| 1 | L1₹6.2 LAdmitted-Finance II 335 VIYYUR SHORANUR ROAD VIYYUR THRISSUR KERALA 680010 | THRISSUR | KERALA | 680010 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | HINDUSTAN FURNACES PVT. LTD L1 |
|---|---|---|---|---|
| 1.00 | Dismantling, shifting and re-assembly of existing Ghee Storage Tank of size 1500 × 1500 × 5000 mm (L), 10 Gauge thick, made of SS 304 Grade, including dismantling of the Ghee Heating Tank, pumping system, connected SS pipelines and fittings installed over the storage tank; cutting the storage tank into suitable sections using cutter/arc cutting, shifting the dismantled sections to the proposed new location, properly aligning, re-assembling and welding the sections to restore the tank to its original configuration, including all necessary labour, materials, tools and tackles. The reassembled tank shall be properly tested for leakage of all welded joints. The Ghee Heating Tank, pumping system and associated fittings shall thereafter be reinstalled over the Ghee Storage Tank, including extension and reconnection of the existing SS pipeline from the existing connection point to the new location, including all necessary labour, materials, fittings, accessories, tools and tackles, complete in all respects as per the directions of the departmental officials. MOC: SS 304 Grade Tank Size: 1500 × 1500 × 5000 mm (L) Thickness: 10 Gauge | 1 | job | 6,15,960 ₹6,15,960 Lowest |
Tender Value
Refer Docs
EMD Value
₹13,050
Closing Date
17 Sept 2026, 6:00 pmClosed
EXECUTIVE ENGINEER, ELECTRICAL DIVISION
EXECUTIVE ENGINEER OFFICE, ELECTRICAL DIVISION, TRAVANCORE DEVASWOM BOARD, CHENGANNUR
Shifting of existing Ghee tank to new location for new Aravana preparation area RETENDER
2026_TDB_867602_2
TDB/EEE/ET-37/2026-27
Open Tender
Miscellaneous Works
Item Rate
45 days
sabarimala
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,232
₹13,050
23 Sept 2026
14 Sept 2026
19 Sept 2026
14 Sept 2026
17 Sept 2026
14 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling, shifting and re-assembly of existing Ghee Storage Tank of size 1500 × 1500 × 5000 mm (L), 10 Gauge thick, made of SS 304 Grade, including dismantling of the Ghee Heating Tank, pumping system, connected SS pipelines and fittings installed over the storage tank; cutting the storage tank into suitable sections using cutter/arc cutting, shifting the dismantled sections to the proposed new location, properly aligning, re-assembling and welding the sections to restore the tank to its original configuration, including all necessary labour, materials, tools and tackles. The reassembled tank shall be properly tested for leakage of all welded joints. The Ghee Heating Tank, pumping system and associated fittings shall thereafter be reinstalled over the Ghee Storage Tank, including extension and reconnection of the existing SS pipeline from the existing connection point to the new location, including all necessary labour, materials, fittings, accessories, tools and tackles, complete in all respects as per the directions of the departmental officials. MOC: SS 304 Grade Tank Size: 1500 × 1500 × 5000 mm (L) Thickness: 10 Gauge | 1 | job | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
SBD377.pdf
Tender Documents • 1.43 MB
FORMATofDOCUMENTStoBEdulyFILLEDinSIGNEDandUPLOADEDbytheCONTRACTOR.pdf
Tender Documents • 0.87 MB
BOQ_1473426.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .