| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.1 LAccepted-Finance 8 K P BANERJEE SARANI KONNAGAR HOOGHLY 712235 | KONNAGAR | HOOGHLY | WEST BENGAL | 712235 | L1 | Accepted-Finance LOWEST BIDDER | |
| 2 | L2₹1.0 Cr+₹5.0 L (5.07%)Rejected-Finance 2ND FLOOR 8 A J C BOSE ROAD CIRCULAR COURT KOLKATA WEST BENGAL 700017 | KOLKATA | WEST BENGAL | 700017 | L2 | Rejected-Finance SECOND LOWEST BIDDER | |
| 3 | L3₹1.1 Cr+₹6.9 L (6.93%)Rejected-Finance 8J CHANDRA MONDAL LANE KOL 700 026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | L3 | Rejected-Finance THIRD LOWEST BIDDER | |
| 4 | Rejected-Technical 37 JANAK ROAD 2ND FLOOR EASTERN WING KOLKATA 700029 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | - | Rejected-Technical Technical specification as per BoQ is not fully complied and all requisite MAF not given | |
| 5 | Rejected-Technical 612 MARSHALL HOUSE 612 MARSHALL HOUSE 33 1 NETAJI SUBHAS ROAD KOLKATA 700 001 DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical Technical specification as per BoQ is not fully complied and all requisite MAF not given |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
13 Jun 2025, 5:00 pmClosed
SE,IT CIRCLE
KIT Annex Building 5th Floor, India Exchange Place Extension, Kolkata 700 073
Additional Recommendation of Data, Wifi and P.A System Plan for new G Plus 4 Court Building, Purulia
2025_WBPWD_847652_1
WBPWD/SEITC/NIT-05 OF 2025-2026
Open Tender
IT WORKS ORG
Item Wise
60 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹2.0 L
SE,IT CIRCLE OFFICE
10 Jul 2025
16 May 2025
16 Jun 2025
16 May 2025
13 Jun 2025
23 May 2025
21 May 2025
Amount
PART A: FOR LAN NETWORKING
SITC of Dual Band Wireless Access Point with POE Injector 802.3ax GIGABIT with perpetual license of OEM, having minimum technical specification: AP type: Indoor, dual radio, 5GHz 802.11ax 2x2 MIMO and 2.4GHz 802.11ax 2x2 MIMO, Dual-band radios; 20, 40, and 80 MHz Channels; 5GHz radio: 1.2 Gbps data rates and 2.4GHz radio: 575Mbps on dual concurrent radio operations; Packet Aggregation (AMSDU, AMPDU); Reduced Interface Spacing; Layer 2 and Layer 3 Layer 3 routing, 802.1q, DynDNS, DHCP server/client, BOOTP client, PPPoE and LLDP; Security: Stateful Firewall, IP filtering, NAT, 802.1ax, 802.11i, WPA2, WPA Triple Methodology Rogue Detection: 24x7 dual-band WIPS sensing, on-board; IDS, and secure guest access (hotspot); Quality of Service (QoS) WMM, WMM-UAPSD, 802.1p, Diffserv, and TOS; Operating Channels: 2.4 GHz band: channel 1 through channel 13, 5.2 GHz band: channel 36 through channel 165. Ref. Make: Cisco, Allied Telesis,zyxel,Netgear Licence: 03(Three) Years subscription with 24x7 Comprehensive on-site support and 03(Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of stackable, Layer 3, fully managed, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM, having minimum technical specification: a) 16 x dual-purpose 10GBase-F SFP+ host ports (Minimum); b) 8 x 10GBase-F SFP+ including modular and field replaceable SFP module of same rating; c) Switch should have atleast 480 Gbps, non blocking of switching capacity d) 350 mpps Forwarding Performance; support atleast 12K IPv4 and 1K IPv6 Static Routing Entries, support atleast 256 IP Interface and 8K IP Address Table 4K static/dynamic VLANs, 4K static/dynamic VLANsSwitch should support Protocol Based VLANs should support MAC-based VLAN, Double VLAN Tagging (QinQ), should support IEEE 802.3x (Full Duplex and flow control), IEEE 802.1D STP, IEEE 802.1w RSTP, IEEE 802.1s MSTP, : BPDU Control, Loop Guard, Intrusion Lock, BPDU Guard, Spanning Tree Root Guard, IGMPv2 Snooping, IGMPv3 Snooping, MLDv1 Snooping, Switch should support IPv4, IPv6 DHCP Client, Switch should support Ipv4, IPv6 DHCP Server, Switch should support DHCP Relay, Switch should support VRRP, should support RIP v1, v2, Switch should support OSPFv2, should support Multipath – ECMP, should support 802.1ab LLDP-MED, should support SNMP v1, v2c, v3, should support RMON 1,2,3, RADIUS, TACACS+,Multiple RADIUS server, Multiple TACACs+ server, HTTP, SSL/TLS, Telnet, SSH, FTP, TFTP, should support NTP/SNTP client, Switch should have CSA 60950-1, EN 60950-1, IEC 60950-1, EMC, FCC Part 15 (Class A). Make Cisco, Allied Telesis,zyxel,Netgear Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of 24Port, Layer 3, PoE enabled, with PD: minimum 370 Watt (should have minimum 15.4 Watt per Port), Full managed only, 1RU, GE Switch to be operated on 200-240VAC, 50 Hz Supply, with perpetual license of OEM, having minimum technical specification: a) 24 x 10/100/1000Base-T Mbps PoE+ enabled host ports (Minimum); b) 4 x 10GBase-F SFP with 2 x 10G Multi-Gigabit (1G/2.5G/5G/10G) RJ-45 PoE++ (60 W) uplink ports; c) Forwarding performance/stacking bandwidth/ backplane speed (Minimum) of 125 Mpps; d) Fanless operation with operating temperature up to 50°C; e) DRAM and Flash RAM as per OEM; f) Software support with IPv4 routing (542 routes), multicast routing (IGMP) including necessary software license; g) Minimum switching capacity of 168Gbps; h) Number of VLAN Supported: 64 (Minimum).; i) Total number of MAC Address: 32,000 (Minimum); j) Minimum Security: User privilege management and password protection, DoS attack defense, ARP attack defense, and ICMP attack defense, Binding of the IP address, MAC address, interface, and VLAN, Port isolation, port security, and sticky MAC, MFF, Blackhole MAC address entries, Limit on the number of learned MAC addresses, 802.1x authentication and limit on the number of users on an interface, AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC, SSH v2.0, Hypertext Transfer Protocol Secure (HTTPS), CPU defense, Blacklist and whitelist; Access Security: DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security; k) Others: Applicable standards: IEEE 802.1p: CoS prioritization , IEEE 802.1Q: VLAN tagging, IEEE 802.1X: Port Access Control, IEEE 802.3: 10BASE-T, IEEE 802.3u: 100BASE-T,IEEE 802.3ab: 1000BASE-T, IEEE 802.3z: 1000BASE-X,IEEE 802.3af: Power over Ethernet, IEEE 802.3at: Power over Ethernet Plus, IEEE 802.3x: Pause Frames/Flow Control, IEEE 802.1D: Spanning Tree Protocol, IEEE 802.1s: Multiple instances of Spanning Tree Protocol (MSTP), IEEE 802.1w: Rapid reconfiguration of Spanning Tree Protocol, IEEE 802.3ad: Link Aggregation Control Protocol; l) REGULATORY: RoHS, WEEE, IEC 61000-4-2:2008, CISPR Class, ICES-003 Class A,UL,CSA 22.2,FCC,EN 300 386, CCC, ICES -003, CB. The OEM should have 24x7 TAC support center with India toll free number reflected in official website. Ref. Make: Cisco, Allied Telesis,zyxel,Netgear Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of Next generation Network Security Firewall having minimum technical specification: Firewall throughput: 16 Gbps (min), IPS throughput: minimum 9 Gbps, Threat Prevention throughput: minimum 4 Gbps, NGFW throughput: 8 Gbps (min), concurrent connections: minimum 4.2 Million and 90,000 connection per second. Hardware Architecture: 16x 10/100/1000Base-T RJ-45 ports, 4 x 10bE SFP fiber WAN port and 2x 2.5GbE ports, 1x 1GbE copper/fiber DMZ port, 512 GB SSD storage and micro-sd slot, 16 GB RAM. Firewall should have security controls such as Firewall, VPN, Identity Awareness, QoS, Application Control, URL Filtering, IPS, Anti-Bot, Antivirus, DNS Security and Anti-Spam, support IPsec and SSL VPN functionality, support the dynamic routing protocols with readiness for OSPF, BGP and RIP, PIM (SM, DM, SSM), IGMP, Anti-virus, file filtering, content filtering, QoS, IPS must be able to detect and block network and application layer attacks, protecting at least the following services: email services, DNS, FTP, Windows services, must have an integrated Anti-Bot and Anti-Virus application, FCC, VCCI, IEC 62368, RoHS and UL cerified, The OEM must provide 24 x 7 technical support. Make :- Checkpoint / Paloalto / Shopos/Fortinet/Sonicwall Warranty: 03 (Three) years Onsite comprehensive OEM warranty with parts and service.
PART B: SOUND AND PA SYSTEM
SITC of 2-zone PA mixer amplifier with a built-in digital player, Power Output: Maximum Power: 300W + 300W, RMS Power: 200W + 200W at 10% THD,180W + 180W at 5% THD, Inputs: Microphone/Aux: 6 x Mic , 2 x Aux , Line Input (each zone): L/R 1V/50k ,Digital Player: Built-in MP3 player with USB, SD, and MMC card reader,Outputs: Preamp: 200mV/600Ω,,Line: 1V/1kΩ Speaker Output (for each zone): 4Ω, 8Ω, 70V, & 100VAudio Performance: Frequency Response: 50-15,000Hz ±3dB Signal to Noise Ratio: Output Regulation: ≤ 2 dB, no load to full load at 1kHz. Multiple Connectivity Options: Includes XLR, 1/4" TRS, and RCA inputs for versatile audio source connections. Make : YAMAHA/ Dynachord/ British Acoustics/Ahuja/Studiomaster. Warranty: 03 (Three) years Onsite comprehensive OEM warranty with parts and service.
SITC of 21" Gooseneck Microphone with Base: Polar Pattern: Cardioid , Gooseneck Length: 21 inches ,Frequency Response: 20Hz - 20kHz Sensitivity: -40dB ,Impedance: 280 Ω ,Max SPL (Sound Pressure Level): 140dB (at T.H.D.<1%) Signal to Noise Ratio (S/N): >92dB . must be Supplied with a base that features an On/Off Switch and an LED indicatorr. Make: Bosch/Sennheiser/Telvic/Studiomaster/AudioTechnica/AKG Warranty: 03 (Three) years Onsite comprehensive OEM warranty with parts and service.
PART C: UPS NETWORKING
SITC of 2 x 06 KVA Rack Mount Online UPS (1-ph input, 1-ph output) System with 2 x 6240 VAH (Min) Back-up Battery, Rack, Links, Cables and Other Accessories having minimum technical specification: Technology: Rack mount, Digital Signal Processing (DSP) controlled Microprocessor based technology true On-line, Parallel Load Sharing Mode (1+N) configuration enabled only; Input: 1-phase, 220/230/240V, 176 ~ 280 Vac (full load) ; 80 ~ 175 Vac (50% ~ 100% load), >0.99PF (full load), 50Hz ± 5Hz, Current Harmonic Distortion <3.0%; Output: 1-phase, 240V ± 1%, > 0.9PF (full load), 50 Hz ± 0.1Hz; Harmonic Distortion (input current): < 3% (linear load); Crest factor: 3:1; Efficiency (AC/DC) Overall is (Online Mode) >=95% at full load; Operating Temperature: 0 ~ 55°C; Relative Humidity: 5 ~ 95% (non-condensing); Battery: SMF, 12 V, Mono Block batteries. The UPS battery shall be of Advanced Glass Mat Valve Regulated Sealed Lead Acid Battery Construction type (AGM or VRSLAB) in ABS Flame Retardant (UL94V-O) grade (UL 2436) spill containment casing to meet UL 62368-1/IEC 62133 or equivalent standards type to obtain a full rated load battery backup, standard FR DC Cable; Battery set: Complete with self standing cubicle or cabinet; Certification: CE, BIS; Type Test Report: ISO 9001, ISO14001,OSHAS18001; Display: LCD display and LED indicators; Separate Battery bank and Single Battery Rack Enclosure (perforated enclosure and wheel based) with accessorised accessories. Including necessary Earthing arrangement. 2 x 06 KVA 1Ø/1Ø (Phase input/output) with 2 x 6240 VAH (Min) Battery Backup or equivalent VAH or Higher, DC BUSBAR VOLTAGE ±240/±288; 12V SMF Battery, with MS-Rack, Interlink Nyvin Cable, Connector, Special battery terminal insulation cover and other accessories. Ref. Make: Schneider, APC, Vertiv,Delta,Numeric. Ref. Make Battery: Amararaja-Quanta/Exide; Warranty: 03(Three) years on UPS & 03(Three) years on Battery onsite comprehensive OEM warranty with parts and service except force majeure.
PART D : Concealing and Cable Tray arrangement
SITC of PVC Conduit 25 MM Dia Complete as Required Laying Over Surface or Through Cable duct as Required.Make: Precision/Polycab/presto as approved by EIC Ref. Make: Precision, Prestoplast, Supreme, Oriplast Warranty: 03(Three) years OEM warranty with parts and service except force majeure.
SITC OF PVC Duct Casing. 75*75 MM (4 Inch) Ref. Make: Precision, Prestoplast, Supreme, Oriplast Warranty: 03(Three) years OEM warranty with parts and service except force majeure.
PART E : PASSIVE COMPONENTS FOR Data Networking (LAN)
SITC of Networking Horizontal Single Sheathed unrmoured Cable, 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 1-500 MHz (Minimum) Category 6, 4-Pair, SF/UTP, 23 AWG solid bare copper conductors with FEP insulation, polyester separator, individually shield, LSZH OUTER sheath COVER as to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 and TIA/EIA 568C. Ref. Make: Molex, 3C3, Legrand, Commscope,Derwiser Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of Indoor Information Outlet with RJ45 adapter, GI box and Single face cover plate etc having minimum technical specification Ref. Make: Molex, 3C3, Legrand, Commscope,Derwiser Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of CAT 6 U/UTP 24 Port Modular Fully Loaded Patch Panel ISO 11801 AMD 1 Class EA TIA-568-C.2 Cat 6 ANSI/EIA-1069-A IEC 60603-7 Ref. Make:Molex, 3C3, Legrand, Commscope,Derwiser Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of PATCH CHORD Category 6 4-Pair, U/UTP, Horizontal cable, 23 AWG solid bare copper conductors WITH RJ45 CONNECTOR AT BOTH END 1 MTR LENGTH 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 1-500 MHz (Minimum), Category 6, 4-Pair, U/UTP, 23 AWG solid bare copper conductors with FEP insulation, polyester separator, LSZH OUTER sheath COVER as to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 and TIA/EIA 568C. Ref. Make: Molex, 3C3, Legrand, Commscope,Derwiser Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of PATCH CHORD Category 6 4-Pair, U/UTP, Horizontal cable, 23 AWG solid bare copper conductors WITH RJ45 CONNECTOR AT BOTH END 2 MTR LENGTH 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 1-500 MHz (Minimum), Category 6, 4-Pair, U/UTP, 23 AWG solid bare copper conductors with FEP insulation, polyester separator, LSZH OUTER sheath COVER as to standard of ISO/IEC 11801Ed. 2.0, EN 50173-1 and TIA/EIA 568C. Ref. Make: Molex, 3C3, Legrand, Commscope,Derwiser Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
32U x 800 x 800/500 Rack - Front Glass Door with Cam Lock - Fan Unit of 360CFM(Min) / 230 Volt - 4no - 6; Way 5A PDU, along with input Cable - 2no - H/w Packet of 20 - 8no - 1U PVC Cable Manager - 6no. Ref. Make:Tata, Netrack, Valrack, Rittal, APW, MRS Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of floor mounted Cross Connect Equipments 9U AV Rack Front Glass Door with Cam Lock - Fan Unit of 90CFM / 230 Volt - 1no - 6 Way, SA POU, along with input Cable lno.Hardware packet of 20-3 Nos. Make: Tata, Netrack, Valrack, Rittal, APW, MRS Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of WALL Mounted Cross Connect Equipments 12U x 600 x 500 Rack - Front Glass Door with Cam Lock - Fan Unit of 90CFM / 230 Volt - 1no - 6 Way 5A PDU, along with input Cable - 1no . Hardware packet of 20-3 No., Ref. Make: Tata, Netrack, Valrack, Rittal, APW, MRS Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of 06 Core, 50/125 Micron, OM3 Multi Mode Uni Tube Double Sheathed Corrugated Steel Armoured Fiber Optic Cable having minimum technical specification. Ref. Make: Molex, 3C3, Legrand, Commscope,Derwiser Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of Multi Mode LIU, 24F, 1U Drawer shelf, Fully loaded with SC, OM3 Pigtails, Adapters, Splice Trays, Fiber Management Rings and Splice Slvees. Ref. Make:Molex, 3C3, Legrand, Commscope,Derwiser, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of Multi Mode LIU, 12F, 1U Drawer shelf, Fully loaded with SC, OM3 Pigtails, Adapters, Splice Trays, Fiber Management Rings and Splice Slvees. Ref. Make:Molex, 3C3, Legrand, Commscope,Derwiser, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of 10Gb Duplex Multi mode 50/125 OM3 LSZH Armoured Fiber Patch Cable, SC-SC/ SC-LC/ LC-LC as per sites requirements - 3 MTR Ref. Make:Molex, 3C3, Legrand, Commscope,Derwiser, Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of 10G Base SR Multi Mode modular and field replaceable SFP module of same rating of Ethernet Switch & OEM Ref. Make: Cisco, Allied Telesis,zyxel,Netgear Warranty: 03 (Three) Years onsite comprehensive OEM warranty with parts and service except force majeure.
PART F : PASSIVE COMPONENTS FOR SOUND & PA SYSTEM
SITC of all types of Audio Specialist Connectors etc, as per site requirement. Make :- Nutric, Byron, Electronicgrup; Warranty: 03 (Three) years Onsite comprehensive OEM warranty with parts and service.
SITC of shielded Audio Cables, with 2 core 1sqmm copper, FRLS PVC insulated ISI marked multi stranded microphone cable for XLR connectors as per site requirement. Make :- Finolex /BELDEN / EURO/Crystal for cables & Nutric for Connectors; Warranty: 03 (Three) years Onsite comprehensive OEM warranty with parts and service.
SITC of 1.1KV grade, 2 core 1.5 sqmm copper, FRLS PVC insulated & sheated ISI marked multi stranded black speaker cable as per site requirement. Make :- Finolex / Polycab/ RR Kable/ Haveles/ BELDEN Warranty: 03 (Three) years Onsite comprehensive OEM warranty with parts and service.
PART G: PASSIVE COMPONENTS FOR UPS NETWORKING
SITC of UPS sub DB 250V, 16 way SPN MCBDB with Sheet Steel Enclosure Double Door with IP-42/43 Protection with DP Isolator as Incomer and SPMCB (C-curve, 10Ka) as outgoing: 2+14way Enclosure (607711 or Latest), 43A/63A DP Isolator, 12 No.16A SPMCB. Make: Schneider, Legrand, Hager, SIEMENS, L&T, ABB, Havells Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of Surge protection devices of 275VAC, lP+lN, Type 2, 40KA, Make :-ABB, Schneider As approved by EIC
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil 3.5 CUM [Electrical Scedule :-G-1, Item no l(a)I
Earthing Installation -with Pipe Electrode:- Earthing with SO mm dia GI pipe 3.64 mm thick x 3.04 Mts. longand 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl.5 &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: a) ISI-Medium GI pipe as per electrical schedule PWD WB.
SITC of UPS to SPN DB Power at different location through suitable power networking with 2.5/4/6 Sq mm 3 core FRLS PVC insulated armoured ISI marked copper cable as per site requrment. Switch, Sockets & MCB Make: Legrand, Hager, SIEMENS, L&T, Wire Make: Polycab, Mescab, Finolex, Havells,RR Kabel Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
SITC of SPNDB to Network and AV Racks, etc at different location through suitable power networking with 2.5 Sq mm 3 core FRLS PVC insulated unarmoured ISI marked copper cable as per site requrment), 6A/16A Sockets with Separate 6A/16A Switch and 6A/16A MCB mounted in 16SWG GI box with Bakelite top cover complete. Number of power point as per site requirment and as per direction engineer-in-charge. Switch, Sockets & MCB Make: Legrand, Hager, SIEMENS, L&T, Wire Make: Polycab, Mescab, Havells, Finolex,RR Kabel Warranty: 03 (Three) years onsite comprehensive OEM warranty with parts and service except force majeure.
ADD GST @18%
Labour Welfare Cess @1%
Embee Software Private Limited (BID ID -6555211)
ACTIVE (BID ID -6560372)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .