| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 CrAccepted-AOC | ₹5.8 Cr | L1 | Accepted-AOC Being L1 and found in order |
| 2 | L2₹6.0 Cr+₹20.0 L (3.42%)Rejected-Finance 193 1 CIVIL LINES BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | ₹6.0 Cr+₹20.0 L (3.42%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹6.1 Cr+₹23.6 L (4.04%)Rejected-Finance | ₹6.1 Cr+₹23.6 L (4.04%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹6.4 Cr+₹51.9 L (8.88%)Rejected-Finance | ₹6.4 Cr+₹51.9 L (8.88%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹6.5 Cr+₹64.2 L (11.0%)Rejected-Finance | ₹6.5 Cr+₹64.2 L (11.0%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹6.8 Cr
EMD Value
₹6.7 L
Closing Date
3 Apr 2024, 6:00 pmClosed
S C Negi Chief Engineer Bareilly Zone
HQ Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan Station Road Bareilly
UPGRADATION OF OTM OF LT REGT TO MED REGT AT RAIWALA
2024_MES_635726_2
CEBZ/DDN(H)/T-15 of 2023-24
Open Tender
Civil Works
Lump-sum
546 days
Raiwala
As per NIT
8 documents required · 8 mandatory
₹3,000
Yes
AGE I Raiwala
₹6.7 L
Yes
3 May 2024
11 Mar 2024
10 Apr 2024
11 Mar 2024
3 Apr 2024
26 Mar 2024
11 Mar 2024 - 18 Mar 2024
Amount
SCHEDULE A PART-I (BUILDING WORK)
Construction of Single Living Accn for 88 (08 Hav + 80 Ors) (G+1) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
Construction of Cook House including Dinning Hall (S/S) (RCC Framed Structure) with permanent specification all as shown on drawings and as specified.
SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder
SCHEDULE A PART II-B (Internal Water Supply)
S&F Brass Chromium Plated Wall Mixer for mixing hot and cold water with 'L' bend including shower of size 125 mm and shower arm , screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Brass Chromium Plated Angle Valve, fancy type screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed.
S&F Health faucet with hose & hook ( complete set) fixed to angle / stop cock 15 mm dia complete all specified and directed.
SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder
SCHEDULE A PART III-B (Internal Electrification)
M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in and including medium duty concealed PVC conduit 20 mm dia ISI marked or higher and conduit fittings and all accessories with suitable size of sunk stainless steel box 1.22 mm with & including decorative polycarbonate frame for housing modular switches, sockets, fan regulators etc including frame & white cover plate complete , including continuous earth wire PVC insulated, unsheathed, multi stranded copper conductor cable 1.5 sqmm (nominal area) FRLS-H grade, green colour, up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of the following. (Note: Colour code shall be maintained as per IE rule)
(a) One light point point /bell buzze/ ceiling fan/Exhaust fan point controlled by one-one way switch.
(b) One three pin 5 Amp socket on same board with other switches.
(c) One three pin 5 Amp socket on independent board
(d) All as per item No 6 here in before but for two way wiring
All as per item No-6 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity conductor of size 2.5 Sq mm.
All as per item No-6 above but one 3 pin socket outlet 15 Amp independent, with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm.
S&F DB VTPN, 415 volt with 250 amps rated copper bus bar for double door 8 way IP-54, IK-09 suitable for one MCCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB TPN, 415 volt with 250 amps rated copper bus bar for double door 4 way IP-54, IK-09 suitable for one MCB as incoming and MCB TPN as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 8 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
S&F DB SPN, 240 volt with 200 amps rated copper bus bar for double door 4 way IP-43, IK-09 suitable for one MCB SPN as incoming and MCB SP as out going, mounting flush on wall and making good disturbed surfaces complete all as specified and directed by Engr-in-charge . (MCBs shall be measured and paid separately).
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 1.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 1.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 2.5 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 2.5 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L sub main wiring in replacement with 2 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 4.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L sub main wiring in replacement with 4 Single core PVC insulated unsheathed FRLS-H cable 1100 Volts grade heavy duty copper conductor multistranded of size 16 Sq.mm. (nominal area) drawing in and including 25 mm. dia or higher PVC conduit medium duty concealed/ surface, conduit heavy duty accessories and fittings wit chasing/ cutting and Insulated unsheathed FRLS-H cable copper conductor multistranded of size 16.0 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
Supply & fix LED lamp 12 watt, 220 volt AC complete all as specified and directed.
Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep, min air delivery 245 CFM five star rated with brushless direct current induction motor complete all as specified and directed.
Supply, installation, testing and commissioning of Water Heater Storage Type five star rating, electric suitable for single phase ,50HZ, AC supply, stainless steel inner assembly, 2 KW heating element, Twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1M of three core 2.5 sq mm twisted copper conductor cable PVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6Kg/sq,CM with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopter at ends, at hot water outlet, with safety fusible plug confirming to relevant IS of 50 ltrs capacity.
Supply, fix, connecting and testing building LED security light fitting 20 W with pressure die cast aluminium housing, heat resistant toughened glass, IP 66 protection and impact resistance of IK 07 with 10KV Built-in Surge Protection Device, better optics for uniform distribution compete with electronic driver, including connecting up with three core copper conductor cable with 1.5 sqmm size copper wire from ceiling rose to connector of light fitting complete all as specified and directed.
Supply and fixing 63 Amp, 415 Volts four pole MCCB adjustable type with breaking capacity 16 KA and incl connections, testing and commissioning complete all as specified and directed.
Supply and fixing 40 Amp, 415 Volts four pole MCCB adjustable type with breaking capacity 16 KA and incl connections, testing and commissioning complete all as specified and directed.
M&L for point wiring with 1.5 Sqmm (nominal area) two single core PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade, FRLS-H grade in stove enameled steel conduit 20 mm dua including contineous earth wire pvc insulated unsheathed, multistranded copper conductor cable 1.5 mm (nominal area) FRLS-H grade green colour up to common earth and connected to earth dolly complete all as specified and directed by Eng.-in-charge. Note : - Rates for required Nos of FLP- WP multiple entry junction box in LM6 or cast iron suitable to provide FLP metallic house conduit, flame proof reducer, flame proof double compression cable glands is included in the quoted rate.
SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder
SCHEDULE A PART VA (Road, Path and Culvert) for details refer pdf folder
SCHEDULE A PART VB (Road, Path and Culvert)
M&L for applying thermoplastic reflective paint as in road marking of minimum 2.5mm thick single coat of 100/150 mm wide using HOT MARK thermoplastic paint (Hot application) white or golden yellow by indigenous modern properly road marking machine as directed incl all ingredients such as binder glass beads shall titanium dioxide calcium carbonate inter filler thermoplastic complete all as specified and as directed.
S&F cat eye solar reflective type of metal body alloy os size 100 mm x 100mmx 20 mm with PAMA striplens reflector of model No DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions complete all as specified and directed.
SCHEDULE A PART VI (Sewage Disposal) for details refer pdf folder
SCHEDULE A PART VII (Area Drainage) for details refer pdf folder
SCHEDULE A PART VIII (Fencing, Gate, Compound wall & Security wall) for details refer pdf folder
SCHEDULE A PART IX A (External Water Supply) for details refer pdf folder
SCHEDULE A PART X B (External Water Supply)
Supply, laying, connecting and testing pipe ductile Iron , including rubber gasket Class “K-7” of bore 80 mm dia all as specified and directed by Engineer-in-Charge.
Material and labour for construction of valve chamber of size 900x900x900 mm (internal dimensions) built in brick masonary 230 mm thick on 150 mm thick PCC foundation (1 : 4 : 8) type D-2 using 40 mm graded stone aggregate over 100 mm thick hard cor with brick work masonary in cement mortar 1:4 using 'B' class bricks and rendering in cement mortar 1: 4, 10 mm thick internally including exposed surfaces of external surfaces, MS cover made out of 3 mm thick MS sheet on angle iron framework made out of 40 x 40 x 3 mm duly embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with hold fast made out of MS flat iron 25 x 6 mm x 300 mm long and 40 mm thick PCC coping 40 mm thick 1:2:4 type B-0 using 12.5 mm graded stone aggregate with handle hinges with locking arrangement & applying two coats of synthetic enamel paint over a coat of red oxide primer to all exposed steel surfaces complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 14.02 above but of size 600x600x600 mm complete all as specified and directed.
M & L for DI fittings Tee,Bend, Tail piece etc all as specified and directed by Engineer-in-Charge.
SCHEDULE A PART X A (EXTERNAL ELECTRIC SUPPLY) for details refer pdf folder
SCHEDULE A PART X B (EXTERNAL ELECTRIC SUPPLY)
Supply, install, testing and commissioning transformer step down 11/0.433 KV outdoor type plinth mounted, copper wound AC 3 Phase, 50 Hz oil immersed naturally cooled delta connected on primary side (11 KV HV side) & star connected on secondary side (433 V LV side) in accordance with vector group Dyn-11 with neutral brought out on secondary side with tapping at ± 2.5% ±5% ±7.5% off load tap changer gear in steps of 2.5% continous rating of capacity 63 KVA including initial oil fill to appropriate level & all standard fitting all as per IS 1180 Pt 1989 and IS-2023 mounted on and incl platform of size 2.5 Mx2.5Mx1.5M high (outer dimension) built with 150 mm thick PCC 1:5:10 type E2 foundation extending 150 mm on both sides of wall, 350 mm thick of brick masonary built in CM 1:6, 450 mm below GL & 950 mm above GL duly plastered in CM 1:4 on exposed faces & flushing in same mortar as the work proceeds in faces in contact with soil /floor of 50 mm PCC 1:2:4 type B-1 laid in bays over 100 mm thick hardcore over approved earth filling complete all as specified and directed. The unit rate for each transformer includes the cost of following accessories/fittings :-
(a) Rating and terminal marking plates, non detachable (b) Earthing terminals with lugs-02 Nos (c) Lifting lugs for main tank and top cover (d) Thermometer pocket with cap along with dial type thermometer-01 No (e) Externally hand operated OFF circuit tap, changing device with locking arrangement. (f) Oil conservator tank with fitting hole, drain plug, prismatic oil level gauge. (g) Silica gel dehydrating breather charged with silica gel. (h) Top filter valve with plug (j) Drain valve with plug (k) Air Vent. (l) Explosion vent. (m) Earthing terminals with lugs-02 Nos (n) Lifting hooks. (o) Unidirectional reversible roller-04 Nos. (p) HV copper bushing-03 Nos. (q) LV copper bushing-04 Nos. (r) Radiators. (s) Arcing horn on HT side-03 Nos. (t) Terminal connection on the HV bushing. (u) Additional neutral separately brought out side, LV cable end box with bush insulator for neutral earthing. (v) First fill of Transformer oil upto appropriate level. (w) Base channel 100x50 mm, 460 mm long with holes to make them suitable for fixing on a platform or plinth.
Note : 1. The Trasformer shall be ISI marked with min energy efficiency level 3 as per IS 1180 (Pt-I) : 2014. 2. Any other accessories/work which is required to be provided as per relivent IS but not specified above will be provided by the firm without any extra cost to the Department the rate including Plinth for as per IS specification and manufacturer recommendation .
Supply, installation, testing and commissioning of 11 KV/12 KV , 630 Amps Non extensible, outdoor type, 2 Way RMU panel with isolators & 1 VCB, SF6 gas insulated, 11 KV Ring Main Unit contained with stainless steel tank suitable for out door use free standing and comprising of the folowing:-
(i) 2 Nos - 630 Amp triple pole, manually operated vaccum circuit breaker encapsulated in SF6 stainless steel tank with independent spring mechanism and fully rated earth switch with provision for earth of the cable.
(ii) 2 Nos - Air insulated cable boxes with split gland plate suitable for front side bottom entry 3 core cable upto 300 sqmm.
(iii) 1 Nos - 630 Amp triple pole, single break, 3-position ('ON', 'OFF' and 'EARTH') main switches, each with independent manual charged spring mechanism and fully rated earth switch with provision for earth and test of the cable.
(iv) 1 Nos - Air insulated cable boxes and glands suitable for front and bottom cable entry 3 core cable upto 300 sqmm.
(v) The Ring Main Unit should comprise of the following accessories : (a) 1 Mimic diagram on front panel complete with status indicators. (b) 1 Set of positive standard mechanical interlocks. (c) 2 Set of current transformers for metering and protective relays 100/50/1A, 2.5 VA, 5 P 10 class. (d) 2 Nos. self powered Numerical relay with 3 o/c and E/F. (e) 2 Nos. Master trip relay with auxilary relays for transformer fault indication. (f) 2 Nos. Trip circuit supervision relay with auxiliary relays for transformer fault indication. (g) 1 Nos. Power pack equipment with backup of 15 minutes for operation of relays. (h) 3 Set of LED indicator lamps for cable live indicator.
(j) Potential transformer 11KV/R3//110/R3//110/R3 - accuracy class 0.5/3P Burden with HT fuse and auxiliary PT 11 KV/230 V AC 500 VA. (k) 1 No. digital mutifunction meter, 3 line display. (l) 1 No. External stud for earthing connections. (m) 2 Nos. SF6 gas pressure indicator. (n) 2 Nos. local 'PULL TO TRIP' mechanism. (o) 1 No. operating handles. (p) 1 Set copper bus bars common for outgoing feeders. (q) Manual charging for operation arrangement. (r) Fuses for metering and protection system. (s) Front bottom entry of HT cables.
(t) Paint finish - All steel work will be finish painted in Dark grey shaded 632 as per IS. RMU Panel should have following general characteristics: RMU Panel should have following general characteristics: (i) Enclosure degree of protection - IP54 (ii) Type of Ventilation - Natural (iii) Rated Enclosure - IK 10 (iv) Rated power frequency withstand voltage KV RMS/min - 28/38 kv (v) Rated lighting impulse withstand Voltage kv, 1.2/50 micro sec - 75/95 kv (vi) Short time current rating ka, for sec - 21 kA/3 sec (vii) Rated short circuit making current - 50 kA (viii) Reference standard - As given in PS.
NOTE - Necessary drawing shall be got approved before placing order and PDI including testing shall be carried out by the rep of accepting officer. The cost of PCC platform for mounting RMU panel as per manufacturers instruction is deemed to be included in the quoted rates. The quoted rates must include the cost of cable termination kit cold shrikable type, cable glands, outside panel, cable lugs, cable trenches etc., cable between RMU & metering cubicals, lugs & glands & arrangements for 1 run / phase
Supply, installation, testing and commissioning of automatic power factor improvement capacitor bank having aggregate capacity 35 KVAR in 12 stage, microprocessor based along with factory made type panel weather proof, vermin proof, fully ventilated both side opening and fabricated out of CRCA sheet 3.00 mm thick & frame angle of size 50mm x 50mm x 6mm having bus bar of Aluminium 200 Amps capacity, three phase and one neutral fixed on insulator and bus bar insulated by colored heat shrinkable sleeve & housed in specified compartment. Including powder coating internally externally the entire steel surfaces. All the cover shall have suitable locking arrangements, fully internally wired with suitable size of thimbles. Incoming/outgoing internal connection with PVC insulated PVC sheathed multi stranded copper wire of suitable size all as directed and comprising the following :-
(2) The panel manufacturer should have following certification : (i) CPRI certification Degree of protection IP-54 (should have IEC:61439-1 & 2 IEC:60529 tests). (ii) CPRI certification short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A. (3) MCCB (Microprocessor based) provided should be capable for on line setting of the current. (4) All the eletrical switch gear like MCCBs, MCBs and ACBs should be of same make. (5) Drawing of panel board should be got approved from AGE(I) Raiwala before fabrication. (6) Panel board should be fully compartemtnalized in accordance to form 4 b of IEC 61439-1-2.
(7) Any item technically required for proper functioning of APFC panel but not mentioned in the item is deemed to be included in item rate quoted by the firm. (8)The Location of APFC Panel is newly constructed Light to Medium Regt Site inside Raiwala Military camp .
(5) Drawing of panel board should be got approved from AGE(I) Raiwala before fabrication. (6) Panel board should be fully compartemtnalized in accordance to form 4 b of IEC 61439-1-2. (7) Any item technically required for proper functioning of APFC panel but not mentioned in the item is deemed to be included in item rate quoted by the firm. (8)The Location of APFC Panel is newly constructed Light to Medium Regt Site inside Raiwala Military camp .
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 32x6 mm GI strip as earth lead by means of brass nuts and bolt,thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size (1:2:4) Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified
including and provision of GI strip upto 7.5 mtrs long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing strip to panel, including testing on completion complete all as specified and directed by Engr-in-charge. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick rainforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI strip more than 7.5 mtrs will be measured and paid seperately under relevant items. (Transformer -04 Nos + LT Panel Two Nos - 04 Nos+ APFC Panel -02 Nos + Load break switch-02 Nos = 12 Nos)
S&F thermoplastic cable junction box/enclosure (distribution box) for outdoor installation with knockouts for cable entry suitable for cable size 10-16 Sqm of dimension 300x200x105 mm with cable terminals and 01 no MCB (0-5 Amp) 10 KA , B curve , 230 volts complete fitted on pole with synthetic enamelled paintover one coat of red oxide Zink crome primer on clamps complete all as specified and directed.
Supplying and erecting in true vertical position steel tubular swaged pole, 09 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, final taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:4:8 type D2, using 40 mm graded stone aggregate and PCC 1:3:6 type C2, using 40 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with colour (200mm wide each) synthetic enamelled paint at a distance 200 mm from plinth, block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete and provided anti climbing device and danger notice plates etc) complete all as specified and directed.(Note:Excavation and PCC work measured and paid separtely)
M&L for fixing light grade GI bracket made out of 50 mm dia light grade pipe 1.2 mtr long bend to shape as directed fixed to steel tubular pole with two number MS clamp made out of 40x5 mm flat iron duly painted with two coats of synthetic enamelled paint over one coat of red oxide Zink crome primer with and including nuts, bolts , necessary welding and bending for insert new LED fitting 60 watt etc complete all as specified and directed.
Supply and Fix cable route indicator of minimum 120mm dia and thikness of the plates not less than 6mm, embeded 11KV HT of bold letters, welded on 2 feet MS angle of size 40/40 mm on plates including grounding 1.5 feet under ground and PCC complete all as specified and directed
Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Out door type, totally enclosed, dust and vermin proofm suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm 4 core), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -
(a) Busbarchamber : Electrically grade copper shrouded bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, fixed on DMC insulators and provision of extension.(Main Panel from Transormer LT side) INCOMER : (i) MCCB 125 Amps, 415Volts, 4 pole 50 Hz, 35 KA with adjustable ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Multifunction meter = 01 set. (iii) Phase Indication lamps (RYB), LED type - 01 No (set of three).
Outgoing : (a) (i) MCCB 63 Amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%=Icu(1 sec) complete all as specified and directed. 02 Nos (ii) MCB SPN 32 amps- 04 Nos
Notes : - (a) Panel manufacturers should have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes : degreasing / water rinsing / de-rusting / water rinsing / activation / phosphating / water rinsing / passlvation. (b) Thickness of powder coating shall not be less than 80 mocrons and test certificate for power coating shall be furnished along with LT panel. (c) The panel manufacturer should have following certification :-
(i) CPRI Certification Degree of protection IP-54 (should have IEC:61439-1-2 & IEC:60529 tests). (ii) CPRI certificates short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A. (iv) All the electrical switch gear like MCCBs, MCBs should be of same make, (v) Drawing of panel board should be got approved from GE before fabrication. (vi) Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
Material and Labor for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, Out door type, totally enclosed, dust and vermin proofm suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side open able, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm 4 core), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -
(a) Busbarchamber : Electrically grade copper shrouded bus bar of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears, fixed on DMC insulators and provision of extension INCOMER : (i) MCCB 63 Amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable ,microproseccsor release in built instantaneous protection, Ics = 100%=Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Multifunction meter = 01 set. (ii) Phase Indication lamps (RYB), LED type - 01 No (set of three).
Outgoing : (a) (i) MCCB 40 Amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%=Icu(1 sec) complete all as specified and directed. 02 Nos (ii) MCB SPN 32 amps- 04 Nos
Notes : - (a) Panel manufacturers should have in house powder coating plant with minimum 8 tanks pretreatment of MS sheet facilities, dust free spray paint booth. (8 tanks pretreatment process includes : degreasing / water rinsing / de-rusting / water rinsing / activation / phosphating / water rinsing / passlvation. (b) Thickness of powder coating shall not be less than 80 mocrons and test certificate for power coating shall be furnished along with LT panel. (c) The panel manufacturer should have following certification :-
(i) CPRI Certification Degree of protection IP-54 (should have IEC:61439-1-2 & IEC:60529 tests). (ii) CPRI certificates short circuit with stand strength should be 50 KA RMS for 1 sec with initial peak of 105 KA. (iii) CPRI certification rated current for short circuit not less than 5000A. (iv) All the electrical switch gear like MCCBs, MCBs should be of same make, (v) Drawing of panel board should be got approved from GE before fabrication. (vi) Panel board should be fully compartmentalized in accordance to form 4 b of IEC 61439-1-2.
M & L for cutting of road /hard standing as required at site, not exceeding 20 cm width and not exceeding 90 cm in depth for laying of cable protection pipe including insert the cable inside pipe making good the disturbed road/hard standing by providing PCC (1:2:4) Type B-1 up to the existing surface level and make good complete all as directed.
Sudhir Sharma Associates
VEE SONS BUILDERS PVT LTD
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED
M/S SHANTI SARUP DINESH CHAND
M/S Mukesh Kumar Gupta
CHITTER MAL & CO
JASPAL SINGH & CONST
SANJEEV CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .