Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.4 L+₹4.4 L (34.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical PLOT NO 2 INDUSTRY AREA NEAR LAL WARE HOUSE OPP OLD HOUSING BOARD COLONY SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | - | Rejected-Technical Not appropriate category | |
| 4 | Rejected-Technical | - | Rejected-Technical Not appropriate category |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
28 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(KH)YOL
GE(KH)YOL
REPAIR AND MAINTENANCE OF VCBs AND MISC WORKS AT VARIOUS LOCATION AT YOL CANTT UNDER GE YOL CANTT
2020_MES_407532_1
GEY-62/2020-21
Open Tender
Civil Works
Item Rate
183 days
YOL CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE(KH)YOL
₹40,000
Yes
1 Mar 2021
28 Dec 2020
30 Jan 2021
28 Dec 2020
28 Jan 2021
15 Jan 2021
60 days
Amount
Dismantling/ taking out old unserviceable cable of any size and removing from site, complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts (Earthed), grade cross sectional area 95 sqmm 3 core, laid in trenches or passing through pipes/ ducts or fixed to walls/ poles complete including testing complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm 4core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 Sqmm 4core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing after laying complete all as specified. Note for Srl item Nos. 02 to 05:- Excavation and earth work, sand cushioning & cable cover shall be measured and paid separately.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to and including galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete M-15 reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 metres long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron strip 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of reinforced cement concrete M-15, reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. NOTE :- Item of earthing includes the cost of 7.5 metre long galvanised iron earth wire 4mm size and protection pipe of 15mm bore galvanised iron light grade and earth work.
Renewal lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amps for 11000 volts complete all as specified and directed.
Renewal of aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, all as specified.
Renewal of aluminium strip 25x4mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, all as specified.
Renewal of Air termination, single pointed, Aluminium rod 12mm dia and 300mm long , all as specified.
loose filling with broken/ crushed stone aggregate of size 20 mm complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified.
Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-55 (11m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC including dismantling of old type PCC poles any length , complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately.
Plain cement concrete M-7.5 nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundation of poles, stays etc. as mass concrete, complete all as specified.
Plain cement concrete M-10 nominal mix, type C-1 using 20mm graded crushed stone aggregate as in coping of pole including necessary form work , complete all as specified.
Cleaning of installation area from inside and outside by removing bushes , shurbs , grass and other vegetation materials by screaching out earth surface , cleaning the fungus formation and nearby growth of wild vegetation, bushes to a distance of 50 metres away all as specified and directed.
Triming of tree branches after taking shut down from power house, 1.0 metre apart from HT/LT line carefully and considering the span from pole to pole, complete with cleaing the whole area grabbed by the the trimed branches of tree, complete all as specified.
Painting to existing steel tubular HT poles, 11 metres long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers of 2 inches bold letters with black paint after painting, complete all as specified & directed
Painting to four pole structure made out of steel tubular HT poles, 11metres long including cross arms, channels, angle iron support, bracings, clamps etc. with one coat of aluminum paint superior quality of approved make on surfaces exposed to view above PCC benching including preparation of old painted surfaces by scraping etc complete including making 30 cms wide strips (total 05 Nos) with white and black paint alternatively and writing pole numbers of 2 inches bold letters with black paint after painting, complete all as specified & directed.
Painting to two/ three pole structure made out of steel tubular HT poles, 11 metres long including cross arms, channels, angle iron support, bracings, clamps etc. with one coat of aluminum paint superior quality of approved make on surfaces exposed to view above PCC benching including preparation of old painted surfaces by scraping etc complete including making 30 cms wide strips (total 05 Nos) with white and black paint alternatively and writing pole numbers of 2 inches bold letters with black paint after painting, complete all as specified & directed.
Mild steel galvanised light grade 100mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Mild steel galvanised light grade 80mm dia tubing with all fitting; laid in trenches, across road or on pole complete all as specified.
Excavation in trenches for cable and poles in any type of soil n.exc 1.5m wide and not exc 1.5m deep and getting out complete all as specified and directed.
Excavation in trenches for cable and poles in any type of soil n.exc 1.5m wide and but exc 1.5 metre deep and not exc 3.00 metre deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cms thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5metres above the starting point complete all as specified and directed.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Supply, installation, testing and commissioning gang operated air break off load connecting switch HT, 11KV, tripple pole, each plate consisting galvanised steel base, verticle type mounted on 15 No's post insulators and steel frame, non ferrous knife and spring loaded contacts, arcing horns complete with dropout fuse element assembly, operating rod of GI pipe, medium grade, 20 mm dia (without joint) of suitable size and locking arrangement, connections, mild steel frame with PG clamps and sleeves etc required for current rating 400 amps capacity including taking down unservicable steel frame all as specified and directed.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm, complete all as specified.
Renewal of cable jointing kit for 11 KV (Earthed) grade cable for straight through, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm, complete all as specified.
Repair to HT VCB 11 KV 3 phase 630 Amp 250MVA of installed at main power house/ sub stations after disconnecting the main supply incoming panel for repairs and replacement of U/S parts and refixing the same after repair and testing on full load (cost of spare parts and other job works will be paid under respcetive items) complete all as specified and directed. Note:- (a) Service will be carried out through service engineer of manufacuturer employee of authorised dealer shall be hired for servicing of VCB. (b) Rates are deemed to include the cost of all tools, materials and labour required for dismantling taking out and assembling of VCB with replacement of worn out nuts and blots gaskets A grade greasing and oiling of moving parts and refixing the same. (c) Rates are deemed to include the cost of material and labour required to make alternative arrangement to bypass the electric supply through the HT panel or other HT line to avoid longer period of shut down of electric supply.
Calibration of over current relay (IDMTL) in 5 amp time 0.5 sec, calibration of earth fault relay (IDMTL) in 5 amp time 0.01 sec (VCB ) adjusting the setting of over current and earth fault with HPSEB complete all as directed.
Supply, installation, commissioning and testing bus chamber factory made Outdoor type, CPRI approved, size 0.45mx0.75mx0.4m deep, fabricated out of 3.15 mm thick mild steel sheet and vermin proof with neoprene gasket having front opening and locking arrangement with IP-54 protection as per IS-8623, duly powder coated (Internally and externally) for 415 volts, 3 phase, 4 wire having TPN aluminium bus bars of 200 Amps rating duly drilled holes for connections, RYB insulated with different color code and sleeved insulators complete prewired and copper cable connection with all incoming and outgoing cable connection with suitable size of lugs and glands including one No MCCB with adjustable thermal and fixed magnetic release of capcity of 100 amps, 415 volt, 25 KA, 3 pole (Cat Part No. IHCASTO100 of 'Havells' or equivalent in makes mentioned in Appendix 'C') fixed in PCC M-15, type B-0, using 12.5 mm graded crushed stone aggregate including taking down old unservicable chamber all as specified.
Cable route indicator made out of 2mm thick mild steel of size 20cmx15cm duly coated with two coats of black paint over a coat of red oxide primer duly written the size of HT/LT cable in white paint and welded to equal angle of size 30mmX30mmX3mm , 45cm long and errected in ground in such a way that it is 15cm above ground level and 30Cm below ground level . The portion below ground level should be embedded in plain cement concrete M-15, type B-1 using 20mm graded crushed stone aggregate of size 15cmx20cmx45xcm including earth work complete all as specified. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
PVC seperator suitable for four ACSR Conductor feeder, complete all as specified.
Supply and fixing hand charging rod with with suitable size of VCB complete all as specified.
Repair/ replacement of lifting lock in and out VCB complete all as directed.
Markig plate for Earthing location (Body earthing / Neutral earthing ) made out of 2 mm thick mild steel sheet of size 20 cms X 15 cms duly coated with two coats of black paint over a coat of red oxide primer duly written the angle of size 30X30X3mm, 45 cms long and errected in ground in such a way that it is 15 cms above ground level and 30 cms below ground level. The portion below ground level should be embedded in plain cement concrete M-15, type B-I, using 20 mm graded crushed stone aggregate of size 15 cms X 20 cms X 45 cms all as specified & directed. Note:- Cost of PCC and earth work & excavation shall be deemed to be included in unit rate quoted by contractor.
Supply & fix three pole power contactor, 415 Volts ML-4, Conforms to IS/IEC60947-4-1 & IEC 60947-4-1, Rating 70A for AC-3 & 100A for AC-1, I Robust and suitable for hostile applications for street light control including electric connection complete all as specified & directed including taking down old one.
Supply & fix street light timer FM1/Quartz Daily 240V AC Base/DIN Mounting analogue type suitable for street light control complete all as specified & directed including taking down old one.
Repair for Earthing including connection complete all as specified & directed
Disconnecting of HT connections and DC connections from existing bus bar and disconnecting trolley including servicing of complete parts of RMU 3 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc and checking complete parts, repairs to control wiring with single core copper conductors of existing size as required at site of RMU 3 way of any type, any make for satisfactory running and replacement of defective spare parts, applying one coat of 11 KV insulation paint on busbar, spouts and other connected parts and reassembling the same re-connecting all HT & AC / DC connections complete in functional order including testing on existing load complete all as specified and directed. Note: 1. Spare parts shall be measured and paid for separately under respective items of this schedule as supply only (in replacement). These shall be identical to those specified by original manufacturer. Small parts such as nuts, bolts, screws & washers required at site are deemed to be included in the cost quoted by the contractor .
Supply only self powered protection relay of RMU complete all as specified and directed : Make : SEG, type WIC 1 or equivalent as approved
Supply only Resin cast ring core protection Current Transformer of Ratio 14.4 / 0.075A, Class 10P80, VA 0.1 (OR suitable for relay type W1C1), 50 C/S of RMU complete all as specified and directed Make : ERICON transformers or equivalent as approved
Supply only Resin cast ring core metering Current Transformer of Ratio 80/1A, Class 1.0, VA-2.5, 50 C/S of RMU complete all as specified and directed Make : ERICON transformers or equivalent as approved
Supply only Digital Multifunction meter for 11 KV RMU as per existing sample complete all as specified and directed. Make : Rishab Model Rish master 3430 or equivalent as approved
Supply only Shunt Tripping coil as per existing sample of RMU as per existing sample complete all as specified and directed
Supply only Trip Coil for 11 KV VCB complete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only Closing Coil for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only Spring charging motor for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only gear set for charging system for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only spot insulator for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only indicator lamp for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only Unnumerical Relay for 11 KV VCB complete all as specified . Make:- CG & alstom or equivalent as approved make
Supply only HRC fuse for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only Limit switch for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only Insulated operating Rod for 11 KV complete in all respect all as specified and directed. Make:-VCB CG & alstom or equivalent as approved make
Supply only Amp meter for 11 KV VCB complete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only Volt meter for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only Mechanism for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & alstom or equivalent as approved make
Supply only CT for ratio 100-50/5/Amp 11 KV VCB complete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only CT for ratio 200-100/5/Amp 11 KVcomplete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only CT for ratio 600-300 11 KV VCB complete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only PT for ratio 110/5A 11 KV dry type VCB complete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only CRC Spray for 11 KV VCB complete in all respect all as specified and directed. Make:-CG & alstom or equivalent as approved make
Supply only Panel Heater for 11 KV VCB complete in all respect all as specified and directed. Make:- CG & astom or equivalent as approved make
M/S MALHI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .