ₹10.2 L | L1 | Accepted-AOC As per TCR. |
| 2 | L2₹10.4 L+₹18,514 (1.81%)Rejected-AOC | ₹10.4 L+₹18,514 (1.81%) | L2 | Rejected-AOC As per TCR. |
| 3 | Rejected-Technical NAI SARAI RAMGARH CANTT DISTT RAMGARH PIN 829122 | RAMGARH | JHARKHAND | 829122 | - | - | Rejected-Technical As per NIT. |
| Sl No | Description | Qty | Unit | M/S NEW ENTERPRISES L2 | M/S S.P. ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | A. Rear door interlocking VCB-OCB and Painting Providing and fixing of Limit Switch | 39 | Nos. | 4,255 ₹1,65,945 | 4,179 ₹1,62,981 Lowest |
| 2.00 | Providing and fixing of support Base plate for limit switch and accessories. | 39 | Mtrs. | 4,639 ₹1,80,921 | 4,557 ₹1,77,723 Lowest |
| 3.00 | Providing and fixing of Nut & Bolt | 18 | KG | 296 ₹5,328 | 291 ₹5,238 Lowest |
| 4.00 | Providing and fixing of material for wiring with ferrul lug and tie belt | 16 | Nos. | 3,929 ₹62,864 | 3,859 ₹61,744 Lowest |
| 5.00 | Material for painting of VCB and OCB | 16 | Nos. | 5,153 ₹82,448 | 5,061 ₹80,976 Lowest |
| 6.00 | B. Maintenance free chemical earth pit for transformer neutral earth and body earth and OCB VCB earth Providing and fixing of support insulator | 115 | Nos. | 1,465 ₹1,68,475 | 1,439 ₹1,65,485 Lowest |
| 7.00 | With 3 mtrs GI pipes having outer pipe dia of 50mm having 80-200 micron galvanising inner pipe dia of 25mm having 200-259 micron galvanizing, connection terminal dia of 12mm in nominal soil with 50 KG ( two bag) back filling bentonite compound UL listed and confirm to relevant international / indian standard around electrode upto ground level. | 10 | Nos. | 14,651 ₹1,46,510 | 14,388 ₹1,43,880 Lowest |
| 8.00 | Providing and fixing GI. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) | 390 | Mtrs. | 175 ₹68,250 | 172 ₹67,080 Lowest |
| 9.00 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. | 40 | Cum | 1,010 ₹40,400 | 992 ₹39,680 Lowest |
| 10.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 20 | Cum | 1,603 ₹32,060 | 1,574 ₹31,480 Lowest |
Tender Value
₹11.0 L
EMD Value
₹13,800
Closing Date
25 May 2026, 9:00 amClosed
Project Engineer EnM Bhurkunda Colliery
Office Of Project Engineer EnM Bhurkunda Colliery
Installation and commissioning of rear door interlocking of 3.3KV or 11KV VCB-OCB and maintenance free chemical earth pit for transformer neutral earth and body earth and OCB VCB earth of main 11KV/3.3KV substation under Bhurkunda Colliery.
2026_CCL_359573_1
PE(EnM)/BHK/e Tender/26-27/05
Open Tender
Electrical and Maintenance Works
Item Rate
25 days
Office Of Project Engineer EnM Bhurkunda Colliery
Please refer tender documents.
2 documents required · 2 mandatory
₹13,800
11 Sept 2026
14 May 2026
26 May 2026
15 May 2026
25 May 2026
15 May 2026
15 May 2026 - 20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | A. Rear door interlocking VCB-OCB and Painting Providing and fixing of Limit Switch | 39 | Nos. | 3,816.54 | ₹1,48,845.06 |
| 2 | Providing and fixing of support Base plate for limit switch and accessories. | 39 | Mtrs. | 4,161.51 | ₹1,62,298.89 |
| 3 | Providing and fixing of Nut & Bolt | 18 | KG | 266.32 | ₹4,793.76 |
| 4 | Providing and fixing of material for wiring with ferrul lug and tie belt | 16 | Nos. | 3,524.2 | ₹56,387.2 |
| 5 | Material for painting of VCB and OCB | 16 | Nos. | 4,622.02 | ₹73,952.32 |
| 6 | B. Maintenance free chemical earth pit for transformer neutral earth and body earth and OCB VCB earth Providing and fixing of support insulator | 115 | Nos. | 1,314.58 | ₹1,51,176.7 |
| 7 | With 3 mtrs GI pipes having outer pipe dia of 50mm having 80-200 micron galvanising inner pipe dia of 25mm having 200-259 micron galvanizing, connection terminal dia of 12mm in nominal soil with 50 KG ( two bag) back filling bentonite compound UL listed and confirm to relevant international / indian standard around electrode upto ground level. | 10 | Nos. | 13,140 | ₹1,31,400 |
| 8 | Providing and fixing GI. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) | 390 | Mtrs. | 157 | ₹61,230 |
| 9 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres. | 40 | Cum | 906 | ₹36,240 |
| 10 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 20 | Cum | 1,438.1 | ₹28,762 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.35 MB
BOQ_372435.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .